CIENA-CES-CHASSIS-MIB :: cienaCesChassisPowerSupplySlotName

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsCIENA-CES-CHASSIS-MIBcienaCesChassisPowerSupplySlotName

cienaCesChassisPowerSupplySlotName

Module: CIENA-CES-CHASSIS-MIB

OID (symbolic): CIENA-CES-CHASSIS-MIB::cienaCesChassisPowerSupplySlotName

OID (numeric): 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.9

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: Specifies the name of the chassis slot in which the power supply is installed.

What is cienaCesChassisPowerSupplySlotName?

This holds the human-readable name, rather than just a numeric index, of the physical slot bay that a given power supply occupies, letting an admin match an SNMP-reported value directly to a label silkscreened on the chassis itself when physically walking up to service a failed unit. This is the difference between an alarm ticket that says to check power supply index 2 and one that says to check slot PS-B, the latter being far faster to act on in a dark data-center aisle.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.9
snmpwalk -v2c -c public <target> CIENA-CES-CHASSIS-MIB::cienaCesChassisPowerSupplySlotName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.9.1
snmpget -v2c -c public <target> CIENA-CES-CHASSIS-MIB::cienaCesChassisPowerSupplySlotName.1

Start monitoring Ciena CES (Carrier Ethernet Switch) platforms with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CIENA-CES-CHASSIS-MIB::cienaCesChassisPowerSupplySlotName OID value, configure state conditions and alerts, and monitor any Ciena CES (Carrier Ethernet Switch) platforms from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.1271cienaCIENA-SMI
1.3.6.1.4.1.1271.2cienaCesCIENA-SMI
1.3.6.1.4.1.1271.2.1cienaCesConfigCIENA-SMI
Numeric OIDNameModule
1.3.6.1.4.1.1271.2.1.5cienaCesChassisMIBCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1cienaCesChassisMIBObjectsCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2cienaCesChassisObjectsCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1cienaCesChassisCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1.1cienaCesChassisPowerModuleCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1cienaCesChassisPowerTableCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1cienaCesChassisPowerEntryCIENA-CES-CHASSIS-MIB
1.3.6.1.4.1.1271.2.1.5.1.2.1.1.1.1.9cienaCesChassisPowerSupplySlotNameCIENA-CES-CHASSIS-MIB