ELTEK-GENERIC-MIB

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ELTEK-GENERIC-MIB

Category: Domain: Power/UPS, Vendor: Eltek

Description: Eltek generic MIB providing common management objects applicable across the Eltek range of power management products.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is ELTEK-GENERIC-MIB?

ELTEK-GENERIC-MIB is a vendor-specific MIB from Eltek providing common management objects shared across Eltek's DC power management and rectifier/controller product range, under the eltekPlant and controlSystem enterprise branches. It exposes system time (for event timestamping and log correlation), site identification data such as customer, location, install date, and controller/system serial numbers, plus trap notification settings. This supports monitoring the software status of the power system controller's management agent, tracking whether its clock is correct for accurate alarm timestamps and whether trap notification/repeat behavior is properly configured so alarms aren't silently dropped. It serves as the generic base underlying Eltek's broader power management MIB family, used alongside more specific Eltek MIBs that expose actual rectifier/battery telemetry. It is typically deployed on DC power plant controllers monitoring telecom or data center power systems. Network engineers evaluating or troubleshooting this functionality can download the ELTEK-GENERIC-MIB file directly to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in ELTEK-GENERIC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Eltek DC power system controller (rectifier/power plant controller)

Monitoring Examples

Polling systemTimeTime confirms the controller's clock, critical for correlating alarm timestamps in event logs, while systemSiteInfoControllerType, systemSiteInfoSystemSeriaNum, and systemSiteInfoControllerSeriaNum let an operator confirm which physical controller and site (systemSiteInfoCustomer, systemSiteInfoLocation) a given SNMP agent corresponds to across a fleet of power plants. systemSendOffTrap and systemTrapRepeatRate govern whether and how often the device re-sends outstanding alarm traps, so an admin troubleshooting a missed alert would check whether trap repeating was disabled.

What Can Be Monitored

  • system time/clock
  • site and customer identification
  • controller and system serial numbers
  • installed date
  • trap repeat rate and notification enable
Imported Objects

From ELTEK-COMMON-MIB

eltekMODULE-IDENTITY

From SNMPv2-CONF

NOTIFICATION-GROUP

From SNMPv2-SMI

Integer32
MODULE-IDENTITY
NOTIFICATION-TYPE
OBJECT-TYPE
enterprises
mib-2

From SNMPv2-TC

DisplayString
OIDs

RFC description

Vendor-private MIB for Eltek power supply and environmental monitoring systems, providing generic device management objects.

Start monitoring Eltek DC power-system control unit (site identity/trap config) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download ELTEK-GENERIC-MIB