All MIBs › CDD-564
Organization: Comtech EF Data Corp.
Last Updated: 2005--1-2-
Category: Satellite, Vendor: Comtech EF Data
Description: Manages Comtech EF Data CDD-564 satellite modem demodulator configuration including symbol rate, FEC, and demodulator status.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is CDD-564?
CDD-564 is a Comtech EF Data vendor-specific MIB that manages and monitors the CDD-564 satellite demodulator, exposing configuration for demodulator behavior alongside live signal-quality telemetry. Its cdd564RxTable (indexed 1..4 per demodulator) carries cdd564RxFEC (uncoded/turbo), cdd564RxDemodulation (QPSK/8-PSK/16-QAM), cdd564RxSymbolRate, cdd564RxCodeRate, and alarm thresholds like cdd564RxEbNoAlarmPoint, while runtime status objects such as cdd564RxEbNo, cdd564AGCAlarmMask, and cdd564EbNoAlarmMask report actual signal-to-noise and automatic-gain-control conditions. Event history is tracked in a per-demodulator cdd564EventTable (indexed by cdd564EventDemod and cdd564EventIndex) and long-run signal statistics in cdd564StatisticTable (cdd564StatisticAvgEbNo, cdd564StatisticMinEbNo), while cdd564AccessListTable, cdd564RouteTable, and cdd564IGMPTable manage IP-over-satellite networking features. It depends on the ComtechEFData enterprise MIB tree for its OID placement and is deployed on Comtech EF Data CDD-564 satellite modem/demodulator units in VSAT and satellite backhaul links, where technicians can download the CDD-564 MIB to load into their MIB browser for provisioning and signal-quality monitoring.
IPNetwork Monitor allows you to monitor SNMP objects defined in CDD-564. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Comtech EF Data CDD-564 satellite modem/demodulator
Monitoring Examples
An operator polls cdd564RxEbNo against cdd564RxEbNoAlarmPoint for a given cdd564RxTableIndex to check demodulator signal margin, and reviews cdd564StatisticMinEbNo to see the worst Eb/No recorded over the period; an Eb/No value dropping below the configured alarm point combined with entries appearing in cdd564EventTable would indicate a degrading satellite link or antenna pointing issue.
What Can Be Monitored
- demodulator Eb/No signal level and alarm threshold
- AGC and Eb/No alarm masks
- FEC/demodulation mode and symbol rate configuration
- per-demodulator event log table
- long-term Eb/No statistics (avg/min)
- IP routing and IGMP table state
This MIB depends on
Related MIBs
Imported Objects
From ComtechEFData
| comtechEFData | MODULE-IDENTITY |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Counter32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE |
From SNMPv2-TC
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| INT cdd546RxSpectrumInversion | 1.3.6.1.4.1.6247.25.1.7.1.1.1.10 | INTEGER | read-write | Rx spectrum inversion, where: 0 = Normal 1 = Rx spectrum inverted |
| cdd564 | 1.3.6.1.4.1.6247.25 | Module for CDD-564 Satellite Demod | ||
| cdd5643xDESEncryption | 1.3.6.1.4.1.6247.25.1.1.3 | |||
| STR cdd5643xDESRxKey1 | 1.3.6.1.4.1.6247.25.1.1.3.1.1.2 | DisplayString | read-write | The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters). |
| STR cdd5643xDESRxKey2 | 1.3.6.1.4.1.6247.25.1.1.3.1.1.3 | DisplayString | read-write | The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters). |
| STR cdd5643xDESRxKey3 | 1.3.6.1.4.1.6247.25.1.1.3.1.1.4 | DisplayString | read-write | The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters). |
| STR cdd5643xDESRxKey4 | 1.3.6.1.4.1.6247.25.1.1.3.1.1.5 | DisplayString | read-write | The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters). |
| STR cdd5643xDESRxKey5 | 1.3.6.1.4.1.6247.25.1.1.3.1.1.6 | DisplayString | read-write | The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters). |
| STR cdd5643xDESRxKey6 | 1.3.6.1.4.1.6247.25.1.1.3.1.1.7 | DisplayString | read-write | The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters). |
| STR cdd5643xDESRxKey7 | 1.3.6.1.4.1.6247.25.1.1.3.1.1.8 | DisplayString | read-write | The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters). |
| STR cdd5643xDESRxKey8 | 1.3.6.1.4.1.6247.25.1.1.3.1.1.9 | DisplayString | read-write | The 3xDES receive decrypt key. The key length is 192 bits (24 bytes or 48 characters). |
| cdd5643xDESRxKeyEntry | 1.3.6.1.4.1.6247.25.1.1.3.1.1 | not-accessible | The entry (per demod) of the 3xDES receive decrypt key table. | |
| INT cdd5643xDESRxKeyIndex | 1.3.6.1.4.1.6247.25.1.1.3.1.1.1 | INTEGER | read-only | The index (per demod) of the 3xDES receive decrypt key table. |
| cdd5643xDESRxKeyTable | 1.3.6.1.4.1.6247.25.1.1.3.1 | not-accessible | The table (one row per demod) for triple DES (3xDES) receive decrypt keys. | |
| IP cdd564AccessIPAddress | 1.3.6.1.4.1.6247.25.1.1.1.1.1.2 | IpAddress | read-write | The IP addresses that can access the unit. The value of 0.0.0.0 means not defined. |
| INT cdd564AccessListEnforcement | 1.3.6.1.4.1.6247.25.1.1.1.2 | INTEGER | read-write | Enable or disable enforcement of the the access list. Note: Be sure that you have added the SNMP browser's/manager's IP Address to the access list before enabling access list filtering. Otherwise, the SNMP browser/manager will no longer be able to gain access to the unit. |
| cdd564AccessListEntry | 1.3.6.1.4.1.6247.25.1.1.1.1.1 | not-accessible | The entry for the access list table. | |
| INT cdd564AccessListIndex | 1.3.6.1.4.1.6247.25.1.1.1.1.1.1 | INTEGER | read-only | The index for the access list from 1..4. |
| cdd564AccessLists | 1.3.6.1.4.1.6247.25.1.1.1 | |||
| cdd564AccessListTable | 1.3.6.1.4.1.6247.25.1.1.1.1 | not-accessible | The table for the access list. | |
| INT cdd564AccessSubnetMaskLength | 1.3.6.1.4.1.6247.25.1.1.1.1.1.3 | INTEGER | read-write | The subnet mask length of the IP address for the access list. Subnet mask can be from 8..32. The value of 0 means not defined. |
| cdd564Administration | 1.3.6.1.4.1.6247.25.1.1 | |||
| INT cdd564AGCAlarmMask | 1.3.6.1.4.1.6247.25.1.7.2.1.1.2 | INTEGER | read-write | Rx AGC alarm mask, where: 0 = Unmasked 1 = Masked |
| cdd564AlarmMask | 1.3.6.1.4.1.6247.25.1.7.2 | |||
| cdd564AlarmMaskEntry | 1.3.6.1.4.1.6247.25.1.7.2.1.1 | not-accessible | Description. | |
| INT cdd564AlarmMaskIndex | 1.3.6.1.4.1.6247.25.1.7.2.1.1.1 | INTEGER | read-only | The index for the Demodulator. |
| cdd564AlarmMaskTable | 1.3.6.1.4.1.6247.25.1.7.2.1 | not-accessible | Description. | |
| INT cdd564BootImage | 1.3.6.1.4.1.6247.25.1.5.2.1 | INTEGER | read-write | Specifies which image will be booted: latest - boots the latest image determined by the most recent build date image 1 - boots image from bulk #1 image 2 - boots image from bulk #2 |
| STR cdd564BootInfo | 1.3.6.1.4.1.6247.25.1.5.1.1 | DisplayString | read-only | The version and revision information for the boot application. |
| STR cdd564Bulk1Info | 1.3.6.1.4.1.6247.25.1.5.1.2 | DisplayString | read-only | The version and revision information for the bulk application in image 1. |
| STR cdd564Bulk2Info | 1.3.6.1.4.1.6247.25.1.5.1.3 | DisplayString | read-only | The version and revision information for the bulk application in image 2. |
| cdd564BulkDatabase | 1.3.6.1.4.1.6247.25.1.5.2 | |||
| STR cdd564CircuitID | 1.3.6.1.4.1.6247.25.1.9.6.1.2 | DisplayString | read-write | Sets or queries the user-defined Circuit ID string, which is a fixed length of 24 characters. Valid characters include: Space ( ) * + - , . / 0 thru 9 and A thru Z. |
| cdd564CircuitIDEntry | 1.3.6.1.4.1.6247.25.1.9.6.1 | not-accessible | The entry for the circuit ID table. | |
| INT cdd564CircuitIDIndex | 1.3.6.1.4.1.6247.25.1.9.6.1.1 | INTEGER | read-only | The index for the Demodulator. |
| cdd564CircuitIDTable | 1.3.6.1.4.1.6247.25.1.9.6 | not-accessible | The table for Circuit IDs (Per Demod). | |
| INT cdd564ClearAllStoredEvents | 1.3.6.1.4.1.6247.25.1.8.4.2 | INTEGER | read-write | This is a SET command to clear the event log for one of the four demods (1 - 4). |
| INT cdd564ClearAllStoredStatistics | 1.3.6.1.4.1.6247.25.1.8.5.3 | INTEGER | read-write | This is a SET command to clear the statistics log for one of the four demods (1 - 4). |
| cdd564Compliance | 1.3.6.1.4.1.6247.25.3.2.1 | CDD-564 Compliance. | ||
| cdd564Compliances | 1.3.6.1.4.1.6247.25.3.2 | |||
| cdd564Config | 1.3.6.1.4.1.6247.25.1.7 | |||
| cdd564Conformance | 1.3.6.1.4.1.6247.25.3 | |||
| cdd564DemodulatorInterfaces | 1.3.6.1.4.1.6247.25.1.2.2 | |||
| C32 cdd564DroppedPacketsBadBufferLength | 1.3.6.1.4.1.6247.25.1.6.1.5.3 | Counter32 | read-only | The total number of packets dropped by the router because of a bad packet buffer length. |
| C32 cdd564DroppedPacketsBadIPHeader | 1.3.6.1.4.1.6247.25.1.6.1.5.2 | Counter32 | read-only | The total number of packets dropped by the router because of a bad checksum in the IP header. |
| C32 cdd564DroppedPacketsBadIPVersion | 1.3.6.1.4.1.6247.25.1.6.1.5.4 | Counter32 | read-only | The total number of packets dropped by the router because of the packet is not IPv4. Note: IPv6 packets are not support by the router. |
| C32 cdd564DroppedPacketsFiltered | 1.3.6.1.4.1.6247.25.1.6.1.5.10 | Counter32 | read-only | The total number of packets dropped by the router for the following reasons: 1. Boot 2. Flow Descriptor 3. Unknown Reason Code 4. Flow Correlator 5. Management Path 6. Ping 7. Access Control 8. Vipersat Multicommand 9. Vipersat Unicommand 10. Codeload 11. Multicast 12. Bad Packet 13. Route 14. Bad Header Len 15. Bad Data Ptr 16. MAC Split Err 17. L3Type Err 18. Local Destination 19. ICMP Filter 20. Port Err 21. Per port route rule |
| C32 cdd564DroppedPacketsFilteredMulticast | 1.3.6.1.4.1.6247.25.1.6.1.5.8 | Counter32 | read-only | The total number of multicast packets dropped by the router because the multicast address is not being forwarded. |
| C32 cdd564DroppedPacketsMulticastDisableGroup | 1.3.6.1.4.1.6247.25.1.6.1.5.9 | Counter32 | read-only | The total number of multicast packets dropped by the router because the multicast group is not being forwarded. |
| C32 cdd564DroppedPacketsNoARPEntry | 1.3.6.1.4.1.6247.25.1.6.1.5.7 | Counter32 | read-only | The total number of packets dropped by the router because the ARP table did not have an ARP entry for the packet's next hop. |
| C32 cdd564DroppedPacketsNoRoute | 1.3.6.1.4.1.6247.25.1.6.1.5.6 | Counter32 | read-only | The total number of packets dropped by the router because the packet did not match any route in the route table and could not be forwarded. |
| C32 cdd564DroppedPacketsRouterQueueFull | 1.3.6.1.4.1.6247.25.1.6.1.5.11 | Counter32 | read-only | The total number of packets dropped by the router because the router queue is full. |
| C32 cdd564DroppedPacketsTTLExpired | 1.3.6.1.4.1.6247.25.1.6.1.5.5 | Counter32 | read-only | The total number of packets dropped by the router because the TTL (time to live) in the IP header had expired (i.e. reached zero). |
| INT cdd564EbNoAlarmMask | 1.3.6.1.4.1.6247.25.1.7.2.1.1.3 | INTEGER | read-write | Eb/No alarm mask, where: 0 = Unmasked 1 = Masked |
| INT cdd564EthernetClearCounters | 1.3.6.1.4.1.6247.25.1.6.2.3 | INTEGER | read-write | Reset all ethernet transmit & receive counters. |
| cdd564EthernetInterface | 1.3.6.1.4.1.6247.25.1.2.1 | |||
| cdd564EthernetRxStats | 1.3.6.1.4.1.6247.25.1.6.2.2 | |||
| INT cdd564EthernetSpeed | 1.3.6.1.4.1.6247.25.1.2.1.2 | INTEGER | read-write | The speed of the Ethernet interface. |
| cdd564EthernetStatistics | 1.3.6.1.4.1.6247.25.1.6.2 | |||
| cdd564EthernetTxStats | 1.3.6.1.4.1.6247.25.1.6.2.1 | |||
| C32 cdd564EtherRxAllignmentErrors | 1.3.6.1.4.1.6247.25.1.6.2.2.3 | Counter32 | read-only | The number of frames that are both misaligned [in other words, CRS de-asserts on a non-octet boundary] and contain a CRC error. |
| C32 cdd564EtherRxCollisionDetectErrors | 1.3.6.1.4.1.6247.25.1.6.2.2.6 | Counter32 | read-only | The number of frames that encountered collision during reception. This is always zero. |
| C32 cdd564EtherRxCRCErrorFrames | 1.3.6.1.4.1.6247.25.1.6.2.2.2 | Counter32 | read-only | The number of aligned frames discarded due to CRC Errors. |
| C32 cdd564EtherRxFIFOOverrunErrors | 1.3.6.1.4.1.6247.25.1.6.2.2.5 | Counter32 | read-only | The number of frames known to be lost because the internal receive FIFO overflowed [also known as receive overrun]. This can occur if the device is unable to get necessary PCI bandwidth. If the overflow condition persists for more than one frame, the frames that follow the first can also be lost. A frame that was counted as an overrun will not be counted in other error counters like (short frames, misaligned, CRC error). |
| C32 cdd564EtherRxFlowControlPauseFrames | 1.3.6.1.4.1.6247.25.1.6.2.2.8 | Counter32 | read-only | The number of flow control frames received by the device. This count includes both XOFF and XON frames received. |
| C32 cdd564EtherRxGoodFrames | 1.3.6.1.4.1.6247.25.1.6.2.2.1 | Counter32 | read-only | The number of frames properly received from the link. It is updated only after actual reception from the link is completed and all data bytes are stored in memory. |
| C32 cdd564EtherRxResourceErrors | 1.3.6.1.4.1.6247.25.1.6.2.2.4 | Counter32 | read-only | The number of good frames discarded due to unavailable resources. |
| C32 cdd564EtherRxShortFrames | 1.3.6.1.4.1.6247.25.1.6.2.2.7 | Counter32 | read-only | The number of received frames that are shorter than the minimum frame length. |
| C32 cdd564EtherTxDeferred | 1.3.6.1.4.1.6247.25.1.6.2.1.6 | Counter32 | read-only | The number of frames deferred before transmission due to activity on the link. |
| C32 cdd564EtherTxDMAUnderrun | 1.3.6.1.4.1.6247.25.1.6.2.1.4 | Counter32 | read-only | The number of frames that were either NOT transmitted or retransmitted due to Transmit DMA underrun. Underruns occur due to lack of PCI bandwidth resulting in the internal transmit FIFO running dry during the transmission of a frame. |
| C32 cdd564EtherTxFlowControlPauseFrames | 1.3.6.1.4.1.6247.25.1.6.2.1.10 | Counter32 | read-only | The number of flow control frames transmitted by the device. This count includes both the XOFF and XON frames transmitted by the device. |
| C32 cdd564EtherTxGoodFrames | 1.3.6.1.4.1.6247.25.1.6.2.1.1 | Counter32 | read-only | The number of transmitted good frames from the Ethernet interface. |
| C32 cdd564EtherTxLateCollisions | 1.3.6.1.4.1.6247.25.1.6.2.1.3 | Counter32 | read-only | The number of frames that were NOT transmitted because they encountered collision outside the normal collision window. |
| C32 cdd564EtherTxLostCarrierSense | 1.3.6.1.4.1.6247.25.1.6.2.1.5 | Counter32 | read-only | The number of frames transmitted by the device despite the fact that it detected the de-assertion of Transmit Lost Carrier Sense (CRS) during the transmission. |
| C32 cdd564EtherTxMaxCollisions | 1.3.6.1.4.1.6247.25.1.6.2.1.2 | Counter32 | read-only | The number of frames that were NOT transmitted because they encountered the maximum configured collisions. This counter should only increment when network is heavily saturated with traffic. |
| C32 cdd564EtherTxMultipleCollisions | 1.3.6.1.4.1.6247.25.1.6.2.1.8 | Counter32 | read-only | The number of transmitted frames that encountered more than 1 collision. |
| C32 cdd564EtherTxSingleCollisions | 1.3.6.1.4.1.6247.25.1.6.2.1.7 | Counter32 | read-only | The number of transmitted frames that encountered only 1 collision. |
| C32 cdd564EtherTxTotalCollisions | 1.3.6.1.4.1.6247.25.1.6.2.1.9 | Counter32 | read-only | The total number of collisions that were encountered while attempting to transmit. This count includes late collisions and collisions from frames that encountered maximum collisions. |
| INT cdd564EventDemod | 1.3.6.1.4.1.6247.25.1.8.4.1.1.1 | INTEGER | read-only | The demodulator index for which event log is being returned. |
| STR cdd564EventDescription | 1.3.6.1.4.1.6247.25.1.8.4.1.1.3 | DisplayString | read-only | Event description string with the following format seprated by commas: 1. Date in form dd/mm/yy, where: dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) 2. Time in form hh:mm:ss, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) 3. Event Type in form xxxxx, where xxxxx is Clear = fault cleared Fault = fault occurred Info = information 4. Texual Description of Event |
| INT cdd564EventIndex | 1.3.6.1.4.1.6247.25.1.8.4.1.1.2 | INTEGER | read-only | The index for a demod's stored events table. |
| INT cdd564FeatureIndex | 1.3.6.1.4.1.6247.25.1.1.2.5.1.1 | INTEGER | read-only | The index for the FAST Feature (per demod) table. |
| cdd564Features | 1.3.6.1.4.1.6247.25.1.1.2 | |||
| cdd564FeaturesEntry | 1.3.6.1.4.1.6247.25.1.1.2.5.1 | not-accessible | The entry for the FAST Feature (per demod) table. | |
| cdd564FeaturesTable | 1.3.6.1.4.1.6247.25.1.1.2.5 | not-accessible | The table (per demodulator) of FAST Features. | |
| INT cdd564ForwardMulticasts | 1.3.6.1.4.1.6247.25.1.1.2.4 | INTEGER | read-write | Enable or disable forwarding all multicasts received from the Satellite interface to the Ethernet interface. |
| STR cdd564FPGARx1Info | 1.3.6.1.4.1.6247.25.1.5.1.4 | DisplayString | read-only | The version and revision information for the Rx FPGA in image 1. |
| STR cdd564FPGARx2Info | 1.3.6.1.4.1.6247.25.1.5.1.5 | DisplayString | read-only | The version and revision information for the Rx FPGA in image 2. |
| cdd564Groups | 1.3.6.1.4.1.6247.25.3.1 | |||
| INT cdd564HDLCAddress1 | 1.3.6.1.4.1.6247.25.1.2.2.3.1.3 | INTEGER | read-write | The HDLC address #1 for the satellite interface. The valid values are: 1. Small network, 1 to 254 (0x1 - 0xFE). 2. Large network, 1 to 32766 (0x1 - 0x0x7FFE). 3. Point to point, not used. 4. EasyConnect, not used. HDLC address can not have 0x00 or 0xFF in least significant byte, i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses. Deletion: To delete the HDLC address, set it to zero. |
| INT cdd564HDLCAddress2 | 1.3.6.1.4.1.6247.25.1.2.2.3.1.4 | INTEGER | read-write | The HDLC address #2 for the satellite interface. The valid values are: 1. Small network, 1 to 254 (0x1 - 0xFE). 2. Large network, 1 to 32766 (0x1 - 0x0x7FFE). 3. Point to point, not used. 4. EasyConnect, not used. HDLC address can not have 0x00 or 0xFF in least significant byte, i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses. Deletion: To delete the HDLC address, set it to zero. |
| INT cdd564HDLCAddress3 | 1.3.6.1.4.1.6247.25.1.2.2.3.1.5 | INTEGER | read-write | The HDLC address #3 for the satellite interface. The valid values are: 1. Small network, 1 to 254 (0x1 - 0xFE). 2. Large network, 1 to 32766 (0x1 - 0x0x7FFE). 3. Point to point, not used. 4. EasyConnect, not used. HDLC address can not have 0x00 or 0xFF in least significant byte, i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses. Deletion: To delete the HDLC address, set it to zero. |
| INT cdd564HDLCAddress4 | 1.3.6.1.4.1.6247.25.1.2.2.3.1.6 | INTEGER | read-write | The HDLC address #4 for the satellite interface. The valid values are: 1. Small network, 1 to 254 (0x1 - 0xFE). 2. Large network, 1 to 32766 (0x1 - 0x0x7FFE). 3. Point to point, not used. 4. EasyConnect, not used. HDLC address can not have 0x00 or 0xFF in least significant byte, i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses. Deletion: To delete the HDLC address, set it to zero. |
| cdd564HDLCAddressEntry | 1.3.6.1.4.1.6247.25.1.2.2.3.1 | not-accessible | The entry of the HDLC Address table. | |
| INT cdd564HDLCAddressIndex | 1.3.6.1.4.1.6247.25.1.2.2.3.1.1 | INTEGER | read-only | The Demod number corresponding to 1 of 4 demodulators. |
| INT cdd564HDLCAddressMode | 1.3.6.1.4.1.6247.25.1.2.2.2 | INTEGER | read-only | The size of HDLC address used for sending packets over satellite interface can range from 0 - 2 bytes. The satellite interface will operate in one of the following modes: 1.Small Network mode - The packet uses a 1 byte HDLC address. The valid values are from 1 to 254 (0x1 - 0xFE). 2.Large Network mode - The packet uses a 2 byte HDLC address. The valid values are from 1 to 32766 (0x1 - 0x7FFE). 3. Point To Point mode - The packet does not use a HDLC address. An HDLC address cannot have 0x00 or 0xFF in least Significant Byte. i.e., 0x400 or 0x6ff or 0x11ff are NOT valid HDLC addresses. |
| cdd564HDLCAddressTable | 1.3.6.1.4.1.6247.25.1.2.2.3 | not-accessible | The table for the Demodulator HDLC Addresses. | |
| INT cdd564HeaderCompression | 1.3.6.1.4.1.6247.25.1.1.2.5.1.2 | INTEGER | read-write | Availability of header compression is based on FAST features Note: To use header compression, it must be FAST available and enabled on both the transmit and receive sides. |
| INT cdd564IGMP | 1.3.6.1.4.1.6247.25.1.1.2.3 | INTEGER | read-write | Enable or disable the Internet Group Management Protocol (IGMP). |
| INT cdd564IGMPClientState | 1.3.6.1.4.1.6247.25.1.4.1.3.1.3 | INTEGER | read-only | The state for the multicast group. |
| cdd564IGMPConfig | 1.3.6.1.4.1.6247.25.1.4.1 | |||
| cdd564IGMPEntry | 1.3.6.1.4.1.6247.25.1.4.1.3.1 | not-accessible | The entry for the IGMP group table. | |
| IP cdd564IGMPGroupIPAddress | 1.3.6.1.4.1.6247.25.1.4.1.3.1.5 | IpAddress | read-only | The multicast group address. |
| INT cdd564IGMPIndex | 1.3.6.1.4.1.6247.25.1.4.1.3.1.1 | INTEGER | read-only | The index for the IGMP group table. |
| INT cdd564IGMPMaxMissBeforeLeavingGroup | 1.3.6.1.4.1.6247.25.1.4.1.1.3 | INTEGER | read-write | The maximum number of missed responses before leaving the IGMP group. |
| INT cdd564IGMPMaxResponseTime | 1.3.6.1.4.1.6247.25.1.4.1.1.2 | INTEGER | read-write | The IGMP maximum response time, in seconds. |
| C32 cdd564IGMPPacketsReceived | 1.3.6.1.4.1.6247.25.1.6.1.4.1 | Counter32 | read-only | The total number of IGMP packets received by the endstation. |
| INT cdd564IGMPQueryPeriod | 1.3.6.1.4.1.6247.25.1.4.1.1.1 | INTEGER | read-write | The IGMP query period, in seconds. |
| cdd564IGMPServer | 1.3.6.1.4.1.6247.25.1.4.1.1 | |||
| INT cdd564IGMPSrc | 1.3.6.1.4.1.6247.25.1.4.1.3.1.4 | INTEGER | read-only | The interface from which the multicast group was received. |
| cdd564IGMPTable | 1.3.6.1.4.1.6247.25.1.4.1.3 | not-accessible | The table for IGMP groups. | |
| INT cdd564IGMPTTL | 1.3.6.1.4.1.6247.25.1.4.1.3.1.2 | INTEGER | read-only | The TTL for the multicast group. |
| cdd564Interfaces | 1.3.6.1.4.1.6247.25.1.2 | |||
| INT cdd564InternalReferenceAdjust | 1.3.6.1.4.1.6247.25.1.7.3.2 | INTEGER | read-write | Internal Reference Adjust, from -999 to +999. Units = KHz |
| IP cdd564IPAddress | 1.3.6.1.4.1.6247.25.1.2.1.3 | IpAddress | read-write | The IP address assigned to the Ethernet interface. |
| C32 cdd564IPOptionPacketsReceived | 1.3.6.1.4.1.6247.25.1.6.1.4.2 | Counter32 | read-only | The total number of packets received with IP Options in the IP header. |
| INT cdd564IPRoutingClearCounters | 1.3.6.1.4.1.6247.25.1.6.1.6 | INTEGER | read-write | This is a SET command to clear the IP routing counters. |
| cdd564IPRoutingDropped | 1.3.6.1.4.1.6247.25.1.6.1.5 | |||
| cdd564IPRoutingEndstation | 1.3.6.1.4.1.6247.25.1.6.1.3 | |||
| cdd564IPRoutingEthernet | 1.3.6.1.4.1.6247.25.1.6.1.1 | |||
| cdd564IPRoutingMisc | 1.3.6.1.4.1.6247.25.1.6.1.4 | |||
| cdd564IPRoutingSatellite | 1.3.6.1.4.1.6247.25.1.6.1.2 | |||
| cdd564IPRoutingStatistics | 1.3.6.1.4.1.6247.25.1.6.1 | |||
| cdd564LNB | 1.3.6.1.4.1.6247.25.1.7.4 | |||
| INT cdd564LNB10MHzReference | 1.3.6.1.4.1.6247.25.1.7.4.1.1.3 | INTEGER | read-write | LNB 10MHz frequency reference, where: 0 = Disable LNB 10MHz reference 1 = Enable LNB 10MHz reference |
| INT cdd564LNBAlarm | 1.3.6.1.4.1.6247.25.1.8.3.1.1.2 | INTEGER | read-only | LNB alarms Value Description of status parameter 0 No LNB faults 7 LNB current 9 LNB voltage |
| INT cdd564LNBAlarmMask | 1.3.6.1.4.1.6247.25.1.7.2.1.1.5 | INTEGER | read-write | LNB alarm mask, where: 0 = Unmasked 1 = Masked |
| NTF cdd564LNBAlarmNotification | 1.3.6.1.4.1.6247.25.2.0.3 | Trap for LNB alarms. | ||
| INT cdd564LNBCurrent | 1.3.6.1.4.1.6247.25.1.8.3.1.1.3 | INTEGER | read-only | Indicates the value of the LNB current, between 0 and 999 mA. |
| INT cdd564LNBDCPower | 1.3.6.1.4.1.6247.25.1.7.4.1.1.2 | INTEGER | read-write | LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage |
| cdd564LNBEntry | 1.3.6.1.4.1.6247.25.1.7.4.1.1 | not-accessible | The entry for the LNBs table. | |
| INT cdd564LNBHighCurrentLimit | 1.3.6.1.4.1.6247.25.1.7.4.1.1.5 | INTEGER | read-write | LNB upper alarm limit for current, between 50 and 600 mA. |
| INT cdd564LNBIndex | 1.3.6.1.4.1.6247.25.1.7.4.1.1.1 | INTEGER | read-only | The index for the LNB.. |
| INT cdd564LNBLOFrequency | 1.3.6.1.4.1.6247.25.1.7.4.1.1.6 | INTEGER | read-write | LNB receieve LO frequency, in the range of 3000 to 65000 MHz. Setting a 0 disables the feature. Terminal Frequency = LNB_LO +/- Rx_Frequency (depending on High/Low Mix) |
| INT cdd564LNBLOMix | 1.3.6.1.4.1.6247.25.1.7.4.1.1.7 | INTEGER | read-write | LO frequency mix, where: 0 = Low-side mix 1 = High-side mix |
| cdd564LNBMonitor | 1.3.6.1.4.1.6247.25.1.8.3 | |||
| cdd564LNBMonitorEntry | 1.3.6.1.4.1.6247.25.1.8.3.1.1 | not-accessible | The entry for the LNBs monitoring table. | |
| INT cdd564LNBMonitorIndex | 1.3.6.1.4.1.6247.25.1.8.3.1.1.1 | INTEGER | read-only | The index for the LNBs monitoring table. |
| cdd564LNBMonitorTable | 1.3.6.1.4.1.6247.25.1.8.3.1 | not-accessible | The table for monitoring LNBs. | |
| cdd564LNBTable | 1.3.6.1.4.1.6247.25.1.7.4.1 | not-accessible | The table for LNBs. | |
| INT cdd564LNBTerminalRxFreq | 1.3.6.1.4.1.6247.25.1.8.3.1.1.5 | INTEGER | read-only | Terminal Rx frequency = LNB LO +/- Rx_Frequency (depending on LO mix) Units = 100 Hz Resolution = 100 Hz Returns 0 if LNB_LO is zero. |
| INT cdd564LNBVoltage | 1.3.6.1.4.1.6247.25.1.8.3.1.1.4 | INTEGER | read-only | Indicates the value of the LNB voltage, between 0 and 30 volts. Units = 0.1 volts If not available, response is 0. |
| STR cdd564MACAddress | 1.3.6.1.4.1.6247.25.1.2.1.1 | DisplayString | read-only | The MAC address assigned to the Ethernet interface. |
| cdd564Maint | 1.3.6.1.4.1.6247.25.1.5 | |||
| INT cdd564ModelNumber | 1.3.6.1.4.1.6247.25.1.8.1.3 | INTEGER | read-only | Unit's model number. |
| cdd564Monitor | 1.3.6.1.4.1.6247.25.1.8 | |||
| cdd564Notifications | 1.3.6.1.4.1.6247.25.2 | |||
| cdd564NotificationsGroup | 1.3.6.1.4.1.6247.25.3.1.2 | CDD-564 Trap Group. | ||
| cdd564NotificationsPrefix | 1.3.6.1.4.1.6247.25.2.0 | |||
| cdd564Objects | 1.3.6.1.4.1.6247.25.1 | |||
| cdd564ObjectsGroup | 1.3.6.1.4.1.6247.25.3.1.1 | CDD-564 Objects Group. | ||
| cdd564ParamDatabase | 1.3.6.1.4.1.6247.25.1.5.3 | |||
| INT cdd564ParamImage | 1.3.6.1.4.1.6247.25.1.5.3.1 | INTEGER | read-write | Specifies if configuration should be read from: paramFile - parameter file stored in flash factoryDefaults - the factory defaults |
| INT cdd564PingReply | 1.3.6.1.4.1.6247.25.1.1.2.1 | INTEGER | read-write | Enable or disable ping reply from unit. |
| cdd564Protocols | 1.3.6.1.4.1.6247.25.1.4 | |||
| INT cdd564Reboot | 1.3.6.1.4.1.6247.25.1.5.4.1 | INTEGER | read-write | The is a SET command that will reboot the unit. *** Important *** The command will reboot the unit without saving the configuration to the parameter file in flash. |
| cdd564RebootUnit | 1.3.6.1.4.1.6247.25.1.5.4 | |||
| cdd564Reference | 1.3.6.1.4.1.6247.25.1.7.3 | |||
| INT cdd564ReferenceFrequency | 1.3.6.1.4.1.6247.25.1.7.3.1 | INTEGER | read-write | External reference frequency, where: 0 = Internal 10 MHz |
| INT cdd564ReloadParamFromFlash | 1.3.6.1.4.1.6247.25.1.5.3.3 | INTEGER | read-write | This is a SET command to reload the configuration from the parameter file in flash. |
| INT cdd564RestoreFactoryDefaults | 1.3.6.1.4.1.6247.25.1.5.3.4 | INTEGER | read-write | This is a SET command that restore the configuration to the factory defaults. *** Imporant *** Setting this command ERASES the parameter file in flash. |
| IP cdd564RouteDestAddress | 1.3.6.1.4.1.6247.25.1.3.1.1.3 | IpAddress | read-write | The destination IP address for the route. |
| INT cdd564RouteDestMaskLen | 1.3.6.1.4.1.6247.25.1.3.1.1.4 | INTEGER | read-write | The subnet mask lenght for the destination IP address. |
| cdd564RouteEntry | 1.3.6.1.4.1.6247.25.1.3.1.1 | not-accessible | The entry for the the route table. | |
| INT cdd564RouteIndex | 1.3.6.1.4.1.6247.25.1.3.1.1.1 | INTEGER | read-write | The index for the route table. |
| INT cdd564RouteInterface | 1.3.6.1.4.1.6247.25.1.3.1.1.7 | INTEGER | read-write | Routes are destined to the Ethernet interface. |
| INT cdd564RouteMulticast | 1.3.6.1.4.1.6247.25.1.3.1.1.6 | INTEGER | read-write | If the route is a multicast, packets can be: 1. forwarded 2. filtered If the route is unicast, the field is not applicable. |
| STR cdd564RouteName | 1.3.6.1.4.1.6247.25.1.3.1.1.2 | DisplayString | read-write | The name of the route. All routes must be named. |
| IP cdd564RouteNextHopAddress | 1.3.6.1.4.1.6247.25.1.3.1.1.5 | IpAddress | read-write | The next hop IP address for the route. |
| INT cdd564RouteRowStatus | 1.3.6.1.4.1.6247.25.1.3.1.1.8 | INTEGER | read-write | This value is used for status of route: active(1) - The route is active. These values are used to create or delete route: createAndGo(4) - The route is to be created. destroy(6) - The route to be deleted. |
| cdd564Routes | 1.3.6.1.4.1.6247.25.1.3 | |||
| cdd564RouteTable | 1.3.6.1.4.1.6247.25.1.3.1 | not-accessible | The route table used in Router mode. | |
| STR cdd564RTCDate | 1.3.6.1.4.1.6247.25.1.9.4 | DisplayString | read-write | A date in the form dd/mm/yy, where dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) |
| STR cdd564RTCTime | 1.3.6.1.4.1.6247.25.1.9.5 | DisplayString | read-write | A time in the form hh:mm:ss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) |
| cdd564Rx | 1.3.6.1.4.1.6247.25.1.7.1 | |||
| C32 cdd564RxAbortOctetErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.7 | Counter32 | read-only | The count of aborted frames and octet error frames. Aborted frame: A frame is aborted when the frame is not complete and is terminated prematurely with the Abort signal, which is 8 consecutive '1's. Octet error: A frames that was not on a byte boudary or on a multiple of 8-bit boundary. |
| INT cdd564RxAcquisitionSweepWidth | 1.3.6.1.4.1.6247.25.1.7.1.1.1.7 | INTEGER | read-write | Rx +/- acquisition sweep range of demodulator, in KHz, ranging from: +/- 1 to +/- 32 KHz (rates = 625 ksym/second) |
| INT cdd564RxAlarm | 1.3.6.1.4.1.6247.25.1.8.2.1.1.2 | INTEGER | read-only | Modem RX Traffic Faults Value Description of status parameter 0 Rx Traffic OK 1 Demodulator unlocked 3 AGC Alarm - signal out of range 10 Buffer underflow 11 Buffer overflow 13 Eb/No alarm 15 AIS detected on incoming data |
| NTF cdd564RxAlarmNotification | 1.3.6.1.4.1.6247.25.2.0.2 | Trap for Rx alarms. | ||
| C32 cdd564RxBadHDLCAddressErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.5 | Counter32 | read-only | The count of received frames that did not match any of the Rx HDLC addresses. |
| INT cdd564RxBufferSize | 1.3.6.1.4.1.6247.25.1.7.1.1.1.9 | INTEGER | read-write | Rx buffer size, where: 0 = Buffer disabled (Clock mode = Rx satellite) |
| INT cdd564RxCodeRate | 1.3.6.1.4.1.6247.25.1.7.1.1.1.4 | INTEGER | read-write | Rx code rate, where 4 = Rate 3/4 5 = Rate 7/8 6 = Rate 0.95 7 = Rate 1/1 (Uncoded) |
| C32 cdd564RxCRCErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.14 | Counter32 | read-only | The number of frames with a CRC error detected by the Rx FPGA. |
| INT cdd564RxDataInversion | 1.3.6.1.4.1.6247.25.1.7.1.1.1.11 | INTEGER | read-write | Invert receive data, where: 0 = Normal 1 = Inverted |
| INT cdd564RxDataRate | 1.3.6.1.4.1.6247.25.1.7.1.1.1.5 | INTEGER | read-write | Rx data rate in bps (Varies based on chart below.) Units = bps Resolution = 1 bps FEC Type Modulation Code Rate Data Rate High Rate -------- ----------- ---------- --------------------- --------- Turbo QPSK Rate 3/4 16.0 Kbps to 4.5 Mbps N/A Turbo QPSK Rate 7/8 16.0 Kbps to 5.0 Mbps 5.25 Mbps Turbo QPSK Rate 0.95 16.0 Kbps to 5.0 Mbps 5.667 Mbps Turbo 8-PSK Rate 3/4 16.0 Kbps to 5.0 Mbps 6.75 Mbps Turbo 8-PSK Rate 7/8 16.0 Kbps to 5.0 Mbps 7.875 Mbps Turbo 8-PSK Rate 0.95 16.0 Kbps to 5.0 Mbps 8.5 Mbps Turbo 16-QAM Rate 3/4 16.0 Kbps to 5.0 Mbps 9.0 Mbps Turbo 16-QAM Rate 7/8 16.8 Kbps to 5.0 Mbps 9.98 Mbps |
| INT cdd564RxDemodulation | 1.3.6.1.4.1.6247.25.1.7.1.1.1.3 | INTEGER | read-write | Rx demodulation type, where: 1 = QPSK 3 = 8-PSK 4 = 16-QAM |
| INT cdd564RxDescrambling | 1.3.6.1.4.1.6247.25.1.7.1.1.1.8 | INTEGER | read-write | Rx descrambler state, where: 0 = Off 1 = On (default descrambler type) 2 = On - IESS-315 (Turbo only) |
| INT cdd564RxEbNo | 1.3.6.1.4.1.6247.25.1.8.2.1.1.3 | INTEGER | read-only | Unit returns the value of Eb/No, between 0 and 16 db. Units = 0.1 dB Resolution 0.1 dB Returns 999 if demod is unlocked. For values greater than 16 dB, the reply will be 160. |
| INT cdd564RxEbNoAlarmPoint | 1.3.6.1.4.1.6247.25.1.7.1.1.1.12 | INTEGER | read-write | Rx Eb/No alarm point in 0.1 dB, with a range between 0.1 dB and 16 dB. Units = 0.1 dB Resolution = 0.1 dB |
| cdd564RxEntry | 1.3.6.1.4.1.6247.25.1.7.1.1.1 | not-accessible | The entry for the Demodulator table. | |
| INT cdd564RxFEC | 1.3.6.1.4.1.6247.25.1.7.1.1.1.2 | INTEGER | read-write | Rx FEC type where: 0 = Uncoded 6 = Turbo |
| INT cdd564RxFreqOffset | 1.3.6.1.4.1.6247.25.1.8.2.1.1.5 | INTEGER | read-only | Unit returns the value of the measured frequency offset of the carrier being demodulated in Hz. Units = Hz. Resolution 100 Hz. Range = -200,000 Hz to 0 Hz and 0 Hz to 200,000 Hz. |
| INT cdd564RxFrequency | 1.3.6.1.4.1.6247.25.1.7.1.1.1.6 | INTEGER | read-write | Rx frequency for L-Band and IF-Band modes. L-Band is 950 MHz to 1950 MHz. IF-Band is 50 MHz to 90 MHz and 100 MHz to 180 MHz. Units = Hz. Resolution = 100 Hz. |
| C32 cdd564RxGoodFrames | 1.3.6.1.4.1.6247.25.1.6.3.1.1.2 | Counter32 | read-only | The total number of good frames received over satellite interface. |
| C32 cdd564RxHDLCCRCErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.9 | Counter32 | read-only | The HDLC CRC is the first stage of the CRC check, before 3xDES and paylod Decompression. It indicates any errors due to the satellite link only. |
| C32 cdd564RxHeaderBytes | 1.3.6.1.4.1.6247.25.1.6.3.1.1.3 | Counter32 | read-only | The count of HDLC header bytes received over the satellite interface. HDLC header = Control + HDLC address + Flow ID + CRC |
| C32 cdd564RxHeaderDecompressionErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.12 | Counter32 | read-only | The number of frames with a compressed IP header that encountered an error in decompressing (rebuilding) the full IP header. |
| C32 cdd564RxInvalidFlowIDErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.10 | Counter32 | read-only | The number of frames received where the flow ID did not match to a valid flow descriptor. |
| C32 cdd564RxMemoryAlignmentErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.13 | Counter32 | read-only | The number of frames which were incorrectly transferred (frame too small) from the Rx FPGA. |
| cdd564RxMonitor | 1.3.6.1.4.1.6247.25.1.8.2 | |||
| cdd564RxMonitorEntry | 1.3.6.1.4.1.6247.25.1.8.2.1.1 | not-accessible | The entry for the demoduator monitor table. | |
| INT cdd564RxMonitorIndex | 1.3.6.1.4.1.6247.25.1.8.2.1.1.1 | INTEGER | read-only | The index for the demodulator monitor table. |
| cdd564RxMonitorTable | 1.3.6.1.4.1.6247.25.1.8.2.1 | not-accessible | The table for monitoring demodulators. | |
| C32 cdd564RxOverrunErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.8 | Counter32 | read-only | The count of received frames that exceeded the maximum frame length of 2K bytes or overflowed the buffer which stores complete HDLC frames. |
| C32 cdd564RxPayloadBytes | 1.3.6.1.4.1.6247.25.1.6.3.1.1.4 | Counter32 | read-only | The count of payload bytes that were received over satellite interface, excluding any frame overhead. |
| C32 cdd564RxPktProcCRCErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.6 | Counter32 | read-only | The Packet Processor CRC check is the second CRC check performed after the HDLC CRC check. It is the checksum calculated after Decryption and Payload Decompression. Failures due to 3xDES and Payload Comp are detected at this level. |
| INT cdd564RxRecenterBuffer | 1.3.6.1.4.1.6247.25.1.7.1.1.1.13 | INTEGER | read-write | This is a SET command that recenters the receive Plesiochronous/Doppler buffer. |
| C32 cdd564RxSARReassembleErrors | 1.3.6.1.4.1.6247.25.1.6.3.1.1.11 | Counter32 | read-only | The number of frames corresponding to a packet which had undergone segmentation and encountered an error in reassembly. |
| INT cdd564RxSignalLevel | 1.3.6.1.4.1.6247.25.1.8.2.1.1.4 | INTEGER | read-only | Unit returns the value of the Rx signal level, in dBm, between -20 and -99 dBm, Returns -100 if signal is less than -99dBm. Returns -19 if signal is greater than -20dBm. |
| INT cdd564RxStatsIndex | 1.3.6.1.4.1.6247.25.1.6.3.1.1.1 | INTEGER | read-only | The Rx index for the satellite interface, where index can be from 1 to 4. |
| INT cdd564RxSymbolRate | 1.3.6.1.4.1.6247.25.1.7.1.1.1.14 | INTEGER | read-only | Rx symbol rate in symbols per second (sym) Units = sym Resolution = 1 sym |
| cdd564RxTable | 1.3.6.1.4.1.6247.25.1.7.1.1 | not-accessible | The table of Demodulators. | |
| INT cdd564RxTableIndex | 1.3.6.1.4.1.6247.25.1.7.1.1.1.1 | INTEGER | read-only | The index for the Rx table, where index can be from 1 to 4. |
| INT cdd564SatelliteClearCounters | 1.3.6.1.4.1.6247.25.1.6.3.2 | INTEGER | read-write | This is a SET command for clearing all the Satellite statistic counters. |
| cdd564SatelliteRxStatsEntry | 1.3.6.1.4.1.6247.25.1.6.3.1.1 | not-accessible | The entry for the Satellite interface statistics table. | |
| cdd564SatelliteRxStatsTable | 1.3.6.1.4.1.6247.25.1.6.3.1 | not-accessible | The table for Satellite interface statistics. | |
| cdd564SatelliteStatistics | 1.3.6.1.4.1.6247.25.1.6.3 | |||
| INT cdd564SaveParamToFlash | 1.3.6.1.4.1.6247.25.1.5.3.2 | INTEGER | read-write | This is a SET command to save the configuration to the parameter file in flash. |
| STR cdd564SerialNumber | 1.3.6.1.4.1.6247.25.1.8.1.1 | DisplayString | read-only | Unit's 9-digit serial number. |
| cdd564SMTP | 1.3.6.1.4.1.6247.25.1.1.4 | |||
| STR cdd564SMTPDomain | 1.3.6.1.4.1.6247.25.1.1.4.2 | DisplayString | read-write | The SMTP Domain for sending problem reports. This value should be comtechefdata.com. |
| IP cdd564SMTPServerIPAddress | 1.3.6.1.4.1.6247.25.1.1.4.1 | IpAddress | read-write | The IP address of the SMTP server for sending problem reports. This IP adderess should correspond to a local Mail server. |
| STR cdd564SMTPUserName | 1.3.6.1.4.1.6247.25.1.1.4.3 | DisplayString | read-write | The user name for sending problem reports. This value should be cdmipsupport. |
| cdd564SNMP | 1.3.6.1.4.1.6247.25.1.1.5 | |||
| STR cdd564SNMPAuthenticationFailureCommunity | 1.3.6.1.4.1.6247.25.1.1.5.4 | DisplayString | accessible-for-notify | The community that did not match valid SNMP Read or Write community. Note: This is ONLY used in the Authentication Failure trap. |
| IP cdd564SNMPAuthenticationFailureIPAddress | 1.3.6.1.4.1.6247.25.1.1.5.5 | IpAddress | accessible-for-notify | The IP address that did not send a valid SNMP Read or Write community. Note: This is ONLY used in the Authentication Failure trap. |
| STR cdd564SNMPTrapCommunity | 1.3.6.1.4.1.6247.25.1.1.5.2 | DisplayString | read-write | The community that will be included in SNMP notifications (traps) that are sent from unit. |
| IP cdd564SNMPTrapDestinationIPAddress | 1.3.6.1.4.1.6247.25.1.1.5.1 | IpAddress | read-write | The IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a SNMP manager or browser. |
| IP cdd564SNMPTrapDestinationIPAddress2 | 1.3.6.1.4.1.6247.25.1.1.5.6 | IpAddress | read-write | The secondary IP address were SNMP notifications (traps) are to be sent. This IP address should correspond to a secondary SNMP manager or browser. |
| INT cdd564SNMPTrapVersion | 1.3.6.1.4.1.6247.25.1.1.5.3 | INTEGER | read-write | The SNMP version that will be used when sending traps from the unit. SNMPv1 will send V1 traps. SNMPv2 will send V2 notifications. |
| STR cdd564SoftwareRevision | 1.3.6.1.4.1.6247.25.1.8.1.2 | DisplayString | read-only | Unit returns the value of the internal software revision installed in the unit, in the form of x.x.x. |
| INT cdd564StatisticAvgEbNo | 1.3.6.1.4.1.6247.25.1.8.5.1.1.5 | INTEGER | read-only | Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period. |
| STR cdd564StatisticDate | 1.3.6.1.4.1.6247.25.1.8.5.1.1.3 | DisplayString | read-only | The date of the statistic in the form dd/mm/yy, where: dd = day of the month (01 to 31) mm = month (01 to 12) yy = year (00 to 99) |
| INT cdd564StatisticDemod | 1.3.6.1.4.1.6247.25.1.8.5.1.1.1 | INTEGER | read-only | The demod index for which statistics table is being returned. |
| INT cdd564StatisticIndex | 1.3.6.1.4.1.6247.25.1.8.5.1.1.2 | INTEGER | read-only | The index in one of the four demod's stored statistics table. |
| INT cdd564StatisticMinEbNo | 1.3.6.1.4.1.6247.25.1.8.5.1.1.6 | INTEGER | read-only | Minimum Eb/No during sample period. Units = 0.1 dB. Returns 999 if demod was unlocked during sample period. |
| cdd564Statistics | 1.3.6.1.4.1.6247.25.1.6 | |||
| INT cdd564StatisticsSampleInterval | 1.3.6.1.4.1.6247.25.1.8.5.2.1.2 | INTEGER | read-write | Used to set the sample interval for the statistics logging function, where the enumerated lists goes from 0 to 9 in 10 minute steps. Setting 0 disables the statistics logging function. |
| STR cdd564StatisticTime | 1.3.6.1.4.1.6247.25.1.8.5.1.1.4 | DisplayString | read-only | The time of the statistic in the form hh:mm:ss, indicating the time from midnight, where: hh = hours (00 to 23) mm = minutes (00 to 59) ss = seconds (00 to 59) |
| cdd564StoredEvents | 1.3.6.1.4.1.6247.25.1.8.4 | |||
| cdd564StoredEventsEntry | 1.3.6.1.4.1.6247.25.1.8.4.1.1 | not-accessible | The entry for stored events table for all 4 demods. | |
| cdd564StoredEventsTable | 1.3.6.1.4.1.6247.25.1.8.4.1 | not-accessible | The table of stored events for all four demods. | |
| cdd564StoredStatistics | 1.3.6.1.4.1.6247.25.1.8.5 | |||
| cdd564StoredStatisticsConfigEntry | 1.3.6.1.4.1.6247.25.1.8.5.2.1 | not-accessible | The entry for the stored statistics configuration table. | |
| INT cdd564StoredStatisticsConfigIndex | 1.3.6.1.4.1.6247.25.1.8.5.2.1.1 | INTEGER | read-only | The index for the Demodulator. |
| cdd564StoredStatisticsConfigTable | 1.3.6.1.4.1.6247.25.1.8.5.2 | not-accessible | The configuration for the stored statistics (per Demod). | |
| cdd564StoredStatisticsEntry | 1.3.6.1.4.1.6247.25.1.8.5.1.1 | not-accessible | The entry for stored statistics table for all four demods. | |
| cdd564StoredStatisticsTable | 1.3.6.1.4.1.6247.25.1.8.5.1 | not-accessible | The table of stored statistics for all four demods. | |
| INT cdd564SubnetMaskLen | 1.3.6.1.4.1.6247.25.1.2.1.4 | INTEGER | read-write | The subnet mask length of the IP address. |
| INT cdd564Telnet | 1.3.6.1.4.1.6247.25.1.1.2.2 | INTEGER | read-write | Enable or disable telnet access to unit. |
| INT cdd564Temperature | 1.3.6.1.4.1.6247.25.1.8.1.5 | INTEGER | read-only | Unit returns the value of the internal temperature, in degrees Celsius. |
| C32 cdd564TotalBroadcastsToEthernet | 1.3.6.1.4.1.6247.25.1.6.1.1.4 | Counter32 | read-only | The total number of Broadcast packets routed to the Ethernet interface. |
| C32 cdd564TotalDroppedPackets | 1.3.6.1.4.1.6247.25.1.6.1.5.1 | Counter32 | read-only | The total number of packets dropped by the router. |
| C32 cdd564TotalMulticastsToEthernet | 1.3.6.1.4.1.6247.25.1.6.1.1.3 | Counter32 | read-only | The total number of Multicast packets routed to the Ethernet interface. |
| C32 cdd564TotalPacketsFromEndstation | 1.3.6.1.4.1.6247.25.1.6.1.3.1 | Counter32 | read-only | The total number of packets received from the Endstation to be sent out one of the interfaces. |
| C32 cdd564TotalPacketsFromEthernet | 1.3.6.1.4.1.6247.25.1.6.1.1.5 | Counter32 | read-only | The total number of IP packets received from the Ethernet interface. |
| C32 cdd564TotalPacketsFromSatellite | 1.3.6.1.4.1.6247.25.1.6.1.2.1 | Counter32 | read-only | The total number of IP packets received from the satellite interfaces. |
| C32 cdd564TotalPacketsToEndstation | 1.3.6.1.4.1.6247.25.1.6.1.3.2 | Counter32 | read-only | The total number of packets sent to the Endstation from one of the interfaces. |
| C32 cdd564TotalPacketsToEthernet | 1.3.6.1.4.1.6247.25.1.6.1.1.1 | Counter32 | read-only | The total number of IP packets routed to the Ethernet interface. |
| C32 cdd564TotalUnicastsToEthernet | 1.3.6.1.4.1.6247.25.1.6.1.1.2 | Counter32 | read-only | The total number of Unicast packets routed to the Ethernet interface. |
| INT cdd564UnitAlarm | 1.3.6.1.4.1.6247.25.1.8.1.4 | INTEGER | read-only | Modem Unit Faults: Value Description of unit fault 0 No faults 1 +5 Volt power supply 2 +12 Volt power supply 3 -5 Volt power supply 4 +23 Volt power supply 5 -12 Volt power supply 6 Rx 1st LO synthesize lock 7 Rx 2nd LO synthesize lock 8 Ref PLL lock 9 EEPROM checksum error |
| NTF cdd564UnitAlarmNotification | 1.3.6.1.4.1.6247.25.2.0.1 | Trap for Unit alarms. | ||
| cdd564UnitInformation | 1.3.6.1.4.1.6247.25.1.5.1 | |||
| cdd564UnitMonitor | 1.3.6.1.4.1.6247.25.1.8.1 | |||
| INT cdd564UpgradeImage | 1.3.6.1.4.1.6247.25.1.5.2.2 | INTEGER | read-write | Specifies which image will be overwritten during an upgrade: oldest - overwrites the oldest image determined by build date. image 1 - overwrites image 1 image 2 - overwrites image 2 NOTE: Set this value before performing an upgrade. |
| cdd564Util | 1.3.6.1.4.1.6247.25.1.9 | |||
| INT cdd564WorkingMode | 1.3.6.1.4.1.6247.25.1.1.2.6 | INTEGER | read-write | Configure the system's working mode. The CDM-IP can operate in any of these modes. 1. Router - Small Network Mode - The system functions as router and uses the route table to determine how to forward packets in a small network HDLC address mode. The HDLC packet uses a 1 byte HDLC address. The valid values are from 1 to 254 (0x1 - 0xFE). 2. Router - Small Network Mode - The system functions as router and uses the route table to determine how to forward packets in a large network HDLC address mode. The HDLC packet uses a 2- byte HDLC address. The valid values are from 1 to 32766 (0x1 - 0x7FFE). 3. Router - Point To Point Mode - The system functions as router but does not use HDLC addresses. 4. Router - Vipersat Mode - The system functions as router and is configured to work in a Vipersat network. *** IMPORTANT NOTE *** Changing Working mode requires the system to reboot. System configuration is saved before rebooting. Please make sure you are setting the correct value. |
| INT cddRxBERMultiplier | 1.3.6.1.4.1.6247.25.1.8.2.1.1.7 | INTEGER | read-only | Estimated corrected BER. The BER is calculated by multiplying the Multiplier by 10E-10. Calculuation: RxBER = (Multiplier) * 0.0000000001 Returns 2147483647 (max int) if demod is unlocked. |
| INT cdm564LLNBLowCurrentLimit | 1.3.6.1.4.1.6247.25.1.7.4.1.1.4 | INTEGER | read-write | LNB lower alarm limit for current, between 10 and 400 mA. |
RFC description
Comtech EF Data CDD-564 satellite demodulator configuration and monitoring.
Start monitoring Comtech EF Data CDD-564 satellite demodulator with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.