LIEBERT-GP-POWER-MIB :: lgpPwrDcMeasurementPointId

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-POWER-MIB › lgpPwrDcMeasurementPointId

lgpPwrDcMeasurementPointId

Module: LIEBERT-GP-POWER-MIB

OID (symbolic): LIEBERT-GP-POWER-MIB::lgpPwrDcMeasurementPointId

OID (numeric): 1.3.6.1.4.1.476.1.42.3.5.2.4.1.2

Node type: OBJECT-TYPE

Type: OBJECT IDENTIFIER

Access: read-only

Description: An OID representing a well known measurement point. These object identifiers indicate a point or location of power measurement in a power system. The OID's name usually implies a location of the measurement point such as 'input', 'output', 'bypass' etc.

What is lgpPwrDcMeasurementPointId?

In the DC power measurement point table, this OID identifies which well-known measurement location (e.g. battery, DC bus) a given row's DC readings apply to. It lets monitoring software map a row's voltage/current/power values to a specific DC point in the system.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.2.4.1.2
snmpwalk -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrDcMeasurementPointId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.2.4.1.2.1
snmpget -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrDcMeasurementPointId.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> lgpPwrDcMeasurementPointId.1

Start monitoring Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-POWER-MIB::lgpPwrDcMeasurementPointId OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.5lgpPowerLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.5.2lgpPwrMeasurementsLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.2.4lgpPwrDcMeasurementPointTableLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.2.4.1lgpPwrDcMeasurementPointEntryLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.2.4.1.2lgpPwrDcMeasurementPointIdLIEBERT-GP-POWER-MIB