All MIBs › CDD-564 › cdd564LNBDCPower
cdd564LNBDCPower
Module: CDD-564
OID (symbolic): CDD-564::cdd564LNBDCPower
OID (numeric): 1.3.6.1.4.1.6247.25.1.7.4.1.1.2
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: LNB power control, where: 0 = Off 1 = On, 13V LNB voltage 2 = On, 18V LNB voltage 3 = On, 24V LNB voltage
What is cdd564LNBDCPower?
This read-write object controls LNB power: off(0), on at 13V(1), on at 18V(2), or on at 24V(3). The chosen voltage typically selects LNB polarization or band on dual-band/dual-polarity LNBs, a common convention being 13V for one polarization and 18V for the other, so setting the wrong voltage here can leave the antenna feed receiving the wrong polarization entirely, presenting as a completely unlocked demodulator despite correct pointing and frequency. If a technician swaps to a transponder that requires vertical rather than horizontal polarization, they'd typically need to change this object from 13V(1) to 18V(2) to actually feed the correct polarity to the demodulator.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.7.4.1.1.2 snmpwalk -v2c -c public <target> CDD-564::cdd564LNBDCPower
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.7.4.1.1.2.1 snmpget -v2c -c public <target> CDD-564::cdd564LNBDCPower.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6247.25.1.7.4.1.1.2.1 i <value>
Start monitoring Comtech EF Data CDD-564 satellite demodulator with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDD-564::cdd564LNBDCPower OID value, configure state conditions and alerts, and monitor any Comtech EF Data CDD-564 satellite demodulator from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6247 | comtechEFData | ComtechEFData |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6247.25 | cdd564 | CDD-564 |
| 1.3.6.1.4.1.6247.25.1 | cdd564Objects | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.7 | cdd564Config | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.7.4 | cdd564LNB | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.7.4.1 | cdd564LNBTable | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.7.4.1.1 | cdd564LNBEntry | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.7.4.1.1.2 | cdd564LNBDCPower | CDD-564 |