All MIBs › LIEBERT-GP-FLEXIBLE-MIB
Organization: Emerson Network Power/Liebert Corporation
Last Updated: 2013-05-14
Category: Domain: Power/UPS, Vendor: Liebert
Description: Defines flexible monitoring and control objects for Emerson Network Power/Liebert GlobalProducts equipment including UPS and cooling systems.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is LIEBERT-GP-FLEXIBLE-MIB?
LIEBERT-GP-FLEXIBLE-MIB is a Liebert Corporation (Vertiv) SNMP module that registers a flexible, extensible set of monitoring and control objects for GlobalProducts equipment such as UPS systems and precision cooling units, allowing the same MIB structure to represent varying object sets across different product models. It exposes a basic table and an extended table of flexible objects, sized by a table count object, rather than a fixed enumerated set of named sensors. Its purpose is to support monitoring hardware status generically across a diverse Liebert product line: depending on the specific device, the flexible tables can carry readings such as battery status, load percentage, temperature, or alarm state, all surfaced through the same generic table structure. It is a companion module to LIEBERT-GP-AGENT-MIB, relying on that MIB's agent/device identification to know which physical device each flexible table entry belongs to. It is typically deployed in data center and facility environments running Liebert/Vertiv UPS or cooling equipment where the vendor's flexible object model accommodates model-specific variations without needing a new MIB per product. Network engineers evaluating or troubleshooting this functionality can download the LIEBERT-GP-FLEXIBLE-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in LIEBERT-GP-FLEXIBLE-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Liebert/Vertiv UPS unit
- Liebert/Vertiv precision cooling unit
Monitoring Examples
An administrator would poll lgpFlexibleTableCount to determine how many flexible monitoring rows are populated, then iterate lgpFlexibleBasicTable for basic status/reading values and lgpFlexibleExtendedTable for additional detail fields on the same device, since the actual sensor meaning depends on the specific Liebert product connected. Because the objects here are generic/flexible rather than named per sensor, the specific alarm interpretation must be cross-referenced with the vendor's documentation for that device model. A change in a flexible table row's status value would be the trigger that something on the underlying UPS or cooling unit needs attention.
What Can Be Monitored
- flexible monitoring table row count
- basic status/reading values (device-dependent)
- extended detail values (device-dependent)
Imported Objects
From LIEBERT-GP-REGISTRATION-MIB
| lgpFlexible | OBJECT-IDENTITY |
| liebertFlexibleModuleReg | OBJECT-IDENTITY |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString |
OIDs
RFC description
SNMP OID registration for Liebert flexible power and cooling monitoring in data center infrastructure management.
Start monitoring Liebert/Vertiv UPS or precision cooling unit (flexible generic object tables) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.