LIEBERT-GP-POWER-MIB

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-POWER-MIB

Organization: Liebert Corporation

Last Updated: 2013-07-10

Category: Domain: Power/UPS, Vendor: Liebert

Description: Defines power measurement and management objects for Liebert GlobalProducts UPS, PDU, and power conditioning equipment.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is LIEBERT-GP-POWER-MIB?

This is a Liebert (Vertiv) private MIB covering power-related objects across Liebert's GlobalProducts UPS, PDU, and power-conditioning equipment line, used in data center and facility power management. It exposes hardware health and configuration data centered on battery subsystems: counts of installed, failed, redundant, and active battery modules, battery test results, nominal capacity, float voltage, end-of-discharge voltage, and configurable warning thresholds like low-battery warning time and automatic test interval. Its monitoring purpose is explicitly hardware status monitoring for UPS battery backup health, catching failed battery modules before a utility outage exposes the shortfall, tracking battery test results to confirm the UPS can actually deliver its rated runtime, and using module warning counts as an early alert that battery capacity is degrading. It is a Liebert-specific MIB not built on a shared IETF power standard, though it parallels the general intent of the standards-based UPS-MIB (RFC 1628). It is deployed on Liebert/Vertiv UPS systems, PDUs, and battery cabinets protecting data center and critical-facility power infrastructure. Engineers can download the LIEBERT-GP-POWER-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in LIEBERT-GP-POWER-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Liebert/Vertiv UPS system
  • Liebert/Vertiv PDU and power-conditioning equipment

Monitoring Examples

An administrator would poll lgpPwrNumberInstalledBatteryModules against lgpPwrNumberFailedBatteryModules to compute how many battery modules are currently down, and check lgpPwrNumberRedundantBatteryModules versus lgpPwrNumberActiveBatteryModules to confirm the UPS still has its designed redundancy. lgpPwrBatteryTestResult would be checked after a scheduled self-test, governed by lgpPwrAutomaticBatteryTestInterval, to verify the battery bank actually passed, while lgpPwrBatteryFloatVoltage and lgpPwrBatteryEndOfDischargeVoltage give the electrical parameters used to judge battery health. A rising lgpPwrNumberBatteryModuleWarnings count alongside a falling active-module count would be a clear signal of imminent runtime-capacity loss.

What Can Be Monitored

  • installed/failed/active/redundant battery module counts
  • battery self-test result
  • battery float voltage
  • battery end-of-discharge voltage
  • automatic battery test interval
  • low-battery warning time threshold
Imported Objects

From LIEBERT-GP-REGISTRATION-MIB

lgpPowerOBJECT-IDENTITY
liebertPowerModuleRegOBJECT-IDENTITY

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
OBJECT-IDENTITY
OBJECT-TYPE
Unsigned32
OIDs

RFC description

Liebert power management MIB for UPS, battery, and power monitoring in data center infrastructure.

Start monitoring Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download LIEBERT-GP-POWER-MIB