All MIBs › CDD-564 › cdd564SMTPServerIPAddress
cdd564SMTPServerIPAddress
Module: CDD-564
OID (symbolic): CDD-564::cdd564SMTPServerIPAddress
OID (numeric): 1.3.6.1.4.1.6247.25.1.1.4.1
Node type: OBJECT-TYPE
Type: IpAddress
Access: read-write
Description: The IP address of the SMTP server for sending problem reports. This IP adderess should correspond to a local Mail server.
What is cdd564SMTPServerIPAddress?
This is the address of the SMTP relay the unit connects to when emailing its automated problem reports, and per the field's own guidance this should point at a local mail server rather than a distant or public one. Because this unit sits behind a limited and often expensive satellite backhaul, routing alert emails through a nearby relay avoids the unit having to establish its own SMTP session across the constrained link, which could fail or be blocked entirely on some satellite paths. For example, pointing this at an on-site mail relay at 192.168.1.25 keeps automated alert delivery working reliably even if direct outbound SMTP to the public internet is filtered on that link.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.1.4.1 snmpwalk -v2c -c public <target> CDD-564::cdd564SMTPServerIPAddress
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.1.4.1.1 snmpget -v2c -c public <target> CDD-564::cdd564SMTPServerIPAddress.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.6247.25.1.1.4.1.1 a <value>
Start monitoring Comtech EF Data CDD-564 satellite demodulator with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDD-564::cdd564SMTPServerIPAddress OID value, configure state conditions and alerts, and monitor any Comtech EF Data CDD-564 satellite demodulator from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6247 | comtechEFData | ComtechEFData |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6247.25 | cdd564 | CDD-564 |
| 1.3.6.1.4.1.6247.25.1 | cdd564Objects | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.1 | cdd564Administration | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.1.4 | cdd564SMTP | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.1.4.1 | cdd564SMTPServerIPAddress | CDD-564 |