Description: Proprietary UPS MIB providing management objects for three-phase power, battery, and module status monitoring on enterprise UPS systems.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is EPPC-MIB?

This is a proprietary UPS (uninterruptible power supply) MIB providing management objects for enterprise three-phase UPS systems, covering power, battery, and module status. Based on its object hierarchy (upsAgent, upsE, upsEIdentity, and associated traps), it exposes power-subsystem data such as UPS identity/agent information and status of UPS modules, consistent with typical UPS MIB structures covering input/output power, battery charge, and load. Its core purpose is monitoring the hardware status of the UPS itself, including battery health, module/phase status, and fault conditions communicated via upsETraps, making it directly relevant to power infrastructure uptime monitoring. No dependency on another standard MIB is indicated in the provided material, suggesting it is a vendor-specific, self-contained UPS MIB rather than an extension of the standard UPS-MIB (RFC 1628). It is deployed in data centers and facilities using three-phase UPS systems from this vendor to protect critical power infrastructure for racks of network and server equipment. Engineers can download the EPPC-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in EPPC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • three-phase UPS systems

Monitoring Examples

An administrator would poll objects under upsEIdentity to confirm the UPS model/agent identity and firmware are as expected, and monitor status objects under upsE/upsAgent for battery and module health to catch a failing battery module before it causes an outage. Receiving a trap from upsETraps would alert the admin to an event such as a phase failure, battery low condition, or module fault requiring immediate attention on a three-phase UPS supporting critical infrastructure.

What Can Be Monitored

  • UPS module status
  • battery status
  • power/phase status
  • UPS fault/event traps
Imported Objects

From RFC-1212

OBJECT-TYPE

From RFC-1215

TRAP-TYPE

From RFC1155-SMI

Counter
IpAddress
enterprises

From SNMPv2-TC

DisplayString

From UPS-MIB

NonNegativeInteger
PositiveInteger
OIDs

RFC description

UPS system MIB for managing uninterruptible power supplies, including battery, power converter, load segment, environmental monitoring, and battery testing.

Start monitoring Three-phase UPS system with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download EPPC-MIB