CISCO-MGX82XX-SONET-MIB :: cwSonetPathIntervalFCs

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCISCO-MGX82XX-SONET-MIBcwSonetPathIntervalFCs

cwSonetPathIntervalFCs

Module: CISCO-MGX82XX-SONET-MIB

OID (symbolic): CISCO-MGX82XX-SONET-MIB::cwSonetPathIntervalFCs

OID (numeric): 1.3.6.1.4.1.351.110.4.6.1.5.3.1.7

Node type: OBJECT-TYPE

Type: Gauge

Access: read-only

Description: Number of times that Path was in AIS or LOP alarm in a particular 15-minute interval in the past 24 hours.

What is cwSonetPathIntervalFCs?

This counts how many separate AIS or LOP alarm entries occurred within one specific, already-completed 15-minute bucket in this path's interval history. Finding a nonzero count in an otherwise quiet stretch of interval history tells an admin the exact quarter-hour a flapping event happened, which is useful evidence when correlating a customer's brief-outage complaint against a precise timestamp. If interval 20 (about 5 hours ago) shows a value of 3 while all later intervals show 0, that pinpoints a resolved flapping episode roughly 5 hours before the current query.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.351.110.4.6.1.5.3.1.7
snmpwalk -v2c -c public <target> CISCO-MGX82XX-SONET-MIB::cwSonetPathIntervalFCs

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.351.110.4.6.1.5.3.1.7.1
snmpget -v2c -c public <target> CISCO-MGX82XX-SONET-MIB::cwSonetPathIntervalFCs.1

Start monitoring Cisco WAN switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CISCO-MGX82XX-SONET-MIB::cwSonetPathIntervalFCs OID value, configure state conditions and alerts, and monitor any Cisco WAN switches from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.351stratacomCISCOWAN-SMI
1.3.6.1.4.1.351.110basisBASIS-MIB
1.3.6.1.4.1.351.110.4basisLinesBASIS-MIB
1.3.6.1.4.1.351.110.4.6sonetBASIS-MIB
1.3.6.1.4.1.351.110.4.6.1cwsonetObjectsBASIS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.351.110.4.6.1.5cwsonetPathCISCO-MGX82XX-SONET-MIB
1.3.6.1.4.1.351.110.4.6.1.5.3cwSonetPathIntervalTableCISCO-MGX82XX-SONET-MIB
1.3.6.1.4.1.351.110.4.6.1.5.3.1cwSonetPathIntervalEntryCISCO-MGX82XX-SONET-MIB
1.3.6.1.4.1.351.110.4.6.1.5.3.1.7cwSonetPathIntervalFCsCISCO-MGX82XX-SONET-MIB