cienaCesChassisPowerOutputVoltageHealthMinThreshold

Module: CIENA-CES-CHASSIS-MIB

OID (symbolic): CIENA-CES-CHASSIS-MIB::cienaCesChassisPowerOutputVoltageHealthMinThreshold

OID (numeric): 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.7

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The minimum operational voltage of the Power Supply output voltage sub-category.

What is cienaCesChassisPowerOutputVoltageHealthMinThreshold?

This object holds the minimum acceptable output voltage, in millivolts, for the power supply. An admin uses this as the low-voltage alarm boundary; a reading falling below it indicates the supply may be failing to maintain its rated output under load. For example, a MinThreshold of 11500 mV tripped by a CurrMeasurement of 11200 mV would flag that supply for replacement before it fails outright.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.7
snmpwalk -v2c -c public <target> CIENA-CES-CHASSIS-MIB::cienaCesChassisPowerOutputVoltageHealthMinThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.7.1
snmpget -v2c -c public <target> CIENA-CES-CHASSIS-MIB::cienaCesChassisPowerOutputVoltageHealthMinThreshold.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-CHASSIS-MIB::cienaCesChassisPowerOutputVoltageHealthMinThreshold OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.5cienaCesChassisMIBCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1cienaCesChassisMIBObjectsCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2cienaCesChassisObjectsCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1cienaCesChassisCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1.4cienaCesChassisHealthCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37cienaCesChassisPowerOutputVoltageHealthTableCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1cienaCesChassisPowerOutputVoltageHealthEntryCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1.4.37.1.7cienaCesChassisPowerOutputVoltageHealthMinThresholdCIENA-CES-CHASSIS-MIB