CM-ENTITY-MIB

MIB Reference — IPNetwork Monitor

All MIBsCM-ENTITY-MIB

Organization: ADVA Optical Networking SE

Last Updated: 2021-01-27

Category: Optical and WDM

Description:

Provides vendor-specific extensions to the standard ENTITY-MIB for ADVA FSP150CM/CC optical transport product lines, describing physical and logical entities.

Imported Objects

From ADVA-MIB

fsp150cmOBJECT-IDENTITY

From CM-COMMON-MIB

AdminState
CmPmIntervalType
OperationalState
RestartType
SecondaryState
TDMFrequencySourceType
UsbOperationalMode
VlanId

From CM-SYSTEM-MIB

CmAutoProvMode

From ENTITY-MIB

PhysicalIndex

From SNMPv2-CONF

MODULE-COMPLIANCE
OBJECT-GROUP

From SNMPv2-SMI

Integer32
IpAddress
MODULE-IDENTITY
OBJECT-TYPE

From SNMPv2-TC

DateAndTime
DisplayString
RowStatus
StorageType
TEXTUAL-CONVENTION
TruthValue
VariablePointer

What Is CM-ENTITY-MIB?

CM-ENTITY-MIB is ADVA's vendor-specific extension to the standard ENTITY-MIB (RFC 2737), tailored for the F3 (FSP150CM/CC) product line of optical transport/carrier Ethernet devices. It exposes a network-element inventory table describing each managed element's name, type, contact, physical location, and free-text description, along with objects tracking whether a discovered element has been accepted into management and what provisioning action applies to it. This makes it primarily an inventory/asset and provisioning-status MIB: it helps confirm which optical transport network elements are known to the management system, where they are located, and whether they've been formally accepted, which is a form of software/management-state monitoring for the device fleet. As an explicit extension of the standard ENTITY-MIB, it depends on and complements that IETF standard's physical-entity model. It is used in service-provider optical/carrier Ethernet transport networks built on ADVA FSP150CM/CC hardware, and an operator loading this module in a CM-ENTITY-MIB MIB Browser session sees the networkElementTable alongside the acceptance and provisioning objects, giving immediate visibility into which nodes are under management.

IPNetwork Monitor allows you to monitor SNMP objects defined in CM-ENTITY-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

What Can Be Monitored

  • network element name and type
  • network element location and contact info
  • element management-acceptance status
  • element provisioning action state

Supported Devices

  • ADVA FSP150CM optical transport switch
  • ADVA FSP150CC optical transport switch

Monitoring Examples

An operator queries networkElementTable to list managed network elements by neName and neType, and uses neLocation/neContact for asset tracking across a metro optical network. The neAccepted and neProvAction objects indicate whether a newly discovered FSP150 element has been approved into management or is still pending action, which an operator checks when auditing which optical transport nodes are fully under management control after a network expansion.

OIDs
OID symbolicOID numericTypeAccessDescription
cmEntityMIB1.3.6.1.4.1.2544.1.12.3This module defines the Entity MIB definitions used by the F3 (FSP150CM/CC) product lines. These definitions are vendor specific extensions to the standard ENTITY MIB (RFC2737). Copyright (C) ADVA.
cmEntityObjects1.3.6.1.4.1.2544.1.12.3.1
networkElementTable1.3.6.1.4.1.2544.1.12.3.1.1not-accessibleEntries may be auto discovered, or can be explicitly created by SNMP Manager. Each remotely discovered shelf is represented as a row in this table.
networkElementEntry1.3.6.1.4.1.2544.1.12.3.1.1.1not-accessibleA conceptual row in the networkElementTable.
I32 neIndex1.3.6.1.4.1.2544.1.12.3.1.1.1.1Integer32read-onlyAn arbitrary integer index value used to uniquely identify a NetworkElement.
STR neName1.3.6.1.4.1.2544.1.12.3.1.1.1.2DisplayStringread-createAn administratively-assigned name for the Network Element. By convention, this is the node's fully-qualified domain name.
NET neType1.3.6.1.4.1.2544.1.12.3.1.1.1.3NetworkElementTyperead-createType of Network Element.
STR neContact1.3.6.1.4.1.2544.1.12.3.1.1.1.4DisplayStringread-createThe textual identification of the contact person for the Network Element, together with information on how to contact this person.
STR neLocation1.3.6.1.4.1.2544.1.12.3.1.1.1.5DisplayStringread-createThe physical location of this node (e.g., `telephone closet, 3rd floor').
STR neDescription1.3.6.1.4.1.2544.1.12.3.1.1.1.6DisplayStringread-onlyA textual description of the Network Element. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software. It is mandatory that this only contain printable ASCII characters.
STR neCmdPromptPrefix1.3.6.1.4.1.2544.1.12.3.1.1.1.7DisplayStringread-createUser specified command prompt prefix, used by the CLI, at the Network Element level.
T/F neAccepted1.3.6.1.4.1.2544.1.12.3.1.1.1.8TruthValueread-onlyIndicates whether or not the Network Element is accepted or not. When the system's autoProvMode(CM-SYSTEM-MIB) is 'confirm', NetworkElement's are discovered with this object as 'false'. User must invoke the 'accept' action on neProvAction object to accept the NetworkElement.
NUM neFromPort1.3.6.1.4.1.2544.1.12.3.1.1.1.9VariablePointerread-createThe Network Element port to which this Network Element is connected.
NEP neProvAction1.3.6.1.4.1.2544.1.12.3.1.1.1.10NeProvActionread-writeWhen the system's autoProvMode(CM-SYSTEM-MIB) is 'confirm', NetworkElement's are discovered with 'neAccepted' object as 'false'. User must invoke the 'accept' action on this object to accept the NetworkElement. User can invoke the 'decline' action on this object to decline the NetworkElement.
STO neStorageType1.3.6.1.4.1.2544.1.12.3.1.1.1.11StorageTyperead-createThe type of storage configured for this entry.
ROW neRowStatus1.3.6.1.4.1.2544.1.12.3.1.1.1.12RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of neRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with neRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The neRowStatus object may be modified if the associated instance of this object is equal to active(1).
CMA neAutoProvMode1.3.6.1.4.1.2544.1.12.3.1.1.1.13CmAutoProvModeread-createAutoprovisioning mode which controls automatic creation of cards plugged into the slots of Network Element. Supported values are off(1) and auto(3). When neAutoProvMode is auto then the cards inserted into the slots of Network Element will be automatically provisioned. When neAutoProvMode is off no auto-provisioning will occur.
NUM neFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.1.1.14CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the Network Element level. Value of this objec is propagated to all the cards beloning to the Network Element. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
shelfTable1.3.6.1.4.1.2544.1.12.3.1.2not-accessibleContains information on shelf within the NetworkElement. In the case of FSP150CM, there is a single shelf for each NetworkElement.
shelfEntry1.3.6.1.4.1.2544.1.12.3.1.2.1not-accessibleA conceptual row in the shelfTable.
I32 shelfIndex1.3.6.1.4.1.2544.1.12.3.1.2.1.1Integer32read-onlyAn integer index value used to uniquely identify a Shelf within a NetworkElement.
PHY shelfEntityIndex1.3.6.1.4.1.2544.1.12.3.1.2.1.2PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this shelf.
SHE shelfType1.3.6.1.4.1.2544.1.12.3.1.2.1.3ShelfTyperead-writeShelf Type of the shelf.
STR shelfbackplaneRev1.3.6.1.4.1.2544.1.12.3.1.2.1.4DisplayStringread-onlyThe backplane revision number.
DAT shelfbackplaneDOM1.3.6.1.4.1.2544.1.12.3.1.2.1.5DateAndTimeread-onlyBackplane Date of Manufacture.
STR shelfbackplaneSerialNo1.3.6.1.4.1.2544.1.12.3.1.2.1.6DisplayStringread-onlyBackplane Serial Number.
SHE shelfAction1.3.6.1.4.1.2544.1.12.3.1.2.1.7ShelfActionread-writeInvoke action on the shelf, such as lamp test.
ADM shelfAdminState1.3.6.1.4.1.2544.1.12.3.1.2.1.8AdminStateread-writeAdministrative State of the Shelf.
OPE shelfOperationalState1.3.6.1.4.1.2544.1.12.3.1.2.1.9OperationalStateread-onlyOperational State of the Shelf.
SEC shelfSecondaryState1.3.6.1.4.1.2544.1.12.3.1.2.1.10SecondaryStateread-onlySecondary State of the Shelf.
STR shelfMfgSite1.3.6.1.4.1.2544.1.12.3.1.2.1.11DisplayStringread-onlyThis is the shelf's Manufacturer site.
STR shelfOscillatorType1.3.6.1.4.1.2544.1.12.3.1.2.1.12DisplayStringread-onlyThe mOscillatorType.
LED shelfLedControl1.3.6.1.4.1.2544.1.12.3.1.2.1.13LedControlTyperead-writeLed Control of the shelf.
slotTable1.3.6.1.4.1.2544.1.12.3.1.3not-accessibleContains information on slot within the Shelf.
slotEntry1.3.6.1.4.1.2544.1.12.3.1.3.1not-accessibleA conceptual row in the slotTable.
I32 slotIndex1.3.6.1.4.1.2544.1.12.3.1.3.1.1Integer32read-onlyThe actual physical slot index that uniquely identify a Slot within a shelf. Slot number 255 is used to indicate system level entities.
PHY slotEntityIndex1.3.6.1.4.1.2544.1.12.3.1.3.1.2PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this slot.
SLO slotType1.3.6.1.4.1.2544.1.12.3.1.3.1.3SlotTyperead-onlySlot Type of the slot. 'generic' slots can hold NEMI card as well as line cards.
CAR slotCardType1.3.6.1.4.1.2544.1.12.3.1.3.1.4CardTyperead-onlyCard Type of the slot.
STR slotCardUnitName1.3.6.1.4.1.2544.1.12.3.1.3.1.5DisplayStringread-onlyThis is the inserted card's unit name.
STR slotCardFormatVersion1.3.6.1.4.1.2544.1.12.3.1.3.1.6DisplayStringread-onlyThis is the inserted card's format version.
STR slotCardCLEICode1.3.6.1.4.1.2544.1.12.3.1.3.1.7DisplayStringread-onlyThis is the inserted card's CLEI code.
STR slotCardPartNumber1.3.6.1.4.1.2544.1.12.3.1.3.1.8DisplayStringread-onlyThis is the inserted card's Part Number.
STR slotCardHwRev1.3.6.1.4.1.2544.1.12.3.1.3.1.9DisplayStringread-onlyThis is the inserted card's Hardware Revision.
STR slotCardSwRev1.3.6.1.4.1.2544.1.12.3.1.3.1.10DisplayStringread-onlyThis is the inserted card's Software Revision.
STR slotCardSerialNum1.3.6.1.4.1.2544.1.12.3.1.3.1.11DisplayStringread-onlyThis is the inserted card's Serial Number.
STR slotCardMfgName1.3.6.1.4.1.2544.1.12.3.1.3.1.12DisplayStringread-onlyThis is the inserted card's Manufacturer Name.
DAT slotCardMfgDate1.3.6.1.4.1.2544.1.12.3.1.3.1.13DateAndTimeread-onlyThis is the inserted card's Manufacturer date.
STR slotCardMfgSite1.3.6.1.4.1.2544.1.12.3.1.3.1.14DisplayStringread-onlyThis is the inserted card's Manufacturer site.
SEC slotSecondaryState1.3.6.1.4.1.2544.1.12.3.1.3.1.15SecondaryStateread-onlySecondary State of the Slot.
STR slotCardPhysicalAddress1.3.6.1.4.1.2544.1.12.3.1.3.1.16DisplayStringread-onlyThis is the inserted card's MAC Address, if applicable.
psuTable1.3.6.1.4.1.2544.1.12.3.1.4not-accessibleContains information on Power Supply Units within the Shelf.
psuEntry1.3.6.1.4.1.2544.1.12.3.1.4.1not-accessibleA conceptual row in the psuTable.
PHY psuEntityIndex1.3.6.1.4.1.2544.1.12.3.1.4.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this PSU.
PSU psuType1.3.6.1.4.1.2544.1.12.3.1.4.1.2PsuTyperead-onlyPSU Type of the PSU.
ADM psuAdminState1.3.6.1.4.1.2544.1.12.3.1.4.1.3AdminStateread-writeAdministrative State of the PSU.
OPE psuOperationalState1.3.6.1.4.1.2544.1.12.3.1.4.1.4OperationalStateread-onlyOperational State of the PSU.
SEC psuSecondaryState1.3.6.1.4.1.2544.1.12.3.1.4.1.5SecondaryStateread-onlySecondary State of the PSU.
I32 psuOutputVoltage1.3.6.1.4.1.2544.1.12.3.1.4.1.6Integer32read-onlyOutput Voltage of the PSU.
I32 psuTemperature1.3.6.1.4.1.2544.1.12.3.1.4.1.7Integer32read-onlyTemperature of the PSU.
I32 psuOutputCurrent1.3.6.1.4.1.2544.1.12.3.1.4.1.8Integer32read-onlyOutput Current of the PSU.
STO psuStorageType1.3.6.1.4.1.2544.1.12.3.1.4.1.9StorageTyperead-createThe type of storage configured for this entry.
ROW psuRowStatus1.3.6.1.4.1.2544.1.12.3.1.4.1.10RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of psuRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with psuRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The psuRowStatus object may be modified if the associated instance of this object is equal to active(1).
fanTable1.3.6.1.4.1.2544.1.12.3.1.5not-accessibleContains information on FANs within the Shelf.
fanEntry1.3.6.1.4.1.2544.1.12.3.1.5.1not-accessibleA conceptual row in the fanTable.
PHY fanEntityIndex1.3.6.1.4.1.2544.1.12.3.1.5.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this FAN.
ADM fanAdminState1.3.6.1.4.1.2544.1.12.3.1.5.1.2AdminStateread-writeAdministrative State of the FAN.
OPE fanOperationalState1.3.6.1.4.1.2544.1.12.3.1.5.1.3OperationalStateread-onlyOperational State of the FAN.
SEC fanSecondaryState1.3.6.1.4.1.2544.1.12.3.1.5.1.4SecondaryStateread-onlySecondary State of the FAN.
STO fanStorageType1.3.6.1.4.1.2544.1.12.3.1.5.1.5StorageTyperead-createStorage Type of the FAN.
ROW fanRowStatus1.3.6.1.4.1.2544.1.12.3.1.5.1.6RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of fanRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with fanRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The fanRowStatus object may be modified if the associated instance of this object is equal to active(1).
scuTable1.3.6.1.4.1.2544.1.12.3.1.6not-accessibleContains information on SCU within the Shelf.
scuEntry1.3.6.1.4.1.2544.1.12.3.1.6.1not-accessibleA conceptual row in the scuTable.
PHY scuEntityIndex1.3.6.1.4.1.2544.1.12.3.1.6.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the SCU card.
ADM scuAdminState1.3.6.1.4.1.2544.1.12.3.1.6.1.2AdminStateread-writeAdministrative State of the SCU.
OPE scuOperationalState1.3.6.1.4.1.2544.1.12.3.1.6.1.3OperationalStateread-onlyOperational State of the SCU.
SEC scuSecondaryState1.3.6.1.4.1.2544.1.12.3.1.6.1.4SecondaryStateread-onlySecondary State of the SCU.
I32 scuVoltage1.3.6.1.4.1.2544.1.12.3.1.6.1.5Integer32read-onlyVoltage of the SCU.
I32 scuTemperature1.3.6.1.4.1.2544.1.12.3.1.6.1.6Integer32read-onlyTemperature of the SCU.
RES scuRestartAction1.3.6.1.4.1.2544.1.12.3.1.6.1.7RestartTyperead-writeAllows to perform specified action on the SCU card.
STO scuStorageType1.3.6.1.4.1.2544.1.12.3.1.6.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW scuRowStatus1.3.6.1.4.1.2544.1.12.3.1.6.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of scuRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with scuRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The scuRowStatus object may be modified if the associated instance of this object is equal to active(1).
STR scuFlashModelNum1.3.6.1.4.1.2544.1.12.3.1.6.1.10DisplayStringread-onlyThis provides the Compact Flash Model Number on the SCU card.
STR scuFlashFirmwareRev1.3.6.1.4.1.2544.1.12.3.1.6.1.11DisplayStringread-onlyThis provides the Compact Flash Firmware Revision on the SCU card.
STR scuFlashSerialNum1.3.6.1.4.1.2544.1.12.3.1.6.1.12DisplayStringread-onlyThis provides the Compact Flash Serial Number on the SCU card.
nemiTable1.3.6.1.4.1.2544.1.12.3.1.7not-accessibleContains information on NEMI within the Shelf.
nemiEntry1.3.6.1.4.1.2544.1.12.3.1.7.1not-accessibleA conceptual row in the nemiTable.
PHY nemiEntityIndex1.3.6.1.4.1.2544.1.12.3.1.7.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the NEMI card.
ADM nemiAdminState1.3.6.1.4.1.2544.1.12.3.1.7.1.2AdminStateread-writeAdministrative State of the NEMI.
OPE nemiOperationalState1.3.6.1.4.1.2544.1.12.3.1.7.1.3OperationalStateread-onlyOperational State of the NEMI.
SEC nemiSecondaryState1.3.6.1.4.1.2544.1.12.3.1.7.1.4SecondaryStateread-onlySecondary State of the NEMI.
I32 nemiVoltage1.3.6.1.4.1.2544.1.12.3.1.7.1.5Integer32read-onlyVoltage of the NEMI.
I32 nemiTemperature1.3.6.1.4.1.2544.1.12.3.1.7.1.6Integer32read-onlyTemperature of the NEMI.
RES nemiRestartAction1.3.6.1.4.1.2544.1.12.3.1.7.1.7RestartTyperead-writeAllows to perform specified action on the NEMI card.
STO nemiStorageType1.3.6.1.4.1.2544.1.12.3.1.7.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW nemiRowStatus1.3.6.1.4.1.2544.1.12.3.1.7.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of nemiRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with nemiRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The nemiRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F nemiForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.7.1.10TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
STR nemiFlashModelNum1.3.6.1.4.1.2544.1.12.3.1.7.1.11DisplayStringread-onlyThis provides the Flash Model Number on the NEMI card.
STR nemiFlashFirmwareRev1.3.6.1.4.1.2544.1.12.3.1.7.1.12DisplayStringread-onlyThis provides the Flash Firmware Revision on the NEMI card.
STR nemiFlashSerialNum1.3.6.1.4.1.2544.1.12.3.1.7.1.13DisplayStringread-onlyThis provides the Flash Serial Number on the NEMI card.
ethernetNTUCardTable1.3.6.1.4.1.2544.1.12.3.1.8not-accessibleContains information on Ethernet NTU Cards within the Shelf. These cards support 10M, 100M and 1G Ethernet Interfaces.
ethernetNTUCardEntry1.3.6.1.4.1.2544.1.12.3.1.8.1not-accessibleA conceptual row in the ethernetNTUCardTable.
PHY ethernetNTUCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.8.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTU Card.
ADM ethernetNTUCardAdminState1.3.6.1.4.1.2544.1.12.3.1.8.1.2AdminStateread-writeAdministrative State of the Ethernet NTU Card.
OPE ethernetNTUCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.8.1.3OperationalStateread-onlyOperational State of the Ethernet NTU Card.
SEC ethernetNTUCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.8.1.4SecondaryStateread-onlySecondary State of the Ethernet NTU Card.
I32 ethernetNTUCardVoltage1.3.6.1.4.1.2544.1.12.3.1.8.1.5Integer32read-onlyVoltage of the Ethernet NTU Card.
I32 ethernetNTUCardTemperature1.3.6.1.4.1.2544.1.12.3.1.8.1.6Integer32read-onlyTemperature of the Ethernet NTU Card.
T/F ethernetNTUCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.8.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTU Card.
RES ethernetNTUCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.8.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTU card.
STO ethernetNTUCardStorageType1.3.6.1.4.1.2544.1.12.3.1.8.1.9StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetNTUCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.8.1.10RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetNTUCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetNTUCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetNTUCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetCPMRCardTable1.3.6.1.4.1.2544.1.12.3.1.9not-accessibleContains information on Ethernet CPMR Cards within the Shelf.
ethernetCPMRCardEntry1.3.6.1.4.1.2544.1.12.3.1.9.1not-accessibleA conceptual row in the ethernetCPMRCardTable.
PHY ethernetCPMRCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.9.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet CPMR Card.
ADM ethernetCPMRCardAdminState1.3.6.1.4.1.2544.1.12.3.1.9.1.2AdminStateread-writeAdministrative State of the Ethernet CPMR Card.
OPE ethernetCPMRCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.9.1.3OperationalStateread-onlyOperational State of the Ethernet CPMR Card.
SEC ethernetCPMRCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.9.1.4SecondaryStateread-onlySecondary State of the Ethernet CPMR Card.
I32 ethernetCPMRCardVoltage1.3.6.1.4.1.2544.1.12.3.1.9.1.5Integer32read-onlyVoltage of the Ethernet CPMR Card.
I32 ethernetCPMRCardTemperature1.3.6.1.4.1.2544.1.12.3.1.9.1.6Integer32read-onlyTemperature of the Ethernet CPMR Card.
RES ethernetCPMRCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.9.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet CPMR card.
OPE ethernetCPMRCardPSU1State1.3.6.1.4.1.2544.1.12.3.1.9.1.8OperationalStateread-onlyOperational State of Power Supply Unit 1 on Ethernet CPMR chassis.
OPE ethernetCPMRCardPSU2State1.3.6.1.4.1.2544.1.12.3.1.9.1.9OperationalStateread-onlyOperational State of Power Supply Unit 2 on Ethernet CPMR chassis.
OPE ethernetCPMRCardFAN1State1.3.6.1.4.1.2544.1.12.3.1.9.1.10OperationalStateread-onlyOperational State of FAN 1 on Ethernet CPMR chassis.
OPE ethernetCPMRCardFAN2State1.3.6.1.4.1.2544.1.12.3.1.9.1.11OperationalStateread-onlyOperational State of FAN 2 on Ethernet CPMR chassis.
PSU ethernetCPMRCardPsuType1.3.6.1.4.1.2544.1.12.3.1.9.1.12PsuTyperead-onlyPSU Type on Ethernet CPMR chassis.
CMC ethernetCPMRCardLLFMode1.3.6.1.4.1.2544.1.12.3.1.9.1.13CmCPMRLinkLossFwdModeread-onlyCurrent Link Loss Forwarding Mode on CPMR.
CMC ethernetCPMRCardLLFModeAction1.3.6.1.4.1.2544.1.12.3.1.9.1.14CmCPMRLinkLossFwdModeread-writeOperation to set the appropriate mode on CPMR.
ethernetNTEGE101CardTable1.3.6.1.4.1.2544.1.12.3.1.10not-accessibleContains information on Ethernet NTE GE101 Cards. These are supported on the FSP150CC GE101 product.
ethernetNTEGE101CardEntry1.3.6.1.4.1.2544.1.12.3.1.10.1not-accessibleA conceptual row in the ethernetNTEGE101CardTable.
PHY ethernetNTEGE101CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.10.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE101 Card.
ADM ethernetNTEGE101CardAdminState1.3.6.1.4.1.2544.1.12.3.1.10.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE101 Card.
OPE ethernetNTEGE101CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.10.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE101 Card.
SEC ethernetNTEGE101CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.10.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE101 Card.
I32 ethernetNTEGE101CardVoltage1.3.6.1.4.1.2544.1.12.3.1.10.1.5Integer32read-onlyVoltage of the Ethernet NTE GE101 Card.
I32 ethernetNTEGE101CardTemperature1.3.6.1.4.1.2544.1.12.3.1.10.1.6Integer32read-onlyTemperature of the Ethernet NTE GE101 Card.
T/F ethernetNTEGE101CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.10.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE101 Card.
RES ethernetNTEGE101CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.10.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE101 card.
ethernetNTEGE206CardTable1.3.6.1.4.1.2544.1.12.3.1.11not-accessibleContains information on Ethernet NTE GE206 Cards. These are supported on the FSP150CC GE206 product.
ethernetNTEGE206CardEntry1.3.6.1.4.1.2544.1.12.3.1.11.1not-accessibleA conceptual row in the ethernetNTEGE206CardTable.
PHY ethernetNTEGE206CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.11.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE206 Card.
ADM ethernetNTEGE206CardAdminState1.3.6.1.4.1.2544.1.12.3.1.11.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE206 Card.
OPE ethernetNTEGE206CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.11.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE206 Card.
SEC ethernetNTEGE206CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.11.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE206 Card.
I32 ethernetNTEGE206CardVoltage1.3.6.1.4.1.2544.1.12.3.1.11.1.5Integer32read-onlyVoltage of the Ethernet NTE GE206 Card.
I32 ethernetNTEGE206CardTemperature1.3.6.1.4.1.2544.1.12.3.1.11.1.6Integer32read-onlyTemperature of the Ethernet NTE GE206 Card.
T/F ethernetNTEGE206CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.11.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE206 Card.
RES ethernetNTEGE206CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.11.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE206 card.
NUM ethernetNTEGE206CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.11.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
pseudoWireE3CardTable1.3.6.1.4.1.2544.1.12.3.1.12not-accessibleContains information on Pseudo Wire E3 (Emulation Edge to Edge) Cards. These are supported on the FSP150CC GE206 product.
pseudoWireE3CardEntry1.3.6.1.4.1.2544.1.12.3.1.12.1not-accessibleA conceptual row in the pseudoWireE3CardTable.
PHY pseudoWireE3CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.12.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Pseudo Wire E3 Card.
ADM pseudoWireE3CardAdminState1.3.6.1.4.1.2544.1.12.3.1.12.1.2AdminStateread-writeAdministrative State of the Pseudo Wire E3 Card.
OPE pseudoWireE3CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.12.1.3OperationalStateread-onlyOperational State of the Pseudo Wire E3 Card.
SEC pseudoWireE3CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.12.1.4SecondaryStateread-onlySecondary State of the Pseudo Wire E3 Card.
IP pseudoWireE3CardIpAddress1.3.6.1.4.1.2544.1.12.3.1.12.1.5IpAddressread-writeExternal management IP Address of the Pseudo Wire E3 Card.
IP pseudoWireE3CardIpNetmask1.3.6.1.4.1.2544.1.12.3.1.12.1.6IpAddressread-writeExternal management IP Net mask of the Pseudo Wire E3 Card.
IP pseudoWireE3CardIpGateway1.3.6.1.4.1.2544.1.12.3.1.12.1.7IpAddressread-writeExternal management IP Gateway of the Pseudo Wire E3 Card.
T/F pseudoWireE3CardDhcpEnabled1.3.6.1.4.1.2544.1.12.3.1.12.1.8TruthValueread-writeExternal management - whether DHCP is enabled.
VLA pseudoWireE3CardMgmtVlanId1.3.6.1.4.1.2544.1.12.3.1.12.1.9VlanIdread-writeExternal management VLAN Id for the Pseudo Wire E3 Card.
DAT pseudoWireE3CardTimeOfDay1.3.6.1.4.1.2544.1.12.3.1.12.1.10DateAndTimeread-writeTime of day for the Pseudo Wire E3 Card.
RES pseudoWireE3CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.12.1.11RestartTyperead-writeAllows to perform restart action on the Pseudo Wire E3 card.
scuTTable1.3.6.1.4.1.2544.1.12.3.1.13not-accessibleContains information on SCU-T within the Shelf.
scuTEntry1.3.6.1.4.1.2544.1.12.3.1.13.1not-accessibleA conceptual row in the scuTTable.
PHY scuTEntityIndex1.3.6.1.4.1.2544.1.12.3.1.13.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the SCU-T card.
ADM scuTAdminState1.3.6.1.4.1.2544.1.12.3.1.13.1.2AdminStateread-writeAdministrative State of the SCU-T.
OPE scuTOperationalState1.3.6.1.4.1.2544.1.12.3.1.13.1.3OperationalStateread-onlyOperational State of the SCU-T.
SEC scuTSecondaryState1.3.6.1.4.1.2544.1.12.3.1.13.1.4SecondaryStateread-onlySecondary State of the SCU-T.
I32 scuTVoltage1.3.6.1.4.1.2544.1.12.3.1.13.1.5Integer32read-onlyVoltage of the SCU-T.
I32 scuTTemperature1.3.6.1.4.1.2544.1.12.3.1.13.1.6Integer32read-onlyTemperature of the SCU-T.
RES scuTRestartAction1.3.6.1.4.1.2544.1.12.3.1.13.1.7RestartTyperead-writeAllows to perform specified action on the SCU-T card.
STO scuTStorageType1.3.6.1.4.1.2544.1.12.3.1.13.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW scuTRowStatus1.3.6.1.4.1.2544.1.12.3.1.13.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of scuTRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with neRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The scuTRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetNTECardTable1.3.6.1.4.1.2544.1.12.3.1.14not-accessibleContains information on Ethernet NTE Cards within the Shelf. These cards support 10M, 100M and 1G Ethernet Interfaces.
ethernetNTECardEntry1.3.6.1.4.1.2544.1.12.3.1.14.1not-accessibleA conceptual row in the ethernetNTECardTable.
PHY ethernetNTECardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.14.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE Card.
ADM ethernetNTECardAdminState1.3.6.1.4.1.2544.1.12.3.1.14.1.2AdminStateread-writeAdministrative State of the Ethernet NTE Card.
OPE ethernetNTECardOperationalState1.3.6.1.4.1.2544.1.12.3.1.14.1.3OperationalStateread-onlyOperational State of the Ethernet NTE Card.
SEC ethernetNTECardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.14.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE Card.
I32 ethernetNTECardVoltage1.3.6.1.4.1.2544.1.12.3.1.14.1.5Integer32read-onlyVoltage of the Ethernet NTE Card.
I32 ethernetNTECardTemperature1.3.6.1.4.1.2544.1.12.3.1.14.1.6Integer32read-onlyTemperature of the Ethernet NTE Card.
T/F ethernetNTECardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.14.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE Card.
RES ethernetNTECardRestartAction1.3.6.1.4.1.2544.1.12.3.1.14.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE card.
STO ethernetNTECardStorageType1.3.6.1.4.1.2544.1.12.3.1.14.1.9StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetNTECardRowStatus1.3.6.1.4.1.2544.1.12.3.1.14.1.10RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetNTECardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetNTECardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetNTECardRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetNTEGE201CardTable1.3.6.1.4.1.2544.1.12.3.1.15not-accessibleContains information on Ethernet NTE GE201 Cards. These are supported on the FSP150CC GE201 product.
ethernetNTEGE201CardEntry1.3.6.1.4.1.2544.1.12.3.1.15.1not-accessibleA conceptual row in the ethernetNTEGE201CardTable.
PHY ethernetNTEGE201CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.15.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE201 Card.
ADM ethernetNTEGE201CardAdminState1.3.6.1.4.1.2544.1.12.3.1.15.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE201 Card.
OPE ethernetNTEGE201CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.15.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE201 Card.
SEC ethernetNTEGE201CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.15.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE201 Card.
I32 ethernetNTEGE201CardVoltage1.3.6.1.4.1.2544.1.12.3.1.15.1.5Integer32read-onlyVoltage of the Ethernet NTE GE201 Card.
I32 ethernetNTEGE201CardTemperature1.3.6.1.4.1.2544.1.12.3.1.15.1.6Integer32read-onlyTemperature of the Ethernet NTE GE201 Card.
T/F ethernetNTEGE201CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.15.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE201 Card.
RES ethernetNTEGE201CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.15.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE201 card.
NUM ethernetNTEGE201CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.15.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEGE201SyncECardTable1.3.6.1.4.1.2544.1.12.3.1.16not-accessibleContains information on Ethernet NTE GE201SyncE Cards. These are supported on the FSP150CC GE201SyncE product.
ethernetNTEGE201SyncECardEntry1.3.6.1.4.1.2544.1.12.3.1.16.1not-accessibleA conceptual row in the ethernetNTEGE201SyncECardTable.
PHY ethernetNTEGE201SyncECardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.16.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE201SyncE Card.
ADM ethernetNTEGE201SyncECardAdminState1.3.6.1.4.1.2544.1.12.3.1.16.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE201SyncE Card.
OPE ethernetNTEGE201SyncECardOperationalState1.3.6.1.4.1.2544.1.12.3.1.16.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE201SyncE Card.
SEC ethernetNTEGE201SyncECardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.16.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE201SyncE Card.
I32 ethernetNTEGE201SyncECardVoltage1.3.6.1.4.1.2544.1.12.3.1.16.1.5Integer32read-onlyVoltage of the Ethernet NTE GE201SyncE Card.
I32 ethernetNTEGE201SyncECardTemperature1.3.6.1.4.1.2544.1.12.3.1.16.1.6Integer32read-onlyTemperature of the Ethernet NTE GE201SyncE Card.
T/F ethernetNTEGE201SyncECardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.16.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE201SyncE Card.
RES ethernetNTEGE201SyncECardRestartAction1.3.6.1.4.1.2544.1.12.3.1.16.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE201SyncE card.
NUM ethernetNTEGE201SyncECardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.16.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEGE206FCardTable1.3.6.1.4.1.2544.1.12.3.1.17not-accessibleContains information on Ethernet NTE GE206F Cards. These are supported on the FSP150CC GE206 product.
ethernetNTEGE206FCardEntry1.3.6.1.4.1.2544.1.12.3.1.17.1not-accessibleA conceptual row in the ethernetNTEGE206FCardTable.
PHY ethernetNTEGE206FCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.17.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE206 Card.
ADM ethernetNTEGE206FCardAdminState1.3.6.1.4.1.2544.1.12.3.1.17.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE206 Card.
OPE ethernetNTEGE206FCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.17.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE206 Card.
SEC ethernetNTEGE206FCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.17.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE206 Card.
I32 ethernetNTEGE206FCardVoltage1.3.6.1.4.1.2544.1.12.3.1.17.1.5Integer32read-onlyVoltage of the Ethernet NTE GE206 Card.
I32 ethernetNTEGE206FCardTemperature1.3.6.1.4.1.2544.1.12.3.1.17.1.6Integer32read-onlyTemperature of the Ethernet NTE GE206 Card.
T/F ethernetNTEGE206FCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.17.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE206 Card.
RES ethernetNTEGE206FCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.17.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE206 card.
NUM ethernetNTEGE206FCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.17.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernet1x10GCardTable1.3.6.1.4.1.2544.1.12.3.1.18not-accessibleContains information on Ethernet 1x10G Cards.
ethernet1x10GCardEntry1.3.6.1.4.1.2544.1.12.3.1.18.1not-accessibleA conceptual row in the ethernet1x10GCardTable.
PHY ethernet1x10GCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.18.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet 1x10G Card.
ADM ethernet1x10GCardAdminState1.3.6.1.4.1.2544.1.12.3.1.18.1.2AdminStateread-writeAdministrative State of the Ethernet 1x10G Card.
OPE ethernet1x10GCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.18.1.3OperationalStateread-onlyOperational State of the Ethernet 1x10G Card.
SEC ethernet1x10GCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.18.1.4SecondaryStateread-onlySecondary State of the Ethernet 1x10G Card.
I32 ethernet1x10GCardTemperature1.3.6.1.4.1.2544.1.12.3.1.18.1.5Integer32read-onlyTemperature of the Ethernet 1x10G Card.
T/F ethernet1x10GCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.18.1.6TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet 1x10G Card.
RES ethernet1x10GCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.18.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet 1x10G card.
STO ethernet1x10GCardStorageType1.3.6.1.4.1.2544.1.12.3.1.18.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernet1x10GCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.18.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernet1x10GCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetNTUCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernet1x10GCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F ethernet1x10GCardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.18.1.10TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
ethernet10x1GCardTable1.3.6.1.4.1.2544.1.12.3.1.19not-accessibleContains information on Ethernet 10x1G Cards.
ethernet10x1GCardEntry1.3.6.1.4.1.2544.1.12.3.1.19.1not-accessibleA conceptual row in the ethernet10x1GCardTable.
PHY ethernet10x1GCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.19.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet 10x1G Card.
ADM ethernet10x1GCardAdminState1.3.6.1.4.1.2544.1.12.3.1.19.1.2AdminStateread-writeAdministrative State of the Ethernet 10x1G Card.
OPE ethernet10x1GCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.19.1.3OperationalStateread-onlyOperational State of the Ethernet 10x1G Card.
SEC ethernet10x1GCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.19.1.4SecondaryStateread-onlySecondary State of the Ethernet 10x1G Card.
I32 ethernet10x1GCardTemperature1.3.6.1.4.1.2544.1.12.3.1.19.1.5Integer32read-onlyTemperature of the Ethernet 10x1G Card.
T/F ethernet10x1GCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.19.1.6TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet 10x1G Card.
RES ethernet10x1GCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.19.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet 10x1G card.
STO ethernet10x1GCardStorageType1.3.6.1.4.1.2544.1.12.3.1.19.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernet10x1GCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.19.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernet10x1GCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernet10x1GCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernet10x1GCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F ethernet10x1GCardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.19.1.10TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
ethernetSWFCardTable1.3.6.1.4.1.2544.1.12.3.1.20not-accessibleContains information on Ethernet SWF Cards.
ethernetSWFCardEntry1.3.6.1.4.1.2544.1.12.3.1.20.1not-accessibleA conceptual row in the ethernetSWFCardTable.
PHY ethernetSWFCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.20.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet SWF Card.
ADM ethernetSWFCardAdminState1.3.6.1.4.1.2544.1.12.3.1.20.1.2AdminStateread-writeAdministrative State of the Ethernet SWF Card.
OPE ethernetSWFCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.20.1.3OperationalStateread-onlyOperational State of the Ethernet SWF Card.
SEC ethernetSWFCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.20.1.4SecondaryStateread-onlySecondary State of the Ethernet SWF Card.
I32 ethernetSWFCardTemperature1.3.6.1.4.1.2544.1.12.3.1.20.1.5Integer32read-onlyTemperature of the Ethernet SWF Card.
RES ethernetSWFCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.20.1.6RestartTyperead-writeAllows to perform specified action on the Ethernet SWF card.
STO ethernetSWFCardStorageType1.3.6.1.4.1.2544.1.12.3.1.20.1.7StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetSWFCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.20.1.8RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetSWFCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetNTUCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetSWFCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F ethernetSWFCardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.20.1.9TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
stuCardTable1.3.6.1.4.1.2544.1.12.3.1.21not-accessibleContains information on STU Cards.
stuCardEntry1.3.6.1.4.1.2544.1.12.3.1.21.1not-accessibleA conceptual row in the stuCardTable.
PHY stuCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.21.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the STU Card.
ADM stuCardAdminState1.3.6.1.4.1.2544.1.12.3.1.21.1.2AdminStateread-writeAdministrative State of the Stu Card.
OPE stuCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.21.1.3OperationalStateread-onlyOperational State of the Stu Card.
SEC stuCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.21.1.4SecondaryStateread-onlySecondary State of the Stu Card.
I32 stuCardTemperature1.3.6.1.4.1.2544.1.12.3.1.21.1.5Integer32read-onlyTemperature of the Stu Card.
RES stuCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.21.1.6RestartTyperead-writeAllows to perform specified action on the Stu card.
STO stuCardStorageType1.3.6.1.4.1.2544.1.12.3.1.21.1.7StorageTyperead-createThe type of storage configured for this entry.
ROW stuCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.21.1.8RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of stuCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with stuRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The stuCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F stuCardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.21.1.9TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
amiTable1.3.6.1.4.1.2544.1.12.3.1.22not-accessibleContains information on AMI within the Shelf.
amiEntry1.3.6.1.4.1.2544.1.12.3.1.22.1not-accessibleA conceptual row in the amiTable.
PHY amiEntityIndex1.3.6.1.4.1.2544.1.12.3.1.22.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the AMI card.
ADM amiAdminState1.3.6.1.4.1.2544.1.12.3.1.22.1.2AdminStateread-writeAdministrative State of the AMI.
OPE amiOperationalState1.3.6.1.4.1.2544.1.12.3.1.22.1.3OperationalStateread-onlyOperational State of the AMI.
SEC amiSecondaryState1.3.6.1.4.1.2544.1.12.3.1.22.1.4SecondaryStateread-onlySecondary State of the AMI.
I32 amiTemperature1.3.6.1.4.1.2544.1.12.3.1.22.1.5Integer32read-onlyTemperature of the AMI.
RES amiRestartAction1.3.6.1.4.1.2544.1.12.3.1.22.1.6RestartTyperead-writeAllows to perform specified action on the AMI card.
stiTable1.3.6.1.4.1.2544.1.12.3.1.23not-accessibleContains information on STI within the Shelf.
stiEntry1.3.6.1.4.1.2544.1.12.3.1.23.1not-accessibleA conceptual row in the stiTable.
PHY stiEntityIndex1.3.6.1.4.1.2544.1.12.3.1.23.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the STI card.
ADM stiAdminState1.3.6.1.4.1.2544.1.12.3.1.23.1.2AdminStateread-writeAdministrative State of the STI.
OPE stiOperationalState1.3.6.1.4.1.2544.1.12.3.1.23.1.3OperationalStateread-onlyOperational State of the STI.
SEC stiSecondaryState1.3.6.1.4.1.2544.1.12.3.1.23.1.4SecondaryStateread-onlySecondary State of the STI.
I32 stiTemperature1.3.6.1.4.1.2544.1.12.3.1.23.1.5Integer32read-onlyTemperature of the STI.
STO stiStorageType1.3.6.1.4.1.2544.1.12.3.1.23.1.6StorageTyperead-createThe type of storage configured for this entry.
ROW stiRowStatus1.3.6.1.4.1.2544.1.12.3.1.23.1.7RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of stiRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with stiRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The stiRowStatus object may be modified if the associated instance of this object is equal to active(1).
f3UsbHostTable1.3.6.1.4.1.2544.1.12.3.1.24not-accessibleContains information on Usb Host.
f3UsbHostEntry1.3.6.1.4.1.2544.1.12.3.1.24.1not-accessibleA conceptual row in the f3UsbHostTable.
PHY f3UsbHostIndex1.3.6.1.4.1.2544.1.12.3.1.24.1.1PhysicalIndexread-onlyThe actual physical usb host index that uniquely identify a usb host.
PHY f3UsbHostEntityIndex1.3.6.1.4.1.2544.1.12.3.1.24.1.2PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the usb host.
STR f3UsbHostUnitName1.3.6.1.4.1.2544.1.12.3.1.24.1.3DisplayStringread-onlyThis is the inserted usb device's unit name.
STR f3UsbHostFormatVersion1.3.6.1.4.1.2544.1.12.3.1.24.1.4DisplayStringread-onlyThis is the inserted usb device's format version.
STR f3UsbHostCLEICode1.3.6.1.4.1.2544.1.12.3.1.24.1.5DisplayStringread-onlyThis is the inserted usb device's CLEI code.
STR f3UsbHostPartNumber1.3.6.1.4.1.2544.1.12.3.1.24.1.6DisplayStringread-onlyThis is the inserted usb device's Part Number.
STR f3UsbHostHwRev1.3.6.1.4.1.2544.1.12.3.1.24.1.7DisplayStringread-onlyThis is the inserted usb device's Hardware Revision.
STR f3UsbHostSwRev1.3.6.1.4.1.2544.1.12.3.1.24.1.8DisplayStringread-onlyThis is the inserted usb device's Software Revision.
STR f3UsbHostSerialNum1.3.6.1.4.1.2544.1.12.3.1.24.1.9DisplayStringread-onlyThis is the inserted usb device's Serial Number.
STR f3UsbHostMfgName1.3.6.1.4.1.2544.1.12.3.1.24.1.10DisplayStringread-onlyThis is the inserted usb device's Manufacturer Name.
DAT f3UsbHostMfgDate1.3.6.1.4.1.2544.1.12.3.1.24.1.11DateAndTimeread-onlyThis is the inserted usb device's Manufacturer date.
STR f3UsbHostMfgSite1.3.6.1.4.1.2544.1.12.3.1.24.1.12DisplayStringread-onlyThis is the inserted usb device's Manufacturer site.
SEC f3UsbHostSecondaryState1.3.6.1.4.1.2544.1.12.3.1.24.1.13SecondaryStateread-onlySecondary State of the usb device.
STR f3UsbHostPhysicalAddress1.3.6.1.4.1.2544.1.12.3.1.24.1.14DisplayStringread-onlyThis is the inserted usb device's MAC Address, if applicable.
USB f3UsbHostMuxOperationalMode1.3.6.1.4.1.2544.1.12.3.1.24.1.15UsbOperationalModeread-writeThis object describe the USB operatioan mode.
ethernetNTEGE112CardTable1.3.6.1.4.1.2544.1.12.3.1.25not-accessibleContains information on Ethernet NTE GE112 Cards. These are supported on the FSP150CC GE112 product.
ethernetNTEGE112CardEntry1.3.6.1.4.1.2544.1.12.3.1.25.1not-accessibleA conceptual row in the ethernetNTEGE112CardTable.
PHY ethernetNTEGE112CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.25.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE112 Card.
ADM ethernetNTEGE112CardAdminState1.3.6.1.4.1.2544.1.12.3.1.25.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE112 Card.
OPE ethernetNTEGE112CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.25.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE112 Card.
SEC ethernetNTEGE112CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.25.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE112 Card.
I32 ethernetNTEGE112CardVoltage1.3.6.1.4.1.2544.1.12.3.1.25.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112 Card.
I32 ethernetNTEGE112CardTemperature1.3.6.1.4.1.2544.1.12.3.1.25.1.6Integer32read-onlyTemperature of the Ethernet NTE GE112 Card.
T/F ethernetNTEGE112CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.25.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE112 Card.
RES ethernetNTEGE112CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.25.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE112 card.
NUM ethernetNTEGE112CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.25.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE112CardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.25.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE112 card.
SWI ethernetNTEGE112CardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.25.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE112 card.
ethernetNTEGE114CardTable1.3.6.1.4.1.2544.1.12.3.1.26not-accessibleContains information on Ethernet NTE GE114 Cards. These are supported on the FSP150CC GE114 product.
ethernetNTEGE114CardEntry1.3.6.1.4.1.2544.1.12.3.1.26.1not-accessibleA conceptual row in the ethernetNTEGE114CardTable.
PHY ethernetNTEGE114CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.26.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114 Card.
ADM ethernetNTEGE114CardAdminState1.3.6.1.4.1.2544.1.12.3.1.26.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114 Card.
OPE ethernetNTEGE114CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.26.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114 Card.
SEC ethernetNTEGE114CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.26.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114 Card.
I32 ethernetNTEGE114CardVoltage1.3.6.1.4.1.2544.1.12.3.1.26.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112 Card.
I32 ethernetNTEGE114CardTemperature1.3.6.1.4.1.2544.1.12.3.1.26.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114 Card.
T/F ethernetNTEGE114CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.26.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114 Card.
RES ethernetNTEGE114CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.26.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114 card.
NUM ethernetNTEGE114CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.26.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114CardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.26.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114 card.
SWI ethernetNTEGE114CardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.26.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114 card.
ethernetNTEGE206VCardTable1.3.6.1.4.1.2544.1.12.3.1.27not-accessibleContains information on Ethernet NTE GE206V Cards. These are supported on the FSP150CC GE206V product.
ethernetNTEGE206VCardEntry1.3.6.1.4.1.2544.1.12.3.1.27.1not-accessibleA conceptual row in the ethernetNTEGE206VCardTable.
PHY ethernetNTEGE206VCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.27.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE206V Card.
ADM ethernetNTEGE206VCardAdminState1.3.6.1.4.1.2544.1.12.3.1.27.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE206V Card.
OPE ethernetNTEGE206VCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.27.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE206V Card.
SEC ethernetNTEGE206VCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.27.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE206V Card.
I32 ethernetNTEGE206VCardVoltage1.3.6.1.4.1.2544.1.12.3.1.27.1.5Integer32read-onlyVoltage of the Ethernet NTE GE206V Card.
I32 ethernetNTEGE206VCardTemperature1.3.6.1.4.1.2544.1.12.3.1.27.1.6Integer32read-onlyTemperature of the Ethernet NTE GE206V Card.
T/F ethernetNTEGE206VCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.27.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE206V Card.
RES ethernetNTEGE206VCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.27.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE206V card.
NUM ethernetNTEGE206VCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.27.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetGE4SCCCardTable1.3.6.1.4.1.2544.1.12.3.1.28not-accessibleContains information on Ethernet GE206V Optical Port Expander Cards. These are supported on the FSP150CC GE206V product.
ethernetGE4SCCCardEntry1.3.6.1.4.1.2544.1.12.3.1.28.1not-accessibleA conceptual row in the ethernetGE4SCCCardTable.
PHY ethernetGE4SCCCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.28.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet GE-4S Connector Card.
ADM ethernetGE4SCCCardAdminState1.3.6.1.4.1.2544.1.12.3.1.28.1.2AdminStateread-writeAdministrative State of the Ethernet GE-4S Connector Card.
OPE ethernetGE4SCCCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.28.1.3OperationalStateread-onlyOperational State of the Ethernet GE-4S Connector Card.
SEC ethernetGE4SCCCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.28.1.4SecondaryStateread-onlySecondary State of the Ethernet GE-4S Connector Card.
I32 ethernetGE4SCCCardVoltage1.3.6.1.4.1.2544.1.12.3.1.28.1.5Integer32read-onlyVoltage of the Ethernet GE-4S Connector Card.
I32 ethernetGE4SCCCardTemperature1.3.6.1.4.1.2544.1.12.3.1.28.1.6Integer32read-onlyTemperature of the Ethernet GE-4S Connector Card.
RES ethernetGE4SCCCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.28.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet GE-4S Connector card.
STO ethernetGE4SCCCardStorageType1.3.6.1.4.1.2544.1.12.3.1.28.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetGE4SCCCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.28.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetGE4SCCCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetGE4SCCCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetGE4SCCCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetGE4ECCCardTable1.3.6.1.4.1.2544.1.12.3.1.29not-accessibleContains information on Ethernet GE206V Optical Port Expander Cards. These are supported on the FSP150CC GE206V product.
ethernetGE4ECCCardEntry1.3.6.1.4.1.2544.1.12.3.1.29.1not-accessibleA conceptual row in the ethernetGE4ECCCardTable.
PHY ethernetGE4ECCCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.29.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet GE-4S Connector Card.
ADM ethernetGE4ECCCardAdminState1.3.6.1.4.1.2544.1.12.3.1.29.1.2AdminStateread-writeAdministrative State of the Ethernet GE-4S Connector Card.
OPE ethernetGE4ECCCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.29.1.3OperationalStateread-onlyOperational State of the Ethernet GE-4S Connector Card.
SEC ethernetGE4ECCCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.29.1.4SecondaryStateread-onlySecondary State of the Ethernet GE-4S Connector Card.
I32 ethernetGE4ECCCardVoltage1.3.6.1.4.1.2544.1.12.3.1.29.1.5Integer32read-onlyVoltage of the Ethernet GE-4S Connector Card.
I32 ethernetGE4ECCCardTemperature1.3.6.1.4.1.2544.1.12.3.1.29.1.6Integer32read-onlyTemperature of the Ethernet GE-4S Connector Card.
RES ethernetGE4ECCCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.29.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet GE-4S Connector card.
STO ethernetGE4ECCCardStorageType1.3.6.1.4.1.2544.1.12.3.1.29.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetGE4ECCCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.29.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetGE4ECCCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetGE4ECCCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetGE4ECCCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetNTEXG210CardTable1.3.6.1.4.1.2544.1.12.3.1.30not-accessibleContains information on Ethernet NTE XG210 Cards. These are supported on the FSP150CC XG210 product.
ethernetNTEXG210CardEntry1.3.6.1.4.1.2544.1.12.3.1.30.1not-accessibleA conceptual row in the ethernetNTEXG210CardTable.
PHY ethernetNTEXG210CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.30.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE XG210 Card.
ADM ethernetNTEXG210CardAdminState1.3.6.1.4.1.2544.1.12.3.1.30.1.2AdminStateread-writeAdministrative State of the Ethernet NTE XG210 Card.
OPE ethernetNTEXG210CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.30.1.3OperationalStateread-onlyOperational State of the Ethernet NTE XG210 Card.
SEC ethernetNTEXG210CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.30.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE XG210 Card.
I32 ethernetNTEXG210CardVoltage1.3.6.1.4.1.2544.1.12.3.1.30.1.5Integer32read-onlyVoltage of the Ethernet NTE XG210 Card.
I32 ethernetNTEXG210CardTemperature1.3.6.1.4.1.2544.1.12.3.1.30.1.6Integer32read-onlyTemperature of the Ethernet NTE XG210 Card.
T/F ethernetNTEXG210CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.30.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE XG210 Card.
RES ethernetNTEXG210CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.30.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE XG210 card.
NUM ethernetNTEXG210CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.30.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetXG1XCCCardTable1.3.6.1.4.1.2544.1.12.3.1.31not-accessibleContains information on Ethernet XG210/SH1PCS XFP Port Expander Cards. These are supported on the FSP150CC XG210, SH1PCS products.
ethernetXG1XCCCardEntry1.3.6.1.4.1.2544.1.12.3.1.31.1not-accessibleA conceptual row in the ethernetXG1XCCCardTable.
PHY ethernetXG1XCCCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.31.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet XG-1-XFP Connector Card.
ADM ethernetXG1XCCCardAdminState1.3.6.1.4.1.2544.1.12.3.1.31.1.2AdminStateread-writeAdministrative State of the Ethernet XG-1-XFP Connector Card.
OPE ethernetXG1XCCCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.31.1.3OperationalStateread-onlyOperational State of the Ethernet XG-1-XFP Connector Card.
SEC ethernetXG1XCCCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.31.1.4SecondaryStateread-onlySecondary State of the Ethernet XG-1-XFP Connector Card.
I32 ethernetXG1XCCCardVoltage1.3.6.1.4.1.2544.1.12.3.1.31.1.5Integer32read-onlyVoltage of the Ethernet XG-1-XFP Connector Card.
I32 ethernetXG1XCCCardTemperature1.3.6.1.4.1.2544.1.12.3.1.31.1.6Integer32read-onlyTemperature of the Ethernet XG-1-XFP Connector Card.
RES ethernetXG1XCCCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.31.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet XG-1-XFP Connector card.
STO ethernetXG1XCCCardStorageType1.3.6.1.4.1.2544.1.12.3.1.31.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetXG1XCCCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.31.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetXG1XCCCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetXG1XCCCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetXG1XCCCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetXG1SCCCardTable1.3.6.1.4.1.2544.1.12.3.1.32not-accessibleContains information on Ethernet XG210/SH1PCS SFP+ Port Expander Cards. These are supported on the FSP150CC XG210, SH1PCS products.
ethernetXG1SCCCardEntry1.3.6.1.4.1.2544.1.12.3.1.32.1not-accessibleA conceptual row in the ethernetXG1SCCCardTable.
PHY ethernetXG1SCCCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.32.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet XG-1-SFP+ Connector Card.
ADM ethernetXG1SCCCardAdminState1.3.6.1.4.1.2544.1.12.3.1.32.1.2AdminStateread-writeAdministrative State of the Ethernet XG-1-SFP+ Connector Card.
OPE ethernetXG1SCCCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.32.1.3OperationalStateread-onlyOperational State of the Ethernet XG-1-SFP+ Connector Card.
SEC ethernetXG1SCCCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.32.1.4SecondaryStateread-onlySecondary State of the Ethernet XG-1-SFP+ Connector Card.
I32 ethernetXG1SCCCardVoltage1.3.6.1.4.1.2544.1.12.3.1.32.1.5Integer32read-onlyVoltage of the Ethernet XG-1-SFP+ Connector Card.
I32 ethernetXG1SCCCardTemperature1.3.6.1.4.1.2544.1.12.3.1.32.1.6Integer32read-onlyTemperature of the Ethernet XG-1-SFP+ Connector Card.
RES ethernetXG1SCCCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.32.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet XG-1-SFP+ Connector card.
STO ethernetXG1SCCCardStorageType1.3.6.1.4.1.2544.1.12.3.1.32.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetXG1SCCCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.32.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetXG1SCCCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetXG1SCCCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetXG1SCCCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetOverOCSTMCardTable1.3.6.1.4.1.2544.1.12.3.1.33not-accessibleContains information on STM1-4-ET Cards.
ethernetOverOCSTMCardEntry1.3.6.1.4.1.2544.1.12.3.1.33.1not-accessibleA conceptual row in the ethernetOverOCSTMCardTable.
PHY ethernetOverOCSTMCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.33.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the STM1-4-ET Card.
ADM ethernetOverOCSTMCardAdminState1.3.6.1.4.1.2544.1.12.3.1.33.1.2AdminStateread-writeAdministrative State of the STM1-4-ET Card.
OPE ethernetOverOCSTMCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.33.1.3OperationalStateread-onlyOperational State of the STM1-4-ET Card.
SEC ethernetOverOCSTMCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.33.1.4SecondaryStateread-onlySecondary State of the STM1-4-ET Card.
I32 ethernetOverOCSTMCardTemperature1.3.6.1.4.1.2544.1.12.3.1.33.1.5Integer32read-onlyTemperature of the STM1-4-ET Card.
T/F ethernetOverOCSTMCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.33.1.6TruthValueread-writeWhether or not SNMP dying gasp is enabled on the STM1-4-ET Card.
RES ethernetOverOCSTMCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.33.1.7RestartTyperead-writeAllows to perform specified action on the STM1-4-ET card.
STO ethernetOverOCSTMCardStorageType1.3.6.1.4.1.2544.1.12.3.1.33.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetOverOCSTMCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.33.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetOverOCSTMCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernet10x1GCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetOverOCSTMCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F ethernetOverOCSTMCardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.33.1.10TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
POR ethernetOverOCSTMCardMode1.3.6.1.4.1.2544.1.12.3.1.33.1.11PortCarrierTyperead-writeThis attribute is to show/set the SONET/SDH mode and OC3/OC12/STM1/STM4 speed for SONET/SDH..
pseudoWireOcnStmCardTable1.3.6.1.4.1.2544.1.12.3.1.34not-accessibleContains information on Pseudo Wire OCN STM Cards. These are supported on the FSP150CC GE206v product.
pseudoWireOcnStmCardEntry1.3.6.1.4.1.2544.1.12.3.1.34.1not-accessibleA conceptual row in the pseudoWireOcnStmCardTable.
PHY pseudoWireOcnStmCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.34.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Pseudo Wire OCN/STM Card.
ADM pseudoWireOcnStmCardAdminState1.3.6.1.4.1.2544.1.12.3.1.34.1.2AdminStateread-writeAdministrative State of the Pseudo Wire OCN/STM Card.
OPE pseudoWireOcnStmCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.34.1.3OperationalStateread-onlyOperational State of the Pseudo Wire OCN/STM Card.
SEC pseudoWireOcnStmCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.34.1.4SecondaryStateread-onlySecondary State of the Pseudo Wire OCN/STM Card.
IP pseudoWireOcnStmCardIpAddress1.3.6.1.4.1.2544.1.12.3.1.34.1.5IpAddressread-writeIP Address associated with the Pseudo Wire OCN/STM Card.
PWE pseudoWireOcnStmCardMode1.3.6.1.4.1.2544.1.12.3.1.34.1.6PWE3OCNSTMCardModeread-writeCard Mode of with the Pseudo Wire OCN/STM Card.
I32 pseudoWireOcnStmCardVoltage1.3.6.1.4.1.2544.1.12.3.1.34.1.7Integer32read-onlyVoltage of the Pseudo Wire OCN/STM Card.
I32 pseudoWireOcnStmCardTemperature1.3.6.1.4.1.2544.1.12.3.1.34.1.8Integer32read-onlyTemperature of the Pseudo Wire OCN/STM Card.
RES pseudoWireOcnStmCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.34.1.9RestartTyperead-writeAllows to perform specified action on the Pseudo Wire OCN/STM card.
STO pseudoWireOcnStmCardStorageType1.3.6.1.4.1.2544.1.12.3.1.34.1.10StorageTyperead-createThe type of storage configured for this entry.
ROW pseudoWireOcnStmCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.34.1.11RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of pseudoWireOcnStmCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with pseudoWireOcnStmCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The pseudoWireOcnStmCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
PSN pseudoWireOcnStmCardPSNEncapsulation1.3.6.1.4.1.2544.1.12.3.1.34.1.12PSNEncapsulationModeread-writeThis object specifies Packet Switched Network demultiplexing layer header type of the pseudo-wire packets.
TDM pseudoWireOcnStmCardFreqSourceType1.3.6.1.4.1.2544.1.12.3.1.34.1.13TDMFrequencySourceTyperead-writeThis object represents the TDM Frequency source type of OC/STM card.
NUM pseudoWireOcnStmCardFreqSource1.3.6.1.4.1.2544.1.12.3.1.34.1.14VariablePointerread-writeThis object represents the TDM Frequency source of OC/STM card.
T/F pseudoWireOcnStmCardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.34.1.15TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
pseudoWireE1T1CardTable1.3.6.1.4.1.2544.1.12.3.1.35not-accessibleContains information on Pseudo Wire T1/E1 Cards. These are supported on the FSP150CC GE206v product.
pseudoWireE1T1CardEntry1.3.6.1.4.1.2544.1.12.3.1.35.1not-accessibleA conceptual row in the pseudoWireE1T1CardTable.
PHY pseudoWireE1T1CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.35.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Pseudo Wire T1/E1 Card.
ADM pseudoWireE1T1CardAdminState1.3.6.1.4.1.2544.1.12.3.1.35.1.2AdminStateread-writeAdministrative State of the Pseudo Wire T1/E1 Card.
OPE pseudoWireE1T1CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.35.1.3OperationalStateread-onlyOperational State of the Pseudo Wire T1/E1 Card.
SEC pseudoWireE1T1CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.35.1.4SecondaryStateread-onlySecondary State of the Pseudo Wire T1/E1 Card.
IP pseudoWireE1T1CardIpAddress1.3.6.1.4.1.2544.1.12.3.1.35.1.5IpAddressread-writeIP Address associated with the Pseudo Wire T1/E1 Card.
PWE pseudoWireE1T1CardMode1.3.6.1.4.1.2544.1.12.3.1.35.1.6PWE3E1T1CardModeread-writeCard Mode of with the Pseudo Wire T1/E1 Card.
I32 pseudoWireE1T1CardVoltage1.3.6.1.4.1.2544.1.12.3.1.35.1.7Integer32read-onlyVoltage of the Pseudo Wire T1/E1 Card.
I32 pseudoWireE1T1CardTemperature1.3.6.1.4.1.2544.1.12.3.1.35.1.8Integer32read-onlyTemperature of the Pseudo Wire T1/E1 Card.
RES pseudoWireE1T1CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.35.1.9RestartTyperead-writeAllows to perform specified action on the Pseudo Wire T1/E1 card.
STO pseudoWireE1T1CardStorageType1.3.6.1.4.1.2544.1.12.3.1.35.1.10StorageTyperead-createThe type of storage configured for this entry.
ROW pseudoWireE1T1CardRowStatus1.3.6.1.4.1.2544.1.12.3.1.35.1.11RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of pseudoWireE1T1CardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with pseudoWireE1T1CardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The pseudoWireE1T1CardRowStatus object may be modified if the associated instance of this object is equal to active(1).
PSN pseudoWireE1T1CardPSNEncapsulation1.3.6.1.4.1.2544.1.12.3.1.35.1.12PSNEncapsulationModeread-writeThis object specifies Packet Switched Network demultiplexing layer header type of the pseudo-wire packets.
ethernet1x10GHighPerCardTable1.3.6.1.4.1.2544.1.12.3.1.36not-accessibleContains information on Ethernet 1x10G High Performance Cards.
ethernet1x10GHighPerCardEntry1.3.6.1.4.1.2544.1.12.3.1.36.1not-accessibleA conceptual row in the ethernet1x10GHighPerCardTable.
PHY ethernet1x10GHighPerCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.36.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet 1x10G High Performance Card.
ADM ethernet1x10GHighPerCardAdminState1.3.6.1.4.1.2544.1.12.3.1.36.1.2AdminStateread-writeAdministrative State of the Ethernet 1x10G High Performance Card.
OPE ethernet1x10GHighPerCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.36.1.3OperationalStateread-onlyOperational State of the Ethernet 1x10G High Performance Card.
SEC ethernet1x10GHighPerCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.36.1.4SecondaryStateread-onlySecondary State of the Ethernet 1x10G High Performance Card.
I32 ethernet1x10GHighPerCardTemperature1.3.6.1.4.1.2544.1.12.3.1.36.1.5Integer32read-onlyTemperature of the Ethernet 1x10G High Performance Card.
T/F ethernet1x10GHighPerCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.36.1.6TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet 1x10G High Performance Card.
RES ethernet1x10GHighPerCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.36.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet 1x10G High Performance card.
STO ethernet1x10GHighPerCardStorageType1.3.6.1.4.1.2544.1.12.3.1.36.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernet1x10GHighPerCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.36.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernet1x10GHighPerCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetNTUCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernet1x10GHighPerCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F ethernet1x10GHighPerCardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.36.1.10TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
ethernet10x1GHighPerCardTable1.3.6.1.4.1.2544.1.12.3.1.37not-accessibleContains information on Ethernet 10x1G High Performance Cards.
ethernet10x1GHighPerCardEntry1.3.6.1.4.1.2544.1.12.3.1.37.1not-accessibleA conceptual row in the ethernet10x1GHighPerCardTable.
PHY ethernet10x1GHighPerCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.37.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet 10x1G High Performance Card.
ADM ethernet10x1GHighPerCardAdminState1.3.6.1.4.1.2544.1.12.3.1.37.1.2AdminStateread-writeAdministrative State of the Ethernet 10x1G High Performance Card.
OPE ethernet10x1GHighPerCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.37.1.3OperationalStateread-onlyOperational State of the Ethernet 10x1G High Performance Card.
SEC ethernet10x1GHighPerCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.37.1.4SecondaryStateread-onlySecondary State of the Ethernet 10x1G High Performance Card.
I32 ethernet10x1GHighPerCardTemperature1.3.6.1.4.1.2544.1.12.3.1.37.1.5Integer32read-onlyTemperature of the Ethernet 10x1G High Performance Card.
T/F ethernet10x1GHighPerCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.37.1.6TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet 10x1G High Performance Card.
RES ethernet10x1GHighPerCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.37.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet 10x1G High Performance card.
STO ethernet10x1GHighPerCardStorageType1.3.6.1.4.1.2544.1.12.3.1.37.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernet10x1GHighPerCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.37.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernet10x1GHighPerCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernet10x1GHighPerCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernet10x1GHighPerCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F ethernet10x1GHighPerCardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.37.1.10TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
ethernetNTET1804CardTable1.3.6.1.4.1.2544.1.12.3.1.38not-accessibleContains information on Ethernet NTE T1804 Cards. These are supported on the FSP150CC T1804 product.
ethernetNTET1804CardEntry1.3.6.1.4.1.2544.1.12.3.1.38.1not-accessibleA conceptual row in the ethernetNTET1804CardTable.
PHY ethernetNTET1804CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.38.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE T1804 Card.
ADM ethernetNTET1804CardAdminState1.3.6.1.4.1.2544.1.12.3.1.38.1.2AdminStateread-writeAdministrative State of the Ethernet NTE T1804 Card.
OPE ethernetNTET1804CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.38.1.3OperationalStateread-onlyOperational State of the Ethernet NTE T1804 Card.
SEC ethernetNTET1804CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.38.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE T1804 Card.
I32 ethernetNTET1804CardVoltage1.3.6.1.4.1.2544.1.12.3.1.38.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112S Card.
I32 ethernetNTET1804CardTemperature1.3.6.1.4.1.2544.1.12.3.1.38.1.6Integer32read-onlyTemperature of the Ethernet NTE T1804 Card.
T/F ethernetNTET1804CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.38.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE T1804 Card.
RES ethernetNTET1804CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.38.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE T1804 card.
NUM ethernetNTET1804CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.38.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
POR ethernetNTET1804CardMode1.3.6.1.4.1.2544.1.12.3.1.38.1.10PortCarrierTyperead-writeThis attribute is to show/set E1/T1 mode of the NET T1804 card.
ethernetNTET3204CardTable1.3.6.1.4.1.2544.1.12.3.1.39not-accessibleContains information on Ethernet NTE T3204 Cards. These are supported on the FSP150CC T3204 product.
ethernetNTET3204CardEntry1.3.6.1.4.1.2544.1.12.3.1.39.1not-accessibleA conceptual row in the ethernetNTET3204CardTable.
PHY ethernetNTET3204CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.39.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE T3204 Card.
ADM ethernetNTET3204CardAdminState1.3.6.1.4.1.2544.1.12.3.1.39.1.2AdminStateread-writeAdministrative State of the Ethernet NTE T3204 Card.
OPE ethernetNTET3204CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.39.1.3OperationalStateread-onlyOperational State of the Ethernet NTE T3204 Card.
SEC ethernetNTET3204CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.39.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE T3204 Card.
I32 ethernetNTET3204CardVoltage1.3.6.1.4.1.2544.1.12.3.1.39.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112S Card.
I32 ethernetNTET3204CardTemperature1.3.6.1.4.1.2544.1.12.3.1.39.1.6Integer32read-onlyTemperature of the Ethernet NTE T3204 Card.
T/F ethernetNTET3204CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.39.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE T3204 Card.
RES ethernetNTET3204CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.39.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE T3204 card.
NUM ethernetNTET3204CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.39.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
POR ethernetNTET3204CardMode1.3.6.1.4.1.2544.1.12.3.1.39.1.10PortCarrierTyperead-writeThis attribute is to show/set E3/T3 mode of the NET T3204 card.
ethernetNTEGESyncProbeCardTable1.3.6.1.4.1.2544.1.12.3.1.40not-accessibleContains information on Ethernet NTE-GE SyncProbe Card. These are supported on the FSP150CC GE SyncProbe product.
ethernetNTEGESyncProbeCardEntry1.3.6.1.4.1.2544.1.12.3.1.40.1not-accessibleA conceptual row in the ethernetNTEGESyncProbeCardTable.
PHY ethernetNTEGESyncProbeCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.40.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE SyncProbe Card.
ADM ethernetNTEGESyncProbeCardAdminState1.3.6.1.4.1.2544.1.12.3.1.40.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE SyncProbe Card.
OPE ethernetNTEGESyncProbeCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.40.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE SyncProbe Card.
SEC ethernetNTEGESyncProbeCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.40.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE SyncProbe Card.
I32 ethernetNTEGESyncProbeCardVoltage1.3.6.1.4.1.2544.1.12.3.1.40.1.5Integer32read-onlyVoltage of the Ethernet NTE GE SyncProbe Card.
I32 ethernetNTEGESyncProbeCardTemperature1.3.6.1.4.1.2544.1.12.3.1.40.1.6Integer32read-onlyTemperature of the Ethernet NTE GE SyncProbe Card.
T/F ethernetNTEGESyncProbeCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.40.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE SyncProbe Card.
RES ethernetNTEGESyncProbeCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.40.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE SyncProbe card.
NUM ethernetNTEGESyncProbeCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.40.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetGE8SCCCardTable1.3.6.1.4.1.2544.1.12.3.1.41not-accessibleContains information on Ethernet XG210/SH1PCS Optical Port Expander Cards. These are supported on the FSP150CC XG210, SH1PCS product.
ethernetGE8SCCCardEntry1.3.6.1.4.1.2544.1.12.3.1.41.1not-accessibleA conceptual row in the ethernetGE8SCCCardTable.
PHY ethernetGE8SCCCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.41.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet GE-8S Connector Card.
ADM ethernetGE8SCCCardAdminState1.3.6.1.4.1.2544.1.12.3.1.41.1.2AdminStateread-writeAdministrative State of the Ethernet GE-8S Connector Card.
OPE ethernetGE8SCCCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.41.1.3OperationalStateread-onlyOperational State of the Ethernet GE-8S Connector Card.
SEC ethernetGE8SCCCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.41.1.4SecondaryStateread-onlySecondary State of the Ethernet GE-8S Connector Card.
I32 ethernetGE8SCCCardVoltage1.3.6.1.4.1.2544.1.12.3.1.41.1.5Integer32read-onlyVoltage of the Ethernet GE-8S Connector Card.
I32 ethernetGE8SCCCardTemperature1.3.6.1.4.1.2544.1.12.3.1.41.1.6Integer32read-onlyTemperature of the Ethernet GE-8S Connector Card.
RES ethernetGE8SCCCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.41.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet GE-8S Connector card.
STO ethernetGE8SCCCardStorageType1.3.6.1.4.1.2544.1.12.3.1.41.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetGE8SCCCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.41.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetGE8SCCCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetGE8SCCCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetGE8SCCCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetNTEGE114HCardTable1.3.6.1.4.1.2544.1.12.3.1.42not-accessibleContains information on Ethernet NTE GE114H Cards. These are supported on the FSP150CC GE114H product.
ethernetNTEGE114HCardEntry1.3.6.1.4.1.2544.1.12.3.1.42.1not-accessibleA conceptual row in the ethernetNTEGE114HCardTable.
PHY ethernetNTEGE114HCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.42.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114H Card.
ADM ethernetNTEGE114HCardAdminState1.3.6.1.4.1.2544.1.12.3.1.42.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114H Card.
OPE ethernetNTEGE114HCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.42.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114H Card.
SEC ethernetNTEGE114HCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.42.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114H Card.
I32 ethernetNTEGE114HCardVoltage1.3.6.1.4.1.2544.1.12.3.1.42.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112 Card.
I32 ethernetNTEGE114HCardTemperature1.3.6.1.4.1.2544.1.12.3.1.42.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114H Card.
T/F ethernetNTEGE114HCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.42.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114H Card.
RES ethernetNTEGE114HCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.42.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114H card.
NUM ethernetNTEGE114HCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.42.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114HCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.42.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114H card.
SWI ethernetNTEGE114HCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.42.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114H card.
ethernetNTEGE114PHCardTable1.3.6.1.4.1.2544.1.12.3.1.43not-accessibleContains information on Ethernet NTE GE114PH Cards. These are supported on the FSP150CC GE114PH product.
ethernetNTEGE114PHCardEntry1.3.6.1.4.1.2544.1.12.3.1.43.1not-accessibleA conceptual row in the ethernetNTEGE114PHCardTable.
PHY ethernetNTEGE114PHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.43.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114PH Card.
ADM ethernetNTEGE114PHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.43.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114PH Card.
OPE ethernetNTEGE114PHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.43.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114PH Card.
SEC ethernetNTEGE114PHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.43.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114PH Card.
I32 ethernetNTEGE114PHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.43.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112 Card.
I32 ethernetNTEGE114PHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.43.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114PH Card.
T/F ethernetNTEGE114PHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.43.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114PH Card.
RES ethernetNTEGE114PHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.43.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114PH card.
NUM ethernetNTEGE114PHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.43.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114PHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.43.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114PH card.
SWI ethernetNTEGE114PHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.43.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114PH card.
ethernetFE36ECardTable1.3.6.1.4.1.2544.1.12.3.1.44not-accessibleContains information on Ethernet 36x100M Cards.
ethernetFE36ECardEntry1.3.6.1.4.1.2544.1.12.3.1.44.1not-accessibleA conceptual row in the ethernetFE36ECardTable.
PHY ethernetFE36ECardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.44.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet FE36E Card.
ADM ethernetFE36ECardAdminState1.3.6.1.4.1.2544.1.12.3.1.44.1.2AdminStateread-writeAdministrative State of the Ethernet FE36E Card.
OPE ethernetFE36ECardOperationalState1.3.6.1.4.1.2544.1.12.3.1.44.1.3OperationalStateread-onlyOperational State of the Ethernet FE36E Card.
SEC ethernetFE36ECardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.44.1.4SecondaryStateread-onlySecondary State of the Ethernet FE36E Card.
I32 ethernetFE36ECardTemperature1.3.6.1.4.1.2544.1.12.3.1.44.1.5Integer32read-onlyTemperature of the Ethernet FE36E Card.
RES ethernetFE36ECardRestartAction1.3.6.1.4.1.2544.1.12.3.1.44.1.6RestartTyperead-writeAllows to perform specified action on the Ethernet FE36E card.
STO ethernetFE36ECardStorageType1.3.6.1.4.1.2544.1.12.3.1.44.1.7StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetFE36ECardRowStatus1.3.6.1.4.1.2544.1.12.3.1.44.1.8RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetFE36ECardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetNTUCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetFE36ECardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F ethernetFE36ECardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.44.1.9TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
T/F ethernetFE36ECard8023azEnabled1.3.6.1.4.1.2544.1.12.3.1.44.1.10TruthValueread-writeThis object describes whether enable 802.3az energy efficient.
ethernetNTEGE114SHCardTable1.3.6.1.4.1.2544.1.12.3.1.45not-accessibleContains information on Ethernet NTE GE114SH Cards. These are supported on the FSP150CC GE114SH product.
ethernetNTEGE114SHCardEntry1.3.6.1.4.1.2544.1.12.3.1.45.1not-accessibleA conceptual row in the ethernetNTEGE114SHCardTable.
PHY ethernetNTEGE114SHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.45.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114SH Card.
ADM ethernetNTEGE114SHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.45.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114SH Card.
OPE ethernetNTEGE114SHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.45.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114SH Card.
SEC ethernetNTEGE114SHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.45.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114SH Card.
I32 ethernetNTEGE114SHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.45.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112 Card.
I32 ethernetNTEGE114SHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.45.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114SH Card.
T/F ethernetNTEGE114SHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.45.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114SH Card.
RES ethernetNTEGE114SHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.45.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114SH card.
NUM ethernetNTEGE114SHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.45.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114SHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.45.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114SH card.
SWI ethernetNTEGE114SHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.45.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114SH card.
ethernetNTEGE114SCardTable1.3.6.1.4.1.2544.1.12.3.1.46not-accessibleContains information on Ethernet NTE GE114S Cards. These are supported on the FSP150CC GE114S product.
ethernetNTEGE114SCardEntry1.3.6.1.4.1.2544.1.12.3.1.46.1not-accessibleA conceptual row in the ethernetNTEGE114SCardTable.
PHY ethernetNTEGE114SCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.46.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114S Card.
ADM ethernetNTEGE114SCardAdminState1.3.6.1.4.1.2544.1.12.3.1.46.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114S Card.
OPE ethernetNTEGE114SCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.46.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114S Card.
SEC ethernetNTEGE114SCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.46.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114S Card.
I32 ethernetNTEGE114SCardVoltage1.3.6.1.4.1.2544.1.12.3.1.46.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112S Card.
I32 ethernetNTEGE114SCardTemperature1.3.6.1.4.1.2544.1.12.3.1.46.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114S Card.
T/F ethernetNTEGE114SCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.46.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114S Card.
RES ethernetNTEGE114SCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.46.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114S card.
NUM ethernetNTEGE114SCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.46.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114SCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.46.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114S card.
SWI ethernetNTEGE114SCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.46.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114S card.
stuHighPerCardTable1.3.6.1.4.1.2544.1.12.3.1.47not-accessibleContains information on STU Cards.
stuHighPerCardEntry1.3.6.1.4.1.2544.1.12.3.1.47.1not-accessibleA conceptual row in the stuHighPerCardTable.
PHY stuHighPerCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.47.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the STU High Performance Card.
ADM stuHighPerCardAdminState1.3.6.1.4.1.2544.1.12.3.1.47.1.2AdminStateread-writeAdministrative State of the Stu High Performance Card.
OPE stuHighPerCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.47.1.3OperationalStateread-onlyOperational State of the Stu High Performance Card.
SEC stuHighPerCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.47.1.4SecondaryStateread-onlySecondary State of the Stu High Performance Card.
I32 stuHighPerCardTemperature1.3.6.1.4.1.2544.1.12.3.1.47.1.5Integer32read-onlyTemperature of the Stu High Performance Card.
RES stuHighPerCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.47.1.6RestartTyperead-writeAllows to perform specified action on the Stu High Performance card.
STO stuHighPerCardStorageType1.3.6.1.4.1.2544.1.12.3.1.47.1.7StorageTyperead-createThe type of storage configured for this entry.
ROW stuHighPerCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.47.1.8RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of stuHighPerCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with stuRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The stuHighPerCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F stuHighPerCardForceOffLineAction1.3.6.1.4.1.2544.1.12.3.1.47.1.9TruthValueread-writeOn some condition, user wishes to make one card out of service and hold the reset signal of the card via AMI. When force offline is enabled, reset signal is held; When force offline is disabled, reset signal is released.
stiHighPerTable1.3.6.1.4.1.2544.1.12.3.1.48not-accessibleContains information on STI within the Shelf.
stiHighPerEntry1.3.6.1.4.1.2544.1.12.3.1.48.1not-accessibleA conceptual row in the stiTable.
PHY stiHighPerEntityIndex1.3.6.1.4.1.2544.1.12.3.1.48.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the STI High Per card.
ADM stiHighPerAdminState1.3.6.1.4.1.2544.1.12.3.1.48.1.2AdminStateread-writeAdministrative State of the STI.
OPE stiHighPerOperationalState1.3.6.1.4.1.2544.1.12.3.1.48.1.3OperationalStateread-onlyOperational State of the STI.
SEC stiHighPerSecondaryState1.3.6.1.4.1.2544.1.12.3.1.48.1.4SecondaryStateread-onlySecondary State of the STI.
I32 stiHighPerTemperature1.3.6.1.4.1.2544.1.12.3.1.48.1.5Integer32read-onlyTemperature of the STI.
STO stiHighPerStorageType1.3.6.1.4.1.2544.1.12.3.1.48.1.6StorageTyperead-createThe type of storage configured for this entry.
ROW stiHighPerRowStatus1.3.6.1.4.1.2544.1.12.3.1.48.1.7RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of stiRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with stiRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The stiRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetGE8ECCCardTable1.3.6.1.4.1.2544.1.12.3.1.49not-accessibleContains information on Ethernet XG210 Optical Port Expander Cards. These are supported on the FSP150CC XG210, SH1PCS products.
ethernetGE8ECCCardEntry1.3.6.1.4.1.2544.1.12.3.1.49.1not-accessibleA conceptual row in the ethernetGE8ECCCardTable.
PHY ethernetGE8ECCCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.49.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet GE-8S Connector Card.
ADM ethernetGE8ECCCardAdminState1.3.6.1.4.1.2544.1.12.3.1.49.1.2AdminStateread-writeAdministrative State of the Ethernet GE-8S Connector Card.
OPE ethernetGE8ECCCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.49.1.3OperationalStateread-onlyOperational State of the Ethernet GE-8S Connector Card.
SEC ethernetGE8ECCCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.49.1.4SecondaryStateread-onlySecondary State of the Ethernet GE-8S Connector Card.
I32 ethernetGE8ECCCardVoltage1.3.6.1.4.1.2544.1.12.3.1.49.1.5Integer32read-onlyVoltage of the Ethernet GE-8S Connector Card.
I32 ethernetGE8ECCCardTemperature1.3.6.1.4.1.2544.1.12.3.1.49.1.6Integer32read-onlyTemperature of the Ethernet GE-8S Connector Card.
RES ethernetGE8ECCCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.49.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet GE-8S Connector card.
STO ethernetGE8ECCCardStorageType1.3.6.1.4.1.2544.1.12.3.1.49.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetGE8ECCCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.49.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetGE8ECCCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetGE8ECCCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetGE8ECCCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
networkElementLLDPParamsTable1.3.6.1.4.1.2544.1.12.3.1.50not-accessibleEntries may be auto discovered, or can be explicitly created by SNMP Manager. Each remotely discovered shelf is represented as a row in this table.
networkElementLLDPParamsEntry1.3.6.1.4.1.2544.1.12.3.1.50.1not-accessibleA conceptual row in the networkElementLLDPParamsTable.
LLD neLLDPParamsLLDPEnableAction1.3.6.1.4.1.2544.1.12.3.1.50.1.1LLDPEnableActionread-createThis object allows user enable or disable LLDP on all the ports in the NE.
ethernetNTESH1PCSCardTable1.3.6.1.4.1.2544.1.12.3.1.51not-accessibleContains information on Ethernet NTE SH1PCS Cards. These are supported on the FSP150CC SH1PCS product.
ethernetNTESH1PCSCardEntry1.3.6.1.4.1.2544.1.12.3.1.51.1not-accessibleA conceptual row in the ethernetNTESH1PCSCardTable.
PHY ethernetNTESH1PCSCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.51.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE SH1PCS Card.
ADM ethernetNTESH1PCSCardAdminState1.3.6.1.4.1.2544.1.12.3.1.51.1.2AdminStateread-writeAdministrative State of the Ethernet NTE SH1PCS Card.
OPE ethernetNTESH1PCSCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.51.1.3OperationalStateread-onlyOperational State of the Ethernet NTE SH1PCS Card.
SEC ethernetNTESH1PCSCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.51.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE SH1PCS Card.
I32 ethernetNTESH1PCSCardVoltage1.3.6.1.4.1.2544.1.12.3.1.51.1.5Integer32read-onlyVoltage of the Ethernet NTE SH1PCS Card.
I32 ethernetNTESH1PCSCardTemperature1.3.6.1.4.1.2544.1.12.3.1.51.1.6Integer32read-onlyTemperature of the Ethernet NTE SH1PCS Card.
T/F ethernetNTESH1PCSCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.51.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE SH1PCS Card.
RES ethernetNTESH1PCSCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.51.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE SH1PCS card.
NUM ethernetNTESH1PCSCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.51.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEOSA5411CardTable1.3.6.1.4.1.2544.1.12.3.1.52not-accessibleContains information on Ethernet NTE OSA5411 Card. These are supported on the FSP150CC OSA5411 product.
ethernetNTEOSA5411CardEntry1.3.6.1.4.1.2544.1.12.3.1.52.1not-accessibleA conceptual row in the ethernetNTEOSA5411CardTable.
PHY ethernetNTEOSA5411CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.52.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE OSA5411 Card.
ADM ethernetNTEOSA5411CardAdminState1.3.6.1.4.1.2544.1.12.3.1.52.1.2AdminStateread-writeAdministrative State of the Ethernet NTE OSA5411 Card.
OPE ethernetNTEOSA5411CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.52.1.3OperationalStateread-onlyOperational State of the Ethernet NTE OSA5411 Card.
SEC ethernetNTEOSA5411CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.52.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE OSA5411 Card.
I32 ethernetNTEOSA5411CardVoltage1.3.6.1.4.1.2544.1.12.3.1.52.1.5Integer32read-onlyVoltage of the Ethernet NTE OSA5411 Card.
I32 ethernetNTEOSA5411CardTemperature1.3.6.1.4.1.2544.1.12.3.1.52.1.6Integer32read-onlyTemperature of the Ethernet NTE OSA5411 Card.
T/F ethernetNTEOSA5411CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.52.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE OSA5411 Card.
RES ethernetNTEOSA5411CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.52.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE OSA5411 card.
NUM ethernetNTEOSA5411CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.52.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEGE112ProCardTable1.3.6.1.4.1.2544.1.12.3.1.53not-accessibleContains information on Ethernet NTE GE112 Pro Cards. These are supported on the FSP150CC GE112 Pro product.
ethernetNTEGE112ProCardEntry1.3.6.1.4.1.2544.1.12.3.1.53.1not-accessibleA conceptual row in the ethernetNTEGE112ProCardTable.
PHY ethernetNTEGE112ProCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.53.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE112 Pro Card.
ADM ethernetNTEGE112ProCardAdminState1.3.6.1.4.1.2544.1.12.3.1.53.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE112 Pro Card.
OPE ethernetNTEGE112ProCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.53.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE112Pro Card.
SEC ethernetNTEGE112ProCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.53.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE112Pro Card.
I32 ethernetNTEGE112ProCardVoltage1.3.6.1.4.1.2544.1.12.3.1.53.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112Pro Card.
I32 ethernetNTEGE112ProCardTemperature1.3.6.1.4.1.2544.1.12.3.1.53.1.6Integer32read-onlyTemperature of the Ethernet NTE GE112Pro Card.
T/F ethernetNTEGE112ProCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.53.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE112Pro Card.
RES ethernetNTEGE112ProCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.53.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE112Pro card.
NUM ethernetNTEGE112ProCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.53.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE112ProCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.53.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE112Pro card.
SWI ethernetNTEGE112ProCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.53.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE112Pro card.
ethernetNTEGE112ProMCardTable1.3.6.1.4.1.2544.1.12.3.1.54not-accessibleContains information on Ethernet NTE GE112 Pro Cards. These are supported on the FSP150CC GE112 Pro product.
ethernetNTEGE112ProMCardEntry1.3.6.1.4.1.2544.1.12.3.1.54.1not-accessibleA conceptual row in the ethernetNTEGE112ProMCardTable.
PHY ethernetNTEGE112ProMCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.54.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE112 Pro Card.
ADM ethernetNTEGE112ProMCardAdminState1.3.6.1.4.1.2544.1.12.3.1.54.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE112 Pro Card.
OPE ethernetNTEGE112ProMCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.54.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE112ProM Card.
SEC ethernetNTEGE112ProMCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.54.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE112ProM Card.
I32 ethernetNTEGE112ProMCardVoltage1.3.6.1.4.1.2544.1.12.3.1.54.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112ProM Card.
I32 ethernetNTEGE112ProMCardTemperature1.3.6.1.4.1.2544.1.12.3.1.54.1.6Integer32read-onlyTemperature of the Ethernet NTE GE112ProM Card.
T/F ethernetNTEGE112ProMCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.54.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE112ProM Card.
RES ethernetNTEGE112ProMCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.54.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE112ProM card.
NUM ethernetNTEGE112ProMCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.54.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE112ProMCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.54.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE112ProM card.
SWI ethernetNTEGE112ProMCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.54.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE112ProM card.
ethernetNTEXG210CCardTable1.3.6.1.4.1.2544.1.12.3.1.55not-accessibleContains information on Ethernet NTE XG210 Cards. These are supported on the FSP150CC XG210 product.
ethernetNTEXG210CCardEntry1.3.6.1.4.1.2544.1.12.3.1.55.1not-accessibleA conceptual row in the ethernetNTEXG210CCardTable.
PHY ethernetNTEXG210CCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.55.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE XG210C Card.
ADM ethernetNTEXG210CCardAdminState1.3.6.1.4.1.2544.1.12.3.1.55.1.2AdminStateread-writeAdministrative State of the Ethernet NTE XG210C Card.
OPE ethernetNTEXG210CCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.55.1.3OperationalStateread-onlyOperational State of the Ethernet NTE XG210C Card.
SEC ethernetNTEXG210CCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.55.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE XG210C Card.
I32 ethernetNTEXG210CCardVoltage1.3.6.1.4.1.2544.1.12.3.1.55.1.5Integer32read-onlyVoltage of the Ethernet NTE XG210C Card.
I32 ethernetNTEXG210CCardTemperature1.3.6.1.4.1.2544.1.12.3.1.55.1.6Integer32read-onlyTemperature of the Ethernet NTE XG210C Card.
T/F ethernetNTEXG210CCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.55.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE XG210C Card.
RES ethernetNTEXG210CCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.55.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE XG210 card.
NUM ethernetNTEXG210CCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.55.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetGE8SCryptoConnectorCardTable1.3.6.1.4.1.2544.1.12.3.1.56not-accessibleContains information on Ethernet XG210C Optical Port Expander Cards. These are supported on the XG210C MACSEC board.
ethernetGE8SCryptoConnectorCardEntry1.3.6.1.4.1.2544.1.12.3.1.56.1not-accessibleA conceptual row in the ethernetGE8SCryptoConnectorCardTable.
PHY ethernetGE8SCryptoConnectorCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.56.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet GE-8SC Connector Card.
ADM ethernetGE8SCryptoConnectorCardAdminState1.3.6.1.4.1.2544.1.12.3.1.56.1.2AdminStateread-writeAdministrative State of the Ethernet GE-8SC Connector Card.
OPE ethernetGE8SCryptoConnectorCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.56.1.3OperationalStateread-onlyOperational State of the Ethernet GE-8SC Connector Card.
SEC ethernetGE8SCryptoConnectorCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.56.1.4SecondaryStateread-onlySecondary State of the Ethernet GE-8SC Connector Card.
I32 ethernetGE8SCryptoConnectorCardVoltage1.3.6.1.4.1.2544.1.12.3.1.56.1.5Integer32read-onlyVoltage of the Ethernet GE-8SC Connector Card.
I32 ethernetGE8SCryptoConnectorCardTemperature1.3.6.1.4.1.2544.1.12.3.1.56.1.6Integer32read-onlyTemperature of the Ethernet GE-8SC Connector Card.
RES ethernetGE8SCryptoConnectorCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.56.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet GE-8SC Connector card.
STO ethernetGE8SCryptoConnectorCardStorageType1.3.6.1.4.1.2544.1.12.3.1.56.1.8StorageTyperead-createThe type of storage configured for this entry.
ROW ethernetGE8SCryptoConnectorCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.56.1.9RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ethernetGE8SCryptoConnectorCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ethernetGE8SCryptoConnectorCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ethernetGE8SCryptoConnectorCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
ethernetNTEGE114ProCardTable1.3.6.1.4.1.2544.1.12.3.1.57not-accessibleContains information on Ethernet NTE GE112 Pro Cards. These are supported on the FSP150CC GE112 Pro product.
ethernetNTEGE114ProCardEntry1.3.6.1.4.1.2544.1.12.3.1.57.1not-accessibleA conceptual row in the ethernetNTEGE114ProCardTable.
PHY ethernetNTEGE114ProCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.57.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE112 Pro Card.
ADM ethernetNTEGE114ProCardAdminState1.3.6.1.4.1.2544.1.12.3.1.57.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE112 Pro Card.
OPE ethernetNTEGE114ProCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.57.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114Pro Card.
SEC ethernetNTEGE114ProCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.57.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114Pro Card.
I32 ethernetNTEGE114ProCardVoltage1.3.6.1.4.1.2544.1.12.3.1.57.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114Pro Card.
I32 ethernetNTEGE114ProCardTemperature1.3.6.1.4.1.2544.1.12.3.1.57.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114Pro Card.
T/F ethernetNTEGE114ProCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.57.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114Pro Card.
RES ethernetNTEGE114ProCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.57.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114Pro card.
NUM ethernetNTEGE114ProCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.57.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114ProCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.57.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114Pro card.
SWI ethernetNTEGE114ProCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.57.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114Pro card.
ethernetNTEGE114ProCCardTable1.3.6.1.4.1.2544.1.12.3.1.58not-accessibleContains information on Ethernet NTE GE112 Pro Cards. These are supported on the FSP150CC GE112 Pro product.
ethernetNTEGE114ProCCardEntry1.3.6.1.4.1.2544.1.12.3.1.58.1not-accessibleA conceptual row in the ethernetNTEGE114ProCCardTable.
PHY ethernetNTEGE114ProCCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.58.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE112 Pro Card.
ADM ethernetNTEGE114ProCCardAdminState1.3.6.1.4.1.2544.1.12.3.1.58.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE112 Pro Card.
OPE ethernetNTEGE114ProCCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.58.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114ProC Card.
SEC ethernetNTEGE114ProCCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.58.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114ProC Card.
I32 ethernetNTEGE114ProCCardVoltage1.3.6.1.4.1.2544.1.12.3.1.58.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114ProC Card.
I32 ethernetNTEGE114ProCCardTemperature1.3.6.1.4.1.2544.1.12.3.1.58.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114ProC Card.
T/F ethernetNTEGE114ProCCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.58.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114ProC Card.
RES ethernetNTEGE114ProCCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.58.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114ProC card.
NUM ethernetNTEGE114ProCCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.58.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114ProCCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.58.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114ProC card.
SWI ethernetNTEGE114ProCCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.58.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114ProC card.
ethernetNTEGE114ProSHCardTable1.3.6.1.4.1.2544.1.12.3.1.59not-accessibleContains information on Ethernet NTE GE112 Pro Cards. These are supported on the FSP150CC GE112 Pro product.
ethernetNTEGE114ProSHCardEntry1.3.6.1.4.1.2544.1.12.3.1.59.1not-accessibleA conceptual row in the ethernetNTEGE114ProSHCardTable.
PHY ethernetNTEGE114ProSHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.59.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE112 Pro Card.
ADM ethernetNTEGE114ProSHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.59.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE112 Pro Card.
OPE ethernetNTEGE114ProSHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.59.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114ProS Card.
SEC ethernetNTEGE114ProSHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.59.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114ProS Card.
I32 ethernetNTEGE114ProSHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.59.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114ProS Card.
I32 ethernetNTEGE114ProSHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.59.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114ProS Card.
T/F ethernetNTEGE114ProSHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.59.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114ProS Card.
RES ethernetNTEGE114ProSHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.59.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114ProS card.
NUM ethernetNTEGE114ProSHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.59.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114ProSHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.59.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114ProSH card.
SWI ethernetNTEGE114ProSHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.59.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114ProSH card.
ethernetNTEGE114ProCSHCardTable1.3.6.1.4.1.2544.1.12.3.1.60not-accessibleContains information on Ethernet NTE GE112 Pro Cards. These are supported on the FSP150CC GE112 Pro product.
ethernetNTEGE114ProCSHCardEntry1.3.6.1.4.1.2544.1.12.3.1.60.1not-accessibleA conceptual row in the ethernetNTEGE114ProCSHCardTable.
PHY ethernetNTEGE114ProCSHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.60.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE112 Pro Card.
ADM ethernetNTEGE114ProCSHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.60.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE112 Pro Card.
OPE ethernetNTEGE114ProCSHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.60.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114ProCS Card.
SEC ethernetNTEGE114ProCSHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.60.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114ProCS Card.
I32 ethernetNTEGE114ProCSHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.60.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114ProCS Card.
I32 ethernetNTEGE114ProCSHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.60.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114ProCS Card.
T/F ethernetNTEGE114ProCSHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.60.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114ProCS Card.
RES ethernetNTEGE114ProCSHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.60.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114ProCS card.
NUM ethernetNTEGE114ProCSHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.60.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114ProCSHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.60.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114ProCS card.
SWI ethernetNTEGE114ProCSHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.60.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114ProCS card.
ethernetNTEGE114ProHECardTable1.3.6.1.4.1.2544.1.12.3.1.61not-accessibleContains information on Ethernet NTE GE112 Pro Cards. These are supported on the FSP150CC GE112 Pro product.
ethernetNTEGE114ProHECardEntry1.3.6.1.4.1.2544.1.12.3.1.61.1not-accessibleA conceptual row in the ethernetNTEGE114ProHECardTable.
PHY ethernetNTEGE114ProHECardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.61.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE112 Pro Card.
ADM ethernetNTEGE114ProHECardAdminState1.3.6.1.4.1.2544.1.12.3.1.61.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE112 Pro Card.
OPE ethernetNTEGE114ProHECardOperationalState1.3.6.1.4.1.2544.1.12.3.1.61.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114ProHE Card.
SEC ethernetNTEGE114ProHECardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.61.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114ProHE Card.
I32 ethernetNTEGE114ProHECardVoltage1.3.6.1.4.1.2544.1.12.3.1.61.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114ProHE Card.
I32 ethernetNTEGE114ProHECardTemperature1.3.6.1.4.1.2544.1.12.3.1.61.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114ProHE Card.
T/F ethernetNTEGE114ProHECardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.61.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114ProHE Card.
RES ethernetNTEGE114ProHECardRestartAction1.3.6.1.4.1.2544.1.12.3.1.61.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114ProHE card.
NUM ethernetNTEGE114ProHECardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.61.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114ProHECardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.61.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114ProHE card.
SWI ethernetNTEGE114ProHECardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.61.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114ProHE card.
ethernetNTEGE112ProHCardTable1.3.6.1.4.1.2544.1.12.3.1.62not-accessibleContains information on Ethernet NTE GE112 Pro Cards. These are supported on the FSP150CC GE112 Pro product.
ethernetNTEGE112ProHCardEntry1.3.6.1.4.1.2544.1.12.3.1.62.1not-accessibleA conceptual row in the ethernetNTEGE112ProHCardTable.
PHY ethernetNTEGE112ProHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.62.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE112 Pro Card.
ADM ethernetNTEGE112ProHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.62.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE112 Pro Card.
OPE ethernetNTEGE112ProHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.62.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE112ProH Card.
SEC ethernetNTEGE112ProHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.62.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE112ProH Card.
I32 ethernetNTEGE112ProHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.62.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112ProH Card.
I32 ethernetNTEGE112ProHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.62.1.6Integer32read-onlyTemperature of the Ethernet NTE GE112ProH Card.
T/F ethernetNTEGE112ProHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.62.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE112ProH Card.
RES ethernetNTEGE112ProHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.62.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE112ProH card.
NUM ethernetNTEGE112ProHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.62.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE112ProHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.62.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE112ProH card.
SWI ethernetNTEGE112ProHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.62.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE112ProH card.
ethernetNTEOSA5420CardTable1.3.6.1.4.1.2544.1.12.3.1.63not-accessibleContains information on Ethernet NTE OSA5420 Card. These are supported on the FSP150CC OSA5420 product.
ethernetNTEOSA5420CardEntry1.3.6.1.4.1.2544.1.12.3.1.63.1not-accessibleA conceptual row in the ethernetNTEOSA5420CardTable.
PHY ethernetNTEOSA5420CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.63.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE OSA5420 Card.
ADM ethernetNTEOSA5420CardAdminState1.3.6.1.4.1.2544.1.12.3.1.63.1.2AdminStateread-writeAdministrative State of the Ethernet NTE OSA5420 Card.
OPE ethernetNTEOSA5420CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.63.1.3OperationalStateread-onlyOperational State of the Ethernet NTE OSA5420 Card.
SEC ethernetNTEOSA5420CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.63.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE OSA5420 Card.
I32 ethernetNTEOSA5420CardVoltage1.3.6.1.4.1.2544.1.12.3.1.63.1.5Integer32read-onlyVoltage of the Ethernet NTE OSA5420 Card.
I32 ethernetNTEOSA5420CardTemperature1.3.6.1.4.1.2544.1.12.3.1.63.1.6Integer32read-onlyTemperature of the Ethernet NTE OSA5420 Card.
T/F ethernetNTEOSA5420CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.63.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE OSA5420 Card.
RES ethernetNTEOSA5420CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.63.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE OSA5420 card.
NUM ethernetNTEOSA5420CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.63.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEOSA5421CardTable1.3.6.1.4.1.2544.1.12.3.1.64not-accessibleContains information on Ethernet NTE OSA5421 Card. These are supported on the FSP150CC OSA5421 product.
ethernetNTEOSA5421CardEntry1.3.6.1.4.1.2544.1.12.3.1.64.1not-accessibleA conceptual row in the ethernetNTEOSA5421CardTable.
PHY ethernetNTEOSA5421CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.64.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE OSA5421 Card.
ADM ethernetNTEOSA5421CardAdminState1.3.6.1.4.1.2544.1.12.3.1.64.1.2AdminStateread-writeAdministrative State of the Ethernet NTE OSA5421 Card.
OPE ethernetNTEOSA5421CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.64.1.3OperationalStateread-onlyOperational State of the Ethernet NTE OSA5421 Card.
SEC ethernetNTEOSA5421CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.64.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE OSA5421 Card.
I32 ethernetNTEOSA5421CardVoltage1.3.6.1.4.1.2544.1.12.3.1.64.1.5Integer32read-onlyVoltage of the Ethernet NTE OSA5421 Card.
I32 ethernetNTEOSA5421CardTemperature1.3.6.1.4.1.2544.1.12.3.1.64.1.6Integer32read-onlyTemperature of the Ethernet NTE OSA5421 Card.
T/F ethernetNTEOSA5421CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.64.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE OSA5421 Card.
RES ethernetNTEOSA5421CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.64.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE OSA5421 card.
NUM ethernetNTEOSA5421CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.64.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEGE114GCardTable1.3.6.1.4.1.2544.1.12.3.1.65not-accessibleContains information on Ethernet NTE GE114G Cards. These are supported on the FSP150CC GE114G product.
ethernetNTEGE114GCardEntry1.3.6.1.4.1.2544.1.12.3.1.65.1not-accessibleA conceptual row in the ethernetNTEGE114GCardTable.
PHY ethernetNTEGE114GCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.65.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114G Card.
ADM ethernetNTEGE114GCardAdminState1.3.6.1.4.1.2544.1.12.3.1.65.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114G Card.
OPE ethernetNTEGE114GCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.65.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114G Card.
SEC ethernetNTEGE114GCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.65.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114G Card.
I32 ethernetNTEGE114GCardVoltage1.3.6.1.4.1.2544.1.12.3.1.65.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114G Card.
I32 ethernetNTEGE114GCardTemperature1.3.6.1.4.1.2544.1.12.3.1.65.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114G Card.
T/F ethernetNTEGE114GCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.65.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114G Card.
RES ethernetNTEGE114GCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.65.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114G card.
NUM ethernetNTEGE114GCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.65.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114GCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.65.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114G card.
SWI ethernetNTEGE114GCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.65.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114G card.
bits16PortCardTable1.3.6.1.4.1.2544.1.12.3.1.66not-accessibleA list of entries corresponding to BITS 16 Port Expansion Card Facilities for configuration purposes.
bits16PortCardEntry1.3.6.1.4.1.2544.1.12.3.1.66.1not-accessibleA conceptual row in the bits16PortCardTable
PHY bits16PortCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.66.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this card
ADM bits16PortCardAdminState1.3.6.1.4.1.2544.1.12.3.1.66.1.2AdminStateread-writeThis object represents the Administrative State of the BITS 16 Port Expansion Card.
OPE bits16PortCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.66.1.3OperationalStateread-onlyThis object represents the Operational State of the BITS 16 Port Expansion Card.
SEC bits16PortCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.66.1.4SecondaryStateread-onlyThis object represents the Secondary State of the BITS 16 Port Expansion Card.
ROW bits16PortCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.66.1.5RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of bits16PortCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with bits16PortCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The bits16PortCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
STR bits16PortCardAlias1.3.6.1.4.1.2544.1.12.3.1.66.1.6DisplayStringread-writeThis object allows SNMP management entities to provide an alias to the BITS 16 Port Expansion Card.
I32 bits16PortCardTemperature1.3.6.1.4.1.2544.1.12.3.1.66.1.7Integer32read-onlyTemperature of the BITS 16 Port Expansion Card
ethernetNTEGE114ProVmHCardTable1.3.6.1.4.1.2544.1.12.3.1.67not-accessibleContains information on Ethernet NTE GE114 Pro VM-H Cards. These are supported on the FSP150CC GE114 Pro VM-H product.
ethernetNTEGE114ProVmHCardEntry1.3.6.1.4.1.2544.1.12.3.1.67.1not-accessibleA conceptual row in the ethernetNTEGE114ProVmHCardTable.
PHY ethernetNTEGE114ProVmHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.67.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114 Pro VM-H Card.
ADM ethernetNTEGE114ProVmHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.67.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114 Pro VM-H Card.
OPE ethernetNTEGE114ProVmHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.67.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114ProVmH Card.
SEC ethernetNTEGE114ProVmHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.67.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114ProVmH Card.
I32 ethernetNTEGE114ProVmHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.67.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114ProVmH Card.
I32 ethernetNTEGE114ProVmHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.67.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114ProVmH Card.
T/F ethernetNTEGE114ProVmHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.67.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114ProVmH Card.
RES ethernetNTEGE114ProVmHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.67.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114ProVmH card.
NUM ethernetNTEGE114ProVmHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.67.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114ProVmHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.67.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114ProVmH card.
SWI ethernetNTEGE114ProVmHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.67.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114ProVmH card.
ethernetNTEGE114ProVmCHCardTable1.3.6.1.4.1.2544.1.12.3.1.68not-accessibleContains information on Ethernet NTE GE114 Pro VM-CH Cards. These are supported on the FSP150CC GE114 Pro VM-CH product.
ethernetNTEGE114ProVmCHCardEntry1.3.6.1.4.1.2544.1.12.3.1.68.1not-accessibleA conceptual row in the ethernetNTEGE114ProVmCHCardTable.
PHY ethernetNTEGE114ProVmCHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.68.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114 Pro VM-CH Card.
ADM ethernetNTEGE114ProVmCHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.68.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114 Pro VM-CH Card.
OPE ethernetNTEGE114ProVmCHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.68.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114ProVmCH Card.
SEC ethernetNTEGE114ProVmCHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.68.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114ProVmCH Card.
I32 ethernetNTEGE114ProVmCHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.68.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114ProVmCH Card.
I32 ethernetNTEGE114ProVmCHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.68.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114ProVmCH Card.
T/F ethernetNTEGE114ProVmCHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.68.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114ProVmCH Card.
RES ethernetNTEGE114ProVmCHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.68.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114ProVmCH card.
NUM ethernetNTEGE114ProVmCHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.68.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114ProVmCHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.68.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114ProVmCH card.
SWI ethernetNTEGE114ProVmCHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.68.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114ProVmCH card.
ethernetNTEGE114ProVmCSHCardTable1.3.6.1.4.1.2544.1.12.3.1.69not-accessibleContains information on Ethernet NTE GE114 Pro VM-CSH Cards. These are supported on the FSP150CC GE114 Pro VM-CSH product.
ethernetNTEGE114ProVmCSHCardEntry1.3.6.1.4.1.2544.1.12.3.1.69.1not-accessibleA conceptual row in the ethernetNTEGE114ProVmCSHCardTable.
PHY ethernetNTEGE114ProVmCSHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.69.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114 Pro VM-CSH Card.
ADM ethernetNTEGE114ProVmCSHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.69.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114 Pro VM-CSH Card.
OPE ethernetNTEGE114ProVmCSHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.69.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114ProVmCSH Card.
SEC ethernetNTEGE114ProVmCSHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.69.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114ProVmCSH Card.
I32 ethernetNTEGE114ProVmCSHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.69.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114ProVmCSH Card.
I32 ethernetNTEGE114ProVmCSHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.69.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114ProVmCSH Card.
T/F ethernetNTEGE114ProVmCSHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.69.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114ProVmCSH Card.
RES ethernetNTEGE114ProVmCSHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.69.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114ProVmCSH card.
NUM ethernetNTEGE114ProVmCSHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.69.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114ProVmCSHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.69.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114ProVmCSH card.
SWI ethernetNTEGE114ProVmCSHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.69.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114ProVmCSH card.
serverCardTable1.3.6.1.4.1.2544.1.12.3.1.70not-accessibleContains information on ServerCard within the Shelf.
serverCardEntry1.3.6.1.4.1.2544.1.12.3.1.70.1not-accessibleA conceptual row in the serverCardTable.
PHY serverCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.70.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this Server Card.
ADM serverCardAdminState1.3.6.1.4.1.2544.1.12.3.1.70.1.2AdminStateread-writeAdministrative State of the Server Card.
OPE serverCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.70.1.3OperationalStateread-onlyOperational State of the Server Card.
SEC serverCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.70.1.4SecondaryStateread-onlySecondary State of the Server Card.
STO serverCardStorageType1.3.6.1.4.1.2544.1.12.3.1.70.1.5StorageTyperead-createStorage Type of the Server Card.
I32 serverCardVoltage1.3.6.1.4.1.2544.1.12.3.1.70.1.6Integer32read-onlyVoltage of the Server Card.
I32 serverCardTemperature1.3.6.1.4.1.2544.1.12.3.1.70.1.7Integer32read-onlyTemperature of the Server Card.
I32 serverCardUpTime1.3.6.1.4.1.2544.1.12.3.1.70.1.8Integer32read-onlyUp time of the Server Card.
I32 serverCardVmNumber1.3.6.1.4.1.2544.1.12.3.1.70.1.9Integer32read-onlyVM number of the Server Card.
I32 serverCardVirtualCpuTotal1.3.6.1.4.1.2544.1.12.3.1.70.1.10Integer32read-onlyTotal virtual CPU of the Server Card.
I32 serverCardVirtualCpuAvailiable1.3.6.1.4.1.2544.1.12.3.1.70.1.11Integer32read-onlyAvailiable virtual CPU of the Server Card.
I32 serverCardMemoryTotal1.3.6.1.4.1.2544.1.12.3.1.70.1.12Integer32read-onlyTotal memory of the Server Card.
I32 serverCardMemoryAvailiable1.3.6.1.4.1.2544.1.12.3.1.70.1.13Integer32read-onlyAvailiable memory of the Server Card.
I32 serverCardStorageTotal1.3.6.1.4.1.2544.1.12.3.1.70.1.14Integer32read-onlyTotal storage of the Server Card.
I32 serverCardStorageAvailiable1.3.6.1.4.1.2544.1.12.3.1.70.1.15Integer32read-onlyAvailiable storage of the Server Card.
STR serverCardHvVersion1.3.6.1.4.1.2544.1.12.3.1.70.1.16DisplayStringread-onlyHV version of the Server Card.
STR serverCardHostName1.3.6.1.4.1.2544.1.12.3.1.70.1.17DisplayStringread-createHostname of the Server Card.
RES serverCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.70.1.18RestartTyperead-writeAllows to perform specified action on the VM server card.
ROW serverCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.70.1.19RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of serverCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with serverCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The serverCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
T/F serverCardIgnoreWatchdog1.3.6.1.4.1.2544.1.12.3.1.70.1.20TruthValueread-writeIgnore keep-alive watchdog.
pps16PortCardTable1.3.6.1.4.1.2544.1.12.3.1.71not-accessibleA list of entries corresponding to BITS 16 Port Expansion Card Facilities for configuration purposes.
pps16PortCardEntry1.3.6.1.4.1.2544.1.12.3.1.71.1not-accessibleA conceptual row in the pps16PortCardTable
PHY pps16PortCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.71.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this card
ADM pps16PortCardAdminState1.3.6.1.4.1.2544.1.12.3.1.71.1.2AdminStateread-writeThis object represents the Administrative State of the BITS 16 Port Expansion Card.
OPE pps16PortCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.71.1.3OperationalStateread-onlyThis object represents the Operational State of the BITS 16 Port Expansion Card.
SEC pps16PortCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.71.1.4SecondaryStateread-onlyThis object represents the Secondary State of the BITS 16 Port Expansion Card.
ROW pps16PortCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.71.1.5RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of pps16PortCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with pps16PortCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The pps16PortCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
STR pps16PortCardAlias1.3.6.1.4.1.2544.1.12.3.1.71.1.6DisplayStringread-writeThis object allows SNMP management entities to provide an alias to the BITS 16 Port Expansion Card.
clk16PortCardTable1.3.6.1.4.1.2544.1.12.3.1.72not-accessibleA list of entries corresponding to BITS 16 Port Expansion Card Facilities for configuration purposes.
clk16PortCardEntry1.3.6.1.4.1.2544.1.12.3.1.72.1not-accessibleA conceptual row in the clk16PortCardTable
PHY clk16PortCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.72.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this card
ADM clk16PortCardAdminState1.3.6.1.4.1.2544.1.12.3.1.72.1.2AdminStateread-writeThis object represents the Administrative State of the BITS 16 Port Expansion Card.
OPE clk16PortCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.72.1.3OperationalStateread-onlyThis object represents the Operational State of the BITS 16 Port Expansion Card.
SEC clk16PortCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.72.1.4SecondaryStateread-onlyThis object represents the Secondary State of the BITS 16 Port Expansion Card.
ROW clk16PortCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.72.1.5RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of clk16PortCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with clk16PortCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The clk16PortCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
STR clk16PortCardAlias1.3.6.1.4.1.2544.1.12.3.1.72.1.6DisplayStringread-writeThis object allows SNMP management entities to provide an alias to the BITS 16 Port Expansion Card.
todPps16PortCardTable1.3.6.1.4.1.2544.1.12.3.1.73not-accessibleA list of entries corresponding to BITS 16 Port Expansion Card Facilities for configuration purposes.
todPps16PortCardEntry1.3.6.1.4.1.2544.1.12.3.1.73.1not-accessibleA conceptual row in the todPps16PortCardTable
PHY todPps16PortCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.73.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this card
ADM todPps16PortCardAdminState1.3.6.1.4.1.2544.1.12.3.1.73.1.2AdminStateread-writeThis object represents the Administrative State of the BITS 16 Port Expansion Card.
OPE todPps16PortCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.73.1.3OperationalStateread-onlyThis object represents the Operational State of the BITS 16 Port Expansion Card.
SEC todPps16PortCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.73.1.4SecondaryStateread-onlyThis object represents the Secondary State of the BITS 16 Port Expansion Card.
ROW todPps16PortCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.73.1.5RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of todPps16PortCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with todPps16PortCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The todPps16PortCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
STR todPps16PortCardAlias1.3.6.1.4.1.2544.1.12.3.1.73.1.6DisplayStringread-writeThis object allows SNMP management entities to provide an alias to the BITS 16 Port Expansion Card.
ethernetNTEGE101ProCardTable1.3.6.1.4.1.2544.1.12.3.1.74not-accessibleContains information on Ethernet NTE GE101 Pro Cards. These are supported on the FSP150CC GE101 Pro product.
ethernetNTEGE101ProCardEntry1.3.6.1.4.1.2544.1.12.3.1.74.1not-accessibleA conceptual row in the ethernetNTEGE101ProCardTable.
PHY ethernetNTEGE101ProCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.74.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE101 Pro Card.
ADM ethernetNTEGE101ProCardAdminState1.3.6.1.4.1.2544.1.12.3.1.74.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE101 Pro Card.
OPE ethernetNTEGE101ProCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.74.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE101Pro Card.
SEC ethernetNTEGE101ProCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.74.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE101Pro Card.
I32 ethernetNTEGE101ProCardVoltage1.3.6.1.4.1.2544.1.12.3.1.74.1.5Integer32read-onlyVoltage of the Ethernet NTE GE101Pro Card.
I32 ethernetNTEGE101ProCardTemperature1.3.6.1.4.1.2544.1.12.3.1.74.1.6Integer32read-onlyTemperature of the Ethernet NTE GE101Pro Card.
T/F ethernetNTEGE101ProCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.74.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE101Pro Card.
RES ethernetNTEGE101ProCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.74.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE101Pro card.
NUM ethernetNTEGE101ProCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.74.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE101ProCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.74.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE101Pro card.
SWI ethernetNTEGE101ProCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.74.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE101Pro card.
ethernetNTEGO102ProSCardTable1.3.6.1.4.1.2544.1.12.3.1.75not-accessibleContains information on Ethernet NTE Pro GO102Pro S Cards. These are supported on the FSP150CC GO102ProS product.
ethernetNTEGO102ProSCardEntry1.3.6.1.4.1.2544.1.12.3.1.75.1not-accessibleA conceptual row in the ethernetNTEGO102ProSCardTable.
PHY ethernetNTEGO102ProSCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.75.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GO102ProS Card.
ADM ethernetNTEGO102ProSCardAdminState1.3.6.1.4.1.2544.1.12.3.1.75.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GO102ProS Card.
OPE ethernetNTEGO102ProSCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.75.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GO102ProS Card.
SEC ethernetNTEGO102ProSCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.75.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GO102ProS Card.
I32 ethernetNTEGO102ProSCardVoltage1.3.6.1.4.1.2544.1.12.3.1.75.1.5Integer32read-onlyVoltage of the Ethernet NTE GO102ProS Card.
I32 ethernetNTEGO102ProSCardTemperature1.3.6.1.4.1.2544.1.12.3.1.75.1.6Integer32read-onlyTemperature of the Ethernet NTE GO102ProS Card.
T/F ethernetNTEGO102ProSCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.75.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GO102ProS Card.
RES ethernetNTEGO102ProSCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.75.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GO102ProS card.
NUM ethernetNTEGO102ProSCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.75.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGO102ProSCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.75.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GO102ProS card.
SWI ethernetNTEGO102ProSCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.75.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GO102ProS card.
ethernetNTEGO102ProSPCardTable1.3.6.1.4.1.2544.1.12.3.1.76not-accessibleContains information on Ethernet NTE Pro Rugged S Cards. These are supported on the FSP150CC GO102ProSP product.
ethernetNTEGO102ProSPCardEntry1.3.6.1.4.1.2544.1.12.3.1.76.1not-accessibleA conceptual row in the ethernetNTEGO102ProSPCardTable.
PHY ethernetNTEGO102ProSPCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.76.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GO102ProSP Card.
ADM ethernetNTEGO102ProSPCardAdminState1.3.6.1.4.1.2544.1.12.3.1.76.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GO102ProSP Card.
OPE ethernetNTEGO102ProSPCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.76.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GO102ProSP Card.
SEC ethernetNTEGO102ProSPCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.76.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GO102ProSP Card.
I32 ethernetNTEGO102ProSPCardVoltage1.3.6.1.4.1.2544.1.12.3.1.76.1.5Integer32read-onlyVoltage of the Ethernet NTE GO102ProSP Card.
I32 ethernetNTEGO102ProSPCardTemperature1.3.6.1.4.1.2544.1.12.3.1.76.1.6Integer32read-onlyTemperature of the Ethernet NTE GO102ProSP Card.
T/F ethernetNTEGO102ProSPCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.76.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GO102ProSP Card.
RES ethernetNTEGO102ProSPCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.76.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GO102ProSP card.
NUM ethernetNTEGO102ProSPCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.76.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGO102ProSPCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.76.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GO102ProSP card.
SWI ethernetNTEGO102ProSPCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.76.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GO102ProSP card.
ethernetNTECX101Pro30ACardTable1.3.6.1.4.1.2544.1.12.3.1.77not-accessibleContains information on Ethernet NTE Pro Rugged S Cards. These are supported on the FSP150CC GE101 Pro product.
ethernetNTECX101Pro30ACardEntry1.3.6.1.4.1.2544.1.12.3.1.77.1not-accessibleA conceptual row in the ethernetNTECX101Pro30ACardTable.
PHY ethernetNTECX101Pro30ACardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.77.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE CX101PRO 30A Card.
ADM ethernetNTECX101Pro30ACardAdminState1.3.6.1.4.1.2544.1.12.3.1.77.1.2AdminStateread-writeAdministrative State of the Ethernet NTE CX101PRO 30A Card.
OPE ethernetNTECX101Pro30ACardOperationalState1.3.6.1.4.1.2544.1.12.3.1.77.1.3OperationalStateread-onlyOperational State of the Ethernet NTE CX101Pro30A Card.
SEC ethernetNTECX101Pro30ACardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.77.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE CX101Pro30A Card.
I32 ethernetNTECX101Pro30ACardVoltage1.3.6.1.4.1.2544.1.12.3.1.77.1.5Integer32read-onlyVoltage of the Ethernet NTE CX101Pro30A Card.
I32 ethernetNTECX101Pro30ACardTemperature1.3.6.1.4.1.2544.1.12.3.1.77.1.6Integer32read-onlyTemperature of the Ethernet NTE CX101Pro30A Card.
T/F ethernetNTECX101Pro30ACardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.77.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE CX101Pro30A Card.
RES ethernetNTECX101Pro30ACardRestartAction1.3.6.1.4.1.2544.1.12.3.1.77.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE CX101Pro30A card.
NUM ethernetNTECX101Pro30ACardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.77.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTECX101Pro30ACardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.77.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE CX101Pro30A card.
SWI ethernetNTECX101Pro30ACardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.77.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE CX101Pro30A card.
ethernetNTECX102Pro30ACardTable1.3.6.1.4.1.2544.1.12.3.1.78not-accessibleContains information on Ethernet NTE Pro Rugged S Cards. These are supported on the FSP150CC GE101 Pro product.
ethernetNTECX102Pro30ACardEntry1.3.6.1.4.1.2544.1.12.3.1.78.1not-accessibleA conceptual row in the ethernetNTECX102Pro30ACardTable.
PHY ethernetNTECX102Pro30ACardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.78.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE101 Pro Card.
ADM ethernetNTECX102Pro30ACardAdminState1.3.6.1.4.1.2544.1.12.3.1.78.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE101 Pro Card.
OPE ethernetNTECX102Pro30ACardOperationalState1.3.6.1.4.1.2544.1.12.3.1.78.1.3OperationalStateread-onlyOperational State of the Ethernet NTE CX102Pro30A Card.
SEC ethernetNTECX102Pro30ACardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.78.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE CX102Pro30A Card.
I32 ethernetNTECX102Pro30ACardVoltage1.3.6.1.4.1.2544.1.12.3.1.78.1.5Integer32read-onlyVoltage of the Ethernet NTE CX102Pro30A Card.
I32 ethernetNTECX102Pro30ACardTemperature1.3.6.1.4.1.2544.1.12.3.1.78.1.6Integer32read-onlyTemperature of the Ethernet NTE CX102Pro30A Card.
T/F ethernetNTECX102Pro30ACardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.78.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE CX102Pro30A Card.
RES ethernetNTECX102Pro30ACardRestartAction1.3.6.1.4.1.2544.1.12.3.1.78.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE CX102Pro30A card.
NUM ethernetNTECX102Pro30ACardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.78.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTECX102Pro30ACardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.78.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE CX102Pro30A card.
SWI ethernetNTECX102Pro30ACardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.78.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE CX102Pro30A card.
ge4PortCardTable1.3.6.1.4.1.2544.1.12.3.1.79not-accessibleA list of entries corresponding to GE 4 Port Expansion Card Facilities for configuration purposes.
ge4PortCardEntry1.3.6.1.4.1.2544.1.12.3.1.79.1not-accessibleA conceptual row in the ge4PortCardTable
PHY ge4PortCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.79.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this card
ADM ge4PortCardAdminState1.3.6.1.4.1.2544.1.12.3.1.79.1.2AdminStateread-writeThis object represents the Administrative State of the GE 4 Port Expansion Card.
OPE ge4PortCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.79.1.3OperationalStateread-onlyThis object represents the Operational State of the GE 4 Port Expansion Card.
SEC ge4PortCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.79.1.4SecondaryStateread-onlyThis object represents the Secondary State of the GE 4 Port Expansion Card.
ROW ge4PortCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.79.1.5RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of ge4PortCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with ge4PortCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The ge4PortCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
STR ge4PortCardAlias1.3.6.1.4.1.2544.1.12.3.1.79.1.6DisplayStringread-writeThis object allows SNMP management entities to provide an alias to the GE 4 Port Expansion Card.
I32 ge4PortCardTemperature1.3.6.1.4.1.2544.1.12.3.1.79.1.7Integer32read-onlyTemperature of the GE 4 Port Expansion Card.
ethernetNTEXG116PROCardTable1.3.6.1.4.1.2544.1.12.3.1.80not-accessibleContains information on Ethernet NTE XG116PRO Card. These are supported on the FSP150CC XG116PRO product.
ethernetNTEXG116PROCardEntry1.3.6.1.4.1.2544.1.12.3.1.80.1not-accessibleA conceptual row in the ethernetNTEXG116PROCardTable.
PHY ethernetNTEXG116PROCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.80.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE XG116PRO Card.
ADM ethernetNTEXG116PROCardAdminState1.3.6.1.4.1.2544.1.12.3.1.80.1.2AdminStateread-writeAdministrative State of the Ethernet NTE XG116PRO Card.
OPE ethernetNTEXG116PROCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.80.1.3OperationalStateread-onlyOperational State of the Ethernet NTE XG116PRO Card.
SEC ethernetNTEXG116PROCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.80.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE XG116PRO Card.
I32 ethernetNTEXG116PROCardVoltage1.3.6.1.4.1.2544.1.12.3.1.80.1.5Integer32read-onlyVoltage of the Ethernet NTE XG116PRO Card.
I32 ethernetNTEXG116PROCardTemperature1.3.6.1.4.1.2544.1.12.3.1.80.1.6Integer32read-onlyTemperature of the Ethernet NTE XG116PRO Card.
T/F ethernetNTEXG116PROCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.80.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE XG116PRO Card.
RES ethernetNTEXG116PROCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.80.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE XG116PRO card.
NUM ethernetNTEXG116PROCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.80.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEXG120PROCardTable1.3.6.1.4.1.2544.1.12.3.1.81not-accessibleContains information on Ethernet NTE XG120PRO Card. These are supported on the FSP150CC XG120PRO product.
ethernetNTEXG120PROCardEntry1.3.6.1.4.1.2544.1.12.3.1.81.1not-accessibleA conceptual row in the ethernetNTEXG120PROCardTable.
PHY ethernetNTEXG120PROCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.81.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE XG120PRO Card.
ADM ethernetNTEXG120PROCardAdminState1.3.6.1.4.1.2544.1.12.3.1.81.1.2AdminStateread-writeAdministrative State of the Ethernet NTE XG120PRO Card.
OPE ethernetNTEXG120PROCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.81.1.3OperationalStateread-onlyOperational State of the Ethernet NTE XG120PRO Card.
SEC ethernetNTEXG120PROCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.81.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE XG120PRO Card.
I32 ethernetNTEXG120PROCardVoltage1.3.6.1.4.1.2544.1.12.3.1.81.1.5Integer32read-onlyVoltage of the Ethernet NTE XG120PRO Card.
I32 ethernetNTEXG120PROCardTemperature1.3.6.1.4.1.2544.1.12.3.1.81.1.6Integer32read-onlyTemperature of the Ethernet NTE XG120PRO Card.
T/F ethernetNTEXG120PROCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.81.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE XG120PRO Card.
RES ethernetNTEXG120PROCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.81.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE XG120PRO card.
NUM ethernetNTEXG120PROCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.81.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEGE112ProVmCardTable1.3.6.1.4.1.2544.1.12.3.1.82not-accessibleContains information on Ethernet NTE GE112 Pro VM Cards. These are supported on the FSP150CC GE112 Pro VM product.
ethernetNTEGE112ProVmCardEntry1.3.6.1.4.1.2544.1.12.3.1.82.1not-accessibleA conceptual row in the ethernetNTEGE112ProVmCardTable.
PHY ethernetNTEGE112ProVmCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.82.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114 Pro VM-CSH Card.
ADM ethernetNTEGE112ProVmCardAdminState1.3.6.1.4.1.2544.1.12.3.1.82.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114 Pro VM-CSH Card.
OPE ethernetNTEGE112ProVmCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.82.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE112ProVm Card.
SEC ethernetNTEGE112ProVmCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.82.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE112ProVm Card.
I32 ethernetNTEGE112ProVmCardVoltage1.3.6.1.4.1.2544.1.12.3.1.82.1.5Integer32read-onlyVoltage of the Ethernet NTE GE112ProVm Card.
I32 ethernetNTEGE112ProVmCardTemperature1.3.6.1.4.1.2544.1.12.3.1.82.1.6Integer32read-onlyTemperature of the Ethernet NTE GE112ProVm Card.
T/F ethernetNTEGE112ProVmCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.82.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE112ProVm Card.
RES ethernetNTEGE112ProVmCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.82.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE112ProVm card.
NUM ethernetNTEGE112ProVmCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.82.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE112ProVmCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.82.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE112ProVm card.
SWI ethernetNTEGE112ProVmCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.82.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE112ProVm card.
ethernetNTEOSA5401CardTable1.3.6.1.4.1.2544.1.12.3.1.83not-accessibleContains information on Ethernet NTE OSA5401 Card. These are supported on the OSA5401 product.
ethernetNTEOSA5401CardEntry1.3.6.1.4.1.2544.1.12.3.1.83.1not-accessibleA conceptual row in the ethernetNTEOSA5401CardTable.
PHY ethernetNTEOSA5401CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.83.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE OSA5401 Card.
ADM ethernetNTEOSA5401CardAdminState1.3.6.1.4.1.2544.1.12.3.1.83.1.2AdminStateread-writeAdministrative State of the Ethernet NTE OSA5401 Card.
OPE ethernetNTEOSA5401CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.83.1.3OperationalStateread-onlyOperational State of the Ethernet NTE OSA5401 Card.
RES ethernetNTEOSA5401CardTableRestartAction1.3.6.1.4.1.2544.1.12.3.1.83.1.4RestartTyperead-writeAllows to perform restart action on NTE OSA5401 Card.
ethernetNTEOSA5405CardTable1.3.6.1.4.1.2544.1.12.3.1.84not-accessibleContains information on Ethernet NTE OSA5405 Card. These are supported on the OSA5405 product.
ethernetNTEOSA5405CardEntry1.3.6.1.4.1.2544.1.12.3.1.84.1not-accessibleA conceptual row in the ethernetNTEOSA5405CardTable.
PHY ethernetNTEOSA5405CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.84.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE OSA5405 Card.
ADM ethernetNTEOSA5405CardAdminState1.3.6.1.4.1.2544.1.12.3.1.84.1.2AdminStateread-writeAdministrative State of the Ethernet NTE OSA5405 Card.
OPE ethernetNTEOSA5405CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.84.1.3OperationalStateread-onlyOperational State of the Ethernet NTE OSA5405 Card.
I32 ethernetNTEOSA5405CardVoltage1.3.6.1.4.1.2544.1.12.3.1.84.1.4Integer32read-onlyVoltage of the Ethernet NTE OSA5405 Card in mV units.
I32 ethernetNTEOSA5405CardTemperature1.3.6.1.4.1.2544.1.12.3.1.84.1.5Integer32read-onlyTemperature of the Ethernet NTE OSA5405 Card.
RES ethernetNTEOSA5405CardTableRestartAction1.3.6.1.4.1.2544.1.12.3.1.84.1.6RestartTyperead-writeAllows to perform restart action on NTE OSA5405 Card.
ethernetCSMCardTable1.3.6.1.4.1.2544.1.12.3.1.85not-accessibleContains information on Ethernet CSM Card. These are supported on the OSA5430 and OSA5440 product.
ethernetCSMCardEntry1.3.6.1.4.1.2544.1.12.3.1.85.1not-accessibleA conceptual row in the ethernetCSMCardTable.
PHY ethernetCSMCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.85.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE CSM Card.
ADM ethernetCSMCardAdminState1.3.6.1.4.1.2544.1.12.3.1.85.1.2AdminStateread-writeAdministrative State of the Ethernet NTE CSM Card.
OPE ethernetCSMCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.85.1.3OperationalStateread-onlyOperational State of the Ethernet NTE CSM Card.
SEC ethernetCSMCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.85.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE CSM Card.
I32 ethernetCSMCardVoltage1.3.6.1.4.1.2544.1.12.3.1.85.1.5Integer32read-onlyVoltage of the Ethernet NTE CSM Card.
I32 ethernetCSMCardTemperature1.3.6.1.4.1.2544.1.12.3.1.85.1.6Integer32read-onlyTemperature of the Ethernet NTE CSM Card.
T/F ethernetCSMCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.85.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE CSM Card.
RES ethernetCSMCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.85.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE CSM card.
NUM ethernetCSMCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.85.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
STR ethernetCSMCardOscillatorType1.3.6.1.4.1.2544.1.12.3.1.85.1.10DisplayStringread-onlyThe mOscillatorType.
auxPortCardTable1.3.6.1.4.1.2544.1.12.3.1.87not-accessibleA list of entries corresponding to Auxiliary Port Expansion Card Facilities for configuration purposes.
auxPortCardEntry1.3.6.1.4.1.2544.1.12.3.1.87.1not-accessibleA conceptual row in the auxPortCardTable
PHY auxPortCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.87.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this card
ADM auxPortCardAdminState1.3.6.1.4.1.2544.1.12.3.1.87.1.2AdminStateread-writeThis object represents the Administrative State of the Auxiliary Port Expansion Card.
OPE auxPortCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.87.1.3OperationalStateread-onlyThis object represents the Operational State of the Auxiliary Port Expansion Card.
SEC auxPortCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.87.1.4SecondaryStateread-onlyThis object represents the Secondary State of the Auxiliary Port Expansion Card.
ROW auxPortCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.87.1.5RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of auxPortCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with auxPortCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The auxPortCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
STR auxPortCardAlias1.3.6.1.4.1.2544.1.12.3.1.87.1.6DisplayStringread-writeThis object allows SNMP management entities to provide an alias to the Auxiliary Port Expansion Card.
I32 auxPortCardTemperature1.3.6.1.4.1.2544.1.12.3.1.87.1.7Integer32read-onlyTemperature of the Auxiliary Port Expansion Card.
ethernetNTEGE102ProHCardTable1.3.6.1.4.1.2544.1.12.3.1.88not-accessibleContains information on Ethernet NTE GE102 Pro H Cards. These are supported on the FSP150CC GE102 Pro H product.
ethernetNTEGE102ProHCardEntry1.3.6.1.4.1.2544.1.12.3.1.88.1not-accessibleA conceptual row in the ethernetNTEGE102ProHCardTable.
PHY ethernetNTEGE102ProHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.88.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE102 Pro H Card.
ADM ethernetNTEGE102ProHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.88.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE102 Pro H Card.
OPE ethernetNTEGE102ProHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.88.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE102 Pro H Card.
SEC ethernetNTEGE102ProHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.88.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE102 Pro H Card.
I32 ethernetNTEGE102ProHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.88.1.5Integer32read-onlyVoltage of the Ethernet NTE GE102 Pro H Card.
I32 ethernetNTEGE102ProHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.88.1.6Integer32read-onlyTemperature of the Ethernet NTE GE102 Pro H Card.
T/F ethernetNTEGE102ProHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.88.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE102 Pro H Card.
RES ethernetNTEGE102ProHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.88.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE102 Pro H card.
NUM ethernetNTEGE102ProHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.88.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE102ProHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.88.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE102 Pro H card.
SWI ethernetNTEGE102ProHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.88.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE102 Pro H card.
OPE ethernetNTEGE102ProHCardPSU1State1.3.6.1.4.1.2544.1.12.3.1.88.1.12OperationalStateread-onlyOperational State of Power Supply Unit 1 on Ethernet NTE GE102Pro H card.
OPE ethernetNTEGE102ProHCardPSU2State1.3.6.1.4.1.2544.1.12.3.1.88.1.13OperationalStateread-onlyOperational State of Power Supply Unit 2 on Ethernet NTE GE102Pro H card.
OPE ethernetNTEGE102ProHCardFAN1State1.3.6.1.4.1.2544.1.12.3.1.88.1.14OperationalStateread-onlyOperational State of FAN 1 on Ethernet NTE GE102Pro H card.
OPE ethernetNTEGE102ProHCardFAN2State1.3.6.1.4.1.2544.1.12.3.1.88.1.15OperationalStateread-onlyOperational State of FAN 2 on Ethernet NTE GE102Pro H card.
PSU ethernetNTEGE102ProHCardPsuType1.3.6.1.4.1.2544.1.12.3.1.88.1.16PsuTyperead-onlyPSU Type on Ethernet NTE GE102Pro H card.
ethernetNTEGE102ProEFMHCardTable1.3.6.1.4.1.2544.1.12.3.1.89not-accessibleContains information on Ethernet NTE GE102 Pro EFMH Cards. These are supported on the FSP150CC GE102 Pro EFMH product.
ethernetNTEGE102ProEFMHCardEntry1.3.6.1.4.1.2544.1.12.3.1.89.1not-accessibleA conceptual row in the ethernetNTEGE102ProEFMHCardTable.
PHY ethernetNTEGE102ProEFMHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.89.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE102 Pro EFMH Card.
ADM ethernetNTEGE102ProEFMHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.89.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE102 Pro EFMH Card.
OPE ethernetNTEGE102ProEFMHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.89.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE102 Pro EFMH Card.
SEC ethernetNTEGE102ProEFMHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.89.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE102 Pro EFMHCard.
I32 ethernetNTEGE102ProEFMHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.89.1.5Integer32read-onlyVoltage of the Ethernet NTE GE102 Pro EFMH Card.
I32 ethernetNTEGE102ProEFMHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.89.1.6Integer32read-onlyTemperature of the Ethernet NTE GE102 Pro EFMH Card.
RES ethernetNTEGE102ProEFMHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.89.1.7RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE102Pro EFMH card.
OPE ethernetNTEGE102ProEFMHCardPSU1State1.3.6.1.4.1.2544.1.12.3.1.89.1.8OperationalStateread-onlyOperational State of Power Supply Unit 1 on Ethernet NTE GE102Pro EFMH card.
OPE ethernetNTEGE102ProEFMHCardPSU2State1.3.6.1.4.1.2544.1.12.3.1.89.1.9OperationalStateread-onlyOperational State of Power Supply Unit 2 on Ethernet NTE GE102Pro EFMH card.
OPE ethernetNTEGE102ProEFMHCardFAN1State1.3.6.1.4.1.2544.1.12.3.1.89.1.10OperationalStateread-onlyOperational State of FAN 1 on Ethernet NTE GE102Pro EFMH card.
OPE ethernetNTEGE102ProEFMHCardFAN2State1.3.6.1.4.1.2544.1.12.3.1.89.1.11OperationalStateread-onlyOperational State of FAN 2 on Ethernet NTE GE102Pro EFMH card.
PSU ethernetNTEGE102ProEFMHCardPsuType1.3.6.1.4.1.2544.1.12.3.1.89.1.12PsuTyperead-onlyPSU Type on Ethernet NTE GE102Pro EFMH card.
CMC ethernetNTEGE102ProEFMHCardLLFMode1.3.6.1.4.1.2544.1.12.3.1.89.1.13CmCPMRLinkLossFwdModeread-onlyCurrent Link Loss Forwarding Mode on CPMR.
CMC ethernetNTEGE102ProEFMHCardLLFModeAction1.3.6.1.4.1.2544.1.12.3.1.89.1.14CmCPMRLinkLossFwdModeread-writeOperation to set the appropriate mode on CPMR.
ethernetOsa3350MgntCardTable1.3.6.1.4.1.2544.1.12.3.1.90not-accessibleContains information on Ethernet Osa3350 Mgnt Cards.
ethernetOsa3350MgntCardEntry1.3.6.1.4.1.2544.1.12.3.1.90.1not-accessibleA conceptual row in the ethernetOsa3350MgntCardTable.
PHY ethernetOsa3350MgntCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.90.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet Osa3350 Mgnt Card.
ADM ethernetOsa3350MgntCardAdminState1.3.6.1.4.1.2544.1.12.3.1.90.1.2AdminStateread-writeAdministrative State of the Ethernet Osa3350 Mgnt Card.
OPE ethernetOsa3350MgntCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.90.1.3OperationalStateread-onlyOperational State of the Ethernet Osa3350 Mgnt Card.
SEC ethernetOsa3350MgntCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.90.1.4SecondaryStateread-onlySecondary State of the Ethernet Osa3350 Mgnt Card.
RES ethernetOsa3350MgntCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.90.1.5RestartTyperead-writeAllows to perform specified restart action on the Ethernet Osa3350 Mgnt card.
RES ethernetOsa3350MgntCardResyncAction1.3.6.1.4.1.2544.1.12.3.1.90.1.6ResyncTyperead-writeAllows to perform specified resync action on the Ethernet Osa3350 Mgnt card.
ethernetNTEXG116PROHCardTable1.3.6.1.4.1.2544.1.12.3.1.91not-accessibleContains information on Ethernet NTE XG116PRO (H) Card. These are supported on the FSP150CC XG116PRO (H) product.
ethernetNTEXG116PROHCardEntry1.3.6.1.4.1.2544.1.12.3.1.91.1not-accessibleA conceptual row in the ethernetNTEXG116PROHCardTable.
PHY ethernetNTEXG116PROHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.91.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE XG116PRO (H) Card.
ADM ethernetNTEXG116PROHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.91.1.2AdminStateread-writeAdministrative State of the Ethernet NTE XG116PRO (H) Card.
OPE ethernetNTEXG116PROHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.91.1.3OperationalStateread-onlyOperational State of the Ethernet NTE XG116PRO (H) Card.
SEC ethernetNTEXG116PROHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.91.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE XG116PRO (H) Card.
I32 ethernetNTEXG116PROHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.91.1.5Integer32read-onlyVoltage of the Ethernet NTE XG116PRO (H) Card.
I32 ethernetNTEXG116PROHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.91.1.6Integer32read-onlyTemperature of the Ethernet NTE XG116PRO (H) Card.
T/F ethernetNTEXG116PROHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.91.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE XG116PRO (H) Card.
RES ethernetNTEXG116PROHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.91.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE XG116PRO (H) card.
NUM ethernetNTEXG116PROHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.91.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEGO102ProSMCardTable1.3.6.1.4.1.2544.1.12.3.1.92not-accessibleContains information on Ethernet NTE Pro GO102Pro-S Mini Cards. These are supported on the FSP150CC GO102Pro-S Mini product.
ethernetNTEGO102ProSMCardEntry1.3.6.1.4.1.2544.1.12.3.1.92.1not-accessibleA conceptual row in the ethernetNTEGO102ProSMCardTable.
PHY ethernetNTEGO102ProSMCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.92.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GO102Pro-SM Card.
ADM ethernetNTEGO102ProSMCardAdminState1.3.6.1.4.1.2544.1.12.3.1.92.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GO102Pro-SM Card.
OPE ethernetNTEGO102ProSMCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.92.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GO102Pro-SM Card.
SEC ethernetNTEGO102ProSMCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.92.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GO102Pro-SM Card.
I32 ethernetNTEGO102ProSMCardVoltage1.3.6.1.4.1.2544.1.12.3.1.92.1.5Integer32read-onlyVoltage of the Ethernet NTE GO102Pro-SM Card.
I32 ethernetNTEGO102ProSMCardTemperature1.3.6.1.4.1.2544.1.12.3.1.92.1.6Integer32read-onlyTemperature of the Ethernet NTE GO102Pro-SM Card.
T/F ethernetNTEGO102ProSMCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.92.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GO102Pro-SM Card.
RES ethernetNTEGO102ProSMCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.92.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GO102Pro-SM card.
NUM ethernetNTEGO102ProSMCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.92.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGO102ProSMCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.92.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GO102Pro-SM card.
SWI ethernetNTEGO102ProSMCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.92.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GO102Pro-SM card.
ethernetNTEXG118PROSHCardTable1.3.6.1.4.1.2544.1.12.3.1.93not-accessibleContains information on Ethernet NTE XG118PRO (SH) Card. These are supported on the FSP150CC XG118PRO (SH) product.
ethernetNTEXG118PROSHCardEntry1.3.6.1.4.1.2544.1.12.3.1.93.1not-accessibleA conceptual row in the ethernetNTEXG118PROSHCardTable.
PHY ethernetNTEXG118PROSHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.93.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE XG118PRO (SH) Card.
ADM ethernetNTEXG118PROSHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.93.1.2AdminStateread-writeAdministrative State of the Ethernet NTE XG118PRO (SH) Card.
OPE ethernetNTEXG118PROSHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.93.1.3OperationalStateread-onlyOperational State of the Ethernet NTE XG118PRO (SH) Card.
SEC ethernetNTEXG118PROSHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.93.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE XG118PRO (SH) Card.
I32 ethernetNTEXG118PROSHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.93.1.5Integer32read-onlyVoltage of the Ethernet NTE XG118PRO (SH) Card.
I32 ethernetNTEXG118PROSHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.93.1.6Integer32read-onlyTemperature of the Ethernet NTE XG118PRO (SH) Card.
T/F ethernetNTEXG118PROSHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.93.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE XG118PRO (SH) Card.
RES ethernetNTEXG118PROSHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.93.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE XG118PRO (SH) card.
NUM ethernetNTEXG118PROSHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.93.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEXG118PROACSHCardTable1.3.6.1.4.1.2544.1.12.3.1.94not-accessibleContains information on Ethernet NTE XG118PROAC (SH) Card. These are supported on the FSP150CC XG118PROAC (SH) product.
ethernetNTEXG118PROACSHCardEntry1.3.6.1.4.1.2544.1.12.3.1.94.1not-accessibleA conceptual row in the ethernetNTEXG118PROACSHCardTable.
PHY ethernetNTEXG118PROACSHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.94.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE XG118PROAC (SH) Card.
ADM ethernetNTEXG118PROACSHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.94.1.2AdminStateread-writeAdministrative State of the Ethernet NTE XG118PROAC (SH) Card.
OPE ethernetNTEXG118PROACSHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.94.1.3OperationalStateread-onlyOperational State of the Ethernet NTE XG118PROAC (SH) Card.
SEC ethernetNTEXG118PROACSHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.94.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE XG118PROAC (SH) Card.
I32 ethernetNTEXG118PROACSHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.94.1.5Integer32read-onlyVoltage of the Ethernet NTE XG118PROAC (SH) Card.
I32 ethernetNTEXG118PROACSHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.94.1.6Integer32read-onlyTemperature of the Ethernet NTE XG118PROAC (SH) Card.
T/F ethernetNTEXG118PROACSHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.94.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE XG118PROAC (SH) Card.
RES ethernetNTEXG118PROACSHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.94.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE XG118PROAC (SH) card.
NUM ethernetNTEXG118PROACSHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.94.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
ethernetNTEGE114ProVmSHCardTable1.3.6.1.4.1.2544.1.12.3.1.95not-accessibleContains information on Ethernet NTE GE114 Pro VM-CH Cards. These are supported on the FSP150CC GE114 Pro VM-CH product.
ethernetNTEGE114ProVmSHCardEntry1.3.6.1.4.1.2544.1.12.3.1.95.1not-accessibleA conceptual row in the ethernetNTEGE114ProVmSHCardTable.
PHY ethernetNTEGE114ProVmSHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.95.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE114 Pro VM-CH Card.
ADM ethernetNTEGE114ProVmSHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.95.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE114 Pro VM-CH Card.
OPE ethernetNTEGE114ProVmSHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.95.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE114ProVmSH Card.
SEC ethernetNTEGE114ProVmSHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.95.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE114ProVmSH Card.
I32 ethernetNTEGE114ProVmSHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.95.1.5Integer32read-onlyVoltage of the Ethernet NTE GE114ProVmSH Card.
I32 ethernetNTEGE114ProVmSHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.95.1.6Integer32read-onlyTemperature of the Ethernet NTE GE114ProVmSH Card.
T/F ethernetNTEGE114ProVmSHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.95.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE114ProVmSH Card.
RES ethernetNTEGE114ProVmSHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.95.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE114ProVmSH card.
NUM ethernetNTEGE114ProVmSHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.95.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE114ProVmSHCardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.95.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE114ProVmSH card.
SWI ethernetNTEGE114ProVmSHCardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.95.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE114ProVmSH card.
ethernetNTEGE104CardTable1.3.6.1.4.1.2544.1.12.3.1.96not-accessibleContains information on Ethernet NTE GE104 Cards. These are supported on the FSP150CC GE104 product.
ethernetNTEGE104CardEntry1.3.6.1.4.1.2544.1.12.3.1.96.1not-accessibleA conceptual row in the ethernetNTEGE104CardTable.
PHY ethernetNTEGE104CardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.96.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE GE104 Card.
ADM ethernetNTEGE104CardAdminState1.3.6.1.4.1.2544.1.12.3.1.96.1.2AdminStateread-writeAdministrative State of the Ethernet NTE GE104 Card.
OPE ethernetNTEGE104CardOperationalState1.3.6.1.4.1.2544.1.12.3.1.96.1.3OperationalStateread-onlyOperational State of the Ethernet NTE GE104 Card.
SEC ethernetNTEGE104CardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.96.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE GE104 Card.
I32 ethernetNTEGE104CardVoltage1.3.6.1.4.1.2544.1.12.3.1.96.1.5Integer32read-onlyVoltage of the Ethernet NTE GE102 Card.
I32 ethernetNTEGE104CardTemperature1.3.6.1.4.1.2544.1.12.3.1.96.1.6Integer32read-onlyTemperature of the Ethernet NTE GE104 Card.
T/F ethernetNTEGE104CardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.96.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE GE104 Card.
RES ethernetNTEGE104CardRestartAction1.3.6.1.4.1.2544.1.12.3.1.96.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE GE104 card.
NUM ethernetNTEGE104CardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.96.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
NUM ethernetNTEGE104CardSwitchPortActionPort1.3.6.1.4.1.2544.1.12.3.1.96.1.10VariablePointerread-createWhich port to perform specified switch action on the Ethernet NTE GE104 card.
SWI ethernetNTEGE104CardSwitchPortAction1.3.6.1.4.1.2544.1.12.3.1.96.1.11SwitchPortActionread-writeAllows to perform specified action on the Ethernet NTE GE104 card.
ethernetNTEXG120PROSHCardTable1.3.6.1.4.1.2544.1.12.3.1.97not-accessibleContains information on Ethernet NTE XG120PROSH Card. These are supported on the FSP150CC XG120PROSH product.
ethernetNTEXG120PROSHCardEntry1.3.6.1.4.1.2544.1.12.3.1.97.1not-accessibleA conceptual row in the ethernetNTEXG120PROSHCardTable.
PHY ethernetNTEXG120PROSHCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.97.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for the Ethernet NTE XG120PROSH Card.
ADM ethernetNTEXG120PROSHCardAdminState1.3.6.1.4.1.2544.1.12.3.1.97.1.2AdminStateread-writeAdministrative State of the Ethernet NTE XG120PROSH Card.
OPE ethernetNTEXG120PROSHCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.97.1.3OperationalStateread-onlyOperational State of the Ethernet NTE XG120PROSH Card.
SEC ethernetNTEXG120PROSHCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.97.1.4SecondaryStateread-onlySecondary State of the Ethernet NTE XG120PROSH Card.
I32 ethernetNTEXG120PROSHCardVoltage1.3.6.1.4.1.2544.1.12.3.1.97.1.5Integer32read-onlyVoltage of the Ethernet NTE XG120PROSH Card.
I32 ethernetNTEXG120PROSHCardTemperature1.3.6.1.4.1.2544.1.12.3.1.97.1.6Integer32read-onlyTemperature of the Ethernet NTE XG120PROSH Card.
T/F ethernetNTEXG120PROSHCardSnmpDyingGaspEnabled1.3.6.1.4.1.2544.1.12.3.1.97.1.7TruthValueread-writeWhether or not SNMP dying gasp is enabled on the Ethernet NTE XG120PROSH Card.
RES ethernetNTEXG120PROSHCardRestartAction1.3.6.1.4.1.2544.1.12.3.1.97.1.8RestartTyperead-writeAllows to perform specified action on the Ethernet NTE XG120PROSH card.
NUM ethernetNTEXG120PROSHCardFineGrainedPmInterval1.3.6.1.4.1.2544.1.12.3.1.97.1.9CmPmIntervalTyperead-writeAllows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
mbGnssCardTable1.3.6.1.4.1.2544.1.12.3.1.98not-accessibleA list of entries corresponding to MB GNSS Expansion Card Facilities for configuration purposes.
mbGnssCardEntry1.3.6.1.4.1.2544.1.12.3.1.98.1not-accessibleA conceptual row in the mbGnssCardTable
PHY mbGnssCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.98.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this card
ADM mbGnssCardAdminState1.3.6.1.4.1.2544.1.12.3.1.98.1.2AdminStateread-writeThis object represents the Administrative State of the BITS 16 Port Expansion Card.
OPE mbGnssCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.98.1.3OperationalStateread-onlyThis object represents the Operational State of the BITS 16 Port Expansion Card.
SEC mbGnssCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.98.1.4SecondaryStateread-onlyThis object represents the Secondary State of the BITS 16 Port Expansion Card.
ROW mbGnssCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.98.1.5RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of mbGnssCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with mbGnssCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The mbGnssCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
STR mbGnssCardAlias1.3.6.1.4.1.2544.1.12.3.1.98.1.6DisplayStringread-writeThis object allows SNMP management entities to provide an alias to the MB GNSS Expansion Card.
f3IrigCardTable1.3.6.1.4.1.2544.1.12.3.1.99not-accessibleA list of entries corresponding to IRIG Card Facilities for configuration purposes.
f3IrigCardEntry1.3.6.1.4.1.2544.1.12.3.1.99.1not-accessibleA conceptual row in the f3IrigCardTable
PHY f3IrigCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.99.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this card
STR f3IrigCardAlias1.3.6.1.4.1.2544.1.12.3.1.99.1.2DisplayStringread-writeThis object allows SNMP management entities to provide an alias to the GE 4 Port Expansion Card.
ADM f3IrigCardAdminState1.3.6.1.4.1.2544.1.12.3.1.99.1.3AdminStateread-writeThis object represents the Administrative State of the GE 4 Port Expansion Card.
OPE f3IrigCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.99.1.4OperationalStateread-onlyThis object represents the Operational State of the GE 4 Port Expansion Card.
SEC f3IrigCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.99.1.5SecondaryStateread-onlyThis object represents the Secondary State of the GE 4 Port Expansion Card.
I32 f3IrigCardTemperature1.3.6.1.4.1.2544.1.12.3.1.99.1.6Integer32read-onlyTemperature of the GE 4 Port Expansion Card.
STO f3IrigCardStorageType1.3.6.1.4.1.2544.1.12.3.1.99.1.7StorageTyperead-createStorage Type of the IRIG Card.
ROW f3IrigCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.99.1.8RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of f3IrigCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with f3IrigCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The f3IrigCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
compositeClockCardTable1.3.6.1.4.1.2544.1.12.3.1.100not-accessibleA list of entries corresponding to Composite Clock Expansion Card Facilities for configuration purposes.
compositeClockCardEntry1.3.6.1.4.1.2544.1.12.3.1.100.1not-accessibleA conceptual row in the compositeClockCardTable
PHY compositeClockCardEntityIndex1.3.6.1.4.1.2544.1.12.3.1.100.1.1PhysicalIndexread-onlyEntity Index from ENTITY-MIB for this card
ADM compositeClockCardAdminState1.3.6.1.4.1.2544.1.12.3.1.100.1.2AdminStateread-writeThis object represents the Administrative State of the BITS 16 Port Expansion Card.
OPE compositeClockCardOperationalState1.3.6.1.4.1.2544.1.12.3.1.100.1.3OperationalStateread-onlyThis object represents the Operational State of the BITS 16 Port Expansion Card.
SEC compositeClockCardSecondaryState1.3.6.1.4.1.2544.1.12.3.1.100.1.4SecondaryStateread-onlyThis object represents the Secondary State of the BITS 16 Port Expansion Card.
ROW compositeClockCardRowStatus1.3.6.1.4.1.2544.1.12.3.1.100.1.5RowStatusread-createThe status of this row. An entry MUST NOT exist in the active state unless all objects in the entry have an appropriate value, as described in the description clause for each writable object. The values of compositeClockCardRowStatus supported are createAndGo(4) and destroy(6). All mandatory attributes must be specified in a single SNMP SET request with compositeClockCardRowStatus value as createAndGo(4). Upon successful row creation, this object has a value of active(1). The compositeClockCardRowStatus object may be modified if the associated instance of this object is equal to active(1).
STR compositeClockCardAlias1.3.6.1.4.1.2544.1.12.3.1.100.1.6DisplayStringread-writeThis object allows SNMP management entities to provide an alias to the COMPOSITE CLOCK Expansion Card.
f3StorageDeviceTable1.3.6.1.4.1.2544.1.12.3.1.101not-accessibleContains information on storage devices within the server card.
f3StorageDeviceEntry1.3.6.1.4.1.2544.1.12.3.1.101.1not-accessibleA conceptual row in the f3StorageDeviceTable.
T/F f3StorageDeviceInternalSsdHealth1.3.6.1.4.1.2544.1.12.3.1.101.1.1TruthValueread-onlyIndicates health of internal SSD on server card.
STO f3StorageDeviceExternalSsdStatus1.3.6.1.4.1.2544.1.12.3.1.101.1.2StorageStatusread-onlyIndicates status of external SSD on server card.
I32 f3StorageDeviceWearoutLevel1.3.6.1.4.1.2544.1.12.3.1.101.1.3Integer32read-onlyIndicated wearout level of internal SSD on server card.
cmEntityConformance1.3.6.1.4.1.2544.1.12.3.2
cmEntityCompliances1.3.6.1.4.1.2544.1.12.3.2.1
cmEntityCompliance1.3.6.1.4.1.2544.1.12.3.2.1.1Describes the requirements for conformance to the CM Entity group.
cmEntityGroups1.3.6.1.4.1.2544.1.12.3.2.2
cmEntityObjectGroup1.3.6.1.4.1.2544.1.12.3.2.2.1*************** THIS OBJECT GROUP IS DEPRECATED ****************** A collection of objects used to manage the CM Entity group.
commonEntityGroup1.3.6.1.4.1.2544.1.12.3.2.2.2A collection of common objects used to manage any F3 product family product.
psuGroup1.3.6.1.4.1.2544.1.12.3.2.2.3A collection of objects used to manage the F3 Power Supply units.
fanGroup1.3.6.1.4.1.2544.1.12.3.2.2.4A collection of objects used to manage the F3 Fan units.
hubshelfGroup1.3.6.1.4.1.2544.1.12.3.2.2.5A collection of objects used to manage the CM Hub Shelf entities.
nteGe206CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.6A collection of objects used to manage the GE206 Card.
nteGe201SyncECardGroup1.3.6.1.4.1.2544.1.12.3.2.2.7A collection of objects used to manage the GE201 Sync Ethernet Card.
nteGe201NonSyncECardGroup1.3.6.1.4.1.2544.1.12.3.2.2.8A collection of objects used to manage the GE201 Non SyncE Card.
nteGe206FCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.9A collection of objects used to manage the GE206F Card.
nteGe112CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.10A collection of objects used to manage the GE112 Card.
nteGe114CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.11A collection of objects used to manage the GE114 Card.
nteGe206VCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.12A collection of objects used to manage the GE206V Card.
nteXg210CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.13A collection of objects used to manage the XG210 Card.
pseudoWireCardOcnStmCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.14A collection of objects used to manage the Pseudo Wire OCN/STM Card.
pseudoWireCardE1T1CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.15A collection of objects used to manage the Pseudo Wire E1/T1 Card.
nteT1804CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.16A collection of objects used to manage the T1804 Card.
nteT3204CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.17A collection of objects used to manage the T3204 Card.
nteGeSyncProbeCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.18A collection of objects used to manage the GE SyncProbe Card.
xg1XCCCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.19A collection of objects used to manage the XG 1X CC Card.
xg1SCCCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.20A collection of objects used to manage the XG 1S CC Card.
ge4ECCCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.21A collection of objects used to manage the GE 4E CC Card.
ge4SCCCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.22A collection of objects used to manage the GE 4S CC Card.
ge8SCCCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.23A collection of objects used to manage the GE 8S CC Card.
nteGe114HCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.24A collection of objects used to manage the GE114H Card.
nteGe114PHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.25A collection of objects used to manage the GE114PH Card.
ethernetOverOCSTMCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.26A collection of objects used to manage the cards.
ethernet1x10GHighPerCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.27A collection of objects used to manage the cards.
ethernetFE36ECardGroup1.3.6.1.4.1.2544.1.12.3.2.2.28A collection of objects used to manage the cards.
nteGe114SHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.29A collection of objects used to manage the GE114SH Card.
nteGe114SCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.30A collection of objects used to manage the GE114S Card.
ge8ECCCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.31A collection of objects used to manage the GE 8E CC Card.
neLLDPParamsGroup1.3.6.1.4.1.2544.1.12.3.2.2.32A collection of objects used to manage the LLDP params on NE.
nteSh1PcsCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.33A collection of objects used to manage the SH1PCS Card.
nteOsa5411CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.34A collection of objects used to manage the OSA5411 Card.
nteGe112ProCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.35A collection of objects used to manage the GE112Pro Card.
nteGe112ProMCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.36A collection of objects used to manage the GE112ProM Card.
nteGe114ProCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.37A collection of objects used to manage the GE114Pro Card.
nteGe114ProCCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.38A collection of objects used to manage the GE114ProC Card.
nteGe114ProSHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.39A collection of objects used to manage the GE114ProSH Card.
nteGe114ProCSHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.40A collection of objects used to manage the GE114ProCSH Card.
nteGe114ProHECardGroup1.3.6.1.4.1.2544.1.12.3.2.2.41A collection of objects used to manage the GE114ProHE Card.
nteGe112ProHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.42A collection of objects used to manage the GE112ProH Card.
nteXg210CCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.43A collection of objects used to manage the XG210 Card.
geGE8SCryptoConnectorCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.44A collection of objects used to manage the GE 8S CC Card.
nteOsa5420CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.45A collection of objects used to manage the OSA5420 Card.
nteOsa5421CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.46A collection of objects used to manage the OSA5421 Card.
nteGe114GCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.47A collection of objects used to manage the GE114G Card.
bits16PortCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.48A collection of objects used to manage the BITS 16 PORT EXP Card.
nteGE114ProVmHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.49A collection of objects used to manage the GE114ProVmH Card.
nteGE114ProVmCHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.50A collection of objects used to manage the GE114ProVmCH Card.
nteGE114ProVmCSHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.51A collection of objects used to manage the GE114ProVmCSH Card.
serverCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.52A collection of objects used to manage the Server Card.
pps16PortCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.53A collection of objects used to manage the PPS 16 PORT EXP Card.
clk16PortCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.54A collection of objects used to manage the PPS 16 PORT EXP Card.
todPps16PortCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.55A collection of objects used to manage the PPS 16 PORT EXP Card.
nteGe101ProCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.56A collection of objects used to manage the GE101Pro Card.
nteGo102ProSCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.57A collection of objects used to manage the GO102ProS Card.
nteGo102ProSPCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.58A collection of objects used to manage the GO102ProSP Card.
nteCx101Pro30ACardGroup1.3.6.1.4.1.2544.1.12.3.2.2.59A collection of objects used to manage the CX101Pro30A Card.
nteCx102Pro30ACardGroup1.3.6.1.4.1.2544.1.12.3.2.2.60A collection of objects used to manage the CX102Pro30A Card.
ge4PortCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.61A collection of objects used to manage the GE 4 PORT EXP Card.
nteXg116ProCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.62A collection of objects used to manage the XG116PRO Card.
nteXg120ProCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.63A collection of objects used to manage the XG120PRO Card.
nteGE112ProVmCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.64A collection of objects used to manage the GE112ProVm Card.
nteOsa5401CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.65A collection of objects used to manage the OSA5401 Card.
nteOsa5405CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.66A collection of objects used to manage the OSA5405 Card.
csmCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.67A collection of objects used to manage the CSM Card.
auxPortCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.68A collection of objects used to manage the Auxiliary Port Expansion Card.
nteGe102ProHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.69A collection of objects used to manage the GE102Pro H Card.
nteGe102ProEFMHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.70A collection of objects used to manage the GE102Pro EFMH Card.
ethernetOsa3350MgntCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.71A collection of objects used to manage the OSA3350 Mgnt Card.
nteXg116ProHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.72A collection of objects used to manage the XG116PRO (H) Card.
nteGo102ProSMCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.73A collection of objects used to manage the GO102ProSM Card.
nteXg118ProSHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.74A collection of objects used to manage the XG118PRO (SH) Card.
nteXg118ProacSHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.75A collection of objects used to manage the XG118PROAC (SH) Card.
nteGE114ProVmSHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.76A collection of objects used to manage the GE114ProVmSH Card.
nteGE104CardGroup1.3.6.1.4.1.2544.1.12.3.2.2.77A collection of objects used to manage the GE104 Card.
nteXg120ProSHCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.78A collection of objects used to manage the XG120PROSH Card.
mbGnssCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.79A collection of objects used to manage the MB GNSS EXP Card.
f3IrigCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.80A collection of objects used to manage the IRIG Card.
compositeClockCardGroup1.3.6.1.4.1.2544.1.12.3.2.2.81A collection of objects used to manage the COMPOSITE CLOCK EXP Card.

FAQ

How does CM-ENTITY-MIB help track ADVA FSP150CM/CC network elements under management?
It exposes a network-element inventory table with each element's name, type, contact, physical location, and description, plus objects showing whether a discovered element has been accepted into management, giving an operator immediate visibility into which optical transport nodes are known and managed.

What would I check in CM-ENTITY-MIB if a newly installed FSP150 element isn't showing up as managed?
You'd check the element's management-acceptance status and provisioning-action objects in the network element table -- if the element hasn't been marked as accepted, that explains why it isn't fully under management even though it's been discovered.

RFC description

ADVA vendor-specific extension to ENTITY-MIB (RFC 2737) providing entity management for F3 FSP150CM/CC optical networking product lines.

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download CM-ENTITY-MIB