CDD-564 :: cdd564RxDemodulation

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCDD-564cdd564RxDemodulation

cdd564RxDemodulation

Module: CDD-564

OID (symbolic): CDD-564::cdd564RxDemodulation

OID (numeric): 1.3.6.1.4.1.6247.25.1.7.1.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Rx demodulation type, where: 1 = QPSK 3 = 8-PSK 4 = 16-QAM

What is cdd564RxDemodulation?

This read-write object sets the receive demodulation type to one of QPSK(1), 8-PSK(3), or 16-QAM(4). This setting must exactly match what the far-end transmitter is sending, since a demodulator configured for the wrong constellation, for example set to 16-QAM while the transmitter sends QPSK, will simply fail to lock regardless of how strong the received signal is. A demodulator stuck showing demodulatorUnlocked(1) in cdd564RxAlarm despite a strong signal level reading is a classic symptom of this object being set to the wrong modulation scheme for the incoming carrier.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.7.1.1.1.3
snmpwalk -v2c -c public <target> CDD-564::cdd564RxDemodulation

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.7.1.1.1.3.1
snmpget -v2c -c public <target> CDD-564::cdd564RxDemodulation.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6247.25.1.7.1.1.1.3.1 i <value>

Start monitoring Comtech EF Data CDD-564 satellite demodulator with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDD-564::cdd564RxDemodulation OID value, configure state conditions and alerts, and monitor any Comtech EF Data CDD-564 satellite demodulator from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6247comtechEFDataComtechEFData
Numeric OIDNameModule
1.3.6.1.4.1.6247.25cdd564CDD-564
1.3.6.1.4.1.6247.25.1cdd564ObjectsCDD-564
1.3.6.1.4.1.6247.25.1.7cdd564ConfigCDD-564
1.3.6.1.4.1.6247.25.1.7.1cdd564RxCDD-564
1.3.6.1.4.1.6247.25.1.7.1.1cdd564RxTableCDD-564
1.3.6.1.4.1.6247.25.1.7.1.1.1cdd564RxEntryCDD-564
1.3.6.1.4.1.6247.25.1.7.1.1.1.3cdd564RxDemodulationCDD-564