LIEBERT-GP-POWER-MIB :: lgpPwrMeasurementPointFrequency

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-POWER-MIB › lgpPwrMeasurementPointFrequency

lgpPwrMeasurementPointFrequency

Module: LIEBERT-GP-POWER-MIB

OID (symbolic): LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointFrequency

OID (numeric): 1.3.6.1.4.1.476.1.42.3.5.2.2.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The present (actual) frequency for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwrMeasurementPointTable.

What is lgpPwrMeasurementPointFrequency?

The present, actual measured frequency at this power measurement point, in Hertz. Comparing this live value to lgpPwrMeasurementPointNomFrequency reveals whether the source (e.g. a generator) is running out of spec.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.2.2.1.6
snmpwalk -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointFrequency

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.2.2.1.6.1
snmpget -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointFrequency.1

Start monitoring Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointFrequency OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.5lgpPowerLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.5.2lgpPwrMeasurementsLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.2.2lgpPwrMeasurementPointTableLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.2.2.1lgpPwrMeasurementPointEntryLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.2.2.1.6lgpPwrMeasurementPointFrequencyLIEBERT-GP-POWER-MIB