CDD-564 :: cdd564RestoreFactoryDefaults

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCDD-564cdd564RestoreFactoryDefaults

cdd564RestoreFactoryDefaults

Module: CDD-564

OID (symbolic): CDD-564::cdd564RestoreFactoryDefaults

OID (numeric): 1.3.6.1.4.1.6247.25.1.5.3.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This is a SET command that restore the configuration to the factory defaults.

*** Imporant *** Setting this command ERASES the parameter file in flash.

What is cdd564RestoreFactoryDefaults?

Writing restore(1) to this object is a SET command that resets the CDD-564's configuration to factory defaults and, critically, erases the parameter file stored in flash. This is a destructive, one-way operation flagged in the MIB itself with an 'Important' warning, so an admin would only use it when the unit's saved configuration is so corrupted or misconfigured that starting clean is preferable to troubleshooting it, since there is no saved-flash fallback to reload afterward. A technician replacing a misconfigured unit pulled from another site (with someone else's IP addresses, Rx frequency, and LNB voltage baked in) would SET this object to restore(1) to wipe that inherited configuration before re-provisioning it for the new location.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.5.3.4
snmpwalk -v2c -c public <target> CDD-564::cdd564RestoreFactoryDefaults

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.5.3.4.1
snmpget -v2c -c public <target> CDD-564::cdd564RestoreFactoryDefaults.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6247.25.1.5.3.4.1 i <value>

Start monitoring Comtech EF Data CDD-564 satellite demodulator with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDD-564::cdd564RestoreFactoryDefaults OID value, configure state conditions and alerts, and monitor any Comtech EF Data CDD-564 satellite demodulator from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6247comtechEFDataComtechEFData
Numeric OIDNameModule
1.3.6.1.4.1.6247.25cdd564CDD-564
1.3.6.1.4.1.6247.25.1cdd564ObjectsCDD-564
1.3.6.1.4.1.6247.25.1.5cdd564MaintCDD-564
1.3.6.1.4.1.6247.25.1.5.3cdd564ParamDatabaseCDD-564
1.3.6.1.4.1.6247.25.1.5.3.4cdd564RestoreFactoryDefaultsCDD-564