CM-ENTITY-MIB :: ethernetNTET1804CardSnmpDyingGaspEnabled

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-ENTITY-MIBethernetNTET1804CardSnmpDyingGaspEnabled

ethernetNTET1804CardSnmpDyingGaspEnabled

Module: CM-ENTITY-MIB

OID (symbolic): CM-ENTITY-MIB::ethernetNTET1804CardSnmpDyingGaspEnabled

OID (numeric): 1.3.6.1.4.1.2544.1.12.3.1.38.1.7

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Whether or not SNMP dying gasp is enabled on the Ethernet NTE T1804 Card.

What is ethernetNTET1804CardSnmpDyingGaspEnabled?

This read-write TruthValue toggles whether the Ethernet NTE T1804 Card sends an SNMP dying-gasp notification — a trap fired using residual power at the moment of a power loss — when it unexpectedly loses power. Admins enable this so a sudden power loss on the Ethernet NTE T1804 Card still generates an alert instead of the card just silently dropping off the network, which is what lets a NOC tell a power outage apart from, say, a planned card removal. A field team deploying the Ethernet NTE T1804 Card at a remote, unstaffed site would set this object to true so a power interruption there is reported immediately rather than only discovered on the next scheduled visit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.38.1.7
snmpwalk -v2c -c public <target> CM-ENTITY-MIB::ethernetNTET1804CardSnmpDyingGaspEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.38.1.7.1
snmpget -v2c -c public <target> CM-ENTITY-MIB::ethernetNTET1804CardSnmpDyingGaspEnabled.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.3.1.38.1.7.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-ENTITY-MIB::ethernetNTET1804CardSnmpDyingGaspEnabled OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.3cmEntityMIBCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1cmEntityObjectsCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.38ethernetNTET1804CardTableCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.38.1ethernetNTET1804CardEntryCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.38.1.7ethernetNTET1804CardSnmpDyingGaspEnabledCM-ENTITY-MIB