All MIBs › CM-ENTITY-MIB › ethernetNTEGE206FCardFineGrainedPmInterval
ethernetNTEGE206FCardFineGrainedPmInterval
Module: CM-ENTITY-MIB
OID (symbolic): CM-ENTITY-MIB::ethernetNTEGE206FCardFineGrainedPmInterval
OID (numeric): 1.3.6.1.4.1.2544.1.12.3.1.17.1.9
Node type: OBJECT-TYPE
Type: CmPmIntervalType
Access: read-write
Description: Allows specification of the fine-grained PM interval at the card level. This applies to all monitored PM entities. The default value of this attribute is interval-15min. Valid values are interval-5min and interval-15min. interval-1day and rollover are not considered fine-grained intervals.
What is ethernetNTEGE206FCardFineGrainedPmInterval?
This read-write CmPmIntervalType value sets the fine-grained performance-monitoring collection interval for every monitored PM entity on the Ethernet NTE GE206F card, choosing between interval-5min and interval-15min, with interval-15min as the default. It matters to an administrator tuning visibility into short-lived error bursts, since a 5-minute bucket surfaces problems that a 15-minute bucket would average away. For example, an engineer chasing an intermittent errored-seconds spike on the Ethernet NTE GE206F card would set this OID to interval-5min to get finer time resolution on the PM counters, instead of relying on interval-1day rollups.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.17.1.9 snmpwalk -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGE206FCardFineGrainedPmInterval
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.17.1.9.1 snmpget -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGE206FCardFineGrainedPmInterval.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.3.1.17.1.9.1 s <value>
Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-ENTITY-MIB::ethernetNTEGE206FCardFineGrainedPmInterval OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.2544 | advaMIB | ADVA-MIB |
| 1.3.6.1.4.1.2544.1 | products | ADVA-MIB |
| 1.3.6.1.4.1.2544.1.12 | fsp150cm | ADVA-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2544.1.12.3 | cmEntityMIB | CM-ENTITY-MIB |
| 1.3.6.1.4.1.2544.1.12.3.1 | cmEntityObjects | CM-ENTITY-MIB |
| 1.3.6.1.4.1.2544.1.12.3.1.17 | ethernetNTEGE206FCardTable | CM-ENTITY-MIB |
| 1.3.6.1.4.1.2544.1.12.3.1.17.1 | ethernetNTEGE206FCardEntry | CM-ENTITY-MIB |
| 1.3.6.1.4.1.2544.1.12.3.1.17.1.9 | ethernetNTEGE206FCardFineGrainedPmInterval | CM-ENTITY-MIB |