CM-ENTITY-MIB :: ethernetNTEGO102ProSCardSnmpDyingGaspEnabled

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-ENTITY-MIBethernetNTEGO102ProSCardSnmpDyingGaspEnabled

ethernetNTEGO102ProSCardSnmpDyingGaspEnabled

Module: CM-ENTITY-MIB

OID (symbolic): CM-ENTITY-MIB::ethernetNTEGO102ProSCardSnmpDyingGaspEnabled

OID (numeric): 1.3.6.1.4.1.2544.1.12.3.1.75.1.7

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Whether or not SNMP dying gasp is enabled on the Ethernet NTE GO102ProS Card.

What is ethernetNTEGO102ProSCardSnmpDyingGaspEnabled?

This read-write TruthValue turns the SNMP dying-gasp feature on or off for the Ethernet NTE GO102ProS Card, controlling whether the card sends a last-gasp notification trap when it loses power. It matters because, when enabled, the Ethernet NTE GO102ProS Card can alert the management system to an imminent power loss using the residual energy left in its capacitors, giving a few extra seconds of warning that a plain poll-based check would miss. For example, an operator enables this object on the Ethernet NTE GO102ProS Card at a remote unmanned site so a sudden power failure there still generates an immediate trap instead of just going silent until the next poll times out.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.75.1.7
snmpwalk -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGO102ProSCardSnmpDyingGaspEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.75.1.7.1
snmpget -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGO102ProSCardSnmpDyingGaspEnabled.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.3.1.75.1.7.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-ENTITY-MIB::ethernetNTEGO102ProSCardSnmpDyingGaspEnabled OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.3cmEntityMIBCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1cmEntityObjectsCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.75ethernetNTEGO102ProSCardTableCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.75.1ethernetNTEGO102ProSCardEntryCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.75.1.7ethernetNTEGO102ProSCardSnmpDyingGaspEnabledCM-ENTITY-MIB