All MIBs › CIENA-CES-CHASSIS-MIB › cienaCesChassisFanTempHealthMaxThreshold
cienaCesChassisFanTempHealthMaxThreshold
Module: CIENA-CES-CHASSIS-MIB
OID (symbolic): CIENA-CES-CHASSIS-MIB::cienaCesChassisFanTempHealthMaxThreshold
OID (numeric): 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.8
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-only
Description: The maximum operational temperature for the fan temperature sensor.
What is cienaCesChassisFanTempHealthMaxThreshold?
This object holds the configured maximum operational temperature for the fan temperature sensor, the trip point the Health Manager checks the current reading against. An admin uses this value to know how much thermal margin the fan environment has left before that sensor is flagged unhealthy. For example, a MaxThreshold of 55 with readings hovering at 52 leaves only a small buffer before an alarm.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.8 snmpwalk -v2c -c public <target> CIENA-CES-CHASSIS-MIB::cienaCesChassisFanTempHealthMaxThreshold
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.8.1 snmpget -v2c -c public <target> CIENA-CES-CHASSIS-MIB::cienaCesChassisFanTempHealthMaxThreshold.1
Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-CHASSIS-MIB::cienaCesChassisFanTempHealthMaxThreshold OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.1271 | ciena | CIENA-SMI |
| 1.3.6.1.4.1.1271.2 | cienaCes | CIENA-SMI |
| 1.3.6.1.4.1.1271.2.1 | cienaCesConfig | CIENA-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.1271.2.1.5 | cienaCesChassisMIB | CIENA-CES-CHASSIS-MIB |
| 1.3.6.1.4.1.1271.2.1.5.1 | cienaCesChassisMIBObjects | CIENA-CES-CHASSIS-MIB |
| 1.3.6.1.4.1.1271.2.1.5.1.2 | cienaCesChassisObjects | CIENA-CES-CHASSIS-MIB |
| 1.3.6.1.4.1.1271.2.1.5.1.2.1 | cienaCesChassis | CIENA-CES-CHASSIS-MIB |
| 1.3.6.1.4.1.1271.2.1.5.1.2.1.4 | cienaCesChassisHealth | CIENA-CES-CHASSIS-MIB |
| 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18 | cienaCesChassisFanTempHealthTable | CIENA-CES-CHASSIS-MIB |
| 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1 | cienaCesChassisFanTempHealthEntry | CIENA-CES-CHASSIS-MIB |
| 1.3.6.1.4.1.1271.2.1.5.1.2.1.4.18.1.8 | cienaCesChassisFanTempHealthMaxThreshold | CIENA-CES-CHASSIS-MIB |