All MIBs › EKINOPS-MGNT2-MIB
Organization: Ekinops
Last Updated: 2017-01-10
Category: Domain: Optical Transport, Optical and WDM, Technology: Optical Transport, Vendor: Ekinops
Description: Ekinops Management v2 MIB for managing Ekinops optical transport equipment including card configuration and performance monitoring.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is EKINOPS-MGNT2-MIB?
EKINOPS-MGNT2-MIB is Ekinops' second-generation management MIB for its 360 optical transport platform, covering platform-wide SNMP manager/trap configuration, hardware inventory, and per-severity alarm notification enablement. It exposes objects to register one or more NMS manager IP addresses that should receive traps, per-severity trap-enable flags (critical/major/minor), and a hardware branch describing the chassis/card inventory. Its monitoring emphasis is on fault and software status rather than raw performance counters: the mgnt2GigmManagerEnableAlarmCrit/Major/Minor flags control which severities of hardware or transmission faults get reported, and mgnt2Hardware exposes card/module presence for hardware status tracking. It works together with EKINOPS-MGNT2-NMS-MIB, which carries the actual active alarm table, and the base EKINOPS-MIB for OID registration. It is deployed on Ekinops 360 modular optical transport/DWDM chassis in telecom and carrier network sites. Engineers can download the EKINOPS-MGNT2-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in EKINOPS-MGNT2-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Ekinops 360 optical transport/DWDM chassis
- Ekinops optical networking cards/modules
Monitoring Examples
An NMS administrator configures mgnt2GigmManagerIpAddressTable entries (mgnt2GigmManagerIpAddress, mgnt2GigmManagerTrapPort) so the Ekinops chassis knows where to send SNMP traps, then checks mgnt2GigmManagerEnableAlarmCrit/Major/Minor to confirm critical alarms are not accidentally suppressed. mgnt2GigmManagerEnableCtrl and mgnt2GigmManagerEnableConfig/Event are checked to verify trap forwarding is enabled for configuration-change and event notifications, not just alarms. mgnt2Hardware and mgnt2SNMPAgentData are polled to confirm the agent and hardware inventory are in the expected state after a card swap.
What Can Be Monitored
- configured NMS trap-receiver addresses and ports
- alarm severity notification enable flags (critical/major/minor)
- event and configuration-change trap enablement
- hardware/card inventory
- SNMP agent data
This MIB depends on
Related MIBs
Imported Objects
From EKINOPS-MIB
| EkiApiState | |
| EkiLoadGWSW | |
| EkiLoadPermutMethod | |
| EkiLoadPermutMode | |
| EkiLoadState | |
| EkiOnOff | |
| EkiProtocol | |
| EkiState | |
| EkiSynchroMode | |
| ekinops | MODULE-IDENTITY |
From SNMPv2-SMI
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString | |
| RowStatus | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| mgnt2 | 1.3.6.1.4.1.20044.7 | MIB for Ekinops 360 management. | ||
| mgnt2SNMPAgentData | 1.3.6.1.4.1.20044.7.1 | |||
| mgnt2IPmanagment | 1.3.6.1.4.1.20044.7.1.1 | |||
| mgnt2GigmManagerIpAddressTable | 1.3.6.1.4.1.20044.7.1.1.1 | not-accessible | Manager IP address Table. | |
| mgnt2GigmManagerIpAddressEntry | 1.3.6.1.4.1.20044.7.1.1.1.1 | not-accessible | ||
| I32 mgnt2GigmManagerIpIndex | 1.3.6.1.4.1.20044.7.1.1.1.1.1 | Integer32 | read-create | Index of the IP address of the manager |
| IP mgnt2GigmManagerIpAddress | 1.3.6.1.4.1.20044.7.1.1.1.1.2 | IpAddress | read-create | IP address of the manager:This OID defines the IP address of the SNMP Manager attached to the Mgnt2 |
| ROW mgnt2GigmManagerIpAddressTableRowStatus | 1.3.6.1.4.1.20044.7.1.1.1.1.3 | RowStatus | read-create | The status of this row. |
| I32 mgnt2GigmManagerTrapPort | 1.3.6.1.4.1.20044.7.1.1.1.1.4 | Integer32 | read-create | Manager UDP port. |
| EKI mgnt2GigmManagerEnableCtrl | 1.3.6.1.4.1.20044.7.1.1.1.1.5 | EkiOnOff | read-create | Enabling trap of Ctrl. |
| EKI mgnt2GigmManagerEnableConfig | 1.3.6.1.4.1.20044.7.1.1.1.1.6 | EkiOnOff | read-create | Enabling trap of config. |
| EKI mgnt2GigmManagerEnableEvent | 1.3.6.1.4.1.20044.7.1.1.1.1.7 | EkiOnOff | read-create | Enabling trap of event. |
| EKI mgnt2GigmManagerEnableAlarmCrit | 1.3.6.1.4.1.20044.7.1.1.1.1.8 | EkiOnOff | read-create | Enabling trap of crit alarm. |
| EKI mgnt2GigmManagerEnableAlarmMajor | 1.3.6.1.4.1.20044.7.1.1.1.1.9 | EkiOnOff | read-create | Enabling trap of major alarm. |
| EKI mgnt2GigmManagerEnableAlarmMinor | 1.3.6.1.4.1.20044.7.1.1.1.1.10 | EkiOnOff | read-create | Enabling trap of minor alarm. |
| I32 mgnt2GigmManagerRegistrationTimeout | 1.3.6.1.4.1.20044.7.1.1.1.1.11 | Integer32 | read-create | Time-out for manager activities. |
| EKI mgnt2GigmManagerEnableAlarmWarning | 1.3.6.1.4.1.20044.7.1.1.1.1.12 | EkiOnOff | read-create | Enabling trap of warning alarm. |
| EKI mgnt2GigmManagerEnableAlarmIndeterminate | 1.3.6.1.4.1.20044.7.1.1.1.1.13 | EkiOnOff | read-create | Enabling trap of indeterminate alarm. |
| IP mgnt2GigmBoardIpAddress | 1.3.6.1.4.1.20044.7.1.1.2 | IpAddress | read-write | IP address of the Chassis:This OID defines the IP address of the Mgnt2 |
| EKI mgnt2GigmIPAddresByDHCP | 1.3.6.1.4.1.20044.7.1.1.3 | EkiState | read-write | IP address retrieved by DHCP:If enabled, the IP address is retrieved by DHCP, in which case changes take effect after a board reset. If disabled the object, mgnt2GigmBoardIpAddress defines the address |
| IP mgnt2GigmNetmask | 1.3.6.1.4.1.20044.7.1.1.4 | IpAddress | read-write | Netmask for the board IP address:This OID defined the IP Subnet mask of the Mgnt2 |
| mgnt2GigmGatewayAddressTable | 1.3.6.1.4.1.20044.7.1.1.5 | not-accessible | Gateway IP address Table: This table contains all the gateway IP addresses. | |
| mgnt2GigmGatewayAddressEntry | 1.3.6.1.4.1.20044.7.1.1.5.1 | not-accessible | ||
| I32 mgnt2GigmGatewayIndex | 1.3.6.1.4.1.20044.7.1.1.5.1.1 | Integer32 | read-create | Index of the IP address of the gateway |
| IP mgnt2GigmGatewayAddress | 1.3.6.1.4.1.20044.7.1.1.5.1.2 | IpAddress | read-create | IP address of the gateway :This OID defines the IP address of the gateway attached to the Chassis |
| I32 mgnt2GigmGatewayOrder | 1.3.6.1.4.1.20044.7.1.1.5.1.3 | Integer32 | read-create | Gateway priority: This OID defines the priority of the gateway (lower number for higher priority) |
| IP mgnt2GigmSyslog | 1.3.6.1.4.1.20044.7.1.1.6 | IpAddress | read-write | IP address of the syslog server:This OID defines the IP address of the syslog of the Mgnt2 |
| IP mgnt2GigmNtpServer | 1.3.6.1.4.1.20044.7.1.1.7 | IpAddress | read-write | IP address of the ntp server:This OID defines the IP address of the ntp server for the Mgnt2 |
| IP mgnt2GigmNodeIpAddress | 1.3.6.1.4.1.20044.7.1.1.8 | IpAddress | read-write | Node IP address :This OID defines the Node IP address in node controller mode for the Mgnt2 |
| mgnt2ModulesManagement | 1.3.6.1.4.1.20044.7.1.2 | |||
| mgnt2GigmBoardTable | 1.3.6.1.4.1.20044.7.1.2.1 | not-accessible | List of PMs plugged in the Chassis | |
| mgnt2GigmBoardEntry | 1.3.6.1.4.1.20044.7.1.2.1.1 | not-accessible | Row Definition for the PMs table | |
| I32 mgnt2IndexBoards | 1.3.6.1.4.1.20044.7.1.2.1.1.1 | Integer32 | read-only | Index for PMs table |
| I32 mgnt2Position | 1.3.6.1.4.1.20044.7.1.2.1.1.2 | Integer32 | read-only | PM Slot number:This OID gives the slot number in which the PM is plugged |
| STR mgnt2Name | 1.3.6.1.4.1.20044.7.1.2.1.1.3 | DisplayString | read-only | PM name:This OID gives the name of the PM plugged in the Mgnt2 |
| I32 mgnt2PortNumber | 1.3.6.1.4.1.20044.7.1.2.1.1.4 | Integer32 | read-only | Number of Client Ports:This OID gives the number of client ports on the PM plugged in the Mgnt2 |
| I32 mgnt2LineNumber | 1.3.6.1.4.1.20044.7.1.2.1.1.5 | Integer32 | read-only | Number of Line Ports:This OID gives the number of line ports on the PM plugged in the Mgnt2 |
| I32 mgnt2GroupNumber | 1.3.6.1.4.1.20044.7.1.2.1.1.6 | Integer32 | read-only | Number of Groups:This OID gives the number of group of clients on the PM plugged in the Mgnt2 |
| OID mgnt2RootOIDInventory | 1.3.6.1.4.1.20044.7.1.2.1.1.7 | OBJECT IDENTIFIER | read-only | root oid of the inventory leaf of the corresponding PM |
| STR mgnt2SlotOcc | 1.3.6.1.4.1.20044.7.1.2.1.1.8 | DisplayString | read-only | PM Slot occupied:This OID gives the slots taken by this PM |
| STR mgnt2SubFunctionLabel | 1.3.6.1.4.1.20044.7.1.2.1.1.9 | DisplayString | read-only | Sub Function Label: This OID gives the name of the sub function embedded on the Chassis. (applied only on the 100G Chassis) |
| MGN mgnt2SlotStatus | 1.3.6.1.4.1.20044.7.1.2.1.1.10 | Mgnt2SlotStatus | read-only | Slot Status: This OID gives the status of the slot in the Chassis: See Textual COnvention |
| INT mgnt2GigmSelectedBoard | 1.3.6.1.4.1.20044.7.1.2.7 | INTEGER | read-write | PM Slot number selected:PM selected for further operations in the Ekinops module board tree. This number is the slot number. |
| mgnt2GigmMibsTable | 1.3.6.1.4.1.20044.7.1.4 | not-accessible | List of MIBs supported by the Chassis SNMPAgent | |
| mgnt2GigmMibsEntry | 1.3.6.1.4.1.20044.7.1.4.1 | not-accessible | Row definition for MIBs table | |
| I32 mgnt2IndexMibs | 1.3.6.1.4.1.20044.7.1.4.1.1 | Integer32 | read-only | Index for MIBs table |
| STR mgnt2MibName | 1.3.6.1.4.1.20044.7.1.4.1.2 | DisplayString | read-only | MIB name:This OID gives the name of the MIBs supported by the SNMP Agent |
| STR mgnt2MibPartNumber | 1.3.6.1.4.1.20044.7.1.4.1.3 | DisplayString | read-only | MIB Part Number:This OID gives the part number of the MIBs supported by the SNMP Agent |
| STR mgnt2GigmLogicalName | 1.3.6.1.4.1.20044.7.1.5 | DisplayString | read-write | Mgnt2 name:This OID defines the name of the Mgnt2 |
| I32 mgnt2GigmEqptType | 1.3.6.1.4.1.20044.7.1.6 | Integer32 | read-only | Equipment type:This OID defines the type of the Equipment |
| mgnt2GigmTrapCount | 1.3.6.1.4.1.20044.7.1.7 | |||
| I32 mgnt2GigmTrapCounter | 1.3.6.1.4.1.20044.7.1.7.1 | Integer32 | read-only | Trap counter:This OID counts the number of trap sent |
| EKI mgnt2GigmResetTrapCounter | 1.3.6.1.4.1.20044.7.1.7.2 | EkiOnOff | read-write | Reset trap counter:This OID reset the trap counter to 0 |
| mgnt2GigmSecurity | 1.3.6.1.4.1.20044.7.1.8 | |||
| STR mgnt2GigmRoCommunity | 1.3.6.1.4.1.20044.7.1.8.1 | DisplayString | read-write | SNMP Get community:This OID defines the community for the SNMP Get function |
| STR mgnt2GigmRwCommunity | 1.3.6.1.4.1.20044.7.1.8.2 | DisplayString | read-write | SNMP Set community:This OID defines the community for the SNMP Set function |
| STR mgnt2GigmTrapCommunity | 1.3.6.1.4.1.20044.7.1.8.3 | DisplayString | read-write | SNMP Trap community:This OID defines the community for the SNMP Trap function |
| mgnt2GigmTime | 1.3.6.1.4.1.20044.7.1.9 | |||
| INT mgnt2GigmCurrentHour | 1.3.6.1.4.1.20044.7.1.9.1 | INTEGER | read-write | Chassis Hour time:This OID defines the hour of the chassis' time |
| INT mgnt2GigmCurrentMinute | 1.3.6.1.4.1.20044.7.1.9.2 | INTEGER | read-write | Chassis Minute time:This OID defines the minute of the chassis' time |
| INT mgnt2GigmCurrentYear | 1.3.6.1.4.1.20044.7.1.9.3 | INTEGER | read-write | Chassis year date:This OID defines the year of the chassis' date |
| INT mgnt2GigmCurrentMonth | 1.3.6.1.4.1.20044.7.1.9.4 | INTEGER | read-write | Chassis month date:This OID defines the month of the chassis' date |
| INT mgnt2GigmCurrentDay | 1.3.6.1.4.1.20044.7.1.9.5 | INTEGER | read-write | Chassis day date:This OID defines the day of the chassis' date |
| mgnt2Authentication | 1.3.6.1.4.1.20044.7.1.10 | |||
| IP mgnt2GigmRadiusServer | 1.3.6.1.4.1.20044.7.1.10.1 | IpAddress | read-write | IP address of the RADIUS server:This OID defines the IP address of the external RADIUS server for authentication |
| I32 mgnt2GigmRadiusPort | 1.3.6.1.4.1.20044.7.1.10.2 | Integer32 | read-write | TCP port number of the RADIUS server:This OID defines the TCP port number of the external RADIUS server for authentication |
| STR mgnt2GigmRadiusSecret | 1.3.6.1.4.1.20044.7.1.10.3 | DisplayString | read-write | Shared secret of the RADIUS server:This OID defines the shared secret password of the RADIUS server for authentication |
| IP mgnt2GigmLdapHost | 1.3.6.1.4.1.20044.7.1.10.4 | IpAddress | read-write | IP address of the LDAP host:This OID defines the IP address of the external LDAP server for authentication |
| I32 mgnt2GigmLdapPort | 1.3.6.1.4.1.20044.7.1.10.5 | Integer32 | read-write | TCP port number of the LDAP server:This OID defines the TCP port number of the external LDAP server for authentication |
| STR mgnt2GigmLdapBase | 1.3.6.1.4.1.20044.7.1.10.6 | DisplayString | read-write | LDAP base:This OID defines the name of the search base of the LDAP server for authenticationLDAP base name spelled as follows: 'ou=users,ou=network,dc=yourcompany,dc=net' |
| I32 mgnt2GigmLdapVersion | 1.3.6.1.4.1.20044.7.1.10.7 | Integer32 | read-write | Protocol number in use by the LDAP server:This OID defines the protocol version used by the external LDAP server for authenticationProtocol version used by the external LDAP server for authentication |
| STR mgnt2GigmLdapBindDn | 1.3.6.1.4.1.20044.7.1.10.8 | DisplayString | read-write | LDAP Bind DN:This OID defines the login name used to connect into the LDAP server base for authenticationLDAP binddn spelled as follows: 'cn=ldap_admin,dc=yourcompany,dc=net' |
| STR mgnt2GigmLdapBindPw | 1.3.6.1.4.1.20044.7.1.10.9 | DisplayString | read-write | Credentials to bind the LDAP server with:This OID defines the credentials to bind the LDAP server with for authenticationCredentials for LDAP access (bindpw) |
| STR mgnt2GigmLdapScope | 1.3.6.1.4.1.20044.7.1.10.10 | DisplayString | read-write | Scope for LDAP base search:This OID defines the search scope for an LDAP base search LDAP search scope |
| STR mgnt2GigmLdapPamPasswd | 1.3.6.1.4.1.20044.7.1.10.11 | DisplayString | read-write | PAM password handling:This OID defines the way the PAM password is handled for LDAP authentication The 'pam_password' option sould be one of the following: 'clear', 'crypt', 'md5', 'racf', 'exop' |
| MGN mgnt2GigmAuthenticationType | 1.3.6.1.4.1.20044.7.1.10.12 | Mgnt2AuthTypeValues | read-write | Authentication type in use |
| mgnt2Hardware | 1.3.6.1.4.1.20044.7.2 | |||
| mgnt2alarms | 1.3.6.1.4.1.20044.7.2.1 | |||
| mgnt2AlmsynthAlm0 | 1.3.6.1.4.1.20044.7.2.1.0 | |||
| EKI mgnt2AlmAbsFailure | 1.3.6.1.4.1.20044.7.2.1.0.9 | EkiOnOff | read-only | Chassis Management Module Failure :This OID indicates that the Chassis Management module is in fail condition ABS_FAILURE other(1) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFansFailure | 1.3.6.1.4.1.20044.7.2.1.0.10 | EkiOnOff | read-only | Chassis Fan Module Failure :This OID indicates that at least one of the three FAN unit of the FAN module is in fail condition FANS_FAILURE other(1) equipmentAlarm (5) (2) |
| EKI mgnt2AlmDef48a | 1.3.6.1.4.1.20044.7.2.1.0.11 | EkiOnOff | read-only | Power Input A Present :This OID indicates that there is not input power on the right power connector (A) This alarm indicates if the power input B is present (left power connector) DEF_48A powerProblem (36) equipmentAlarm (5) (2) |
| EKI mgnt2AlmDef48b | 1.3.6.1.4.1.20044.7.2.1.0.12 | EkiOnOff | read-only | Power Input B Present :This OID indicates that there is not input power on the right power connector (B) This alarm indicates if the power input B is present (right power connector) DEF_48B powerProblem (36) equipmentAlarm (5) (2) |
| EKI mgnt2AlmMgntDefFuseA | 1.3.6.1.4.1.20044.7.2.1.0.15 | EkiOnOff | read-only | Mgnt Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Management board Status of the MGNT Fuse A MGNT_DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) |
| EKI mgnt2AlmMgntDefFuseB | 1.3.6.1.4.1.20044.7.2.1.0.16 | EkiOnOff | read-only | Mgnt Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Management board Status of the MGNT Fuse B MGNT_DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) |
| mgnt2AlmsynthAlm1 | 1.3.6.1.4.1.20044.7.2.1.1 | |||
| EKI mgnt2AlmNurgVisual | 1.3.6.1.4.1.20044.7.2.1.1.1 | EkiOnOff | read-only | Minor Chassis Alarm :This OID indicates at least one Minor alarm is active on the complete chassis (including TR-FAN, MGNT and PM) This alarm indicates at least one Minor alarm is active on the complete chassis (including TR-FAN, MGNT and PM) NURG_VISUAL other(1) other (1) (2) |
| EKI mgnt2AlmUrgVisual | 1.3.6.1.4.1.20044.7.2.1.1.2 | EkiOnOff | read-only | Major Chassis Alarm :This OID indicates at least one Major alarm is active on the complete chassis (including TR-FAN, MGNT and PM) This alarm indicates at least one Major alarm is active on the complete chassis (including TR-FAN, MGNT and PM) URG_VISUAL other(1) other (1) (2) |
| EKI mgnt2AlmCritVisual | 1.3.6.1.4.1.20044.7.2.1.1.3 | EkiOnOff | read-only | Critical Chassis Alarm :This OID indicates at least one Critical alarm is active on the complete chassis (including TR-FAN, MGNT and PM) This alarm indicates at least one Critical alarm is active on the complete chassis (including TR-FAN, MGNT and PM) CRIT_VISUAL other(1) other (1) (2) |
| EKI mgnt2AlmAcknowledge | 1.3.6.1.4.1.20044.7.2.1.1.16 | EkiOnOff | read-only | Alarm Ack. :This OID indicates the alarms have been acknowledged by the user (locally or remotely) This status indicates the alarms have been acknowledged by the user (locally or remotely) ACKNOWLEDGE other(1) other (1) (2) |
| mgnt2AlmboardMgmntSet1 | 1.3.6.1.4.1.20044.7.2.1.16 | |||
| EKI mgnt2AlmPmSlot1Absent | 1.3.6.1.4.1.20044.7.2.1.16.2 | EkiOnOff | read-only | PM present in Chassis slot 1 :This OID indicates the presence of a PM in Slot 1 of the Chassis . This status indicates if a PM is detected in slot 1 PM_SLOT1_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot2Absent | 1.3.6.1.4.1.20044.7.2.1.16.3 | EkiOnOff | read-only | PM present in Chassis slot 2 :This OID indicates the presence of a PM in Slot 2 of the Chassis . This status indicates if a PM is detected in slot 2 PM_SLOT2_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot3Absent | 1.3.6.1.4.1.20044.7.2.1.16.4 | EkiOnOff | read-only | PM present in Chassis slot 3 :This OID indicates the presence of a PM in Slot 3 of the Chassis . This status indicates if a PM is detected in slot 3 PM_SLOT3_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot4Absent | 1.3.6.1.4.1.20044.7.2.1.16.5 | EkiOnOff | read-only | PM present in Chassis slot 4 :This OID indicates the presence of a PM in Slot 4 of the Chassis . This status indicates if a PM is detected in slot 4 PM_SLOT4_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot5Absent | 1.3.6.1.4.1.20044.7.2.1.16.6 | EkiOnOff | read-only | PM present in Chassis slot 5 :This OID indicates the presence of a PM in Slot 5 of the Chassis . This status indicates if a PM is detected in slot 5 PM_SLOT5_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot6Absent | 1.3.6.1.4.1.20044.7.2.1.16.7 | EkiOnOff | read-only | PM present in Chassis slot 6 :This OID indicates the presence of a PM in Slot 6 of the Chassis . This status indicates if a PM is detected in slot 6 PM_SLOT6_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot7Absent | 1.3.6.1.4.1.20044.7.2.1.16.8 | EkiOnOff | read-only | PM present in Chassis slot 7 :This OID indicates the presence of a PM in Slot 7 of the Chassis . This status indicates if a PM is detected in slot 7 PM_SLOT7_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot8Absent | 1.3.6.1.4.1.20044.7.2.1.16.9 | EkiOnOff | read-only | PM present in Chassis slot 8 :This OID indicates the presence of a PM in Slot 8 of the Chassis . This status indicates if a PM is detected in slot 8 PM_SLOT8_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot9Absent | 1.3.6.1.4.1.20044.7.2.1.16.10 | EkiOnOff | read-only | PM present in Chassis slot 9 :This OID indicates the presence of a PM in Slot 9 of the Chassis . This status indicates if a PM is detected in slot 9 PM_SLOT9_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot10Absent | 1.3.6.1.4.1.20044.7.2.1.16.11 | EkiOnOff | read-only | PM present in Chassis slot 10 :This OID indicates the presence of a PM in Slot 10 of the Chassis . This status indicates if a PM is detected in slot 10 PM_SLOT10_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot11Absent | 1.3.6.1.4.1.20044.7.2.1.16.12 | EkiOnOff | read-only | PM present in Chassis slot 11 :This OID indicates the presence of a PM in Slot 11 of the Chassis . This status indicates if a PM is detected in slot 11 PM_SLOT11_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmFanAbsent | 1.3.6.1.4.1.20044.7.2.1.16.14 | EkiOnOff | read-only | FAN module present in Chassis :This OID indicates the presence of the FAN module in the Chassis. This alarm indicates if the FAN module is detected in the chassis. PM_FAN_ABSENT other(1) equipmentAlarm (5) (2) |
| mgnt2AlmboardMgmntSet2 | 1.3.6.1.4.1.20044.7.2.1.17 | |||
| EKI mgnt2AlmPmSlot12Absent | 1.3.6.1.4.1.20044.7.2.1.17.1 | EkiOnOff | read-only | PM present in Chassis slot 12 :This OID indicates the presence of a PM in Slot 12 of the Chassis . This status indicates if a PM is detected in slot 12 PM_SLOT12_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot13Absent | 1.3.6.1.4.1.20044.7.2.1.17.2 | EkiOnOff | read-only | PM present in Chassis slot 13 :This OID indicates the presence of a PM in Slot 13 of the Chassis . This status indicates if a PM is detected in slot 13 PM_SLOT13_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot14Absent | 1.3.6.1.4.1.20044.7.2.1.17.3 | EkiOnOff | read-only | PM present in Chassis slot 14 :This OID indicates the presence of a PM in Slot 14 of the Chassis . This status indicates if a PM is detected in slot 14 PM_SLOT14_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot15Absent | 1.3.6.1.4.1.20044.7.2.1.17.4 | EkiOnOff | read-only | PM present in Chassis slot 15 :This OID indicates the presence of a PM in Slot 15 of the Chassis . This status indicates if a PM is detected in slot 15 PM_SLOT15_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot16Absent | 1.3.6.1.4.1.20044.7.2.1.17.5 | EkiOnOff | read-only | PM present in Chassis slot 16 :This OID indicates the presence of a PM in Slot 16 of the Chassis . This status indicates if a PM is detected in slot 16 PM_SLOT16_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot17Absent | 1.3.6.1.4.1.20044.7.2.1.17.6 | EkiOnOff | read-only | PM present in Chassis slot 17 :This OID indicates the presence of a PM in Slot 17 of the Chassis . This status indicates if a PM is detected in slot 17 PM_SLOT17_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot18Absent | 1.3.6.1.4.1.20044.7.2.1.17.7 | EkiOnOff | read-only | PM present in Chassis slot 18 :This OID indicates the presence of a PM in Slot 18 of the Chassis . This status indicates if a PM is detected in slot 18 PM_SLOT18_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot19Absent | 1.3.6.1.4.1.20044.7.2.1.17.8 | EkiOnOff | read-only | PM present in Chassis slot 19 :This OID indicates the presence of a PM in Slot 19 of the Chassis . This status indicates if a PM is detected in slot 19 PM_SLOT19_ABSENT other(1) other (1) (2) |
| EKI mgnt2AlmPmSlot20Absent | 1.3.6.1.4.1.20044.7.2.1.17.9 | EkiOnOff | read-only | PM present in Chassis slot 20 :This OID indicates the presence of a PM in Slot 20 of the Chassis . This status indicates if a PM is detected in slot 20 PM_SLOT20_ABSENT other(1) other (1) (2) |
| mgnt2AlmfanMgmnt | 1.3.6.1.4.1.20044.7.2.1.20 | |||
| EKI mgnt2AlmPbFan1Fail | 1.3.6.1.4.1.20044.7.2.1.20.2 | EkiOnOff | read-only | Fan Unit #1 Failed On Fan Module :This OID indicates a failure on fan 1. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #1 is in fail condition PB_FAN1_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| EKI mgnt2AlmPbFan2Fail | 1.3.6.1.4.1.20044.7.2.1.20.3 | EkiOnOff | read-only | Fan Unit #2 Failed On Fan Module :This OID indicates a failure on fan 2. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #2 is in fail condition PB_FAN2_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| EKI mgnt2AlmPbFan3Fail | 1.3.6.1.4.1.20044.7.2.1.20.4 | EkiOnOff | read-only | Fan Unit #3 Failed On Fan Module :This OID indicates a failure on fan 3. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #3 is in fail condition PB_FAN3_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| EKI mgnt2AlmPbFan4Fail | 1.3.6.1.4.1.20044.7.2.1.20.5 | EkiOnOff | read-only | Fan Unit #4 Failed On Fan Module :This OID indicates a failure on fan 4. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #4 is in fail condition PB_FAN4_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| EKI mgnt2AlmPbFan5Fail | 1.3.6.1.4.1.20044.7.2.1.20.6 | EkiOnOff | read-only | Fan Unit #5 Failed On Fan Module :This OID indicates a failure on fan 5. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #5 is in fail condition PB_FAN5_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| EKI mgnt2AlmPbFan6Fail | 1.3.6.1.4.1.20044.7.2.1.20.7 | EkiOnOff | read-only | Fan Unit #6 Failed On Fan Module :This OID indicates a failure on fan 6. Removal of the fan unit or no rotation sets the OID. This alarm indicates if the FAN #6 is in fail condition PB_FAN6_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFanFilterAbsent | 1.3.6.1.4.1.20044.7.2.1.20.16 | EkiOnOff | read-only | Dust Filter Presence :This OID indicates that the dust filter is not present This alarm indicates if the Dust Filter is detected in the chassis. FAN_FILTER_ABSENT other(1) equipmentAlarm (5) (2) |
| mgnt2AlmfanPwrMgmnt | 1.3.6.1.4.1.20044.7.2.1.24 | |||
| EKI mgnt2AlmFanPwrProtOn | 1.3.6.1.4.1.20044.7.2.1.24.12 | EkiOnOff | read-only | Fan Backup Power :This OID indicates the backup power on the FAN module is switched on FAN_PWR_PROT_ON powerProblem (36) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFanPwrFail1 | 1.3.6.1.4.1.20044.7.2.1.24.13 | EkiOnOff | read-only | Fan Main Power :This OID indicates a failure on the main power of the FAN module This alarm indicates if one of the tow main power convert of the FAN module is in fail condition FAN_PWR_FAIL_1 powerProblem (36) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFanDefFuseA | 1.3.6.1.4.1.20044.7.2.1.24.15 | EkiOnOff | read-only | Fan Fuse A Fail :This OID indicates that the fuse of the power input A is in fail condition on the Fan board Status of the FAN Fuse A FAN_DEF_FUSE_A powerProblem (36) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFanDefFuseB | 1.3.6.1.4.1.20044.7.2.1.24.16 | EkiOnOff | read-only | Fan Fuse B Fail :This OID indicates that the fuse of the power input B is in fail condition on the Fan board Status of the FAN Fuse B FAN_DEF_FUSE_B powerProblem (36) equipmentAlarm (5) (2) |
| mgnt2AlmremoveablefanModuleFail | 1.3.6.1.4.1.20044.7.2.1.25 | |||
| EKI mgnt2AlmFan1ModuleAbsent | 1.3.6.1.4.1.20044.7.2.1.25.1 | EkiOnOff | read-only | FAN Module #1 Present In Chassis :This OID indicates the presence of the FAN module #1 in the Chassis. This alarm indicates if the FAN module #1 is detected in the chassis. FAN1_MODULE_ABSENT other(1) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFan2ModuleAbsent | 1.3.6.1.4.1.20044.7.2.1.25.2 | EkiOnOff | read-only | FAN Module #2 Present In Chassis :This OID indicates the presence of the FAN module #2 in the Chassis. This alarm indicates if the FAN module #2 is detected in the chassis. FAN2_MODULE_ABSENT other(1) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFan3ModuleAbsent | 1.3.6.1.4.1.20044.7.2.1.25.3 | EkiOnOff | read-only | FAN Module #3 Present In Chassis :This OID indicates the presence of the FAN module #3 in the Chassis. This alarm indicates if the FAN module #3 is detected in the chassis. FAN3_MODULE_ABSENT other(1) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFan4ModuleAbsent | 1.3.6.1.4.1.20044.7.2.1.25.4 | EkiOnOff | read-only | FAN Module #4 Present In Chassis :This OID indicates the presence of the FAN module #4 in the Chassis. This alarm indicates if the FAN module #4 is detected in the chassis. FAN4_MODULE_ABSENT other(1) equipmentAlarm (5) (2) |
| mgnt2AlmremoveableFanModuleMgmnt | 1.3.6.1.4.1.20044.7.2.1.26 | |||
| EKI mgnt2AlmFan1ModuleFail | 1.3.6.1.4.1.20044.7.2.1.26.1 | EkiOnOff | read-only | FAN Module #1 Failure :This OID indicates a failure on FAN module #1 This alarm indicates if the FAN module #1 is in fail condition FAN1_MODULE_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFan2ModuleFail | 1.3.6.1.4.1.20044.7.2.1.26.2 | EkiOnOff | read-only | FAN Module #2 Failure :This OID indicates a failure on FAN module #2 This alarm indicates if the FAN module #2 is in fail condition FAN2_MODULE_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFan3ModuleFail | 1.3.6.1.4.1.20044.7.2.1.26.3 | EkiOnOff | read-only | FAN Module #3 Failure :This OID indicates a failure on FAN module #3 This alarm indicates if the FAN module #3 is in fail condition FAN3_MODULE_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFan4ModuleFail | 1.3.6.1.4.1.20044.7.2.1.26.4 | EkiOnOff | read-only | FAN Module #4 Failure :This OID indicates a failure on FAN module #4 This alarm indicates if the FAN module #4 is in fail condition FAN4_MODULE_FAIL heatingVentCoolingSystemProblem (22) equipmentAlarm (5) (2) |
| mgnt2AlmswAlarm1 | 1.3.6.1.4.1.20044.7.2.1.32 | |||
| EKI mgnt2AlmApiError | 1.3.6.1.4.1.20044.7.2.1.32.1 | EkiOnOff | read-only | Comm fail between Agent and Transport :This OID indicates a failure detected on the Agent.The failure is located on a communication process with the modules. This alarm indicates if there is a communication mismatch between the MGNT board and a single PM API_ERROR adapterError (2) equipmentAlarm (5) (2) |
| EKI mgnt2AlmFifoCmdError | 1.3.6.1.4.1.20044.7.2.1.32.2 | EkiOnOff | read-only | SNMP Agent to Transport comm FIFO fail :This OID indicates a failure inside the FIFO stack. The FIFO containing the messages from the agent (write) to the PMs is full This alarm indicates if there is a communication mismatch between the MGNT board and all PM FIFO_CMD_ERROR adapterError (2) equipmentAlarm (5) (2) |
| EKI mgnt2AlmPollingManagerError | 1.3.6.1.4.1.20044.7.2.1.32.3 | EkiOnOff | read-only | Polling Manager fail :This OID indicates a failure on the Manager polling the PM's This alarm indicates if there is a polling manager failure between the MGNT and the Pm's POLLING_MANAGER_ERROR adapterError (2) equipmentAlarm (5) (2) |
| INT mgnt2AlmapiErrorCode | 1.3.6.1.4.1.20044.7.2.1.33 | INTEGER | read-only | API Error Identification :Error number and description of the abs1AlmApiError object API_ERROR_CODE_1 |
| mgnt2AlmlogMgmnt | 1.3.6.1.4.1.20044.7.2.1.34 | |||
| EKI mgnt2AlmLogFileFull | 1.3.6.1.4.1.20044.7.2.1.34.1 | EkiOnOff | read-only | Log File Full Alarm :This OID indicates that a log file is full. This file must be cleared to insure correct log function This alarm indicates that one of the log file is Full LOG_FILE_FULL fileError (18) equipmentAlarm (5) (2) |
| EKI mgnt2AlmLog80Full | 1.3.6.1.4.1.20044.7.2.1.34.2 | EkiOnOff | read-only | Log File Full Warning :This OID indicates that a log file is 80% full. This alarm indicates that one of the log file is 80% Full LOG_80_FULL fileError (18) equipmentAlarm (5) (2) |
| mgnt2AlmNtpSyncLoss | 1.3.6.1.4.1.20044.7.2.1.35 | |||
| EKI mgnt2AlmCpuTempOverRange | 1.3.6.1.4.1.20044.7.2.1.35.2 | EkiOnOff | read-only | CPU HighTemperature Warning :This OID indicates a temperature over the expected range on the CPU This warning indicates that the temperature of the CPU is reaching its internal limit CPU_TEMP_OVER_RANGE other(1) equipmentAlarm (5) (2) |
| mgnt2controls | 1.3.6.1.4.1.20044.7.2.2 | |||
| mgnt2Ctrlsynth5 | 1.3.6.1.4.1.20044.7.2.2.5 | |||
| EKI mgnt2CtrlChassisShutdown | 1.3.6.1.4.1.20044.7.2.2.5.2 | EkiOnOff | read-write | Shut Down of the Management Module :This OID shall be set before shutting down the Chassis power. A delay of 5 sec is necessary between this OID is set and power is shut down. This control initiates a shutdown of the MGNT board, |
| EKI mgnt2CtrlChassisWarmReset | 1.3.6.1.4.1.20044.7.2.2.5.3 | EkiOnOff | read-write | Reset of the Management Module :This oid triggers a 'warm' reset of the Chassis . This type of reset is not traffic affecting and the modules configuration remains unchanged. This control initiates a warm reset of the MGNT board, |
| EKI mgnt2CtrlChassisColdReset | 1.3.6.1.4.1.20044.7.2.2.5.4 | EkiOnOff | read-write | Cold Reset of the Management Module :This oid triggers a 'cold' reset of the Chassis . This type of reset is not traffic affecting and the modules configuration remains unchanged. This control initiates a cold reset of the MGNT board, |
| mgnt2CtrltestLed | 1.3.6.1.4.1.20044.7.2.2.18 | |||
| EKI mgnt2CtrlGreenLed | 1.3.6.1.4.1.20044.7.2.2.18.1 | EkiOnOff | read-write | Green Leds Test :This OID switches on all the green Leds as a test feature This control initiates a test leds turning all the LEDs of the chassis to green |
| EKI mgnt2CtrlRedLed | 1.3.6.1.4.1.20044.7.2.2.18.2 | EkiOnOff | read-write | Red Leds Test :This OID switches on all the red Leds as a test feature This control initiates a test leds turning all the LEDs of the chassis to red |
| EKI mgnt2CtrlLedOff | 1.3.6.1.4.1.20044.7.2.2.18.3 | EkiOnOff | read-write | Switch off Leds Test :This OID switches off all the Leds as a test feature This control initiates a test leds turning all the LEDs of the complete chassis to OFF |
| mgnt2CtrllogFile | 1.3.6.1.4.1.20044.7.2.2.19 | |||
| EKI mgnt2CtrlLogFileReset | 1.3.6.1.4.1.20044.7.2.2.19.1 | EkiOnOff | read-write | Log File Reset :This OID clears all the log files |
| mgnt2CtrlmgntSaveConfig | 1.3.6.1.4.1.20044.7.2.2.23 | |||
| EKI mgnt2CtrlSaveConfig | 1.3.6.1.4.1.20044.7.2.2.23.1 | EkiOnOff | read-write | Save Configuration :This OID is used save the configuration related to the enable and mode traps objects This control saves the customer configuration on the MGNT board |
| mgnt2CtrlmgntGetGlobalConfig | 1.3.6.1.4.1.20044.7.2.2.24 | |||
| EKI mgnt2CtrlGetGlobalConfig | 1.3.6.1.4.1.20044.7.2.2.24.1 | EkiOnOff | read-write | Get Global Chassis Config :This OID is used to create a global configuration file of the chassis This control creates a single configuration file from PM's and MGNT configuration file into the RAM |
| mgnt2CtrlmgntPutGlobalConfig | 1.3.6.1.4.1.20044.7.2.2.25 | |||
| EKI mgnt2CtrlPutGlobalConfig | 1.3.6.1.4.1.20044.7.2.2.25.1 | EkiOnOff | read-write | Put Global Chassis Config :This OID is used to extract a global configuration file of the chassis This control creates configuration files to PM's and MGNT from a single configuration file in the RAM |
| mgnt2CtrlmgntAcknowledge | 1.3.6.1.4.1.20044.7.2.2.26 | |||
| EKI mgnt2CtrlAcknowledge | 1.3.6.1.4.1.20044.7.2.2.26.1 | EkiOnOff | read-write | Alarm Ack. :This OID is used to acknowledge the current active alarms of the chassis This control is used to acknowledge the current active alarms of the chassis |
| mgnt2config | 1.3.6.1.4.1.20044.7.2.3 | |||
| mgnt2CfgethPort2 | 1.3.6.1.4.1.20044.7.2.3.17 | |||
| EKI mgnt2CfgEthPort2Disable | 1.3.6.1.4.1.20044.7.2.3.17.1 | EkiOnOff | read-write | 2nd Ethernet Port Disable :This OID disables 'Ethernet Port 2' .When not required, this port must be disabled in order to prevent unwanted access. Disable the second Ethernet port |
| EKI mgnt2CfgChassisEthernetSplit | 1.3.6.1.4.1.20044.7.2.3.17.2 | EkiOnOff | read-write | Chassis Ethernet Split :This OID enables the split between the two kendings. Enable/Disable the switch between the two kendings |
| MGN mgnt2CfgmgntDccEnable | 1.3.6.1.4.1.20044.7.2.3.18 | Mgnt2DccAccessValues | read-write | DCC Access :This OID selects the mode to enable the DCC on the slots. This Mode enables the Slots 2-4-6-8-10 , or the Slots 2-6-10-14-18. Defines the DCC access on the backplane of the chassis (Slots 2-4-6-8-10 or Slots 2-6-10-14-18) |
| mgnt2CfgpmTrapEnable | 1.3.6.1.4.1.20044.7.2.3.20 | |||
| EKI mgnt2CfgPmCriticalTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.1 | EkiOnOff | read-write | Critical Alarm Traps Enable :This OID, when set, enables the generation of the critical alarm trap for all the PM plugged in the chassis In detailed traps mechanism, enable the trap emission on critical alarm detected on PM |
| EKI mgnt2CfgPmMajorTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.2 | EkiOnOff | read-write | Major Alarm Traps Enable :This OID, when set, enables the generation of the major alarm trap for all the PM plugged in the chassis In detailed traps mechanism, enable the trap emission on major alarm detected on PM |
| EKI mgnt2CfgPmMinorTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.3 | EkiOnOff | read-write | Minor Alarm Traps Enable :This OID, when set, enables the generation of the minor alarm trap for all the PM plugged in the chassis In detailed traps mechanism, enable the trap emission on minor alarm detected on PM |
| EKI mgnt2CfgPmControlTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.5 | EkiOnOff | read-write | Control Traps Enable :This OID, when set, enables the generation of a trap when a control is sent to a PM plugged in the chassis In detailed traps mechanism, enable the trap emission on control sent to PM |
| EKI mgnt2CfgPmConfigTrapEn | 1.3.6.1.4.1.20044.7.2.3.20.6 | EkiOnOff | read-write | Config Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a PM plugged in the chassis is modified In detailed traps mechanism, enable the trap emission on PM configuration modificatio |
| mgnt2CfgmgntTrapEnable | 1.3.6.1.4.1.20044.7.2.3.21 | |||
| EKI mgnt2CfgMgntCriticalTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.1 | EkiOnOff | read-write | MGNT Critical Alarm Traps Enable :This OID, when set, enables the generation of the critical alarm trap for the MGNT and FAN board In detailed traps mechanism, enable the trap emission on critical alarm detected on MGNT and FAN |
| EKI mgnt2CfgMgntMajorTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.2 | EkiOnOff | read-write | MGNT Major Traps Enable :This OID, when set, enables the generation of the major alarm trap for the MGNT and FAN board In detailed traps mechanism, enable the trap emission on major alarm detected on MGNT and FAN |
| EKI mgnt2CfgMgntMinorTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.3 | EkiOnOff | read-write | MGNT Minor Alarm Traps Enable :This OID, when set, enables the generation of the minor alarm trap for the MGNT and FAN board In detailed traps mechanism, enable the trap emission on minor alarm detected on MGNT and FAN |
| EKI mgnt2CfgMgntControlTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.5 | EkiOnOff | read-write | MGNT Control Traps Enable :This OID, when set, enables the generation of a trap when a control is sent to a MGNT plugged in the chassis In detailed traps mechanism, enable the trap emission on control sent to MGNT |
| EKI mgnt2CfgMgntConfigTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.6 | EkiOnOff | read-write | MGNT Config Traps Enable :This OID, when set, enables the generation of a trap when the configuration of a MGNT plugged in the chassis is modified In detailed traps mechanism, enable the trap emission on MGNT configuration modification |
| EKI mgnt2CfgMgntEventTrapEn | 1.3.6.1.4.1.20044.7.2.3.21.7 | EkiOnOff | read-write | MGNT Event Traps Enable :This OID, when set, enables the generation of a trap when an event occurs on the chassis In detailed traps mechanism, enable the trap emission on event detected in the chassis |
| MGN mgnt2CfgmgntTrapMode | 1.3.6.1.4.1.20044.7.2.3.22 | Mgnt2TrapModeValues | read-write | Traps Mode :This OID is used to define the trap mode (synthetic or detailed mode) Selects the traps mechanism |
| mgnt2CfgsyslogEnable | 1.3.6.1.4.1.20044.7.2.3.23 | |||
| EKI mgnt2CfgSyslogEventEn | 1.3.6.1.4.1.20044.7.2.3.23.1 | EkiOnOff | read-write | Syslog Event Enable :This OID, when set, enables the generation of a syslog, when an event has been detected Enable a syslog emission on event detected on the chassis |
| EKI mgnt2CfgSyslogConfigEn | 1.3.6.1.4.1.20044.7.2.3.23.2 | EkiOnOff | read-write | Syslog Config Enable :This OID, when set, enables the generation of a syslog, when the configuration has been changed. Enable a syslog emission on a configuration change detected on the chassis |
| EKI mgnt2CfgSyslogCtrlEn | 1.3.6.1.4.1.20044.7.2.3.23.3 | EkiOnOff | read-write | Syslog Control Enable :This OID, when set, enables the generation of a syslog, when a control is set Enable a syslog emission on a control operated on the chassis |
| EKI mgnt2CfgSyslogAlarmEn | 1.3.6.1.4.1.20044.7.2.3.23.4 | EkiOnOff | read-write | Syslog Alarm Enable :This OID, when set, enables the generation of a syslog, when an alarm occurs Enable a syslog emission on an alarm detected on the chassi |
| INT mgnt2CfgntpTimeZone | 1.3.6.1.4.1.20044.7.2.3.24 | INTEGER | read-write | NTP Time Zone :This OID defines the time zone of the MGNT board for the NTP server This object defines the time zone of the MGNT board (from -12 to +12 hours from the GMT). |
| mgnt2CfgpmConfEnable | 1.3.6.1.4.1.20044.7.2.3.25 | |||
| EKI mgnt2CfgPmBackupEnable | 1.3.6.1.4.1.20044.7.2.3.25.1 | EkiOnOff | read-write | Automatic Config Backup :This OID enables the automatic PM configuration backup mechanism on PM insertion or PM configuration modification. This parameter enables the automatic PM configuration backup mechanism on PM insertion or PM configuration modificatio |
| EKI mgnt2CfgPmRestoreEnable | 1.3.6.1.4.1.20044.7.2.3.25.2 | EkiOnOff | read-write | Automatic Config Restore :This OID enables the automatic PM configuration restore mechanism on PM insertion This parameter enables the automatic PM configuration restore mechanism on PM insertio |
| INT mgnt2CfginactivityTimeout | 1.3.6.1.4.1.20044.7.2.3.26 | INTEGER | read-write | Idle Timeout :This OID defines the idle timeout (in minutes) to automatically logout from the craft and from the CLI. This object defines the idle timeout (in minutes) to automatically logout from the craft and from the CLI |
| MGN mgnt2CfgcliAccess | 1.3.6.1.4.1.20044.7.2.3.27 | Mgnt2CliAccessValues | read-write | CLI access :This OID selects the protocol for the remote access to a CLI user. This object defines the protocol used for a remote CLI. |
| MGN mgnt2CfgcraftAccess | 1.3.6.1.4.1.20044.7.2.3.28 | Mgnt2CraftAccessValues | read-write | CRAFT access :This OID selects the remote access to a CRAFT user. This object defines the access for a remote CRAFT. |
| EKI mgnt2CfgperfModes1 | 1.3.6.1.4.1.20044.7.2.3.29 | EkiSynchroMode | read-write | PERF Synchro Source :This OID selects the source of the synchronisation (Internal/External). This object defines the source of the synchronization to operate performance monitoring. |
| MGN mgnt2CfgalarmModelActiv | 1.3.6.1.4.1.20044.7.2.3.30 | Mgnt2AckMode | read-write | Acknowledge mode :This OID defines the alarms akcnowledge mode This configuration defines the alarms akcnowledge mode |
| MGN mgnt2CfgnetworkInput | 1.3.6.1.4.1.20044.7.2.3.31 | Mgnt2NetMode | read-write | Network input :This OID selects the connection of the Ethernet Network input to either the switches (2) or the daughter board (1) , in this case the MGNT can act as a router This configuration defines the use of the Network input of the front panel |
| MGN mgnt2CfgmasterEthMode | 1.3.6.1.4.1.20044.7.2.3.32 | Mgnt2MasterEthMode | read-write | DHCP Master Ethernet Mode :This OID selects the mode of the Master Ethernet in DHCP mode (2) or in Static Mode(1) This configuration defines the use of the Master Ethernet Mode |
| MGN mgnt2CfgsubnetMode | 1.3.6.1.4.1.20044.7.2.3.33 | Mgnt2SubnetEthMode | read-write | DHCP Subnet Mode :This OID selects the mode of the Subnet in DHCP mode (2) or in Static Mode(1) This configuration defines the use of the Subnet Mode |
| mgnt2CfgrstpMode | 1.3.6.1.4.1.20044.7.2.3.34 | |||
| EKI mgnt2CfgRstpEnable | 1.3.6.1.4.1.20044.7.2.3.34.1 | EkiOnOff | read-write | RSTP Enable :This OID enables the RSTP algorythm This configuration defines the use of RSTP |
| mgnt2CfglldpMode | 1.3.6.1.4.1.20044.7.2.3.35 | |||
| EKI mgnt2CfgLldpEnable | 1.3.6.1.4.1.20044.7.2.3.35.1 | EkiOnOff | read-write | LLDP Enable :This OID enables the LLDP algorythm This configuration defines the use of LLDP |
| MGN mgnt2CfglogMode | 1.3.6.1.4.1.20044.7.2.3.36 | Mgnt2LogFileMode | read-write | Log Mode :This OID enables the log file mode This configuration defines the use of the log mod |
| mgnt2CfgnodeMode | 1.3.6.1.4.1.20044.7.2.3.37 | |||
| EKI mgnt2CfgNodeControllerEnable | 1.3.6.1.4.1.20044.7.2.3.37.1 | EkiOnOff | read-write | Node Controller Mode :This OID enables the node controller mode This configuration defines the use of the node controller mod |
| mgnt2CfgunprivilegedUsersMode | 1.3.6.1.4.1.20044.7.2.3.38 | |||
| EKI mgnt2CfgRestrictUnprivilegeUsers | 1.3.6.1.4.1.20044.7.2.3.38.1 | EkiOnOff | read-write | Restrict Unprivileged Users Rights :This OID enables the restriction of unprivileged user rights to modify their own password This parameter enables the restriction of unprivileged user rights to modify their own password |
| INT mgnt2CfgoscDccLinkUpThreshold | 1.3.6.1.4.1.20044.7.2.3.39 | INTEGER | read-write | OSC/DCC Link Up Thresh. [10-30]s :This OID defines the confirmation threshold to consider an OSC/DCC link as up This parameter defines the confirmation threshold to consider an OSC/DCC link as up |
| INT mgnt2CfgoscDccLinkDownThreshold | 1.3.6.1.4.1.20044.7.2.3.40 | INTEGER | read-write | OSC/DCC Link Down Thresh. [2-3]s :This OID defines the confirmation threshold to consider an OSC/DCC link as down This parameter defines the confirmation threshold to consider an OSC/DCC link as down. |
| INT mgnt2CfgaccountAutoLock | 1.3.6.1.4.1.20044.7.2.3.41 | INTEGER | read-write | Account Auto-Lock [-1 / 1-10] err :This OID defines the number of error password to lock an account. This counter is reset on successful login or after an administrator defined period (see Fail count reset) Set to -1 to disables the feature. This parameter defines the number of error password to lock an account. This counter is reset on successful login or after an administrator defined period (see Fail count reset) Set to -1 to disables the feature. |
| INT mgnt2CfgfailCountReset | 1.3.6.1.4.1.20044.7.2.3.42 | INTEGER | read-write | Fail Count Reset [-1 / 1-10] hrs :This OID defines the minimum time (in hours) to reset the failed login counter. This counter is also reset on successful login. Set to -1 to disable the feature. This parameter defines the minimum time (in hours) to reset the failed login counter. This counter is also reset on successful login. Set to -1 to disable the feature |
| mgnt2CfgftpMode | 1.3.6.1.4.1.20044.7.2.3.44 | |||
| EKI mgnt2CfgFtpEnable | 1.3.6.1.4.1.20044.7.2.3.44.1 | EkiOnOff | read-write | FTP Enable :This OID enables the FTP protocol This configuration enables the FTP protocol |
| mgnt2CfgtftpMode | 1.3.6.1.4.1.20044.7.2.3.45 | |||
| EKI mgnt2CfgTftpEnable | 1.3.6.1.4.1.20044.7.2.3.45.1 | EkiOnOff | read-write | TFTP Enable :This OID enables the TFTP protocol This configuration enables the TFTP protocol |
| mgnt2Traps | 1.3.6.1.4.1.20044.7.3 | |||
| NTF mgnt2TrapApi | 1.3.6.1.4.1.20044.7.3.1 | Api error trap with its number | ||
| NTF mgnt2TrapSwError | 1.3.6.1.4.1.20044.7.3.2 | Chassis software error other API | ||
| NTF mgnt2TrapBoardInserted | 1.3.6.1.4.1.20044.7.3.4 | A board has been plugged in | ||
| NTF mgnt2TrapBoardRemoved | 1.3.6.1.4.1.20044.7.3.5 | A board has been plugged out | ||
| NTF mgnt2TrapRestoreConfDone | 1.3.6.1.4.1.20044.7.3.6 | The Configuration has been restored from the management board | ||
| NTF mgnt2TrapGlobalPowerFail | 1.3.6.1.4.1.20044.7.3.8 | A global power supply failure has been detected | ||
| NTF mgnt2TrapFanPowerFail | 1.3.6.1.4.1.20044.7.3.9 | A Fan power supply failure has been detected | ||
| NTF mgnt2TrapGigmPowerFail | 1.3.6.1.4.1.20044.7.3.10 | A power supply default has been detected in the management board | ||
| NTF mgnt2TrapFanFail | 1.3.6.1.4.1.20044.7.3.11 | A Fan failure has been detected | ||
| NTF mgnt2TrapLogFileFull | 1.3.6.1.4.1.20044.7.3.20 | Indicates that the corresponding log file is almost full | ||
| NTF mgnt2TrapAlarm | 1.3.6.1.4.1.20044.7.3.30 | Indicates that an alarm state has changed | ||
| NTF mgnt2TrapEvent | 1.3.6.1.4.1.20044.7.3.31 | Indicates that an event has occured | ||
| NTF mgnt2TrapControl | 1.3.6.1.4.1.20044.7.3.32 | Indicates that a control has been set to the module | ||
| NTF mgnt2TrapConfig | 1.3.6.1.4.1.20044.7.3.33 | Indicates that a config word has been changed | ||
| INT mgnt2TrapBoardNumber | 1.3.6.1.4.1.20044.7.3.50 | INTEGER | read-only | This OID gives the slot number of the PM that sent the last trap |
| STR mgnt2TrapSeverity | 1.3.6.1.4.1.20044.7.3.51 | DisplayString | read-only | This OID gives the trap severity |
| STR mgnt2TrapSourcePm | 1.3.6.1.4.1.20044.7.3.52 | DisplayString | read-only | This OID gives the mnemonic of the pm who sent a trap |
| STR mgnt2TrapSourcePortType | 1.3.6.1.4.1.20044.7.3.53 | DisplayString | read-only | This OID gives the type of the port who sent a trap |
| INT mgnt2TrapSourcePortNumber | 1.3.6.1.4.1.20044.7.3.54 | INTEGER | read-only | This OID gives the port number of the PM that sent the last trap |
| STR mgnt2TrapSourceLabel | 1.3.6.1.4.1.20044.7.3.55 | DisplayString | read-only | This OID gives the label of the alarm who sent a trap |
| EKI mgnt2TrapSourceValue | 1.3.6.1.4.1.20044.7.3.56 | EkiOnOff | read-only | This OID gives the value of the alarm who sent a trap |
| STR mgnt2TrapEventLabel | 1.3.6.1.4.1.20044.7.3.57 | DisplayString | read-only | This OID gives the label of the event |
| IP mgnt2TrapNodeControllerIpAddress | 1.3.6.1.4.1.20044.7.3.58 | IpAddress | read-only | This OID gives the IP address of the Node Controller |
| STR mgnt2TrapChassisId | 1.3.6.1.4.1.20044.7.3.59 | DisplayString | read-only | This OID gives the chassis ID |
| mgnt2SoftwareManagement | 1.3.6.1.4.1.20044.7.4 | |||
| mgnt2DwlUploadingTable | 1.3.6.1.4.1.20044.7.4.1 | not-accessible | SNMP Agent SW packages in ram: List of the SNMP agent software packages available in /ram for download on the Chassis managment module flash | |
| mgnt2DwlUploadingEntry | 1.3.6.1.4.1.20044.7.4.1.1 | not-accessible | Row definition for the package uploading table | |
| I32 mgnt2IndexUpload | 1.3.6.1.4.1.20044.7.4.1.1.1 | Integer32 | read-only | Index for uploading table |
| STR mgnt2DwlUploadFileName | 1.3.6.1.4.1.20044.7.4.1.1.2 | DisplayString | read-only | Package filename in RAM:This OID gives the name of the SNMP agent software packages in RAM |
| EKI mgnt2ImmediateReplacement | 1.3.6.1.4.1.20044.7.4.1.1.3 | EkiState | read-write | Immediat Agent Replacement:This OID indicates to switch to selected SNMP agent immediately or after reset of the MGNT2 |
| EKI mgnt2FileUpload | 1.3.6.1.4.1.20044.7.4.1.1.4 | EkiOnOff | read-write | Agent File Upload:This OID validates the upload of the SNMP agent from RAM to FLASH |
| EKI mgnt2DeletePackageFromRam | 1.3.6.1.4.1.20044.7.4.1.1.5 | EkiOnOff | read-write | Delete Package from RAM:This OID requests to delete the SNMP Agent SW package from RAM |
| EKI mgnt2FlashingInProgress | 1.3.6.1.4.1.20044.7.4.1.1.6 | EkiOnOff | read-only | Flashing in Progress:This OID indicates whether there is a file upload to FLASH in progress |
| mgnt2DwlPackageTable | 1.3.6.1.4.1.20044.7.4.2 | not-accessible | List of SNMP agent software packages present in flash memory | |
| mgnt2DwlPackageEntry | 1.3.6.1.4.1.20044.7.4.2.1 | not-accessible | Row definition for the package management table | |
| I32 mgnt2IndexPackage | 1.3.6.1.4.1.20044.7.4.2.1.1 | Integer32 | read-only | Index for package management table |
| STR mgnt2DwlPackageFileName | 1.3.6.1.4.1.20044.7.4.2.1.2 | DisplayString | read-only | Package File name in FLASH:This OID gives the name of the SNMP agent software package in FLASH |
| EKI mgnt2ExtractedPack | 1.3.6.1.4.1.20044.7.4.2.1.3 | EkiOnOff | read-only | Extracted SNMP agent software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted |
| EKI mgnt2SwitchTo | 1.3.6.1.4.1.20044.7.4.2.1.4 | EkiOnOff | read-write | Switch to package:This OID activates the SNMP Agent Software package |
| EKI mgnt2Immediate | 1.3.6.1.4.1.20044.7.4.2.1.5 | EkiOnOff | read-write | Immediate SNMP agent activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next reset |
| EKI mgnt2DeletePackageFromFlash | 1.3.6.1.4.1.20044.7.4.2.1.6 | EkiOnOff | read-write | Delete package from FLASH:This OID deletes the SNMP agent software package from the FLASH |
| EKI mgnt2PackageExtractionInProgress | 1.3.6.1.4.1.20044.7.4.2.1.7 | EkiOnOff | read-only | Package extraction in progress:This OID indicates that a SNMP agent software activation is in progress |
| EKI mgnt2DwlUploadingTableUpdate | 1.3.6.1.4.1.20044.7.4.3 | EkiOnOff | read-write | Uploading Table update:This OID updates the contents of the uploading table |
| mgnt2LoadPMTable | 1.3.6.1.4.1.20044.7.4.4 | not-accessible | List of the PM module software files (GW/SW) present on the repository | |
| mgnt2LoadPMEntry | 1.3.6.1.4.1.20044.7.4.4.1 | not-accessible | Row definition for the LOAD article table | |
| I32 mgnt2LoadPMIndex | 1.3.6.1.4.1.20044.7.4.4.1.1 | Integer32 | read-only | Index for Load article table |
| STR mgnt2LoadFileName | 1.3.6.1.4.1.20044.7.4.4.1.2 | DisplayString | read-only | PM Upgrade filename:This OID gives the name of the file |
| EKI mgnt2LoadFileType | 1.3.6.1.4.1.20044.7.4.4.1.3 | EkiLoadGWSW | read-only | PM upgrade file type:This OID gives the type of file (gateware or software) |
| EKI mgnt2LoadState | 1.3.6.1.4.1.20044.7.4.4.1.4 | EkiLoadState | read-only | PM upgrade status:This OID gives the status of the selected Load file |
| I32 mgnt2LoadModuleNumber | 1.3.6.1.4.1.20044.7.4.4.1.5 | Integer32 | read-write | PM ugprade target:This OID defines the slot number of the PM to upgrade |
| EKI mgnt2LoadResetMethod | 1.3.6.1.4.1.20044.7.4.4.1.6 | EkiLoadPermutMethod | read-write | PM upgrade reset method:This OID defines the reset method (manual, immediate or scheduled) |
| EKI mgnt2LoadResetMode | 1.3.6.1.4.1.20044.7.4.4.1.7 | EkiLoadPermutMode | read-write | PM upgrade reset mode:This OID defines the type of reset (cold or warm) |
| I32 mgnt2LoadBankNumber | 1.3.6.1.4.1.20044.7.4.4.1.8 | Integer32 | read-write | PM upgrade bank number:This OID defines the target bank number in the PM's flash |
| I32 mgnt2LoadDownloadProgress | 1.3.6.1.4.1.20044.7.4.4.1.9 | Integer32 | read-only | PM upgrade progress:This OID gives the upgrade progress (percentage) |
| EKI mgnt2LoadTransfer | 1.3.6.1.4.1.20044.7.4.4.1.10 | EkiOnOff | read-write | PM upgrade transfer:This OID launchs the transfer of the associated file to the selected PM's flash |
| EKI mgnt2LoadDelete | 1.3.6.1.4.1.20044.7.4.4.1.11 | EkiOnOff | read-write | PM upgrade delete file:This OID deletes the associated file from the RAM of the management board |
| EKI mgnt2LoadPMTableUpdate | 1.3.6.1.4.1.20044.7.4.5 | EkiOnOff | read-write | Load PM Table update:This OID updates the contents of the Load table |
| mgnt2DwlEkicraftPkgTable | 1.3.6.1.4.1.20044.7.4.6 | not-accessible | List of Ekicraft software packages present in flash memory | |
| mgnt2DwlEkicraftPkgEntry | 1.3.6.1.4.1.20044.7.4.6.1 | not-accessible | Row definition for the package management table | |
| I32 mgnt2IndexEkicraftPkg | 1.3.6.1.4.1.20044.7.4.6.1.1 | Integer32 | read-only | Index for Ekicraft package management table |
| STR mgnt2DwlEkicraftPkgFileName | 1.3.6.1.4.1.20044.7.4.6.1.2 | DisplayString | read-only | Package File name in FLASH:This OID gives the name of the Ekicraft software package in FLASH |
| EKI mgnt2DwlEkicraftExtractedPack | 1.3.6.1.4.1.20044.7.4.6.1.3 | EkiOnOff | read-only | Extracted Ekicraft software pack.: Indicates whether the package is currently extracted in the FLASH. If it is, it must not be deleted |
| EKI mgnt2DwlEkicraftSwitchTo | 1.3.6.1.4.1.20044.7.4.6.1.4 | EkiOnOff | read-write | Switch to package:This OID activates the Ekicraft Software package |
| EKI mgnt2DwlEkicraftImmediate | 1.3.6.1.4.1.20044.7.4.6.1.5 | EkiOnOff | read-write | Immediate Ekicraft activation: This OID indicates whether the package is scheduled for immediate activation or activation will take place following the next reset |
| EKI mgnt2DeleteEkicraftPkgFromFlash | 1.3.6.1.4.1.20044.7.4.6.1.6 | EkiOnOff | read-write | Delete package from FLASH:This OID deletes the Ekicraft software package from the FLASH |
| EKI mgnt2EkicraftPkgExtractionInProgress | 1.3.6.1.4.1.20044.7.4.6.1.7 | EkiOnOff | read-only | Package extraction in progress:This OID indicates that an Ekicraft activation is in progress |
| mgnt2ConfigManagement | 1.3.6.1.4.1.20044.7.5 | |||
| mgnt2CnfUploadConfigFilesTable | 1.3.6.1.4.1.20044.7.5.1 | not-accessible | List of configuration files uploaded to RAM | |
| mgnt2CnfUploadConfigFilesEntry | 1.3.6.1.4.1.20044.7.5.1.1 | not-accessible | Row definition for the package uploading table | |
| I32 mgnt2CnfUploadConfigIndex | 1.3.6.1.4.1.20044.7.5.1.1.1 | Integer32 | read-only | Index of config files |
| STR mgnt2CnfConfigFileName | 1.3.6.1.4.1.20044.7.5.1.1.2 | DisplayString | read-only | Configuration filename in RAM:This OID gives the name of the configuration file in RAM |
| I32 mgnt2CnfConfigSlot | 1.3.6.1.4.1.20044.7.5.1.1.3 | Integer32 | read-write | Configuration target:This OID defines the target slot number for the configuration file |
| EKI mgnt2CnfConfigUpload | 1.3.6.1.4.1.20044.7.5.1.1.4 | EkiOnOff | read-write | Configuration Upload:This OID uploads the configuration file to the specified slot number in the PM FLASH |
| EKI mgnt2CnfDeleteConfigFile | 1.3.6.1.4.1.20044.7.5.1.1.5 | EkiOnOff | read-write | Configuration delete from RAM:This OID deletes the configuration file from RAM |
| mgnt2CnfManageConfigFilesTable | 1.3.6.1.4.1.20044.7.5.2 | not-accessible | List of configuration files uploaded to RAM | |
| mgnt2CnfManageConfigFilesEntry | 1.3.6.1.4.1.20044.7.5.2.1 | not-accessible | Row definition for the package uploading table | |
| I32 mgnt2CnfManageConfigIndex | 1.3.6.1.4.1.20044.7.5.2.1.1 | Integer32 | read-only | Index of config file slots |
| STR mgnt2CnfManageConfigFileID | 1.3.6.1.4.1.20044.7.5.2.1.2 | DisplayString | read-write | Configuration file ID in FLASH:This OID gives the ID of the configuration file in MGNT2 FLASH |
| STR mgnt2CnfManageConfigFileName | 1.3.6.1.4.1.20044.7.5.2.1.3 | DisplayString | read-write | Configuration file name in FLASH:This OID gives the name of the configuration file in MGNT2 FLASH |
| I32 mgnt2CnfModuleSlotNumber | 1.3.6.1.4.1.20044.7.5.2.1.4 | Integer32 | read-write | Configuration target:This OID defines the target module slot number for the configuration file |
| EKI mgnt2CnfBackupConfig | 1.3.6.1.4.1.20044.7.5.2.1.5 | EkiOnOff | read-write | Configuration backup:This OID backups the configuration of the specified module to the selected file in MGNT2 FLASH |
| EKI mgnt2CnfRestoreConfig | 1.3.6.1.4.1.20044.7.5.2.1.6 | EkiOnOff | read-write | Configuration Restore:This OID restores the configuration of the specified module from the selected file in MGNT2 FLASH |
| EKI mgnt2CnfExportConfig | 1.3.6.1.4.1.20044.7.5.2.1.7 | EkiOnOff | read-write | Configuration Export:This OID exports the selected file in MGNT2 FLASH to a file in RAM |
| EKI mgnt2CnfDeleteConfig | 1.3.6.1.4.1.20044.7.5.2.1.8 | EkiOnOff | read-write | Configuration delete from FLASH:This OID deletes the configuration file from the MGNT2 FLASH |
| mgnt2RemoteInventory | 1.3.6.1.4.1.20044.7.6 | |||
| STR mgnt2RinvHwPlatform | 1.3.6.1.4.1.20044.7.6.1 | DisplayString | read-write | Chassis Hardware inventory:This OID gives the Hardware inventory of the Mgnt2 management module |
| STR mgnt2RinvSoftwarePackage | 1.3.6.1.4.1.20044.7.6.2 | DisplayString | read-write | Chassis Software package inventory:this OID gives the Software package inventory of the Mgnt2 management module |
| STR mgnt2RinvGateware | 1.3.6.1.4.1.20044.7.6.3 | DisplayString | read-write | Chassis Gateware inventory:This OID gives the gateware inventory of the Mgnt2 management module |
| STR mgnt2RinvAgent | 1.3.6.1.4.1.20044.7.6.4 | DisplayString | read-write | Chassis Software inventory:This OID gives the software inventory of the Mgnt2 management module |
| STR mgnt2RinvCraft | 1.3.6.1.4.1.20044.7.6.5 | DisplayString | read-write | Chassis Craft inventory:This OID gives the craft inventory of the Mgnt2 management module |
| STR mgnt2RinvLinux | 1.3.6.1.4.1.20044.7.6.6 | DisplayString | read-write | Chassis Linux inventory:This OID gives the linux inventory of the Mgnt2 management module |
| mgnt2GigmPlugInTable | 1.3.6.1.4.1.20044.7.6.7 | not-accessible | List of Plug-ins present | |
| mgnt2GigmPlugInEntry | 1.3.6.1.4.1.20044.7.6.7.1 | not-accessible | Row Definition for the Plug-ins table | |
| I32 mgnt2IndexPlugIns | 1.3.6.1.4.1.20044.7.6.7.1.1 | Integer32 | read-only | Index for PMs table |
| STR mgnt2PlugInRinv | 1.3.6.1.4.1.20044.7.6.7.1.2 | DisplayString | read-only | Plug-in RI:This OID gives the remote inventory of the plug-in |
| EKI mgnt2PollingPresent | 1.3.6.1.4.1.20044.7.6.7.1.3 | EkiPlugInState | read-only | Polling present:This OID gives the presence of the polling plug-in |
| EKI mgnt2SnmpPresent | 1.3.6.1.4.1.20044.7.6.7.1.4 | EkiPlugInState | read-only | Snmp present:This OID gives the presence of the snmp plug-in |
| STR mgnt2RinvBackpanel | 1.3.6.1.4.1.20044.7.6.8 | DisplayString | read-write | Backpanel inventory:This OID gives the Backpanel inventory of the chassis |
| STR mgnt2RinvFan | 1.3.6.1.4.1.20044.7.6.9 | DisplayString | read-write | Fan inventory:This OID gives the fan inventory of the chassis |
| STR mgnt2RinvUboot | 1.3.6.1.4.1.20044.7.6.10 | DisplayString | read-write | U-Boot inventory:This OID gives the U-Boot inventory |
| mgnt2ErrorCounters | 1.3.6.1.4.1.20044.7.7 | |||
| mgnt2GigmErrorCounterTable | 1.3.6.1.4.1.20044.7.7.1 | not-accessible | List of error counters | |
| mgnt2GigmErrorCounterEntry | 1.3.6.1.4.1.20044.7.7.1.1 | not-accessible | Row Definition for the error counters table | |
| I32 mgnt2IndexErrorCounter | 1.3.6.1.4.1.20044.7.7.1.1.1 | Integer32 | read-only | Index for error counters table |
| I32 mgnt2ErrorCounterSlotNumber | 1.3.6.1.4.1.20044.7.7.1.1.2 | Integer32 | read-only | Slot number:This OID gives the slot number for the corresponding counter |
| I32 mgnt2ErrorCounterValue | 1.3.6.1.4.1.20044.7.7.1.1.3 | Integer32 | read-only | Count value:This OID gives the value of the error counter |
| EKI mgnt2GigmResetErrorCounters | 1.3.6.1.4.1.20044.7.7.2 | EkiOnOff | read-write | Reset error counters:This OID reset the error counters to 0 |
| mgnt2Perf | 1.3.6.1.4.1.20044.7.8 | |||
| mgnt2PerfCapabilityTable | 1.3.6.1.4.1.20044.7.8.1 | not-accessible | List of Perf capability of PMs plugged in the Chassis | |
| mgnt2PerfCapabilityEntry | 1.3.6.1.4.1.20044.7.8.1.1 | not-accessible | Row Definition for the Perf capability table | |
| I32 mgnt2PerfCapIndexBoards | 1.3.6.1.4.1.20044.7.8.1.1.1 | Integer32 | read-only | Index for Perf cap table |
| I32 mgnt2PerfCapPosition | 1.3.6.1.4.1.20044.7.8.1.1.2 | Integer32 | read-only | PM Slot number:This OID gives the slot number in which the PM is plugged |
| STR mgnt2PerfCapName | 1.3.6.1.4.1.20044.7.8.1.1.3 | DisplayString | read-only | PM name:This OID gives the name of the PM plugged in the Mgnt2 |
| EKI mgnt2PerfCapStatus | 1.3.6.1.4.1.20044.7.8.1.1.4 | EkiOnOff | read-only | Status of the perf cap:This OID gives the capability of the pm to do performance |
| OID mgnt2PerfCapOidEnable | 1.3.6.1.4.1.20044.7.8.1.1.5 | OBJECT IDENTIFIER | read-only | OID of the object perf enable:This OID gives the OID of the perf enable object of the correspondind mib of the module |
| EKI mgnt2GigmPerf15minSync | 1.3.6.1.4.1.20044.7.8.2 | EkiOnOff | read-write | 15 min sync perf : this oid send a 15min sync to all modules |
| EKI mgnt2GigmPerf24hSync | 1.3.6.1.4.1.20044.7.8.3 | EkiOnOff | read-write | 15 min sync perf : this oid send a 24h sync to all modules |
| MGN mgnt2PerfResyncNMS | 1.3.6.1.4.1.20044.7.8.4 | Mgnt2PerfResyncValues | read-write | Resync Perf : this oid allows to create an historical perf file for all modules |
RFC description
Vendor-private MIB for Ekinops optical networking equipment management.
Start monitoring Ekinops 360 optical transport/DWDM chassis (manager/trap config) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.