All MIBs › IEEE8021-CFM-MIB
Organization: IEEE 802.1 Working Group
Last Updated: 2018-06-28
Category: Standard: IEEE 802, Technology: OAM
Description:
IEEE 802.1 MIB for Connectivity Fault Management (CFM/802.1ag) providing OAM maintenance domain and MEP management.
Imported Objects
From IEEE8021-TC-MIB
| IEEE8021VlanIndex | |
| ieee802dot1mibs | OBJECT-IDENTITY |
From IF-MIB
| InterfaceIndex | |
| InterfaceIndexOrZero |
From LLDP-MIB
| LldpChassisId | |
| LldpChassisIdSubtype | |
| LldpPortId | |
| LldpPortIdSubtype |
From Q-BRIDGE-MIB
| VlanId | |
| VlanIdOrNone |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| MacAddress | |
| RowStatus | |
| TAddress | |
| TDomain | |
| TEXTUAL-CONVENTION | |
| TimeInterval | |
| TimeStamp | |
| TruthValue |
What Is IEEE8021-CFM-MIB?
IEEE8021-CFM-MIB is the vendor-neutral IEEE 802.1 standards MIB implementing Connectivity Fault Management (CFM, IEEE 802.1ag) for Carrier Ethernet OAM, used to detect, verify, and isolate connectivity faults across bridged/VLAN networks. It exposes configuration and status data for Maintenance Domains, Maintenance Associations, and Maintenance association End Points (MEPs), including how MEPs stack against interfaces and VLANs. It supports software/protocol status monitoring: via the CFM stack table an operator can see which MEP is active on a given interface/VLAN combination, and receive fault notifications when a MEP loses continuity with its peers, though it does not cover physical sensors like temperature or power. It depends on the base IEEE 802.1Q bridge/VLAN model and typically works alongside IF-MIB (via ifIndex references in the stack table) for interface correlation. It's deployed on Carrier Ethernet switches and bridges in provider and enterprise networks that use CFM for service-level OAM. Network engineers who search for an ieee8021-cfm-mib download usually want the module definition itself so they can compile CFM fault-management support into their NMS or SNMP agent tooling.
IPNetwork Monitor allows you to monitor SNMP objects defined in IEEE8021-CFM-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
What Can Be Monitored
- MEP stack per interface/VLAN
- MEP MAC address and ID
- maintenance domain level
- CFM connectivity fault notifications
- VLAN-to-maintenance-association mapping
Supported Devices
- vendor-neutral, standards-based MIB, not tied to a specific manufacturer
- Carrier Ethernet switches/bridges supporting IEEE 802.1ag CFM
Monitoring Examples
An operator can poll dot1agCfmStackTable/dot1agCfmStackEntry (indexed by dot1agCfmStackifIndex and dot1agCfmStackVlanIdOrNone) to see which MEPs (dot1agCfmStackMepId, dot1agCfmStackMacAddress) are stacked on which interface and maintenance domain level (dot1agCfmStackMdLevel), and watch for a MEP disappearing from the table or a dot1agNotifications trap firing, which signals a lost continuity check / connectivity fault between MEPs. The dot1agCfmVlanTable further confirms which VLANs have CFM instances associated with a maintenance association.
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| ieee8021CfmMib | 1.3.111.2.802.1.1.8 | Connectivity Fault Management module. Unless otherwise indicated, the references in this MIB module are to IEEE Std 802.1Q. Copyright (C) IEEE (2018). This version of this MIB module is part of IEEE Syd 802.1Q; see the draft itself for full legal notices. | ||
| dot1agNotifications | 1.3.111.2.802.1.1.8.0 | |||
| NTF dot1agCfmFaultAlarm | 1.3.111.2.802.1.1.8.0.1 | A MEP has a persistent defect condition. A notification (fault alarm) is sent to the management entity with the OID of the MEP that has detected the fault. Whenever a MEP has a persistent defect, it may or may not generate a Fault Alarm to warn the system administrator of the problem, as controlled by the MEP Fault Notification Generator State Machine and associated Managed Objects. Only the highest-priority defect, as shown in Table 20-1, is reported in the Fault Alarm. If a defect with a higher priority is raised after a Fault Alarm has been issued, another Fault Alarm is issued. The management entity receiving the notification can identify the system from the network source address of the notification, and can identify the MEP reporting the defect by the indices in the OID of the dot1agCfmMepHighestPrDefect variable in the notification: dot1agCfmMdIndex - Also the index of the MEP's Maintenance Domain table entry (dot1agCfmMdTable). dot1agCfmMaIndex - Also an index (with the MD table index) of the MEP's Maintenance Association network table entry (dot1agCfmMaNetTable), and (with the MD table index and component ID) of the MEP's MA component table entry (dot1agCfmMaCompTable). dot1agCfmMepIdentifier - MEP Identifier and final index into the MEP table (dot1agCfmMepTable). | ||
| dot1agMIBObjects | 1.3.111.2.802.1.1.8.1 | |||
| dot1agCfmStack | 1.3.111.2.802.1.1.8.1.1 | |||
| dot1agCfmStackTable | 1.3.111.2.802.1.1.8.1.1.1 | not-accessible | There is one CFM Stack table per Bridge. It permits the retrieval of information about the Maintenance Points configured on any given interface. **NOTE: this object is deprecated due to re-indexing of the table. | |
| dot1agCfmStackEntry | 1.3.111.2.802.1.1.8.1.1.1.1 | not-accessible | The Stack table entry **NOTE: this object is deprecated due to re-indexing of the table. | |
| NUM dot1agCfmStackifIndex | 1.3.111.2.802.1.1.8.1.1.1.1.1 | InterfaceIndex | not-accessible | This object represents the Bridge Port or aggregated port on which MEPs or MHFs might be configured. Upon a restart of the system, the system SHALL, if necessary, change the value of this variable, and rearrange the dot1agCfmStackTable, so that it indexes the entry in the interface table with the same value of ifAlias that it indexed before the system restart. If no such entry exists, then the system SHALL delete all entries in the dot1agCfmStackTable with the interface index. **NOTE: this object is deprecated due to re-indexing of the table. |
| VLA dot1agCfmStackVlanIdOrNone | 1.3.111.2.802.1.1.8.1.1.1.1.2 | VlanIdOrNone | not-accessible | VLAN ID to which the MP is attached, or 0, if none. **NOTE: this object is deprecated due to re-indexing of the table. |
| DOT dot1agCfmStackMdLevel | 1.3.111.2.802.1.1.8.1.1.1.1.3 | Dot1agCfmMDLevel | not-accessible | MD Level of the Maintenance Point. **NOTE: this object is deprecated due to re-indexing of the table. |
| DOT dot1agCfmStackDirection | 1.3.111.2.802.1.1.8.1.1.1.1.4 | Dot1agCfmMpDirection | not-accessible | Direction in which the MP faces on the Bridge Port **NOTE: this object is deprecated due to re-indexing of the table. |
| U32 dot1agCfmStackMdIndex | 1.3.111.2.802.1.1.8.1.1.1.1.5 | Unsigned32 | read-only | The index of the Maintenance Domain in the dot1agCfmMdTable to which the MP is associated, or 0, if none. |
| U32 dot1agCfmStackMaIndex | 1.3.111.2.802.1.1.8.1.1.1.1.6 | Unsigned32 | read-only | The index of the MA in the dot1agCfmMaNetTable and dot1agCfmMaCompTable to which the MP is associated, or 0, if none. **NOTE: this object is deprecated due to re-indexing of the table. |
| DOT dot1agCfmStackMepId | 1.3.111.2.802.1.1.8.1.1.1.1.7 | Dot1agCfmMepIdOrZero | read-only | If an MEP is configured, the MEPID, else 0 |
| MAC dot1agCfmStackMacAddress | 1.3.111.2.802.1.1.8.1.1.1.1.8 | MacAddress | read-only | MAC address of the MP. **NOTE: this object is deprecated due to re-indexing of the table. |
| dot1agCfmDefaultMd | 1.3.111.2.802.1.1.8.1.2 | |||
| DOT dot1agCfmDefaultMdDefLevel | 1.3.111.2.802.1.1.8.1.2.1 | Dot1agCfmMDLevel | read-write | A value indicating the MD Level at which MHFs are to be created, and Sender ID TLV transmission by those MHFs is to be controlled, for each dot1agCfmDefaultMdEntry whose dot1agCfmDefaultMdLevel object contains the value -1. After this initialization, this object needs to be persistent upon reboot or restart of a device. |
| DOT dot1agCfmDefaultMdDefMhfCreation | 1.3.111.2.802.1.1.8.1.2.2 | Dot1agCfmMhfCreation | read-write | A value indicating if the Management entity can create MHFs (MIP Half Function) for the VID, for each dot1agCfmDefaultMdEntry whose dot1agCfmDefaultMdMhfCreation object contains the value defMHFdefer. Since, in this variable, there is no encompassing Maintenance Domain, the value defMHFdefer is not allowed. After this initialization, this object needs to be persistent upon reboot or restart of a device. |
| DOT dot1agCfmDefaultMdDefIdPermission | 1.3.111.2.802.1.1.8.1.2.3 | Dot1agCfmIdPermission | read-write | Enumerated value indicating what, if anything, is to be included in the Sender ID TLV (21.5.3) transmitted by MHFs created by the Default Maintenance Domain, for each dot1agCfmDefaultMdEntry whose dot1agCfmDefaultMdIdPermission object contains the value sendIdDefer. Since, in this variable, there is no encompassing Maintenance Domain, the value sendIdDefer is not allowed. After this initialization, this object needs to be persistent upon reboot or restart of a device. |
| dot1agCfmDefaultMdTable | 1.3.111.2.802.1.1.8.1.2.4 | not-accessible | For each Bridge component, the Default MD Level Managed Object controls MHF creation for VIDs that are not attached to a specific Maintenance Association Managed Object, and Sender ID TLV transmission by those MHFs. For each Bridge Port, and for each VLAN ID whose data can pass through that Bridge Port, an entry in this table is used by the algorithm in 22.2.3 only if there is no entry in the Maintenance Association table defining an MA for the same VLAN ID and MD Level as this table's entry, and on which MA an Up MEP is defined. If there exists such an MA, that MA's objects are used by the algorithm in 22.2.3 in place of this table entry's objects. The agent maintains the value of dot1agCfmDefaultMdStatus to indicate whether this entry is overridden by an MA. When first initialized, the agent creates this table automatically with entries for all VLAN IDs, with the default values specified for each object. After this initialization, the writable objects in this table need to be persistent upon reboot or restart of a device. **NOTE: this object is deprecated due to re-indexing of the table. | |
| dot1agCfmDefaultMdEntry | 1.3.111.2.802.1.1.8.1.2.4.1 | not-accessible | The Default MD Level table entry. **NOTE: this object is deprecated due to re-indexing of the table. | |
| OID dot1agCfmDefaultMdComponentId | 1.3.111.2.802.1.1.8.1.2.4.1.1 | Dot1agCfmPbbComponentIdentifier | not-accessible | The Bridge component within the system to which the information in this dot1agCfmDefaultMdEntry applies. If the system is not a Bridge, or if only one component is present in the Bridge, then this variable (index) MUST be equal to 1. **NOTE: this object is deprecated due to re-indexing of the table. |
| VLA dot1agCfmDefaultMdPrimaryVid | 1.3.111.2.802.1.1.8.1.2.4.1.2 | VlanId | not-accessible | The Primary VID of the VLAN to which this entry's objects apply. **NOTE: this object is deprecated due to re-indexing of the table. |
| T/F dot1agCfmDefaultMdStatus | 1.3.111.2.802.1.1.8.1.2.4.1.3 | TruthValue | read-only | State of this Default MD Level table entry. True if there is no entry in the Maintenance Association table defining an MA for the same VLAN ID and MD Level as this table's entry, and on which MA an Up MEP is defined, else false. **NOTE: this object is deprecated due to re-indexing of the table. |
| DOT dot1agCfmDefaultMdLevel | 1.3.111.2.802.1.1.8.1.2.4.1.4 | Dot1agCfmMDLevelOrNone | read-write | A value indicating the MD Level at which MHFs are to be created, and Sender ID TLV transmission by those MHFs is to be controlled, for the VLAN to which this entry's objects apply. If this object has the value -1, the MD Level for MHF creation for this VLAN is controlled by dot1agCfmDefaultMdDefLevel. **NOTE: this object is deprecated due to re-indexing of the table. |
| DOT dot1agCfmDefaultMdMhfCreation | 1.3.111.2.802.1.1.8.1.2.4.1.5 | Dot1agCfmMhfCreation | read-write | A value indicating if the Management entity can create MHFs (MIP Half Function) for this VID at this MD Level. If this object has the value defMHFdefer, MHF creation for this VLAN is controlled by dot1agCfmDefaultMdDefMhfCreation. The value of this variable is meaningless if the values of dot1agCfmDefaultMdStatus is false. **NOTE: this object is deprecated due to re-indexing of the table. |
| DOT dot1agCfmDefaultMdIdPermission | 1.3.111.2.802.1.1.8.1.2.4.1.6 | Dot1agCfmIdPermission | read-write | Enumerated value indicating what, if anything, is to be included in the Sender ID TLV (21.5.3) transmitted by MHFs created by the Default Maintenance Domain. If this object has the value sendIdDefer, Sender ID TLV transmission for this VLAN is controlled by dot1agCfmDefaultMdDefIdPermission. The value of this variable is meaningless if the values of dot1agCfmDefaultMdStatus is false. **NOTE: this object is deprecated due to re-indexing of the table. |
| dot1agCfmVlan | 1.3.111.2.802.1.1.8.1.3 | |||
| dot1agCfmVlanTable | 1.3.111.2.802.1.1.8.1.3.1 | not-accessible | This table defines the association of VIDs into VLANs. There is an entry in this table, for each component of the Bridge, for each VID that is: a) a VID belonging to a VLAN associated with more than one VID; and b) not the Primary VLAN of that VID. The entry in this table contains the Primary VID of the VLAN. By default, this table is empty, meaning that every VID is the Primary VID of a single-VID VLAN. VLANs that are associated with only one VID SHOULD NOT have an entry in this table. The writable objects in this table need to be persistent upon reboot or restart of a device. **NOTE: this object is deprecated due to re-indexing of the table. | |
| dot1agCfmVlanEntry | 1.3.111.2.802.1.1.8.1.3.1.1 | not-accessible | The VLAN table entry. **NOTE: this object is deprecated due to re-indexing of the table. | |
| OID dot1agCfmVlanComponentId | 1.3.111.2.802.1.1.8.1.3.1.1.1 | Dot1agCfmPbbComponentIdentifier | not-accessible | The Bridge component within the system to which the information in this dot1agCfmVlanEntry applies. If the system is not a Bridge, or if only one component is present in the Bridge, then this variable (index) MUST be equal to 1. **NOTE: this object is deprecated due to re-indexing of the table. |
| VLA dot1agCfmVlanVid | 1.3.111.2.802.1.1.8.1.3.1.1.2 | VlanId | not-accessible | This is a VLAN ID belonging to a VLAN that is associated with more than one VLAN ID, and this is not the Primary VID of the VLAN. **NOTE: this object is deprecated due to re-indexing of the table. |
| VLA dot1agCfmVlanPrimaryVid | 1.3.111.2.802.1.1.8.1.3.1.1.3 | VlanId | read-create | This is the Primary VLAN ID of the VLAN with which this entry's dot1agCfmVlanVid is associated. This value MUST not equal the value of dot1agCfmVlanVid. **NOTE: this object is deprecated due to re-indexing of the table. |
| ROW dot1agCfmVlanRowStatus | 1.3.111.2.802.1.1.8.1.3.1.1.4 | RowStatus | read-create | The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. **NOTE: this object is deprecated due to re-indexing of the table. |
| dot1agCfmConfigErrorList | 1.3.111.2.802.1.1.8.1.4 | |||
| dot1agCfmConfigErrorListTable | 1.3.111.2.802.1.1.8.1.4.1 | not-accessible | The CFM Configuration Error List table provides a list of Interfaces and VIDs that are incorrectly configured. **NOTE: this object is deprecated due to re-indexing of the table. | |
| dot1agCfmConfigErrorListEntry | 1.3.111.2.802.1.1.8.1.4.1.1 | not-accessible | The Config Error List Table entry **NOTE: this object is deprecated due to re-indexing of the table. | |
| VLA dot1agCfmConfigErrorListVid | 1.3.111.2.802.1.1.8.1.4.1.1.1 | VlanId | not-accessible | The VLAN ID of the VLAN with interfaces in error. **NOTE: this object is deprecated due to re-indexing of the table. |
| NUM dot1agCfmConfigErrorListIfIndex | 1.3.111.2.802.1.1.8.1.4.1.1.2 | InterfaceIndex | not-accessible | This object is the IfIndex of the interface. Upon a restart of the system, the system SHALL, if necessary, change the value of this variable so that it indexes the entry in the interface table with the same value of ifAlias that it indexed before the system restart. If no such entry exists, then the system SHALL delete any entries in dot1agCfmConfigErrorListTable indexed by that InterfaceIndex value. **NOTE: this object is deprecated due to re-indexing of the table. |
| DOT dot1agCfmConfigErrorListErrorType | 1.3.111.2.802.1.1.8.1.4.1.1.3 | Dot1agCfmConfigErrors | read-only | A vector of Boolean error conditions from 22.2.4, any of which may be true: 0) CFMleak; 1) ConflictingVids; 2) ExcessiveLevels; 3) OverlappedLevels. **NOTE: this object is deprecated due to re-indexing of the table. |
| dot1agCfmMd | 1.3.111.2.802.1.1.8.1.5 | |||
| NUM dot1agCfmMdTableNextIndex | 1.3.111.2.802.1.1.8.1.5.1 | Dot1afCfmIndexIntegerNextFree | read-only | This object contains an unused value for dot1agCfmMdIndex in the dot1agCfmMdTable, or a zero to indicate that none exist. |
| dot1agCfmMdTable | 1.3.111.2.802.1.1.8.1.5.2 | not-accessible | The Maintenance Domain table. Each row in the table represents a different Maintenance Domain. A Maintenance Domain is described 3.135 as the network or the part of the network for which faults in connectivity are to be managed. The boundary of a Maintenance Domain is defined by a set of DSAPs, each of which can become a point of connectivity to a service instance. | |
| dot1agCfmMdEntry | 1.3.111.2.802.1.1.8.1.5.2.1 | not-accessible | The Maintenance Domain table entry. This entry is not lost upon reboot. It is backed up by stable storage. | |
| U32 dot1agCfmMdIndex | 1.3.111.2.802.1.1.8.1.5.2.1.1 | Unsigned32 | not-accessible | The index to the Maintenance Domain table. dot1agCfmMdTableNextIndex needs to be inspected to find an available index for row-creation. Referential integrity is required, i.e., the index needs to be persistent upon a reboot or restart of a device. The index can never be reused for other Maintenance Domain. The index value SHOULD keep increasing up to the time that they wrap around. This is to facilitate access control based on OID. |
| NUM dot1agCfmMdFormat | 1.3.111.2.802.1.1.8.1.5.2.1.2 | Dot1agCfmMaintDomainNameType | read-create | The type (and thereby format) of the Maintenance Domain Name. |
| NUM dot1agCfmMdName | 1.3.111.2.802.1.1.8.1.5.2.1.3 | Dot1agCfmMaintDomainName | read-create | The Maintenance Domain name. The type/format of this object is determined by the value of the dot1agCfmMdNameType object. Each Maintenance Domain has unique name among all those used or available to a service provider or operator. It facilitates easy identification of administrative responsibility for each Maintenance Domain. 3.140 defines a Maintenance Domain name as the identifier, unique over the domain for which CFM is to protect against accidental concatenation of Service Instances, of a particular Maintenance Domain. |
| DOT dot1agCfmMdMdLevel | 1.3.111.2.802.1.1.8.1.5.2.1.4 | Dot1agCfmMDLevel | read-create | The Maintenance Domain Level. |
| DOT dot1agCfmMdMhfCreation | 1.3.111.2.802.1.1.8.1.5.2.1.5 | Dot1agCfmMhfCreation | read-create | Enumerated value indicating whether the management entity can create MHFs (MIP Half Function) for this Maintenance Domain. Since, in this variable, there is no encompassing Maintenance Domain, the value defMHFdefer is not allowed. |
| DOT dot1agCfmMdMhfIdPermission | 1.3.111.2.802.1.1.8.1.5.2.1.6 | Dot1agCfmIdPermission | read-create | Enumerated value indicating what, if anything, is to be included in the Sender ID TLV (21.5.3) transmitted by MPs configured in this Maintenance Domain. Since, in this variable, there is no encompassing Maintenance Domain, the value sendIdDefer is not allowed. |
| NUM dot1agCfmMdMaNextIndex | 1.3.111.2.802.1.1.8.1.5.2.1.7 | Dot1afCfmIndexIntegerNextFree | read-only | Value to be used as the index of the MA table entries, both the dot1agCfmMaNetTable and the dot1agCfmMaCompTable, for this Maintenance Domain when the management entity wants to create a new row in those tables. |
| ROW dot1agCfmMdRowStatus | 1.3.111.2.802.1.1.8.1.5.2.1.8 | RowStatus | read-create | The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. |
| dot1agCfmMa | 1.3.111.2.802.1.1.8.1.6 | |||
| dot1agCfmMaNetTable | 1.3.111.2.802.1.1.8.1.6.1 | not-accessible | The Maintenance Association table. Each row in the table represents an MA. An MA is a set of MEPs, each configured with a single service instance. This is the part of the complete MA table that is constant across all Bridges in a Maintenance Domain, and across all components of a single Bridge. That part of the MA table that can vary from Bridge component to Bridge component is contained in the dot1agCfmMaCompTable. Creation of a Service Instance establishes a connectionless association among the selected DSAPs. Configuring a Maintenance association Endpoint (MEP) at each of the DSAPs creates a Maintenance Association (MA) to monitor that connectionless connectivity. The MA is identified by a Short MA Name that is unique within the Maintenance Domain and chosen to facilitate easy identification of the Service Instance. Together, the Maintenance Domain Name and the Short MA Name form the Maintenance Association Identifier (MAID) that is carried in CFM Messages to identify incorrect connectivity among Service Instances. A small integer, the Maintenance association Endpoint Identifier (MEPID), identifies each MEP among those configured on a single MA (3.132, 18.2). This table uses two indices, first index is the index of the Maintenance Domain table. The second index is the same as the index of the dot1agCfmMaCompEntry for the same MA. The writable objects in this table need to be persistent upon reboot or restart of a device. | |
| dot1agCfmMaNetEntry | 1.3.111.2.802.1.1.8.1.6.1.1 | not-accessible | The MA table entry. | |
| U32 dot1agCfmMaIndex | 1.3.111.2.802.1.1.8.1.6.1.1.1 | Unsigned32 | not-accessible | Index of the MA table dot1agCfmMdMaNextIndex needs to be inspected to find an available index for row-creation. |
| NUM dot1agCfmMaNetFormat | 1.3.111.2.802.1.1.8.1.6.1.1.2 | Dot1agCfmMaintAssocNameType | read-create | The type (and thereby format) of the Maintenance Association Name. |
| NUM dot1agCfmMaNetName | 1.3.111.2.802.1.1.8.1.6.1.1.3 | Dot1agCfmMaintAssocName | read-create | The Short Maintenance Association name. The type/format of this object is determined by the value of the dot1agCfmMaNetNameType object. This name MUST be unique within a maintenance domain. |
| NUM dot1agCfmMaNetCcmInterval | 1.3.111.2.802.1.1.8.1.6.1.1.4 | Dot1agCfmCcmInterval | read-create | Interval between CCM transmissions to be used by all MEPs in the MA. |
| ROW dot1agCfmMaNetRowStatus | 1.3.111.2.802.1.1.8.1.6.1.1.5 | RowStatus | read-create | The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. |
| dot1agCfmMaCompTable | 1.3.111.2.802.1.1.8.1.6.2 | not-accessible | The Maintenance Association table. Each row in the table represents an MA. An MA is a set of MEPs, each configured with a single service instance. This is the part of the complete MA table that is variable across the Bridges in a Maintenance Domain, or across the components of a single Bridge. That part of the MA table that is constant across the Bridges and their components in a Maintenance Domain is contained in the dot1agCfmMaNetTable. This table uses three indices, first index is the Dot1agCfmPbbComponentIdentifier that identifies the component within the Bridge for which the information in the dot1agCfmMaCompEntry applies. The second is the index of the Maintenance Domain table. The third index is the same as the index of the dot1agCfmMaNetEntry for the same MA. The writable objects in this table need to be persistent upon reboot or restart of a device. **NOTE: this object is deprecated due to re-indexing of the table. | |
| dot1agCfmMaCompEntry | 1.3.111.2.802.1.1.8.1.6.2.1 | not-accessible | The MA table entry. **NOTE: this object is deprecated due to re-indexing of the table. | |
| OID dot1agCfmMaComponentId | 1.3.111.2.802.1.1.8.1.6.2.1.1 | Dot1agCfmPbbComponentIdentifier | not-accessible | The Bridge component within the system to which the information in this dot1agCfmMaCompEntry applies. If the system is not a Bridge, or if only one component is present in the Bridge, then this variable (index) MUST be equal to 1. **NOTE: this object is deprecated due to re-indexing of the table. |
| VLA dot1agCfmMaCompPrimaryVlanId | 1.3.111.2.802.1.1.8.1.6.2.1.2 | VlanIdOrNone | read-create | The Primary VLAN ID with which the Maintenance Association is associated, or 0 if the MA is not attached to any VID. If the MA is associated with more than one VID, the dot1agCfmVlanTable lists them. **NOTE: this object is deprecated due to re-indexing of the table. |
| DOT dot1agCfmMaCompMhfCreation | 1.3.111.2.802.1.1.8.1.6.2.1.3 | Dot1agCfmMhfCreation | read-create | Indicates if the Management entity can create MHFs (MIP Half Function) for this MA. **NOTE: this object is deprecated due to re-indexing of the table. |
| DOT dot1agCfmMaCompIdPermission | 1.3.111.2.802.1.1.8.1.6.2.1.4 | Dot1agCfmIdPermission | read-create | Enumerated value indicating what, if anything, is to be included in the Sender ID TLV (21.5.3) transmitted by MPs configured in this MA. **NOTE: this object is deprecated due to re-indexing of the table. |
| U32 dot1agCfmMaCompNumberOfVids | 1.3.111.2.802.1.1.8.1.6.2.1.5 | Unsigned32 | read-create | The number of VIDs associated with the MA. **NOTE: this object is deprecated due to re-indexing of the table. |
| ROW dot1agCfmMaCompRowStatus | 1.3.111.2.802.1.1.8.1.6.2.1.6 | RowStatus | read-create | The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. **NOTE: this object is deprecated due to re-indexing of the table. |
| dot1agCfmMaMepListTable | 1.3.111.2.802.1.1.8.1.6.3 | not-accessible | List of MEPIDs that belong to this MA. 12.14.6.1.3 specifies that a list of MEPIDs in all Bridges in that MA, but since SNMP SMI does not allow to state in a MIB that an object in a table is an array, the information has to be stored in another table with two indices, being the first index, the index of the table that contains the list or array. For all Bridges in which the same MAID {dot1agCfmMdFormat, dot1agCfmMdName, dot1agCfmMaNetFormat, and dot1agCfmMaNetName} is configured, the same set of dot1agCfmMaMepListIdentifiers MUST be configured in the Bridges' dot1agCfmMaMepListTables. This allows each MEP to determine whether or not it is receiving CCMs from all of the other MEPs in the MA. For example, if one were creating a new MA whose MAID were {charString, 'Dom1', charString, 'MA1'}, that had 2 MEPs, whose MEPIDs were 1 and 3, one could, in Bridge A: 1. Get a new MD index d from dot1agCfmMdTableNextIndex. 2. Create the Maintenance Domain {charString, 'Dom1'}. 3. Get a new MA index a from dot1agCfmMdMaNextIndex [d]. 4. Create the Maintenance Association {charString, 'MA1'}. 5. Create a new dot1agCfmMaMepListEntry for each of the MEPs in the MA: [d, a, 1] and [d, a, 3]. 6. Create one of the new MEPs, say [d, a, 1]. Then, in Bridge B: 7. Do all of these steps 1-6, except for using the other MEPID for the new MEP in Step 6, in this example, MEPID 3. Note that, when creating the MA, MEP List Table, and MEP entries in the second Bridge, the indices 'd' and 'a' identifying the MAID {charString, 'Dom1', charString, 'MA1'} may have different values than those in the first Bridge. | |
| dot1agCfmMaMepListEntry | 1.3.111.2.802.1.1.8.1.6.3.1 | not-accessible | The known MEPS table entry. | |
| DOT dot1agCfmMaMepListIdentifier | 1.3.111.2.802.1.1.8.1.6.3.1.1 | Dot1agCfmMepId | not-accessible | MEPID |
| ROW dot1agCfmMaMepListRowStatus | 1.3.111.2.802.1.1.8.1.6.3.1.2 | RowStatus | read-create | The status of the row. Read SNMPv2-TC (RFC1903) for an explanation of the possible values this object can take. |
| dot1agCfmMep | 1.3.111.2.802.1.1.8.1.7 | |||
| dot1agCfmMepTable | 1.3.111.2.802.1.1.8.1.7.1 | not-accessible | The Maintenance Association Endpoint (MEP) table. Each row in the table represents a different MEP. A MEP is an actively managed CFM entity, associated with a specific DSAP of a Service Instance, which can generate and receive CFM PDUs and track any responses. It is an endpoint of a single Maintenance Association, and is an endpoint of a separate Maintenance Entity for each of the other MEPs in the same Maintenance Association (3.132). This table uses three indices. The first two indices are the indices of the Maintenance Domain and MA tables, the reason being that a MEP is always related to an MA and Maintenance Domain. The MEP table also stores all the managed objects for sending LBM and LTM. *LBM Managed objects LBM Managed objects in the MEP table enables the management entity to initiate transmission of Loopback messages. It will signal the MEP that it SHOULD transmit some number of Loopback messages and detect the detection (or lack thereof) of the corresponding Loopback messages. Steps to use entries in this table: 1) Wait for dot1agCfmMepTransmitLbmStatus value to be false. To do this do this sequence: a. an SNMP GET for both SnmpSetSerialNo and dot1agCfmMepTransmitLbmStatus objects (in same SNMP PDU). b. Check if value for dot1agCfmMepTransmitLbmStatus is false. - if not, wait x seconds, go to step a above. - if yes, save the value of SnmpSetSerialNo and go to step 2) below 2) Change dot1agCfmMepTransmitLbmStatus value from false to true to ensure no other management entity will use the service. In order to not disturb a possible other NMS do this by sending an SNMP SET for both SnmpSetSerialNo and dot1agCfmMepTransmitLbmStatus objects (in same SNMP PDU, and make sure SNmpSetSerialNo is the first varBind). For the SnmpSetSerialNo varBind, use the value that you obtained in step 1)a.. This ensures that two cooperating NMSes will not step on each others toes. Setting this MIB object does not set the corresponding LBIactive state machine variable. 3) Setup the different data to be sent (number of messages, optional TLVs,...), except do not set dot1agCfmMepTransmitLbmMessages. 4) Record the current values of dot1agCfmMepLbrIn, dot1agCfmMepLbrInOutOfOrder, and dot1agCfmMepLbrBadMsdu. 6) Set dot1agCfmMepTransmitLbmMessages to a non-zero value to initiate transmission of Loopback messages. The dot1agCfmMepTransmitLbmMessages indicates the number of LBMs to be sent and is not decremented as loopbacks are actually sent. dot1agCfmMepTransmitLbmMessages is not equivalent to the LBMsToSend state machine variable. 7) Check the value of dot1agCfmMepTransmitLbmResultOK to find out if the operation was successfully initiated or not. 8) Monitor the value of dot1agCfmMepTransmitLbmStatus. When it is reset to false, the last LBM has been transmitted. Wait an additional 5 seconds to ensure that all LBRs have been returned. 9) Compare dot1agCfmMepLbrIn, dot1agCfmMepLbrInOutOfOrder, and dot1agCfmMepLbrBadMsdu to their old values from step 4, above, to get the results of the test. *LTM Managed objects The LTM Managed objects in the MEP table are used in a manner similar to that described for LBM transmission, above. A SET operation to the variable dot1agCfmMepTransmitLtmFlags triggers the transmission of an LTM. Then, the variables dot1agCfmMepTransmitLtmSeqNumber and dot1agCfmMepTransmitLtmEgressIdentifier return the information required to recover the results of the LTM from the dot1agCfmLtrTable. | |
| dot1agCfmMepEntry | 1.3.111.2.802.1.1.8.1.7.1.1 | not-accessible | The MEP table entry | |
| DOT dot1agCfmMepIdentifier | 1.3.111.2.802.1.1.8.1.7.1.1.1 | Dot1agCfmMepId | not-accessible | Integer that is unique among all the MEPs in the same MA. Other definition is: a small integer, unique over a given Maintenance Association, identifying a specific Maintenance association Endpoint (3.132). MEP Identifier is also known as the MEPID. |
| NUM dot1agCfmMepIfIndex | 1.3.111.2.802.1.1.8.1.7.1.1.2 | InterfaceIndexOrZero | read-create | This object is the interface index of the interface either a Bridge Port, or an aggregated IEEE 802.1 link within a Bridge port, to which the MEP is attached. Upon a restart of the system, the system SHALL, if necessary, change the value of this variable so that it indexes the entry in the interface table with the same value of ifAlias that it indexed before the system restart. If no such entry exists, then the system SHALL set this variable to 0. |
| DOT dot1agCfmMepDirection | 1.3.111.2.802.1.1.8.1.7.1.1.3 | Dot1agCfmMpDirection | read-create | The direction in which the MEP faces on the Bridge port. |
| U32 dot1agCfmMepPrimaryVid | 1.3.111.2.802.1.1.8.1.7.1.1.4 | Unsigned32 | read-create | An integer indicating the Primary VID of the MEP, always one of the VIDs assigned to the MEP's MA. The value 0 indicates that either the Primary VID is that of the MEP's MA, or that the MEP's MA is associated with no VID. |
| T/F dot1agCfmMepActive | 1.3.111.2.802.1.1.8.1.7.1.1.5 | TruthValue | read-create | Administrative state of the MEP A Boolean indicating the administrative state of the MEP. True indicates that the MEP is to function normally, and false that it is to cease functioning. |
| DOT dot1agCfmMepFngState | 1.3.111.2.802.1.1.8.1.7.1.1.6 | Dot1agCfmFngState | read-only | Current state of the MEP Fault Notification Generator State Machine. |
| T/F dot1agCfmMepCciEnabled | 1.3.111.2.802.1.1.8.1.7.1.1.7 | TruthValue | read-create | If set to true, the MEP will generate CCM messages. |
| U32 dot1agCfmMepCcmLtmPriority | 1.3.111.2.802.1.1.8.1.7.1.1.8 | Unsigned32 | read-create | The priority value for CCMs and LTMs transmitted by the MEP. Default Value is the highest priority value allowed to pass through the Bridge Port for any of this MEPs VIDs. The management entity can obtain the default value for this variable from the priority regeneration table by extracting the highest priority value in this table on this MEPs Bridge Port. (1 is lowest, then 2, then 0, then 3-7). |
| MAC dot1agCfmMepMacAddress | 1.3.111.2.802.1.1.8.1.7.1.1.9 | MacAddress | read-only | MAC address of the MEP. |
| DOT dot1agCfmMepLowPrDef | 1.3.111.2.802.1.1.8.1.7.1.1.10 | Dot1agCfmLowestAlarmPri | read-create | An integer value specifying the lowest priority defect that is allowed to generate fault alarm. |
| NUM dot1agCfmMepFngAlarmTime | 1.3.111.2.802.1.1.8.1.7.1.1.11 | TimeInterval | read-create | The time that defects MUST be present before a Fault Alarm is issued (fngAlarmTime, 20.3.3) (default 2.5s). |
| NUM dot1agCfmMepFngResetTime | 1.3.111.2.802.1.1.8.1.7.1.1.12 | TimeInterval | read-create | The time that defects MUST be absent before resetting a Fault Alarm (fngResetTime, 20.35.4) (default 10s). |
| DOT dot1agCfmMepHighestPrDefect | 1.3.111.2.802.1.1.8.1.7.1.1.13 | Dot1agCfmHighestDefectPri | read-only | The highest priority defect that has been present since the MEPs Fault Notification Generator State Machine was last in the FNG_RESET state. |
| DOT dot1agCfmMepDefects | 1.3.111.2.802.1.1.8.1.7.1.1.14 | Dot1agCfmMepDefects | read-only | A vector of Boolean error conditions from Table 20-1, any of which may be true: DefRDICCM(0) DefMACstatus(1) DefRemoteCCM(2) DefErrorCCM(3) DefXconCCM(4) |
| OCT dot1agCfmMepErrorCcmLastFailure | 1.3.111.2.802.1.1.8.1.7.1.1.15 | OCTET STRING | read-only | The last-received CCM that triggered an DefErrorCCM fault. |
| OCT dot1agCfmMepXconCcmLastFailure | 1.3.111.2.802.1.1.8.1.7.1.1.16 | OCTET STRING | read-only | The last-received CCM that triggered a DefXconCCM fault. |
| C32 dot1agCfmMepCcmSequenceErrors | 1.3.111.2.802.1.1.8.1.7.1.1.17 | Counter32 | read-only | The total number of out-of-sequence CCMs received from all remote MEPs. |
| C32 dot1agCfmMepCciSentCcms | 1.3.111.2.802.1.1.8.1.7.1.1.18 | Counter32 | read-only | Total number of Continuity Check messages transmitted. |
| U32 dot1agCfmMepNextLbmTransId | 1.3.111.2.802.1.1.8.1.7.1.1.19 | Unsigned32 | read-only | Next sequence number/transaction identifier to be sent in a Loopback message. This sequence number can be zero because it wraps around. |
| C32 dot1agCfmMepLbrIn | 1.3.111.2.802.1.1.8.1.7.1.1.20 | Counter32 | read-only | Total number of valid, in-order Loopback Replies received. |
| C32 dot1agCfmMepLbrInOutOfOrder | 1.3.111.2.802.1.1.8.1.7.1.1.21 | Counter32 | read-only | The total number of valid, out-of-order Loopback Replies received. |
| C32 dot1agCfmMepLbrBadMsdu | 1.3.111.2.802.1.1.8.1.7.1.1.22 | Counter32 | read-only | The total number of LBRs received whose mac_service_data_unit did not match (except for the OpCode) that of the corresponding LBM (20.2.3). |
| U32 dot1agCfmMepLtmNextSeqNumber | 1.3.111.2.802.1.1.8.1.7.1.1.23 | Unsigned32 | read-only | Next transaction identifier/sequence number to be sent in a Linktrace message. This sequence number can be zero because it wraps around. |
| C32 dot1agCfmMepUnexpLtrIn | 1.3.111.2.802.1.1.8.1.7.1.1.24 | Counter32 | read-only | The total number of unexpected LTRs received (20.39.1). |
| C32 dot1agCfmMepLbrOut | 1.3.111.2.802.1.1.8.1.7.1.1.25 | Counter32 | read-only | Total number of Loopback Replies transmitted. |
| T/F dot1agCfmMepTransmitLbmStatus | 1.3.111.2.802.1.1.8.1.7.1.1.26 | TruthValue | read-create | A Boolean flag set to true by the MEP Loopback Initiator State Machine or an MIB manager to indicate that another LBM is being transmitted. Reset to false by the MEP Loopback Initiator State Machine. |
| MAC dot1agCfmMepTransmitLbmDestMacAddress | 1.3.111.2.802.1.1.8.1.7.1.1.27 | MacAddress | read-create | The Target MAC Address Field to be transmitted: A unicast destination MAC address. This address will be used if the value of the column dot1agCfmMepTransmitLbmDestIsMepId is 'false'. |
| DOT dot1agCfmMepTransmitLbmDestMepId | 1.3.111.2.802.1.1.8.1.7.1.1.28 | Dot1agCfmMepIdOrZero | read-create | The Maintenance association Endpoint Identifier of another MEP in the same Maintenance Association to which the LBM is to be sent. This address will be used if the value of the column dot1agCfmMepTransmitLbmDestIsMepId is 'true'. |
| T/F dot1agCfmMepTransmitLbmDestIsMepId | 1.3.111.2.802.1.1.8.1.7.1.1.29 | TruthValue | read-create | True indicates that MEPID of the target MEP is used for Loopback transmission. False indicates that unicast destination MAC address of the target MEP is used for Loopback transmission. |
| I32 dot1agCfmMepTransmitLbmMessages | 1.3.111.2.802.1.1.8.1.7.1.1.30 | Integer32 | read-create | The number of Loopback messages to be transmitted. |
| OCT dot1agCfmMepTransmitLbmDataTlv | 1.3.111.2.802.1.1.8.1.7.1.1.31 | OCTET STRING | read-create | An arbitrary amount of data to be included in the Data TLV, if the Data TLV is selected to be sent. The intent is to be able to fill the frame carrying the CFM PDU to its maximum length. This may lead to fragmentation in some cases. |
| I32 dot1agCfmMepTransmitLbmVlanPriority | 1.3.111.2.802.1.1.8.1.7.1.1.32 | Integer32 | read-create | Priority. 3 bit value to be used in the VLAN tag, if present in the transmitted frame. The default value is CCM priority. |
| T/F dot1agCfmMepTransmitLbmVlanDropEnable | 1.3.111.2.802.1.1.8.1.7.1.1.33 | TruthValue | read-create | Drop Enable bit value to be used in the VLAN tag, if present in the transmitted frame. For more information about VLAN Drop Enable, check IEEE Std 802.1ad. |
| T/F dot1agCfmMepTransmitLbmResultOK | 1.3.111.2.802.1.1.8.1.7.1.1.34 | TruthValue | read-only | Indicates the result of the operation: - true The Loopback Message(s) will be (or has been) sent. - false The Loopback Message(s) will not be sent. |
| U32 dot1agCfmMepTransmitLbmSeqNumber | 1.3.111.2.802.1.1.8.1.7.1.1.35 | Unsigned32 | read-only | The Loopback Transaction Identifier (dot1agCfmMepNextLbmTransId) of the first LBM (to be) sent. The value returned is undefined if dot1agCfmMepTransmitLbmResultOK is false. |
| T/F dot1agCfmMepTransmitLtmStatus | 1.3.111.2.802.1.1.8.1.7.1.1.36 | TruthValue | read-create | A Boolean flag set to true by the Bridge Port to indicate that another LTM may be transmitted. Reset to false by the MEP Linktrace Initiator State Machine. |
| BIT dot1agCfmMepTransmitLtmFlags | 1.3.111.2.802.1.1.8.1.7.1.1.37 | Bits | read-create | The flags field for LTMs transmitted by the MEP. |
| MAC dot1agCfmMepTransmitLtmTargetMacAddress | 1.3.111.2.802.1.1.8.1.7.1.1.38 | MacAddress | read-create | The Target MAC Address Field to be transmitted: A unicast destination MAC address. This address will be used if the value of the column dot1agCfmMepTransmitLtmTargetIsMepId is 'false'. |
| DOT dot1agCfmMepTransmitLtmTargetMepId | 1.3.111.2.802.1.1.8.1.7.1.1.39 | Dot1agCfmMepIdOrZero | read-create | An indication of the Target MAC Address Field to be transmitted: The Maintenance association Endpoint Identifier of another MEP in the same Maintenance Association This address will be used if the value of the column dot1agCfmMepTransmitLtmTargetIsMepId is 'true'. |
| T/F dot1agCfmMepTransmitLtmTargetIsMepId | 1.3.111.2.802.1.1.8.1.7.1.1.40 | TruthValue | read-create | True indicates that MEPID of the target MEP is used for Linktrace transmission. False indicates that unicast destination MAC address of the target MEP is used for Loopback transmission. |
| U32 dot1agCfmMepTransmitLtmTtl | 1.3.111.2.802.1.1.8.1.7.1.1.41 | Unsigned32 | read-create | The LTM TTL field. Default value, if not specified, is 64. The TTL field indicates the number of hops remaining to the LTM. Decremented by 1 by each Linktrace Responder that handles the LTM. The value returned in the LTR is one less than that received in the LTM. If the LTM TTL is 0 or 1, the LTM is not forwarded to the next hop, and if 0, no LTR is generated. |
| T/F dot1agCfmMepTransmitLtmResult | 1.3.111.2.802.1.1.8.1.7.1.1.42 | TruthValue | read-only | Indicates the result of the operation: - true The Linktrace Message will be (or has been) sent. - false The Linktrace Message will not be sent |
| U32 dot1agCfmMepTransmitLtmSeqNumber | 1.3.111.2.802.1.1.8.1.7.1.1.43 | Unsigned32 | read-only | The LTM Transaction Identifier (dot1agCfmMepLtmNextSeqNumber) of the LTM sent. The value returned is undefined if dot1agCfmMepTransmitLtmResult is false. |
| OCT dot1agCfmMepTransmitLtmEgressIdentifier | 1.3.111.2.802.1.1.8.1.7.1.1.44 | OCTET STRING | read-create | Identifies the MEP Linktrace Initiator that is originating, or the Linktrace Responder that is forwarding, this LTM. The low-order six octets contain a 48-bit IEEE MAC address unique to the system in which the MEP Linktrace Initiator or Linktrace Responder resides. The high-order two octets contain a value sufficient to uniquely identify the MEP Linktrace Initiator or Linktrace Responder within that system. For most Bridges, the address of any MAC attached to the Bridge will suffice for the low-order six octets, and 0 for the high-order octets. In some situations, e.g., if multiple virtual Bridges utilizing emulated LANs are implemented in a single physical system, the high-order two octets can be used to differentiate among the transmitting entities. The value returned is undefined if dot1agCfmMepTransmitLtmResult is false. |
| ROW dot1agCfmMepRowStatus | 1.3.111.2.802.1.1.8.1.7.1.1.45 | RowStatus | read-create | The status of the row. The writable columns in a row cannot be changed if the row is active. All columns MUST have a valid value before a row can be activated. |
| T/F dot1agCfmMepPbbTeCanReportPbbTePresence | 1.3.111.2.802.1.1.8.1.7.1.1.46 | TruthValue | read-create | A Boolean valued parameter that is set to true if the system has the capability to report the presence of traffic and that the capability is enabled. Traffic presence reporting is an optional PBB-TE feature. |
| T/F dot1agCfmMepPbbTeTrafficMismatchDefect | 1.3.111.2.802.1.1.8.1.7.1.1.47 | TruthValue | read-only | A Boolean valued parameter that is set to true if the system has detected a traffic field mismatch defect. Mismatch detection is an optional PBB-TE feature. |
| IEE dot1agCfmMepPbbTransmitLbmLtmReverseVid | 1.3.111.2.802.1.1.8.1.7.1.1.48 | IEEE8021VlanIndex | read-create | This column specifies the value to use in the Reverse VID value field of PBB-TE MIP TLVs contained within TransmitLTM pdus. |
| T/F dot1agCfmMepPbbTeMismatchAlarm | 1.3.111.2.802.1.1.8.1.7.1.1.49 | TruthValue | read-create | A Boolean valued parameter that is set to true if the system is to allow a mismatch defect to generate a fault alarm. |
| T/F dot1agCfmMepPbbTeLocalMismatchDefect | 1.3.111.2.802.1.1.8.1.7.1.1.50 | TruthValue | read-only | A Boolean valued parameter that is set to true if the system has detected a local mismatch defect. Mismatch detection is an optional PBB-TE feature. |
| T/F dot1agCfmMepPbbTeMismatchSinceReset | 1.3.111.2.802.1.1.8.1.7.1.1.51 | TruthValue | read-only | A Boolean valued parameter indicating if the mismatch defect has been present since the MEP Mismatch Fault Notification Generator was last in the MFNG_RESET state. |
| dot1agCfmLtrTable | 1.3.111.2.802.1.1.8.1.7.2 | not-accessible | This table extends the MEP table and contains a list of Linktrace replies received by a specific MEP in response to a linktrace message. SNMP SMI does not allow to state in a MIB that an object in a table is an array. The solution is to take the index (or indices) of the first table and add one or more indices. | |
| dot1agCfmLtrEntry | 1.3.111.2.802.1.1.8.1.7.2.1 | not-accessible | The Linktrace Reply table entry. | |
| U32 dot1agCfmLtrSeqNumber | 1.3.111.2.802.1.1.8.1.7.2.1.1 | Unsigned32 | not-accessible | Transaction identifier/Sequence number returned by a previous transmit linktrace message command, indicating which LTM's response is going to be returned. |
| U32 dot1agCfmLtrReceiveOrder | 1.3.111.2.802.1.1.8.1.7.2.1.2 | Unsigned32 | not-accessible | An index to distinguish among multiple LTRs with the same LTR Transaction Identifier field value. dot1agCfmLtrReceiveOrder are assigned sequentially from 1, in the order that the Linktrace Initiator received the LTRs. |
| U32 dot1agCfmLtrTtl | 1.3.111.2.802.1.1.8.1.7.2.1.3 | Unsigned32 | read-only | TTL field value for a returned LTR. |
| T/F dot1agCfmLtrForwarded | 1.3.111.2.802.1.1.8.1.7.2.1.4 | TruthValue | read-only | Indicates if a LTM was forwarded by the responding MP, as returned in the 'FwdYes' flag of the flags field. |
| T/F dot1agCfmLtrTerminalMep | 1.3.111.2.802.1.1.8.1.7.2.1.5 | TruthValue | read-only | A Boolean value stating whether the forwarded LTM reached a MEP enclosing its MA, as returned in the Terminal MEP flag of the Flags field. |
| OCT dot1agCfmLtrLastEgressIdentifier | 1.3.111.2.802.1.1.8.1.7.2.1.6 | OCTET STRING | read-only | An octet field holding the Last Egress Identifier returned in the LTR Egress Identifier TLV of the LTR. The Last Egress Identifier identifies the MEP Linktrace Initiator that originated, or the Linktrace Responder that forwarded, the LTM to which this LTR is the response. This is the same value as the Egress Identifier TLV of that LTM. |
| OCT dot1agCfmLtrNextEgressIdentifier | 1.3.111.2.802.1.1.8.1.7.2.1.7 | OCTET STRING | read-only | An octet field holding the Next Egress Identifier returned in the LTR Egress Identifier TLV of the LTR. The Next Egress Identifier Identifies the Linktrace Responder that transmitted this LTR, and can forward the LTM to the next hop. This is the same value as the Egress Identifier TLV of the forwarded LTM, if any. If the FwdYes bit of the Flags field is false, the contents of this field are undefined, i.e., any value can be transmitted, and the field is ignored by the receiver. |
| DOT dot1agCfmLtrRelay | 1.3.111.2.802.1.1.8.1.7.2.1.8 | Dot1agCfmRelayActionFieldValue | read-only | Value returned in the Relay Action field. |
| LLD dot1agCfmLtrChassisIdSubtype | 1.3.111.2.802.1.1.8.1.7.2.1.9 | LldpChassisIdSubtype | read-only | This object specifies the format of the Chassis ID returned in the Sender ID TLV of the LTR, if any. This value is meaningless if the dot1agCfmLtrChassisId has a length of 0. |
| LLD dot1agCfmLtrChassisId | 1.3.111.2.802.1.1.8.1.7.2.1.10 | LldpChassisId | read-only | The Chassis ID returned in the Sender ID TLV of the LTR, if any. The format of this object is determined by the value of the dot1agCfmLtrChassisIdSubtype object. |
| TDO dot1agCfmLtrManAddressDomain | 1.3.111.2.802.1.1.8.1.7.2.1.11 | TDomain | read-only | The TDomain that identifies the type and format of the related dot1agCfmMepDbManAddress object, used to access the SNMP agent of the system transmitting the LTR. Received in the LTR Sender ID TLV from that system. Typical values will be one of (not all inclusive) list: snmpUDPDomain (from SNMPv2-TM, RFC3417) snmpIeee802Domain (from SNMP-IEEE802-TM-MIB, RFC4789) The value 'zeroDotZero' (from RFC2578) indicates 'no management address was present in the LTR', in which case the related object dot1agCfmMepDbManAddress MUST have a zero-length OCTET STRING as a value. |
| ADR dot1agCfmLtrManAddress | 1.3.111.2.802.1.1.8.1.7.2.1.12 | TAddress | read-only | The TAddress that can be used to access the SNMP agent of the system transmitting the CCM, received in the CCM Sender ID TLV from that system. If the related object dot1agCfmLtrManAddressDomain contains the value 'zeroDotZero', this object dot1agCfmLtrManAddress MUST have a zero-length OCTET STRING as a value. |
| DOT dot1agCfmLtrIngress | 1.3.111.2.802.1.1.8.1.7.2.1.13 | Dot1agCfmIngressActionFieldValue | read-only | The value returned in the Ingress Action Field of the LTM. The value ingNoTlv(0) indicates that no Reply Ingress TLV was returned in the LTM. |
| MAC dot1agCfmLtrIngressMac | 1.3.111.2.802.1.1.8.1.7.2.1.14 | MacAddress | read-only | MAC address returned in the ingress MAC address field. If the dot1agCfmLtrIngress object contains the value ingNoTlv(0), then the contents of this object are meaningless. |
| LLD dot1agCfmLtrIngressPortIdSubtype | 1.3.111.2.802.1.1.8.1.7.2.1.15 | LldpPortIdSubtype | read-only | Format of the Ingress Port ID. If the dot1agCfmLtrIngress object contains the value ingNoTlv(0), then the contents of this object are meaningless. |
| LLD dot1agCfmLtrIngressPortId | 1.3.111.2.802.1.1.8.1.7.2.1.16 | LldpPortId | read-only | Ingress Port ID. The format of this object is determined by the value of the dot1agCfmLtrIngressPortIdSubtype object. If the dot1agCfmLtrIngress object contains the value ingNoTlv(0), then the contents of this object are meaningless. |
| DOT dot1agCfmLtrEgress | 1.3.111.2.802.1.1.8.1.7.2.1.17 | Dot1agCfmEgressActionFieldValue | read-only | The value returned in the Egress Action Field of the LTM. The value egrNoTlv(0) indicates that no Reply Egress TLV was returned in the LTM. |
| MAC dot1agCfmLtrEgressMac | 1.3.111.2.802.1.1.8.1.7.2.1.18 | MacAddress | read-only | MAC address returned in the egress MAC address field. If the dot1agCfmLtrEgress object contains the value egrNoTlv(0), then the contents of this object are meaningless. |
| LLD dot1agCfmLtrEgressPortIdSubtype | 1.3.111.2.802.1.1.8.1.7.2.1.19 | LldpPortIdSubtype | read-only | Format of the egress Port ID. If the dot1agCfmLtrEgress object contains the value egrNoTlv(0), then the contents of this object are meaningless. |
| LLD dot1agCfmLtrEgressPortId | 1.3.111.2.802.1.1.8.1.7.2.1.20 | LldpPortId | read-only | Egress Port ID. The format of this object is determined by the value of the dot1agCfmLtrEgressPortIdSubtype object. If the dot1agCfmLtrEgress object contains the value egrNoTlv(0), then the contents of this object are meaningless. |
| OCT dot1agCfmLtrOrganizationSpecificTlv | 1.3.111.2.802.1.1.8.1.7.2.1.21 | OCTET STRING | read-only | All Organization specific TLVs returned in the LTR, if any. Includes all octets including and following the TLV Length field of each TLV, concatenated together. |
| dot1agCfmMepDbTable | 1.3.111.2.802.1.1.8.1.7.3 | not-accessible | The MEP Database. A database, maintained by every MEP, that maintains received information about other MEPs in the Maintenance Domain. The SMI does not allow to state in a MIB that an object in a table is an array. The solution is to take the index (or indices) of the first table and add one or more indices. | |
| dot1agCfmMepDbEntry | 1.3.111.2.802.1.1.8.1.7.3.1 | not-accessible | The MEP Database table entry. | |
| DOT dot1agCfmMepDbRMepIdentifier | 1.3.111.2.802.1.1.8.1.7.3.1.1 | Dot1agCfmMepId | not-accessible | Maintenance association Endpoint Identifier of a remote MEP whose information from the MEP Database is to be returned. |
| DOT dot1agCfmMepDbRMepState | 1.3.111.2.802.1.1.8.1.7.3.1.2 | Dot1agCfmRemoteMepState | read-only | The operational state of the remote MEP IFF State machines. |
| TIM dot1agCfmMepDbRMepFailedOkTime | 1.3.111.2.802.1.1.8.1.7.3.1.3 | TimeStamp | read-only | The time (SysUpTime) at which the IFF Remote MEP state machine last entered either the RMEP_FAILED or RMEP_OK state. |
| MAC dot1agCfmMepDbMacAddress | 1.3.111.2.802.1.1.8.1.7.3.1.4 | MacAddress | read-only | The MAC address of the remote MEP. |
| T/F dot1agCfmMepDbRdi | 1.3.111.2.802.1.1.8.1.7.3.1.5 | TruthValue | read-only | State of the RDI bit in the last received CCM (true for RDI=1), or false if none has been received. |
| DOT dot1agCfmMepDbPortStatusTlv | 1.3.111.2.802.1.1.8.1.7.3.1.6 | Dot1agCfmPortStatus | read-only | An enumerated value of the Port status TLV received in the last CCM from the remote MEP or the default value psNoPortStateTLV indicating either no CCM has been received, or that nor port status TLV was received in the last CCM. |
| NUM dot1agCfmMepDbInterfaceStatusTlv | 1.3.111.2.802.1.1.8.1.7.3.1.7 | Dot1agCfmInterfaceStatus | read-only | An enumerated value of the Interface status TLV received in the last CCM from the remote MEP or the default value isNoInterfaceStatus TLV indicating either no CCM has been received, or that no interface status TLV was received in the last CCM. |
| LLD dot1agCfmMepDbChassisIdSubtype | 1.3.111.2.802.1.1.8.1.7.3.1.8 | LldpChassisIdSubtype | read-only | This object specifies the format of the Chassis ID received in the last CCM. |
| LLD dot1agCfmMepDbChassisId | 1.3.111.2.802.1.1.8.1.7.3.1.9 | LldpChassisId | read-only | The Chassis ID. The format of this object is determined by the value of the dot1agCfmLtrChassisIdSubtype object. |
| TDO dot1agCfmMepDbManAddressDomain | 1.3.111.2.802.1.1.8.1.7.3.1.10 | TDomain | read-only | The TDomain that identifies the type and format of the related dot1agCfmMepDbManAddress object, used to access the SNMP agent of the system transmitting the CCM. Received in the CCM Sender ID TLV from that system. Typical values will be one of (not all inclusive) list: snmpUDPDomain (from SNMPv2-TM, RFC3417) snmpIeee802Domain (from SNMP-IEEE802-TM-MIB, RFC4789) The value 'zeroDotZero' (from RFC2578) indicates 'no management address was present in the LTR', in which case the related object dot1agCfmMepDbManAddress MUST have a zero-length OCTET STRING as a value. |
| ADR dot1agCfmMepDbManAddress | 1.3.111.2.802.1.1.8.1.7.3.1.11 | TAddress | read-only | The TAddress that can be used to access the SNMP agent of the system transmitting the CCM, received in the CCM Sender ID TLV from that system. If the related object dot1agCfmMepDbManAddressDomain contains the value 'zeroDotZero', this object dot1agCfmMepDbManAddress MUST have a zero-length OCTET STRING as a value. |
| T/F dot1agCfmMepDbRMepIsActive | 1.3.111.2.802.1.1.8.1.7.3.1.12 | TruthValue | read-write | A Boolean value stating if the remote MEP is active. |
| dot1agCfmConformance | 1.3.111.2.802.1.1.8.2 | |||
| dot1agCfmCompliances | 1.3.111.2.802.1.1.8.2.1 | |||
| dot1agCfmCompliance | 1.3.111.2.802.1.1.8.2.1.1 | The compliance statement for support of the CFM MIB module. | ||
| dot1agCfmGroups | 1.3.111.2.802.1.1.8.2.2 | |||
| dot1agCfmStackGroup | 1.3.111.2.802.1.1.8.2.2.1 | Objects for the Stack group. | ||
| dot1agCfmDefaultMdGroup | 1.3.111.2.802.1.1.8.2.2.2 | Objects for the Default MD Level group. | ||
| dot1agCfmVlanIdGroup | 1.3.111.2.802.1.1.8.2.2.3 | Objects for the VLAN ID group. | ||
| dot1agCfmConfigErrorListGroup | 1.3.111.2.802.1.1.8.2.2.4 | Objects for the CFM Configuration Error List Group. | ||
| dot1agCfmMdGroup | 1.3.111.2.802.1.1.8.2.2.5 | Objects for the Maintenance Domain Group. | ||
| dot1agCfmMaGroup | 1.3.111.2.802.1.1.8.2.2.6 | Objects for the MA group. | ||
| dot1agCfmMepGroup | 1.3.111.2.802.1.1.8.2.2.7 | Objects for the MEP group. | ||
| dot1agCfmMepDbGroup | 1.3.111.2.802.1.1.8.2.2.8 | Objects for the MEP group. | ||
| dot1agCfmNotificationsGroup | 1.3.111.2.802.1.1.8.2.2.9 | Objects for the Notifications group. | ||
| ieee8021CfmMaNetGroup | 1.3.111.2.802.1.1.8.2.2.10 | Objects for the MA Net group. | ||
| ieee8021CfmDefaultMdDefGroup | 1.3.111.2.802.1.1.8.2.2.11 | Objects for the Default MD default Level group. | ||
| ieee8021CfmPbbTeExtensionGroup | 1.3.111.2.802.1.1.8.2.2.12 | Objects needed for systems that support PBB-TE CFM functionality. | ||
| ieee8021CfmPbbTeTrafficBitGroup | 1.3.111.2.802.1.1.8.2.2.13 | Objects needed for PBB-TE supporting systems that support the optional traffic bit. |
RFC description
IEEE 802.1 Connectivity Fault Management (CFM) MIB for managing Ethernet OAM and fault detection on bridges.
Start monitoring Vendor-neutral IEEE 802.1ag standard (Carrier Ethernet switch/bridge CFM) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.