psuTemperature

Module: CM-ENTITY-MIB

OID (symbolic): CM-ENTITY-MIB::psuTemperature

OID (numeric): 1.3.6.1.4.1.2544.1.12.3.1.4.1.7

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Temperature of the PSU.

What is psuTemperature?

This OID holds a numeric reading of the internal temperature (in degrees) of a power supply unit. Monitoring temperature is essential because overheating indicates power supply failure or cooling problems. Data center monitoring systems watch this metric to trigger alerts before a power supply fails and causes equipment to shut down unexpectedly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.4.1.7
snmpwalk -v2c -c public <target> CM-ENTITY-MIB::psuTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.4.1.7.1
snmpget -v2c -c public <target> CM-ENTITY-MIB::psuTemperature.1

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-ENTITY-MIB::psuTemperature OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

How to Use in IPNetwork Monitor

Select an ADVA/Ceragon FSP150 CM/CC microwave and Carrier Ethernet transport platform as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type psuTemperature into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the power supply unit's current temperature. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high PSU temperature often precedes thermal shutdown or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.3cmEntityMIBCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1cmEntityObjectsCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.4psuTableCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.4.1psuEntryCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.4.1.7psuTemperatureCM-ENTITY-MIB