CM-ENTITY-MIB :: ethernetNTEGE112ProCardSnmpDyingGaspEnabled

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCM-ENTITY-MIBethernetNTEGE112ProCardSnmpDyingGaspEnabled

ethernetNTEGE112ProCardSnmpDyingGaspEnabled

Module: CM-ENTITY-MIB

OID (symbolic): CM-ENTITY-MIB::ethernetNTEGE112ProCardSnmpDyingGaspEnabled

OID (numeric): 1.3.6.1.4.1.2544.1.12.3.1.53.1.7

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Whether or not SNMP dying gasp is enabled on the Ethernet NTE GE112Pro Card.

What is ethernetNTEGE112ProCardSnmpDyingGaspEnabled?

This read-write TruthValue toggles whether the Ethernet NTE GE112Pro Card sends an SNMP dying-gasp notification — a trap fired using residual power at the moment of a power loss — when it unexpectedly loses power. Admins enable this so a sudden power loss on the Ethernet NTE GE112Pro Card still generates an alert instead of the card just silently dropping off the network, which is what lets a NOC tell a power outage apart from, say, a planned card removal. A field team deploying the Ethernet NTE GE112Pro Card at a remote, unstaffed site would set this object to true so a power interruption there is reported immediately rather than only discovered on the next scheduled visit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.53.1.7
snmpwalk -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGE112ProCardSnmpDyingGaspEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.53.1.7.1
snmpget -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGE112ProCardSnmpDyingGaspEnabled.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.3.1.53.1.7.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-ENTITY-MIB::ethernetNTEGE112ProCardSnmpDyingGaspEnabled OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.3cmEntityMIBCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1cmEntityObjectsCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.53ethernetNTEGE112ProCardTableCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.53.1ethernetNTEGE112ProCardEntryCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.53.1.7ethernetNTEGE112ProCardSnmpDyingGaspEnabledCM-ENTITY-MIB