All MIBs › LIEBERT-UPS-MIB
Category: Domain: Power/UPS, Vendor: Liebert
Description: General Liebert UPS SNMP MIB providing battery status, input/output voltage, load, and alarm objects for uninterruptible power supplies.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is LIEBERT-UPS-MIB?
LIEBERT-UPS-MIB is a general-purpose Liebert (now Vertiv) enterprise MIB for monitoring uninterruptible power supply (UPS) units, covering battery status, input and output voltage, load level, and alarm conditions. Its data categories are squarely environmental/power-health: battery state of charge and condition, AC input/output voltage readings, present load as a percentage of capacity, and a set of alarm objects for fault conditions such as on-battery operation, low battery, or overload. This is directly a hardware-health monitoring MIB -- battery status and alarm objects are exactly what an operator watches to know whether the UPS is running normally on utility power, has switched to battery during an outage, or is approaching battery depletion, all critical for protecting the equipment it powers. No sample objects were available for this module to confirm exact naming, but the described scope aligns with the standard structure common to UPS MIBs (battery, input, output, alarm groups). It is deployed on Liebert UPS units protecting data center, telecom, and critical-facility equipment from power interruptions. Network engineers evaluating or troubleshooting this functionality can download the LIEBERT-UPS-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in LIEBERT-UPS-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Liebert (Vertiv) UPS units
Monitoring Examples
Because no sample objects were provided, a fully object-grounded example cannot be given with certainty; in general, a facilities engineer would poll the UPS's battery status and alarm objects to confirm whether the unit is on utility power or has switched to battery. They would also check output load and voltage objects to ensure the UPS isn't approaching its rated capacity. A battery-status alarm combined with a rising load percentage would indicate the UPS is running on battery under load during a utility outage, warranting an escalation before battery depletion.
What Can Be Monitored
- battery status/condition
- input voltage
- output voltage
- load percentage
- UPS alarm conditions
This MIB depends on
Related MIBs
Imported Objects
From RFC-1212
| OBJECT-TYPE |
From RFC-1215
| TRAP-TYPE |
From RFC1155-SMI
| Counter | |
| Gauge | |
| TimeTicks | |
| enterprises |
From RFC1213-MIB
| DisplayString | |
| sysUpTime |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| emerson | 1.3.6.1.4.1.476 | |||
| lcUpsAlarm | 1.3.6.1.4.1.476.1.1.1.1.6 | |||
| lcUpsAlarmAmbientOverTemp | 1.3.6.1.4.1.476.1.1.1.1.6.3.29 | |||
| lcUpsAlarmAutoRexferPrimed | 1.3.6.1.4.1.476.1.1.1.1.6.3.43 | |||
| lcUpsAlarmBattCycleBuffWarn | 1.3.6.1.4.1.476.1.1.1.1.6.3.44 | |||
| lcUpsAlarmBatteryBad | 1.3.6.1.4.1.476.1.1.1.1.6.3.9 | |||
| lcUpsAlarmBatteryCbOpen | 1.3.6.1.4.1.476.1.1.1.1.6.3.37 | |||
| lcUpsAlarmConditions | 1.3.6.1.4.1.476.1.1.1.1.6.3 | |||
| lcUpsAlarmControlPowerFailed | 1.3.6.1.4.1.476.1.1.1.1.6.3.32 | |||
| lcUpsAlarmDCgroundFault | 1.3.6.1.4.1.476.1.1.1.1.6.3.34 | |||
| lcUpsAlarmDCOverVoltageShutdown | 1.3.6.1.4.1.476.1.1.1.1.6.3.18 | |||
| OID lcUpsAlarmDescr | 1.3.6.1.4.1.476.1.1.1.1.6.2.1.2 | OBJECT IDENTIFIER | read-only | A reference to an alarm description object. The object referenced should not be accessible, but rather be used to provide a unique description of the alarm condition. |
| lcUpsAlarmEmergencyPowerOff | 1.3.6.1.4.1.476.1.1.1.1.6.3.30 | |||
| lcUpsAlarmEmergencyXferToBypass | 1.3.6.1.4.1.476.1.1.1.1.6.3.24 | |||
| lcUpsAlarmEntry | 1.3.6.1.4.1.476.1.1.1.1.6.2.1 | not-accessible | ||
| lcUpsAlarmFanFailed | 1.3.6.1.4.1.476.1.1.1.1.6.3.31 | |||
| lcUpsAlarmFuseBlown | 1.3.6.1.4.1.476.1.1.1.1.6.3.28 | |||
| lcUpsAlarmHardwareShutdown | 1.3.6.1.4.1.476.1.1.1.1.6.3.23 | |||
| INT lcUpsAlarmId | 1.3.6.1.4.1.476.1.1.1.1.6.2.1.1 | INTEGER | read-only | A unique identifier for an alarm condition. This value must remain constant between agent initializations. |
| lcUpsAlarmInputCbOpen | 1.3.6.1.4.1.476.1.1.1.1.6.3.38 | |||
| lcUpsAlarmInputFreqError | 1.3.6.1.4.1.476.1.1.1.1.6.3.13 | |||
| lcUpsAlarmInputOverVoltage | 1.3.6.1.4.1.476.1.1.1.1.6.3.8 | |||
| lcUpsAlarmInverterFault | 1.3.6.1.4.1.476.1.1.1.1.6.3.25 | |||
| lcUpsAlarmLoadOnBypass | 1.3.6.1.4.1.476.1.1.1.1.6.3.35 | |||
| lcUpsAlarmLowBatteryShutdown | 1.3.6.1.4.1.476.1.1.1.1.6.3.2 | |||
| lcUpsAlarmLowBatteryWarning | 1.3.6.1.4.1.476.1.1.1.1.6.3.1 | |||
| lcUpsAlarmManualResetXfer | 1.3.6.1.4.1.476.1.1.1.1.6.3.42 | |||
| lcUpsAlarmModuleSummary | 1.3.6.1.4.1.476.1.1.1.1.6.3.45 | |||
| lcUpsAlarmOnBattery | 1.3.6.1.4.1.476.1.1.1.1.6.3.10 | |||
| lcUpsAlarmOutputCbOpen | 1.3.6.1.4.1.476.1.1.1.1.6.3.39 | |||
| lcUpsAlarmOutputFreqError | 1.3.6.1.4.1.476.1.1.1.1.6.3.40 | |||
| lcUpsAlarmOutputOverloadShutdown | 1.3.6.1.4.1.476.1.1.1.1.6.3.7 | |||
| lcUpsAlarmOutputOverloadWarning | 1.3.6.1.4.1.476.1.1.1.1.6.3.6 | |||
| lcUpsAlarmOutputOverVoltage | 1.3.6.1.4.1.476.1.1.1.1.6.3.16 | |||
| lcUpsAlarmOutputUnderVoltage | 1.3.6.1.4.1.476.1.1.1.1.6.3.15 | |||
| lcUpsAlarmOverTempShutdown | 1.3.6.1.4.1.476.1.1.1.1.6.3.5 | |||
| lcUpsAlarmOverTempWarning | 1.3.6.1.4.1.476.1.1.1.1.6.3.4 | |||
| lcUpsAlarmPhaseRotationError | 1.3.6.1.4.1.476.1.1.1.1.6.3.26 | |||
| lcUpsAlarmReversePower | 1.3.6.1.4.1.476.1.1.1.1.6.3.33 | |||
| GAU lcUpsAlarms | 1.3.6.1.4.1.476.1.1.1.1.6.1 | Gauge | read-only | The current number of alarm conditions. |
| lcUpsAlarmStaticSwUnable | 1.3.6.1.4.1.476.1.1.1.1.6.3.41 | |||
| lcUpsAlarmStopNoticeIssued | 1.3.6.1.4.1.476.1.1.1.1.6.3.11 | |||
| lcUpsAlarmTable | 1.3.6.1.4.1.476.1.1.1.1.6.2 | not-accessible | ||
| TIK lcUpsAlarmTime | 1.3.6.1.4.1.476.1.1.1.1.6.2.1.3 | TimeTicks | read-only | The value of sysUpTime when the alarm condition occured. |
| NTF lcUpsAlarmTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.11 | An Alarm condition has occurred and is being reported in the lcUpsAlarmTable. | ||
| lcUpsAlarmUpsOff | 1.3.6.1.4.1.476.1.1.1.1.6.3.12 | |||
| lcUpsAlarmUtilFailed | 1.3.6.1.4.1.476.1.1.1.1.6.3.3 | |||
| lcUpsBadBypassPower | 1.3.6.1.4.1.476.1.1.1.1.6.3.17 | |||
| CTR lcUpsBatAmpHours | 1.3.6.1.4.1.476.1.1.1.1.2.9 | Counter | read-only | The number of amp hours withdrawn from battery. |
| INT lcUpsBatCapacity | 1.3.6.1.4.1.476.1.1.1.1.2.6 | INTEGER | read-only | The current battery capacity in percentage of total available. |
| INT lcUpsBatCurrent | 1.3.6.1.4.1.476.1.1.1.1.2.4 | INTEGER | read-only | The current battery discharging/charging current. (Unit of measure: Amp) |
| CTR lcUpsBatCycleDurationInSeconds | 1.3.6.1.4.1.476.1.1.1.1.2.8 | Counter | read-only | The total accumulated discharge time in seconds. |
| CTR lcUpsBatKWhours | 1.3.6.1.4.1.476.1.1.1.1.2.10 | Counter | read-only | The number of Kilowatt-hours withdrawn from battery. |
| INT lcUpsBatTemperature | 1.3.6.1.4.1.476.1.1.1.1.2.2 | INTEGER | read-only | The battery temperature. (Unit of measure: Degree, Centigrade) |
| lcUpsBattery | 1.3.6.1.4.1.476.1.1.1.1.2 | |||
| INT lcUpsBatTimeRemaining | 1.3.6.1.4.1.476.1.1.1.1.2.1 | INTEGER | read-only | The estimated time to depletion of battery charge. (Unit of measure: Minute) |
| CTR lcUpsBatTotalDischCounts | 1.3.6.1.4.1.476.1.1.1.1.2.7 | Counter | read-only | The number of discharges the UPS has experienced. |
| INT lcUpsBatVoltage | 1.3.6.1.4.1.476.1.1.1.1.2.3 | INTEGER | read-only | The current battery voltage. (Unit of measure: volt) |
| CTR lcUpsBatWattHours | 1.3.6.1.4.1.476.1.1.1.1.2.11 | Counter | read-only | The number of Watt-hours withdrawn from battery. |
| lcUpsBypass | 1.3.6.1.4.1.476.1.1.1.1.13 | |||
| INT lcUpsBypassCurrent | 1.3.6.1.4.1.476.1.1.1.1.13.4.1.3 | INTEGER | read-only | The bypass current. (Unit of measure: Amp) |
| lcUpsBypassEntry | 1.3.6.1.4.1.476.1.1.1.1.13.4.1 | not-accessible | ||
| INT lcUpsBypassFrequency | 1.3.6.1.4.1.476.1.1.1.1.13.2 | INTEGER | read-only | The current bypass frequency. (Unit of measure: Hertz) |
| INT lcUpsBypassLine | 1.3.6.1.4.1.476.1.1.1.1.13.4.1.1 | INTEGER | read-only | The bypass Line. |
| INT lcUpsBypassNumLines | 1.3.6.1.4.1.476.1.1.1.1.13.3 | INTEGER | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. |
| lcUpsBypassTable | 1.3.6.1.4.1.476.1.1.1.1.13.4 | not-accessible | ||
| INT lcUpsBypassVoltage | 1.3.6.1.4.1.476.1.1.1.1.13.4.1.2 | INTEGER | read-only | The bypass voltage. (Unit of measure: Volt) |
| lcUpsConfig | 1.3.6.1.4.1.476.1.1.1.1.14 | |||
| INT lcUpsConfigAudibleStatus | 1.3.6.1.4.1.476.1.1.1.1.14.5 | INTEGER | read-write | The requested state of the audible alarm. When in the disabled state, the audible alarm should never sound. The enabled state is self-describing. Setting this object to muted(3) when the audible alarm is sounding shall temporarily silence the alarm. |
| INT lcUpsConfigAutoRestart | 1.3.6.1.4.1.476.1.1.1.1.14.7 | INTEGER | read-write | Setting this object will start the output after the indicated number of ticks (1 tick = 10 seconds), including starting the UPS, if necessary. Setting this object to 0 will cause the startup to occur immediately. Setting this object to -1 will disable autorestart. |
| INT lcUpsConfigBypassInstalled | 1.3.6.1.4.1.476.1.1.1.1.14.2 | INTEGER | read-only | Indicates if a bypass is installed in the UPS. |
| INT lcUpsConfigCurrentModule | 1.3.6.1.4.1.476.1.1.1.1.14.4 | INTEGER | read-write | A number identifying which module of a multi-module UPS is currently being monitored. |
| INT lcUpsConfigLowBattTime | 1.3.6.1.4.1.476.1.1.1.1.14.6 | INTEGER | read-write | The value of lcUpsBatTimeRemaining at which a lowBatteryWarning condition is declared. (Unit of measure: Minute) |
| INT lcUpsConfigModuleCount | 1.3.6.1.4.1.476.1.1.1.1.14.3 | INTEGER | read-only | A number identifying how many multi-module UPS are connected to the System Control Cabinet. |
| INT lcUpsConfigType | 1.3.6.1.4.1.476.1.1.1.1.14.1 | INTEGER | read-only | Indicates the UPS topology. |
| lcUpsControl | 1.3.6.1.4.1.476.1.1.1.1.8 | |||
| INT lcUpsControlCancelCommands | 1.3.6.1.4.1.476.1.1.1.1.8.7 | INTEGER | read-write | Setting this variable to 'cancel' will cause the agent to issue instructions to the UPS to cancel all outstanding commands, such as lcUpsControlOutputOff, lcUpsControlOutputOn, lcUpsControlUnixShutdown. |
| INT lcUpsControlOutputOffDelay | 1.3.6.1.4.1.476.1.1.1.1.8.1 | INTEGER | read-write | Setting this object causes the agent to instruct the UPS to turn off the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel. |
| INT lcUpsControlOutputOffTrapDelay | 1.3.6.1.4.1.476.1.1.1.1.8.3 | INTEGER | read-write | When 'lcUpsControlOutputOffDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOffWarningTrap will be produced and this object will be reset to 0. |
| INT lcUpsControlOutputOnDelay | 1.3.6.1.4.1.476.1.1.1.1.8.2 | INTEGER | read-write | Setting this object causes the agent to instruct the UPS to turn on the output after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsOutputOnTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value cancel. |
| INT lcUpsControlOutputOnTrapDelay | 1.3.6.1.4.1.476.1.1.1.1.8.4 | INTEGER | read-write | When 'lcUpsControlOutputOnDelay' reaches a value less than or equal to this object's value, an lcUpsOutputOnWarningTrap will be produced and this object will be reset to 0. |
| NTF lcUpsControlPowerFailureTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.27 | An lcUpsControlPowerFailureTrap signifies a failure in the secondary control power. | ||
| INT lcUpsControlRebootAgentDelay | 1.3.6.1.4.1.476.1.1.1.1.8.8 | INTEGER | read-write | Setting this object causes the agent to reboot after the indicated number of seconds have expired. The value will count down until the event takes place. |
| INT lcUpsControlUnixShutdownDelay | 1.3.6.1.4.1.476.1.1.1.1.8.5 | INTEGER | read-write | Setting this object causes the agent to instruct the UPS to perform a UNIX Shutdown in the indicated number of seconds. The agent counts down the number of seconds until the event will take place. A Unix shutdown is only valid if the UPS is on Battery. During a UNIX Shutdown, the UPS will turn off the output even if the Utility comes back on line before the shutdown time arrives. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsControlCancelCommand to the value 'cancel'. |
| INT lcUpsControlUnixShutdownTrapDelay | 1.3.6.1.4.1.476.1.1.1.1.8.6 | INTEGER | read-write | When 'lcUpsControlUnixShutdownDelay' reaches a value less than or equal to this object's value, an lcUpsUnixShutdownWarningTrap will be produced and this object will be reset to 0. |
| NTF lcUpsDCOverVoltageShutdownTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.23 | An lcUpsDCOverVoltageShutdownTrap signifies that the UPS has detected that battery voltage is over the tolarable level. | ||
| NTF lcUpsEmergencyPowerOffTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.26 | An lcUpsEmergencyPowerOffTrap signifies that the UPS has shut off output due to an emergency condition. | ||
| NTF lcUpsEmergencyXferToBypassTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.31 | An lcUpsEmergencyXferToBypassTrap signifies that the UPS has automatically tranferred the load to bypass power. | ||
| NTF lcUpsFuseBlownTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.25 | An lcUpsFuseBlownTrap is sent when the UPS's rectifier or DC capacitor fuse has failed. | ||
| lcUpsIdent | 1.3.6.1.4.1.476.1.1.1.1.1 | |||
| STR lcUpsIdentFirmwareVersion | 1.3.6.1.4.1.476.1.1.1.1.1.5 | DisplayString | read-only | The firmware revision level of the UPS. |
| STR lcUpsIdentManufactureDate | 1.3.6.1.4.1.476.1.1.1.1.1.7 | DisplayString | read-only | The date of manufacture of the UPS. |
| STR lcUpsIdentManufacturer | 1.3.6.1.4.1.476.1.1.1.1.1.1 | DisplayString | read-only | The UPS manufacturer. |
| STR lcUpsIdentModel | 1.3.6.1.4.1.476.1.1.1.1.1.2 | DisplayString | read-write | The UPS Model designation. |
| STR lcUpsIdentSerialNumber | 1.3.6.1.4.1.476.1.1.1.1.1.6 | DisplayString | read-only | The serial number of the UPS. |
| STR lcUpsIdentSoftwareVersion | 1.3.6.1.4.1.476.1.1.1.1.1.3 | DisplayString | read-only | The UPS SNMP Agent software version. |
| OID lcUpsIdentSpecific | 1.3.6.1.4.1.476.1.1.1.1.1.4 | OBJECT IDENTIFIER | read-only | A reference to MIB definitions specific to the particular UPS being managed. This object is used to locate the product-specific MIB for this device. If this information is not present, its value should be the OBJECT IDENTIFIER { 0 0 }, which is a syntactically valid object identifier, and any conformant implementation of ASN.1 and BER must be able to generate and recognize this value. |
| lcUpsInput | 1.3.6.1.4.1.476.1.1.1.1.3 | |||
| CTR lcUpsInputBlackOuts | 1.3.6.1.4.1.476.1.1.1.1.3.3 | Counter | read-only | The number of black-out conditions the UPS has experienced. |
| CTR lcUpsInputBrownOuts | 1.3.6.1.4.1.476.1.1.1.1.3.2 | Counter | read-only | The number of brown-out conditions the UPS has experienced. |
| INT lcUpsInputCurrent | 1.3.6.1.4.1.476.1.1.1.1.3.6.1.3 | INTEGER | read-only | The input current. (Unit of measure: Amp) |
| lcUpsInputEntry | 1.3.6.1.4.1.476.1.1.1.1.3.6.1 | not-accessible | ||
| NTF lcUpsInputFreqErrorTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.22 | An ldUpsInputFreqErrorTrap signifies that the UPS has detected that input frequency is outside tolerable variance. | ||
| INT lcUpsInputFrequency | 1.3.6.1.4.1.476.1.1.1.1.3.1 | INTEGER | read-only | The current input frequency. (Unit of measure: Hertz) |
| INT lcUpsInputLine | 1.3.6.1.4.1.476.1.1.1.1.3.6.1.1 | INTEGER | read-only | The input Line. |
| INT lcUpsInputNumLines | 1.3.6.1.4.1.476.1.1.1.1.3.5 | INTEGER | read-only | The number of input lines utilized in this device. This entry indicates the number of rows in the input table. |
| NTF lcUpsInputOverVoltageTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.8 | An lcUpsInputOverVoltageTrap signifies that the UPS has detected a high input voltage condition. | ||
| lcUpsInputTable | 1.3.6.1.4.1.476.1.1.1.1.3.6 | not-accessible | ||
| CTR lcUpsInputTransients | 1.3.6.1.4.1.476.1.1.1.1.3.4 | Counter | read-only | The number of transient (surge and spike) conditions the UPS has experienced. |
| INT lcUpsInputVA | 1.3.6.1.4.1.476.1.1.1.1.3.6.1.4 | INTEGER | read-only | The input volt-amps. |
| INT lcUpsInputVoltage | 1.3.6.1.4.1.476.1.1.1.1.3.6.1.2 | INTEGER | read-only | The input voltage. (Unit of measure: Volt) |
| lcUpsInverter | 1.3.6.1.4.1.476.1.1.1.1.5 | |||
| NTF lcUpsInverterFaultTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.34 | An lcUpsInverterFaultTrap signifies that the UPS detected a problem with the Inverter. | ||
| INT lcUpsInverterStatus | 1.3.6.1.4.1.476.1.1.1.1.5.1 | INTEGER | read-only | The state of the inverter. Unknown is returned if the state can not be determined. |
| INT lcUpsInverterTemp | 1.3.6.1.4.1.476.1.1.1.1.5.2 | INTEGER | read-only | The temperature of the inverter. (Unit of measure: degree, Centigrade) |
| lcUpsLineCorrectionActive | 1.3.6.1.4.1.476.1.1.1.1.6.3.46 | |||
| NTF lcUpsLoadOnBypassTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.30 | An lcUpsLoadOnBypassTrap signifies that the load has been transferred to bypass power. | ||
| NTF lcUpsLowBatteryShutdownTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.5 | An lcUpsLowBatteryShutdownTrap signifies that the UPS has shut off the output due to a Low Battery state. | ||
| NTF lcUpsLowBatteryWarningTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.4 | An lcUpsLowBatteryWarningTrap signifies that the UPS has entered a Low Battery state. | ||
| lcUpsNominal | 1.3.6.1.4.1.476.1.1.1.1.9 | |||
| INT lcUpsNominalInputFreq | 1.3.6.1.4.1.476.1.1.1.1.9.6 | INTEGER | read-write | The nominal input frequency. (Unit of measure: Hertz) |
| INT lcUpsNominalInputVoltage | 1.3.6.1.4.1.476.1.1.1.1.9.2 | INTEGER | read-write | The nominal input voltage. (Unit of measure: volt) |
| INT lcUpsNominalOutputFreq | 1.3.6.1.4.1.476.1.1.1.1.9.5 | INTEGER | read-write | The nominal output frequency. (Unit of measure: Hertz) |
| INT lcUpsNominalOutputVA | 1.3.6.1.4.1.476.1.1.1.1.9.3 | INTEGER | read-write | The nominal Volt-Amp rating. |
| INT lcUpsNominalOutputVaRating | 1.3.6.1.4.1.476.1.1.1.1.9.7 | INTEGER | read-write | The nominal Volt-Amp rating. |
| INT lcUpsNominalOutputVoltage | 1.3.6.1.4.1.476.1.1.1.1.9.1 | INTEGER | read-write | The nominal output voltage. (Unit of measure: volt) |
| INT lcUpsNominalOutputWatts | 1.3.6.1.4.1.476.1.1.1.1.9.4 | INTEGER | read-write | The nominal power rating. (Unit of measure: watt) |
| INT lcUpsNominalOutputWattsRating | 1.3.6.1.4.1.476.1.1.1.1.9.8 | INTEGER | read-write | The nominal power rating. (Unit of measure: watt) |
| NTF lcUpsOnBatteryTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.3 | An lcUpsOnBatteryTrap signifies that the UPS is currently on Battery Power. | ||
| INT lcUpsOnBypass | 1.3.6.1.4.1.476.1.1.1.1.13.1 | INTEGER | read-only | Indicates that the UPS is currently on bypass. |
| lcUpsOutput | 1.3.6.1.4.1.476.1.1.1.1.4 | |||
| INT lcUpsOutputCurrent | 1.3.6.1.4.1.476.1.1.1.1.4.4.1.3 | INTEGER | read-only | The output current. (Unit of measure: Amp) |
| lcUpsOutputEntry | 1.3.6.1.4.1.476.1.1.1.1.4.4.1 | not-accessible | ||
| INT lcUpsOutputFrequency | 1.3.6.1.4.1.476.1.1.1.1.4.1 | INTEGER | read-only | The current output frequency. (Unit of measure: Hertz) |
| INT lcUpsOutputLine | 1.3.6.1.4.1.476.1.1.1.1.4.4.1.1 | INTEGER | read-only | The output Line. |
| INT lcUpsOutputLoad | 1.3.6.1.4.1.476.1.1.1.1.4.2 | INTEGER | read-only | The current output load percentage. |
| INT lcUpsOutputNumLines | 1.3.6.1.4.1.476.1.1.1.1.4.3 | INTEGER | read-only | The number of output lines utilized in this device. This entry indicates the number of rows in the output table. |
| NTF lcUpsOutputOffTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.12 | An lcUpsOutputOffTrap is sent when the UPS turns all of its output off, either at the inverter or via a relay. | ||
| NTF lcUpsOutputOffWarningTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.13 | An lcUpsOutputOffWarningTrap is sent when the lcUpsControlOutputOffDelay reaches the value of lcUpsControlOutputOffTrapDelay. | ||
| NTF lcUpsOutputOnTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.14 | An lcUpsOutputOnTrap is sent when the UPS turns all of its output back on, either at the inverter or via a relay. | ||
| NTF lcUpsOutputOnWarningTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.15 | An lcUpsOutputOnWarningTrap is sent when the lcUpsControlOutputOnDelay reaches the value of lcUpsControlOutputOnTrapDelay. | ||
| NTF lcUpsOutputOverVoltageTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.24 | An lcUpsOutputOverVoltageTrap signifies that the UPS has detected that the output voltage is too high. | ||
| lcUpsOutputTable | 1.3.6.1.4.1.476.1.1.1.1.4.4 | not-accessible | ||
| INT lcUpsOutputVA | 1.3.6.1.4.1.476.1.1.1.1.4.4.1.4 | INTEGER | read-only | The output volt-amps. |
| INT lcUpsOutputVoltage | 1.3.6.1.4.1.476.1.1.1.1.4.4.1.2 | INTEGER | read-only | The output voltage. (Unit of measure: Volt) |
| INT lcUpsOutputWatts | 1.3.6.1.4.1.476.1.1.1.1.4.5 | INTEGER | read-only | The output power in watts. |
| NTF lcUpsOverloadShutdownTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.2 | An lcUpsOverloadShutdownTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity and has shut off the output. | ||
| NTF lcUpsOverloadWarningTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.1 | An lcUpsOverloadWarningTrap signifies that the UPS has detected an Overload condition where the output load has exceeded the UPS's rated capacity. | ||
| NTF lcUpsOverTempShutdownTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.10 | An lcUpsOverTempShutdownTrap signifies that the UPS has detected a excessive temperature condition and shut off the output. | ||
| NTF lcUpsOverTempWarningTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.9 | An lcUpsOverTempWarningTrap signifies that the UPS has detected a excessive temperature condition. | ||
| NTF lcUpsPhaseRotationErrorTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.29 | An lcUpsPhaseRotationErrorTrap signifies a phase-rotation error in the bypass power. | ||
| NTF lcUpsReceptOffTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.18 | An lcUpsReceptOffTrap is sent when the UPS turns an output receptacle off. | ||
| NTF lcUpsReceptOffWarningTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.19 | An lcUpsReceptOffWarningTrap is sent when the lcUpsSwitchedReceptOffDelay reaches the value of lcUpsSwitchedReceptOffTrapDelay. | ||
| NTF lcUpsReceptOnTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.20 | An lcUpsReceptOnTrap is sent when the UPS turns an output receptacle on. | ||
| NTF lcUpsReceptOnWarningTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.21 | An lcUpsReceptOnWarningTrap is sent when the lcUpsSwitchedReceptOnDelay reaches the value of lcUpsSwitchedReceptOnTrapDelay. | ||
| NTF lcUpsReversePowerTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.28 | An lcUpsReversePowerTrap signifies that output has been shut off due to a reverse power flow condition. | ||
| lcUpsSwitchedReceptacles | 1.3.6.1.4.1.476.1.1.1.1.12 | |||
| lcUpsSwitchedReceptEntry | 1.3.6.1.4.1.476.1.1.1.1.12.2.1 | not-accessible | ||
| INT lcUpsSwitchedReceptIndex | 1.3.6.1.4.1.476.1.1.1.1.12.2.1.1 | INTEGER | read-only | |
| STR lcUpsSwitchedReceptLabel | 1.3.6.1.4.1.476.1.1.1.1.12.2.1.7 | DisplayString | read-write | A user-defined text string associated with a switched receptacle. This may be used to describe the load powered from the receptacle. The text string is stored in non-volatile memory. |
| INT lcUpsSwitchedReceptMaxNum | 1.3.6.1.4.1.476.1.1.1.1.12.1 | INTEGER | read-only | The maximum number of switched receptacles supported by the Ups. |
| INT lcUpsSwitchedReceptOffDelay | 1.3.6.1.4.1.476.1.1.1.1.12.2.1.4 | INTEGER | read-write | Setting this object causes the agent to instruct the UPS to turn off a receptacle after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsReceptOffTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsSwitchedCancelCommand to the value cancel. |
| INT lcUpsSwitchedReceptOffTrapDelay | 1.3.6.1.4.1.476.1.1.1.1.12.2.1.5 | INTEGER | read-write | When 'lcUpsSwitchedReceptOffDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOffWarningTrap will be produced and this object will be reset to 0. |
| INT lcUpsSwitchedReceptOnDelay | 1.3.6.1.4.1.476.1.1.1.1.12.2.1.2 | INTEGER | read-write | Setting this object causes the agent to instruct the UPS to turn on a receptacle after the indicated number of seconds. The agent counts down the number of seconds until the event will take place. The agent issues an lcUpsReceptOnTrap when the countdown finishes. Note that different models have different clock resolutions, usually greater than 1 second. As a result, the command will only be accurate to the resolution of the UPS's clock. The command can be cancelled by setting lcUpsSwitchedCancelCommand to the value cancel. |
| INT lcUpsSwitchedReceptOnTrapDelay | 1.3.6.1.4.1.476.1.1.1.1.12.2.1.3 | INTEGER | read-write | When 'lcUpsSwitchedReceptOnDelay' reaches a value less than or equal to this object's value, an lcUpsReceptOnWarningTrap will be produced and this object will be reset to 0. |
| INT lcUpsSwitchedReceptStatus | 1.3.6.1.4.1.476.1.1.1.1.12.2.1.6 | INTEGER | read-only | The status of the device receptacle. Note that some devices may support Switched of device receptacles as a group only (by using lcUpsSwitchedOutputOffDelay and lcUpsSwitchedOutputOnDelay). |
| lcUpsSwitchedReceptTable | 1.3.6.1.4.1.476.1.1.1.1.12.2 | not-accessible | ||
| lcUpsTest | 1.3.6.1.4.1.476.1.1.1.1.7 | |||
| INT lcUpsTestBattery | 1.3.6.1.4.1.476.1.1.1.1.7.1 | INTEGER | read-write | Setting this variable to 'start' will initiate the battery test. Setting this variable to 'abort' will stop the battery test if the test is in- progress, otherwise it has no effect. Setting this variable to 'unknown' has no effect. Reading this variable will always result in a return value of 'unknown'. If 'lcUpsTestBatteryStatus' is 'failed' the test may not be performed again and the status will remain in the failure state. |
| INT lcUpsTestBatteryStatus | 1.3.6.1.4.1.476.1.1.1.1.7.2 | INTEGER | read-only | The status of the battery test. |
| INT lcUpsTestDiag | 1.3.6.1.4.1.476.1.1.1.1.7.3 | INTEGER | read-write | Setting this variable to 'start' will initiate the diagnostics test. Setting this variable to 'abort' will stop the diagnostics test if the test is in-progress, otherwise it has no effect. Setting this variable to 'unknown' has no effect. Reading this variable will always result in a return value of 'unknown'. |
| INT lcUpsTestDiagStatus | 1.3.6.1.4.1.476.1.1.1.1.7.4 | INTEGER | read-only | The status of the diagnostics test. |
| lcUpsTraps | 1.3.6.1.4.1.476.1.1.1.1.11 | |||
| NTF lcUpsUnixShutdownTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.16 | An lcUpsUnixShutodwnTrap is sent 2 seconds before the UPS is scheduled to perform a Unix Shutdown. | ||
| NTF lcUpsUnixShutdownWarningTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.17 | An lcUpsUnixShutdownWarningTrap is sent when the lcUpsControlUnixShudownDelay reaches the value of lcUpsControlUnixShutdownTrapDelay. | ||
| NTF lcUpsUtilPowerFailedTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.6 | An lcUpsUtilPowerFailedTrap signifies that the utility power input to the UPS has been lost. | ||
| NTF lcUpsUtilPowerRestoredTrap | 1.3.6.1.4.1.476.1.1.1.1.11.0.7 | An lcUpsUtilPowerRestoredTrap signifies that the utility power has been restored to the UPS. | ||
| ldUpsAlarm | 1.3.6.1.4.1.476.1.1.1.3.6 | |||
| ldUpsAlarmBoostOn | 1.3.6.1.4.1.476.1.1.1.3.6.1.6 | |||
| ldUpsAlarmChargerFailed | 1.3.6.1.4.1.476.1.1.1.3.6.1.10 | |||
| ldUpsAlarmConditions | 1.3.6.1.4.1.476.1.1.1.3.6.1 | |||
| ldUpsAlarmDCOverVoltageShutdown | 1.3.6.1.4.1.476.1.1.1.3.6.1.1 | |||
| ldUpsAlarmImminentShutdown | 1.3.6.1.4.1.476.1.1.1.3.6.1.4 | |||
| ldUpsAlarmInputFreqError | 1.3.6.1.4.1.476.1.1.1.3.6.1.5 | |||
| ldUpsAlarmLNReversedShutdown | 1.3.6.1.4.1.476.1.1.1.3.6.1.3 | |||
| ldUpsAlarmOutputOverVoltage | 1.3.6.1.4.1.476.1.1.1.3.6.1.8 | |||
| ldUpsAlarmOutputShortShutdown | 1.3.6.1.4.1.476.1.1.1.3.6.1.2 | |||
| ldUpsAlarmOutputUnderVoltage | 1.3.6.1.4.1.476.1.1.1.3.6.1.9 | |||
| ldUpsAlarmReplaceBattery | 1.3.6.1.4.1.476.1.1.1.3.6.1.7 | |||
| NTF ldUpsChargerFailedTrap | 1.3.6.1.4.1.476.1.1.1.3.11.0.8 | An ldUpsChargerFailedTrap signifies that the UPS has detected that the battery charger has failed. | ||
| NTF ldUpsDCOverVoltageShutdownTrap | 1.3.6.1.4.1.476.1.1.1.3.11.0.1 | An ldUpsDCOverVoltageShutdownTrap signifies that the UPS has detected that battery voltage is over the tolarable level. | ||
| NTF ldUpsImminentShutdownTrap | 1.3.6.1.4.1.476.1.1.1.3.11.0.4 | An ldUpsImminentShutdownTrap signifies that the UPS is about to turn off output power. | ||
| ldUpsInput | 1.3.6.1.4.1.476.1.1.1.3.3 | |||
| NTF ldUpsInputFreqErrorTrap | 1.3.6.1.4.1.476.1.1.1.3.11.0.5 | An ldUpsInputFreqErrorTrap signifies that the UPS has detected that input frequency is outside tolerable variance. | ||
| INT ldUpsInputMaxVoltsSinceLastPoll | 1.3.6.1.4.1.476.1.1.1.3.3.1 | INTEGER | read-only | The maximum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated. |
| INT ldUpsInputMinVoltsSinceLastPoll | 1.3.6.1.4.1.476.1.1.1.3.3.2 | INTEGER | read-only | The minimum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated. |
| NTF ldUpsLNReversedShutdownTrap | 1.3.6.1.4.1.476.1.1.1.3.11.0.3 | An ldUpsLNReversedShutdownTrap signifies that the UPS has detected that Line and Neutral have been reversed. | ||
| ldUpsOutput | 1.3.6.1.4.1.476.1.1.1.3.4 | |||
| INT ldUpsOutputMaxVoltsSinceLastPoll | 1.3.6.1.4.1.476.1.1.1.3.4.1 | INTEGER | read-only | The maximum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated. |
| INT ldUpsOutputMinVoltsSinceLastPoll | 1.3.6.1.4.1.476.1.1.1.3.4.2 | INTEGER | read-only | The minimum output voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated. |
| NTF ldUpsOutputOverVoltageTrap | 1.3.6.1.4.1.476.1.1.1.3.11.0.6 | An ldUpsOutputOverVoltageTrap signifies that the UPS has detected that the output voltage is too high. | ||
| NTF ldUpsOutputShortShutdownTrap | 1.3.6.1.4.1.476.1.1.1.3.11.0.2 | An ldUpsOutputShortShutdownTrap signifies that the UPS has detected a short circuit across the output. | ||
| NTF ldUpsOutputUnderVoltageTrap | 1.3.6.1.4.1.476.1.1.1.3.11.0.7 | An ldUpsOutputUnderVoltageTrap signifies that the UPS has detected that the output voltage is too low. | ||
| ldUpsTraps | 1.3.6.1.4.1.476.1.1.1.3.11 | |||
| lgUpsAlarm | 1.3.6.1.4.1.476.1.1.1.4.6 | |||
| lgUpsAlarmConditions | 1.3.6.1.4.1.476.1.1.1.4.6.1 | |||
| lgUpsAlarmDCOverVoltageShutdown | 1.3.6.1.4.1.476.1.1.1.4.6.1.1 | |||
| lgUpsAlarmInputUVOnStartup | 1.3.6.1.4.1.476.1.1.1.4.6.1.5 | |||
| lgUpsAlarmLNReversedShutdown | 1.3.6.1.4.1.476.1.1.1.4.6.1.3 | |||
| lgUpsAlarmOutputShortShutdown | 1.3.6.1.4.1.476.1.1.1.4.6.1.2 | |||
| lgUpsAlarmPFCFailedOnStartup | 1.3.6.1.4.1.476.1.1.1.4.6.1.6 | |||
| lgUpsAlarmRemoteShutdown | 1.3.6.1.4.1.476.1.1.1.4.6.1.4 | |||
| NTF lgUpsDCOverVoltageShutdownTrap | 1.3.6.1.4.1.476.1.1.1.4.11.0.1 | An lgUpsDCOverVoltageShutdownTrap signifies that the UPS has detected that battery voltage is over the nominal level. | ||
| NTF lgUpsInputUVOnStartupTrap | 1.3.6.1.4.1.476.1.1.1.4.11.0.4 | An lgUpsInputUVOnStartupTrap signifies that the UPS detected a low voltage condition upon system startup. | ||
| NTF lgUpsLNReversedShutdownTrap | 1.3.6.1.4.1.476.1.1.1.4.11.0.3 | An lgUpsLNReversedShutdownTrap signifies that the UPS has detected that Line and Neutral have been reversed. | ||
| NTF lgUpsOutputShortShutdownTrap | 1.3.6.1.4.1.476.1.1.1.4.11.0.2 | An lgUpsOutputShortShutdownTrap signifies that the UPS has detected a short circuit across the output. | ||
| lgUpsTraps | 1.3.6.1.4.1.476.1.1.1.4.11 | |||
| liebertCorp | 1.3.6.1.4.1.476.1 | |||
| liebertUps | 1.3.6.1.4.1.476.1.1 | |||
| ls43cUpsBypass | 1.3.6.1.4.1.476.1.1.1.10.13 | |||
| INT ls43cUpsBypassCurrent | 1.3.6.1.4.1.476.1.1.1.10.13.4.1.3 | INTEGER | read-only | The bypass current. (Unit of measure: Amp) |
| ls43cUpsBypassEntry | 1.3.6.1.4.1.476.1.1.1.10.13.4.1 | not-accessible | ||
| INT ls43cUpsBypassFrequency | 1.3.6.1.4.1.476.1.1.1.10.13.2 | INTEGER | read-only | The current bypass frequency. (Unit of measure: Hertz) |
| INT ls43cUpsBypassLine | 1.3.6.1.4.1.476.1.1.1.10.13.4.1.1 | INTEGER | read-only | The bypass Line. |
| INT ls43cUpsBypassNumLines | 1.3.6.1.4.1.476.1.1.1.10.13.3 | INTEGER | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. |
| ls43cUpsBypassTable | 1.3.6.1.4.1.476.1.1.1.10.13.4 | not-accessible | ||
| INT ls43cUpsBypassVoltage | 1.3.6.1.4.1.476.1.1.1.10.13.4.1.2 | INTEGER | read-only | The bypass voltage. (Unit of measure: Volt) |
| ls43cUpsConfig | 1.3.6.1.4.1.476.1.1.1.10.12 | |||
| INT ls43cUpsConfigBypassInstalled | 1.3.6.1.4.1.476.1.1.1.10.12.1 | INTEGER | read-only | Indicates if a bypass is installed in the UPS. |
| ls43cUpsIdent | 1.3.6.1.4.1.476.1.1.1.10.1 | |||
| STR ls43cUpsIdentFirmwareVersion | 1.3.6.1.4.1.476.1.1.1.10.1.1 | DisplayString | read-only | The firmware revision level of the UPS. |
| INT ls43cUpsOnBypass | 1.3.6.1.4.1.476.1.1.1.10.13.1 | INTEGER | read-only | Indicates that the UPS is currently on bypass. |
| lsUpsAlarm | 1.3.6.1.4.1.476.1.1.1.2.6 | |||
| lsUpsAlarmCheckAirFilter | 1.3.6.1.4.1.476.1.1.1.2.6.1.1 | |||
| lsUpsAlarmConditions | 1.3.6.1.4.1.476.1.1.1.2.6.1 | |||
| lsUpsBypass | 1.3.6.1.4.1.476.1.1.1.2.13 | |||
| INT lsUpsBypassCurrent | 1.3.6.1.4.1.476.1.1.1.2.13.4.1.3 | INTEGER | read-only | The bypass current. (Unit of measure: Amp) |
| lsUpsBypassEntry | 1.3.6.1.4.1.476.1.1.1.2.13.4.1 | not-accessible | ||
| INT lsUpsBypassFrequency | 1.3.6.1.4.1.476.1.1.1.2.13.2 | INTEGER | read-only | The current bypass frequency. (Unit of measure: Hertz) |
| INT lsUpsBypassLine | 1.3.6.1.4.1.476.1.1.1.2.13.4.1.1 | INTEGER | read-only | The bypass Line. |
| INT lsUpsBypassNumLines | 1.3.6.1.4.1.476.1.1.1.2.13.3 | INTEGER | read-only | The number of bypass lines utilized in this device. This entry indicates the number of rows in the bypass table. |
| lsUpsBypassTable | 1.3.6.1.4.1.476.1.1.1.2.13.4 | not-accessible | ||
| INT lsUpsBypassVoltage | 1.3.6.1.4.1.476.1.1.1.2.13.4.1.2 | INTEGER | read-only | The bypass voltage. (Unit of measure: Volt) |
| NTF lsUpsCheckAirFilterTrap | 1.3.6.1.4.1.476.1.1.1.2.11.0.1 | An lsUpsCheckAirFilterTrap signifies that the programmed time interval for checking the air filter has passed and it is time to check the air filter. | ||
| lsUpsConfig | 1.3.6.1.4.1.476.1.1.1.2.12 | |||
| INT lsUpsConfigBypassInstalled | 1.3.6.1.4.1.476.1.1.1.2.12.1 | INTEGER | read-only | Indicates if a bypass is installed in the UPS. |
| lsUpsIdent | 1.3.6.1.4.1.476.1.1.1.2.1 | |||
| STR lsUpsIdentFirmwareVersion | 1.3.6.1.4.1.476.1.1.1.2.1.1 | DisplayString | read-only | The firmware revision level of the UPS. |
| INT lsUpsOnBypass | 1.3.6.1.4.1.476.1.1.1.2.13.1 | INTEGER | read-only | Indicates that the UPS is currently on bypass. |
| lsUpsTraps | 1.3.6.1.4.1.476.1.1.1.2.11 | |||
| luCore | 1.3.6.1.4.1.476.1.1.1.1 | |||
| luExperimental | 1.3.6.1.4.1.476.1.1.2 | |||
| luExtensions | 1.3.6.1.4.1.476.1.1.1 | |||
| luExternal | 1.3.6.1.4.1.476.1.1.1.6 | |||
| luPowerSure | 1.3.6.1.4.1.476.1.1.1.15 | |||
| luPrivate | 1.3.6.1.4.1.476.1.1.3 | |||
| luSeries200 | 1.3.6.1.4.1.476.1.1.1.8 | |||
| luSeries200Alarm | 1.3.6.1.4.1.476.1.1.1.8.6 | |||
| luSeries200AlarmConditions | 1.3.6.1.4.1.476.1.1.1.8.6.1 | |||
| luSeries200AlarmInputFreqError | 1.3.6.1.4.1.476.1.1.1.8.6.1.1 | |||
| luSeries200Bypass | 1.3.6.1.4.1.476.1.1.1.8.13 | |||
| luSeries200Config | 1.3.6.1.4.1.476.1.1.1.8.12 | |||
| INT luSeries200ConfigBypassInstalled | 1.3.6.1.4.1.476.1.1.1.8.12.1 | INTEGER | read-only | Indicates if a bypass is installed in the UPS. |
| INT luSeries200ConfigFrequencyChangerModel | 1.3.6.1.4.1.476.1.1.1.8.12.2 | INTEGER | read-only | Indicates whether this AP200 model is a frequency changer model. |
| luSeries200Input | 1.3.6.1.4.1.476.1.1.1.8.3 | |||
| INT luSeries200InputMaxVoltsSinceLastPoll | 1.3.6.1.4.1.476.1.1.1.8.3.1 | INTEGER | read-only | The maximum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated. |
| INT luSeries200InputMinVoltsSinceLastPoll | 1.3.6.1.4.1.476.1.1.1.8.3.2 | INTEGER | read-only | The minimum input voltage encountered since the object was last retrieved. Note: if there are multiple managers talking to the same agent, the use of this object needs to be coordinated. |
| INT luSeries200OnBypass | 1.3.6.1.4.1.476.1.1.1.8.13.1 | INTEGER | read-only | Indicates that the UPS is currently on bypass. |
| luSeries300 | 1.3.6.1.4.1.476.1.1.1.5 | |||
| luSeries4300 | 1.3.6.1.4.1.476.1.1.1.10 | |||
| luSystemCabinet | 1.3.6.1.4.1.476.1.1.1.12 | |||
| luUpsModule | 1.3.6.1.4.1.476.1.1.1.11 | |||
| luUPStationD | 1.3.6.1.4.1.476.1.1.1.3 | |||
| luUPStationG | 1.3.6.1.4.1.476.1.1.1.4 | |||
| luUPStationGxt | 1.3.6.1.4.1.476.1.1.1.14 | |||
| luUPStationS | 1.3.6.1.4.1.476.1.1.1.2 | |||
| luUPStationS3 | 1.3.6.1.4.1.476.1.1.1.7 |
RFC description
Manages Liebert UPS systems, providing monitoring and configuration of uninterruptible power supply devices and parameters.