All MIBs › ELTEK-GENERIC-MIB
Category: Domain: Power/UPS, Vendor: Eltek
Description: Eltek generic MIB providing common management objects applicable across the Eltek range of power management products.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is ELTEK-GENERIC-MIB?
ELTEK-GENERIC-MIB is a vendor-specific MIB from Eltek providing common management objects shared across Eltek's DC power management and rectifier/controller product range, under the eltekPlant and controlSystem enterprise branches. It exposes system time (for event timestamping and log correlation), site identification data such as customer, location, install date, and controller/system serial numbers, plus trap notification settings. This supports monitoring the software status of the power system controller's management agent, tracking whether its clock is correct for accurate alarm timestamps and whether trap notification/repeat behavior is properly configured so alarms aren't silently dropped. It serves as the generic base underlying Eltek's broader power management MIB family, used alongside more specific Eltek MIBs that expose actual rectifier/battery telemetry. It is typically deployed on DC power plant controllers monitoring telecom or data center power systems. Network engineers evaluating or troubleshooting this functionality can download the ELTEK-GENERIC-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in ELTEK-GENERIC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Eltek DC power system controller (rectifier/power plant controller)
Monitoring Examples
Polling systemTimeTime confirms the controller's clock, critical for correlating alarm timestamps in event logs, while systemSiteInfoControllerType, systemSiteInfoSystemSeriaNum, and systemSiteInfoControllerSeriaNum let an operator confirm which physical controller and site (systemSiteInfoCustomer, systemSiteInfoLocation) a given SNMP agent corresponds to across a fleet of power plants. systemSendOffTrap and systemTrapRepeatRate govern whether and how often the device re-sends outstanding alarm traps, so an admin troubleshooting a missed alert would check whether trap repeating was disabled.
What Can Be Monitored
- system time/clock
- site and customer identification
- controller and system serial numbers
- installed date
- trap repeat rate and notification enable
This MIB depends on
Related MIBs
Imported Objects
From ELTEK-COMMON-MIB
| eltek | MODULE-IDENTITY |
From SNMPv2-CONF
| NOTIFICATION-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE | |
| enterprises | |
| mib-2 |
From SNMPv2-TC
| DisplayString |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| eltekPlant | 1.3.6.1.4.1.12148.7 | |||
| controlSystem | 1.3.6.1.4.1.12148.7.1 | |||
| systemTime | 1.3.6.1.4.1.12148.7.1.1 | |||
| STR systemTimeTime | 1.3.6.1.4.1.12148.7.1.1.1 | DisplayString | read-only | The system date and time. Used for event timestamps and logging |
| INT systemInfoRefresh | 1.3.6.1.4.1.12148.7.1.2 | INTEGER | read-write | This object will re-initialize the agent, updating MIB data values. |
| I32 systemTrapRepeatRate | 1.3.6.1.4.1.12148.7.1.3 | Integer32 | read-write | This object sets the repeat rate of any active traps, in seconds. Entering 0 (zero) will prevent repeating traps - one trap only will be sent per alarm event. |
| INT systemSendOffTrap | 1.3.6.1.4.1.12148.7.1.4 | INTEGER | read-write | A separate off-trap will be issued when an alarm condition goes off, if this flag is set to 1. Entering 0 (zero) will prevent OFF traps from being transmitted. |
| dcSystem | 1.3.6.1.4.1.12148.7.2 | |||
| dcPlant | 1.3.6.1.4.1.12148.7.2.1 | |||
| systemSiteInfo | 1.3.6.1.4.1.12148.7.2.1.3 | |||
| STR systemSiteInfoCustomer | 1.3.6.1.4.1.12148.7.2.1.3.1 | DisplayString | read-only | The Customer name (as stored in the Smartpack Control Unit) |
| STR systemSiteInfoLocation | 1.3.6.1.4.1.12148.7.2.1.3.2 | DisplayString | read-only | The system/site Location details (as stored in the Smartpack Control Unit). |
| STR systemSiteInfoMessage1 | 1.3.6.1.4.1.12148.7.2.1.3.3 | DisplayString | read-only | The system/site Info Message record #1 (as stored in the Smartpack Control Unit). 31 Bytes. |
| STR systemSiteInfoMessage2 | 1.3.6.1.4.1.12148.7.2.1.3.4 | DisplayString | read-only | The system/site Info Message record #2 (as stored in the Smartpack Control Unit). 31 Bytes. |
| STR systemSiteInfoInstalledDate | 1.3.6.1.4.1.12148.7.2.1.3.5 | DisplayString | read-only | The system's Installed Date text string (as stored in the Smartpack Control Unit) 16bytes. |
| INT systemSiteInfoControllerType | 1.3.6.1.4.1.12148.7.2.1.3.6 | INTEGER | read-only | The system Controller Module currently connected. AL175/MCU=0; AEON Gold=1; AL6000=2; Smartpack=3 |
| STR systemSiteInfoSystemSeriaNum | 1.3.6.1.4.1.12148.7.2.1.3.7 | DisplayString | read-only | The serial number for the complete system |
| STR systemSiteInfoControllerSeriaNum | 1.3.6.1.4.1.12148.7.2.1.3.8 | DisplayString | read-only | The serial number for the system controller |
| INT systemNominalVoltage | 1.3.6.1.4.1.12148.7.2.1.4 | INTEGER | read-only | The nominal voltage rating. 12V/24V/48V/60V systems 0=48V 1=24V 2=12V 3=26V 4=60V |
| INT systemOperationalStatus | 1.3.6.1.4.1.12148.7.2.2 | INTEGER | read-only | A summary status showing if the system is testing, boosting, floating etc. 0=Float, voltage regulated 1=Float, temperature comp. regulated; 2=equalize 3=battery test |
| battery | 1.3.6.1.4.1.12148.7.3 | |||
| STR batteryName | 1.3.6.1.4.1.12148.7.3.1 | DisplayString | read-only | A descriptive name of the battery installed in the system |
| I32 batteryVoltage | 1.3.6.1.4.1.12148.7.3.2 | Integer32 | read-only | The measured battery voltage. |
| I32 batteryCurrent | 1.3.6.1.4.1.12148.7.3.3 | Integer32 | read-only | The measured battery current. |
| I32 batteryTemp | 1.3.6.1.4.1.12148.7.3.4 | Integer32 | read-only | The battery temperature |
| INT batteryBreakerStatus | 1.3.6.1.4.1.12148.7.3.5 | INTEGER | read-only | The state of the battery fuse/breaker can be either closed(0) or open(1) |
| INT batteryChargeCurrentLimitCtrl | 1.3.6.1.4.1.12148.7.3.6 | INTEGER | read-write | Control field for the battery charge limitation feature; 0=inactive, 1=active. |
| I32 batteryChargeCurrentLimitValue | 1.3.6.1.4.1.12148.7.3.7 | Integer32 | read-write | Battery charging current limit value |
| INT batteryTempCompEnable | 1.3.6.1.4.1.12148.7.3.8 | INTEGER | read-write | Enable (0) or Disable (1) Battery Temperature Compensated output regulation mode |
| I32 batteryFloatVoltConfig | 1.3.6.1.4.1.12148.7.3.9 | Integer32 | read-write | The Voltage at which the DC System float charges. |
| I32 batteryEqualizeVoltConfig | 1.3.6.1.4.1.12148.7.3.10 | Integer32 | read-write | The Voltage at which the DC System boost charges the batteries. |
| I32 batteryHighMajorAlarmVoltageConfig | 1.3.6.1.4.1.12148.7.3.11 | Integer32 | read-write | The High Battery Voltage alarm limit set voltage |
| I32 batteryHighMinorAlarmVoltageConfig | 1.3.6.1.4.1.12148.7.3.12 | Integer32 | read-write | The High Battery Voltage alarm limit set voltage |
| I32 batteryLowMajorAlarmVoltageConfig | 1.3.6.1.4.1.12148.7.3.13 | Integer32 | read-write | The Low Battery Voltage Alarm limit set voltage |
| I32 batteryLowMinorAlarmVoltageConfig | 1.3.6.1.4.1.12148.7.3.14 | Integer32 | read-write | The Very Low Battery Voltage Alarm limit set voltage |
| INT batteryStartManualTest | 1.3.6.1.4.1.12148.7.3.15 | INTEGER | read-write | This pushbutton will start a manual battery test if otherwise the system allows it. |
| INT batteryStartManualBoost | 1.3.6.1.4.1.12148.7.3.16 | INTEGER | read-write | This pushbutton will start a manual battery boost if otherwise the system allows it. |
| batteryLVD | 1.3.6.1.4.1.12148.7.3.17 | |||
| INT batteryLVDStatus | 1.3.6.1.4.1.12148.7.3.17.1 | INTEGER | read-only | Contactor is closed(0) or open(1) |
| I32 batteryLVDDisconnectVoltage | 1.3.6.1.4.1.12148.7.3.17.2 | Integer32 | read-write | The Contactor Disconnect Voltage |
| I32 batteryLVDConnectVoltage | 1.3.6.1.4.1.12148.7.3.17.3 | Integer32 | read-write | The Contactor Reconnect Voltage |
| batteryMidpoint | 1.3.6.1.4.1.12148.7.3.18 | |||
| I32 batteryMidpointDeltaLimitVoltage | 1.3.6.1.4.1.12148.7.3.18.1 | Integer32 | read-write | The allowable deviation of the midpoint battery voltage from the theoretical. Exceeding this value in either direction (+/-) causes an alarm state |
| I32 batteryMidpointIndex | 1.3.6.1.4.1.12148.7.3.18.2 | Integer32 | read-only | An index of Battery Strings, for the batteryMidpointControlTable and batteryMidpointStatusTable arrays |
| batteryMidpointControlTable | 1.3.6.1.4.1.12148.7.3.18.3 | not-accessible | A table of settings related to Battery Symmetry (midpoint) Monitoring | |
| batteryMidpointControlEntry | 1.3.6.1.4.1.12148.7.3.18.3.1 | not-accessible | Settings related to Battery Symmetry (midpoint) Monitoring, corresponding to the batteryMidpointIndex value | |
| I32 midpointEnableID | 1.3.6.1.4.1.12148.7.3.18.3.1.1 | Integer32 | read-only | The rectifier ID number of the rectifier record. |
| INT midpointEnable | 1.3.6.1.4.1.12148.7.3.18.3.1.2 | INTEGER | read-write | Enable (1) or Disable (0) the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| batteryMidpointStatusTable | 1.3.6.1.4.1.12148.7.3.18.4 | not-accessible | A table of values and/or measurements related to Battery Symmetry (midpoint) Monitoring | |
| batteryMidpointStatusEntry | 1.3.6.1.4.1.12148.7.3.18.4.1 | not-accessible | Values related to Battery Symmetry (midpoint) Monitoring, corresponding to the batteryMidpointIndex value | |
| I32 midpointStatusID | 1.3.6.1.4.1.12148.7.3.18.4.1.1 | Integer32 | read-only | The rectifier ID number of the rectifier record. |
| INT midpointStatus | 1.3.6.1.4.1.12148.7.3.18.4.1.2 | INTEGER | read-only | Status (0=Normal; 1=Alarm) of the Battery Monitor channel which corresponds to the batteryMidpointIndex value |
| I32 midpointDeltaVoltage | 1.3.6.1.4.1.12148.7.3.18.4.1.3 | Integer32 | read-only | The measured battery voltage deviation from midpoint of the Battery Monitor channel which corresponds to the batteryMidpointIndex value. |
| loadDistribution | 1.3.6.1.4.1.12148.7.4 | |||
| I32 loadDistributionCurrent | 1.3.6.1.4.1.12148.7.4.1 | Integer32 | read-only | The total load current |
| INT loadDistributionBreakerStatus | 1.3.6.1.4.1.12148.7.4.2 | INTEGER | read-only | The state of the load fuse/breaker can be either closed(0) or open(1) |
| loadDistributionLVDStatus | 1.3.6.1.4.1.12148.7.4.3 | |||
| INT loadLVD1EnableStatus | 1.3.6.1.4.1.12148.7.4.3.1 | INTEGER | read-only | The status of contactors configuration. 'enabled' means that the contactor is i n use. 'disabled' means that the contactor is disconfigured and not in use. |
| INT loadLVD1Status | 1.3.6.1.4.1.12148.7.4.3.2 | INTEGER | read-only | The A Bus (primary loads) Contactor is closed(0) or open(1) |
| I32 loadLVD1ConnectVoltage | 1.3.6.1.4.1.12148.7.4.3.3 | Integer32 | read-write | The A Bus (primary loads) Contactor Connect Voltage |
| I32 loadLVD1DisconnectVoltage | 1.3.6.1.4.1.12148.7.4.3.4 | Integer32 | read-write | The A Bus (primary loads) Contactor Disconnect Voltage |
| INT loadLVD2EnableStatus | 1.3.6.1.4.1.12148.7.4.3.5 | INTEGER | read-only | The status of contactors configuration. 'enabled' means that the contactor is i n use. 'disabled' means that the contactor is disconfigured and not in use. |
| INT loadLVD2Status | 1.3.6.1.4.1.12148.7.4.3.6 | INTEGER | read-only | The B Bus (secondary loads) Contactor is closed(0) or open(1) |
| I32 loadLVD2ConnectVoltage | 1.3.6.1.4.1.12148.7.4.3.7 | Integer32 | read-write | The B Bus (secondary loads) Contactor Connect Voltage |
| I32 loadLVD2DisconnectVoltage | 1.3.6.1.4.1.12148.7.4.3.8 | Integer32 | read-write | The B Bus (secondary loads) Contactor Disconnect Voltage |
| INT loadLVD3EnableStatus | 1.3.6.1.4.1.12148.7.4.3.9 | INTEGER | read-only | The status of contactors configuration. 'enabled' means that the contactor is i n use. 'disabled' means that the contactor is disconfigured and not in use. |
| INT loadLVD3Status | 1.3.6.1.4.1.12148.7.4.3.10 | INTEGER | read-only | The C Bus (critical loads) Contactor is closed(0) or open(1) |
| I32 loadLVD3ConnectVoltage | 1.3.6.1.4.1.12148.7.4.3.11 | Integer32 | read-write | The C Bus (critical loads) Contactor Connect Voltage |
| I32 loadLVD3DisconnectVoltage | 1.3.6.1.4.1.12148.7.4.3.12 | Integer32 | read-write | The C Bus (critical loads) Contactor Disconnect Voltage |
| rectifier | 1.3.6.1.4.1.12148.7.5 | |||
| I32 rectifierInstalledRectifiers | 1.3.6.1.4.1.12148.7.5.1 | Integer32 | read-only | The installed number of rectifiers for this DC Power System. |
| I32 rectifierRectifiersActive | 1.3.6.1.4.1.12148.7.5.2 | Integer32 | read-only | The actual number of active rectifiers in this DC Power System. |
| I32 rectifierTotalCurrent | 1.3.6.1.4.1.12148.7.5.3 | Integer32 | read-only | The DC system's total available current |
| I32 rectifierUtilization | 1.3.6.1.4.1.12148.7.5.4 | Integer32 | read-only | Utilization in % of available rectifier capacity |
| rectifierStatus | 1.3.6.1.4.1.12148.7.5.5 | |||
| I32 rectifierStatusNoIndex | 1.3.6.1.4.1.12148.7.5.5.1 | Integer32 | read-write | A starting index for the rectifierStatusTable array |
| rectifierStatusTable | 1.3.6.1.4.1.12148.7.5.5.2 | not-accessible | A table listing up to sixteen sequential recifiers, starting from the rectifier number specified by rectifierStatusNoIndex | |
| rectifierStatusEntry | 1.3.6.1.4.1.12148.7.5.5.2.1 | not-accessible | A row of rectifier status data corresponding to the rectifierStatusNoIndex value | |
| I32 rectifierStatusID | 1.3.6.1.4.1.12148.7.5.5.2.1.1 | Integer32 | read-only | The rectifier ID number of the rectifier record. |
| INT rectifierStatusStatus | 1.3.6.1.4.1.12148.7.5.5.2.1.2 | INTEGER | read-only | The operational status of the rectifier record. absent (0), active (1), failed (2), walkin (3), disabledbycommand (4) |
| I32 rectifierStatusOutputCurrent | 1.3.6.1.4.1.12148.7.5.5.2.1.3 | Integer32 | read-only | The rectifier current of the rectifier record. |
| I32 rectifierStatusOutputVoltage | 1.3.6.1.4.1.12148.7.5.5.2.1.4 | Integer32 | read-only | The rectifier voltage of the rectifier record. |
| I32 rectifierStatusTemp | 1.3.6.1.4.1.12148.7.5.5.2.1.5 | Integer32 | read-only | The heatsink temperature of the rectifier record. |
| STR rectifierStatusType | 1.3.6.1.4.1.12148.7.5.5.2.1.6 | DisplayString | read-only | The rectifier article number string of the rectifier record. |
| STR rectifierStatusSKU | 1.3.6.1.4.1.12148.7.5.5.2.1.7 | DisplayString | read-only | The rectifier Stock Keeping Unit number or other user-defined ID of the rectifier record. |
| STR rectifierStatusSerialNo | 1.3.6.1.4.1.12148.7.5.5.2.1.8 | DisplayString | read-only | The rectifier serial number string of the rectifier record. |
| STR rectifierStatusRevisionLevel | 1.3.6.1.4.1.12148.7.5.5.2.1.9 | DisplayString | read-only | The rectifier version number string of the rectifier record. |
| acDistribution | 1.3.6.1.4.1.12148.7.6 | |||
| I32 acVoltage1 | 1.3.6.1.4.1.12148.7.6.1 | Integer32 | read-only | The AC Voltage of phase 1 |
| I32 acVoltage2 | 1.3.6.1.4.1.12148.7.6.2 | Integer32 | read-only | The AC Voltage of phase 2 |
| I32 acVoltage3 | 1.3.6.1.4.1.12148.7.6.3 | Integer32 | read-only | The AC Voltage of phase 3 |
| alarmGroup | 1.3.6.1.4.1.12148.7.7 | |||
| alarmWellknownAlarms | 1.3.6.1.4.1.12148.7.7.1 | |||
| INT alarmMajorHighBattVolt | 1.3.6.1.4.1.12148.7.7.1.1 | INTEGER | read-only | The Very High Battery Voltage Alarm |
| INT alarmMinorHighBattVolt | 1.3.6.1.4.1.12148.7.7.1.2 | INTEGER | read-only | The High Battery Voltage alarm |
| INT alarmMajorLowBattVolt | 1.3.6.1.4.1.12148.7.7.1.3 | INTEGER | read-only | The Very Low Battery Voltage Alarm |
| INT alarmMinorLowBattVolt | 1.3.6.1.4.1.12148.7.7.1.4 | INTEGER | read-only | The Low Battery Voltage Alarm |
| INT alarmMajorBatteryHighTemp | 1.3.6.1.4.1.12148.7.7.1.5 | INTEGER | read-only | Temperature much too high alarm, or temperature compensation circuit / probe failure alarm |
| INT alarmMinorBatteryHighTemp | 1.3.6.1.4.1.12148.7.7.1.6 | INTEGER | read-only | Temperature much too high alarm |
| INT alarmBatteryDisconnectOpen | 1.3.6.1.4.1.12148.7.7.1.7 | INTEGER | read-only | The Battery Disconnect Contactor alarm |
| INT alarmLVD1open | 1.3.6.1.4.1.12148.7.7.1.8 | INTEGER | read-only | The A Bus (primary loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor will release. |
| INT alarmLVD2open | 1.3.6.1.4.1.12148.7.7.1.9 | INTEGER | read-only | The B Bus (secondary loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor will release. |
| INT alarmLVD3open | 1.3.6.1.4.1.12148.7.7.1.10 | INTEGER | read-only | The C Bus (critical loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor will release. |
| INT alarmACmains | 1.3.6.1.4.1.12148.7.7.1.11 | INTEGER | read-only | The AC voltage has dropped below critical level, or one or more AC input phases was lost. |
| INT alarmBatteryBreakerOpen | 1.3.6.1.4.1.12148.7.7.1.12 | INTEGER | read-only | Battery string disconnect breaker/fuse alarm |
| INT alarmDistributionBreakerOpen | 1.3.6.1.4.1.12148.7.7.1.13 | INTEGER | read-only | The Load Distribution breaker/fuse alarm |
| INT alarmMajorRectifier | 1.3.6.1.4.1.12148.7.7.1.14 | INTEGER | read-only | This is a 'multiple rectifiers have failed' alarm |
| INT alarmMinorRectifier | 1.3.6.1.4.1.12148.7.7.1.15 | INTEGER | read-only | This is a 'one rectifier has failed' alarm |
| INT alarmMajorBatteryMidpoint | 1.3.6.1.4.1.12148.7.7.1.16 | INTEGER | read-only | Battery Symmetry (midpoint) Delta Voltage is badly out of limits alarm |
| INT alarmMinorBatteryMidpoint | 1.3.6.1.4.1.12148.7.7.1.17 | INTEGER | read-only | Battery Symmetry (midpoint) Delta Voltage out of limits alarm |
| INT alarmBatteryLifeEnded | 1.3.6.1.4.1.12148.7.7.1.18 | INTEGER | read-only | The battery capacity has dropped below critical level. A battery test has measured the fully charged capacity to be too low, and thus probably the battery lifecycle to be near expired. |
| INT alarmBatteryTestmodeEntered | 1.3.6.1.4.1.12148.7.7.1.19 | INTEGER | read-only | The system has lowered the battery charge voltage in order to discharge the batteries to a predefinend level. When the criteria for stopping the battery testing is reached, the charge voltage is increased to commence normal charging. |
| INT alarmBatteryBoostmodeEntered | 1.3.6.1.4.1.12148.7.7.1.20 | INTEGER | read-only | The system has increased the battery charge voltage in order to equalize the battery cells charging. When the criteria for stopping the battery equalizing is reached, the charge voltage is lowered to commence normal charging. |
| INT alarmUserConfigurable1 | 1.3.6.1.4.1.12148.7.7.1.21 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable2 | 1.3.6.1.4.1.12148.7.7.1.22 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable3 | 1.3.6.1.4.1.12148.7.7.1.23 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable4 | 1.3.6.1.4.1.12148.7.7.1.24 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable5 | 1.3.6.1.4.1.12148.7.7.1.25 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable6 | 1.3.6.1.4.1.12148.7.7.1.26 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable7 | 1.3.6.1.4.1.12148.7.7.1.27 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable8 | 1.3.6.1.4.1.12148.7.7.1.28 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable9 | 1.3.6.1.4.1.12148.7.7.1.29 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable10 | 1.3.6.1.4.1.12148.7.7.1.30 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable11 | 1.3.6.1.4.1.12148.7.7.1.31 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable12 | 1.3.6.1.4.1.12148.7.7.1.32 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable13 | 1.3.6.1.4.1.12148.7.7.1.33 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| INT alarmUserConfigurable14 | 1.3.6.1.4.1.12148.7.7.1.34 | INTEGER | read-only | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
| dcSystemTraps | 1.3.6.1.4.1.12148.7.8 | This branch contains the Alarm Notification Traps, which duplicate the alarmGroup OIDs. Each alarm condition is represented by a Alarm Condition Trap and an associated OFF Trap, which is optionally transmitted according to the state of OID systemSendOffTrap | ||
| NTF alarmMajorHighBattVoltTrap | 1.3.6.1.4.1.12148.7.8.1 | The Very High Battery Voltage alarm | ||
| NTF alarmMinorHighBattVoltTrap | 1.3.6.1.4.1.12148.7.8.2 | The High Battery Voltage alarm | ||
| NTF alarmMajorLowBattVoltTrap | 1.3.6.1.4.1.12148.7.8.3 | The Very Low Battery Voltage Alarm | ||
| NTF alarmMinorLowBattVoltTrap | 1.3.6.1.4.1.12148.7.8.4 | The Low Battery Voltage Alarm | ||
| NTF alarmMajorBatteryHighTempTrap | 1.3.6.1.4.1.12148.7.8.5 | High Battery temperature alarm or Temperature Compensation circuit / probe failure alarm | ||
| NTF alarmMinorBatteryHighTempTrap | 1.3.6.1.4.1.12148.7.8.6 | High Battery temperature alarm | ||
| NTF alarmBatteryDisconnectOpenTrap | 1.3.6.1.4.1.12148.7.8.7 | The Battery Disconnect Contactor alarm | ||
| NTF alarmLVD1openTrap | 1.3.6.1.4.1.12148.7.8.8 | The A Bus (primary loads) Contactor is open alarm | ||
| NTF alarmLVD2openTrap | 1.3.6.1.4.1.12148.7.8.9 | The B Bus (secondary loads) Contactor is open alarm | ||
| NTF alarmLVD3openTrap | 1.3.6.1.4.1.12148.7.8.10 | The C Bus (critical loads) Contactor alarm. The contactor dropout voltage has been reached and the contactor is released. | ||
| NTF alarmACmainsTrap | 1.3.6.1.4.1.12148.7.8.11 | The AC voltage has dropped below critical level, or one or more AC input phases was lost. | ||
| NTF alarmBatteryBreakerOpenTrap | 1.3.6.1.4.1.12148.7.8.12 | Battery string disconnect breaker/fuse alarm | ||
| NTF alarmDistributionBreakerOpenTrap | 1.3.6.1.4.1.12148.7.8.13 | The Load Distribution breaker/fuse alarm | ||
| NTF alarmMajorRectifierTrap | 1.3.6.1.4.1.12148.7.8.14 | This is a 'multiple rectifiers have failed' alarm | ||
| NTF alarmMinorRectifierTrap | 1.3.6.1.4.1.12148.7.8.15 | This is a 'one rectifier has failed' alarm | ||
| NTF alarmMajorBatteryMidpointTrap | 1.3.6.1.4.1.12148.7.8.16 | Battery Symmetry (midpoint) Delta Voltage out of 'major fault' limits alarm | ||
| NTF alarmMinorBatteryMidpointTrap | 1.3.6.1.4.1.12148.7.8.17 | Battery Symmetry (midpoint) Delta Voltage out of limits alarm | ||
| NTF alarmBatteryLifeEndedTrap | 1.3.6.1.4.1.12148.7.8.18 | The battery capacity has dropped below critical level. A battery test has measured the fully charged capacity to be too low, and thus probably the battery lifecycle to be near expired. | ||
| NTF alarmBatteryTestmodeEnteredTrap | 1.3.6.1.4.1.12148.7.8.19 | The system has lowered the battery charge voltage in order to discharge the batteries to a predefinend level. When the criteria for stopping the battery testing is reached, the charge voltage is increased to commence normal charging. | ||
| NTF alarmBatteryBoostmodeEnteredTrap | 1.3.6.1.4.1.12148.7.8.20 | The system has increased the battery charge voltage in order to equalize the battery cells charging. When the criteria for stopping the battery equalizing is reached, the charge voltage is lowered to commence normal charging. | ||
| NTF alarmUserConfigurable1Trap | 1.3.6.1.4.1.12148.7.8.21 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable2Trap | 1.3.6.1.4.1.12148.7.8.22 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable3Trap | 1.3.6.1.4.1.12148.7.8.23 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable4Trap | 1.3.6.1.4.1.12148.7.8.24 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable5Trap | 1.3.6.1.4.1.12148.7.8.25 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable6Trap | 1.3.6.1.4.1.12148.7.8.26 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable7Trap | 1.3.6.1.4.1.12148.7.8.27 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable8Trap | 1.3.6.1.4.1.12148.7.8.28 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable9Trap | 1.3.6.1.4.1.12148.7.8.29 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable10Trap | 1.3.6.1.4.1.12148.7.8.30 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable11Trap | 1.3.6.1.4.1.12148.7.8.31 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable12Trap | 1.3.6.1.4.1.12148.7.8.32 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable13Trap | 1.3.6.1.4.1.12148.7.8.33 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. | ||
| NTF alarmUserConfigurable14Trap | 1.3.6.1.4.1.12148.7.8.34 | Generic alarm linked to user specified alarms. These have no specific name in the MIB. User configurable alarms will on some systems have text attached to the traps that explains the purpose of the alarm. |
RFC description
Vendor-private MIB for Eltek power supply and environmental monitoring systems, providing generic device management objects.
Start monitoring Eltek DC power-system control unit (site identity/trap config) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.