All MIBs › CDD-564 › cdd564RxMemoryAlignmentErrors
cdd564RxMemoryAlignmentErrors
Module: CDD-564
OID (symbolic): CDD-564::cdd564RxMemoryAlignmentErrors
OID (numeric): 1.3.6.1.4.1.6247.25.1.6.3.1.1.13
Node type: OBJECT-TYPE
Type: Counter32
Access: read-only
Description: The number of frames which were incorrectly transferred (frame too small) from the Rx FPGA.
What is cdd564RxMemoryAlignmentErrors?
This counter tracks frames that were incorrectly transferred -- specifically frames that arrived too small -- from the Rx FPGA. This is a hardware data-path symptom internal to the receiver's FPGA-to-memory transfer, distinct from RF-layer or protocol-layer errors, so a rising count here without corresponding degradation in Eb/No points toward an internal hardware fault in the receive chain rather than the satellite signal. A technician seeing this counter climb on an otherwise RF-healthy link would consider it grounds for suspecting a hardware fault in the Rx FPGA or its memory interface and potentially requesting a unit swap.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.6.3.1.1.13 snmpwalk -v2c -c public <target> CDD-564::cdd564RxMemoryAlignmentErrors
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6247.25.1.6.3.1.1.13.1 snmpget -v2c -c public <target> CDD-564::cdd564RxMemoryAlignmentErrors.1
Start monitoring Comtech EF Data CDD-564 satellite demodulator with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CDD-564::cdd564RxMemoryAlignmentErrors OID value, configure state conditions and alerts, and monitor any Comtech EF Data CDD-564 satellite demodulator from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6247 | comtechEFData | ComtechEFData |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6247.25 | cdd564 | CDD-564 |
| 1.3.6.1.4.1.6247.25.1 | cdd564Objects | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.6 | cdd564Statistics | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.6.3 | cdd564SatelliteStatistics | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.6.3.1 | cdd564SatelliteRxStatsTable | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.6.3.1.1 | cdd564SatelliteRxStatsEntry | CDD-564 |
| 1.3.6.1.4.1.6247.25.1.6.3.1.1.13 | cdd564RxMemoryAlignmentErrors | CDD-564 |