Module: CM-ENTITY-MIB

OID (symbolic): CM-ENTITY-MIB::ethernetNTEGE206CardSnmpDyingGaspEnabled

OID (numeric): 1.3.6.1.4.1.2544.1.12.3.1.11.1.7

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Whether or not SNMP dying gasp is enabled on the Ethernet NTE GE206 Card.

What is ethernetNTEGE206CardSnmpDyingGaspEnabled?

This read-write TruthValue turns on or off the SNMP dying-gasp trap for the Ethernet NTE GE206 card, a last-gasp notification the card tries to send the moment it loses power. Enabling it lets a monitoring station distinguish a graceful power-down from a silent crash, since the card gets one final message out before it goes dark. For example, if a Ethernet NTE GE206 card loses power during a site outage, an operator with this object enabled would receive a dying-gasp trap instead of just seeing the card vanish from polling with no explanation.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.11.1.7
snmpwalk -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGE206CardSnmpDyingGaspEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2544.1.12.3.1.11.1.7.1
snmpget -v2c -c public <target> CM-ENTITY-MIB::ethernetNTEGE206CardSnmpDyingGaspEnabled.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2544.1.12.3.1.11.1.7.1 s <value>

Start monitoring ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CM-ENTITY-MIB::ethernetNTEGE206CardSnmpDyingGaspEnabled OID value, configure state conditions and alerts, and monitor any ADVA/Ceragon FSP150 CM/CC (F3) microwave & Carrier Ethernet transport platform from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2544advaMIBADVA-MIB
1.3.6.1.4.1.2544.1productsADVA-MIB
1.3.6.1.4.1.2544.1.12fsp150cmADVA-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2544.1.12.3cmEntityMIBCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1cmEntityObjectsCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.11ethernetNTEGE206CardTableCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.11.1ethernetNTEGE206CardEntryCM-ENTITY-MIB
1.3.6.1.4.1.2544.1.12.3.1.11.1.7ethernetNTEGE206CardSnmpDyingGaspEnabledCM-ENTITY-MIB