ethernetNTEGE114HCardSnmpDyingGaspEnabled

Module: CM-ENTITY-MIB

OID (symbolic): CM-ENTITY-MIB::ethernetNTEGE114HCardSnmpDyingGaspEnabled

OID (numeric): 1.3.6.1.4.1.2544.1.12.3.1.42.1.7

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Whether or not SNMP dying gasp is enabled on the Ethernet NTE GE114H Card.

What is ethernetNTEGE114HCardSnmpDyingGaspEnabled?

This read-write TruthValue toggles whether the Ethernet NTE GE114H Card sends an SNMP dying-gasp notification — a trap fired using residual power at the moment of a power loss — when it unexpectedly loses power. Admins enable this so a sudden power loss on the Ethernet NTE GE114H Card still generates an alert instead of the card just silently dropping off the network, which is what lets a NOC tell a power outage apart from, say, a planned card removal. When troubleshooting an Ethernet NTE GE114H Card that keeps vanishing from the management system without any prior alarm, an admin would check whether this object is set to true, since a disabled dying gasp would explain the silent disappearance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.42.1.7
snmpwalk -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGE114HCardSnmpDyingGaspEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.42.1.7.1
snmpget -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGE114HCardSnmpDyingGaspEnabled.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.3.1.42.1.7.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-ENTITY-MIB::ethernetNTEGE114HCardSnmpDyingGaspEnabled OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.3cmEntityMIBCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1cmEntityObjectsCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.42ethernetNTEGE114HCardTableCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.42.1ethernetNTEGE114HCardEntryCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.42.1.7ethernetNTEGE114HCardSnmpDyingGaspEnabledCM-ENTITY-MIB