LIEBERT-GP-POWER-MIB :: lgpPwrUpsTopOffline

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-POWER-MIB › lgpPwrUpsTopOffline

lgpPwrUpsTopOffline

Module: LIEBERT-GP-POWER-MIB

OID (symbolic): LIEBERT-GP-POWER-MIB::lgpPwrUpsTopOffline

OID (numeric): 1.3.6.1.4.1.476.1.42.3.5.7.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The UPS has an offline topology. Under normal operating conditions, AC power from the utility passes straight through the UPS to the critical load. The inverter is used to convert the DC power from the battery to create AC power to support the load when the utility fails. Normally the inverter is operating in the stand-by mode, keeping the batteries charged. Should the utility power go out of specification, the inverter will power the load by drawing energy from the battery.

What is lgpPwrUpsTopOffline?

Indicates whether the UPS has an offline topology (yes/no), where utility power normally passes straight through to the load and the inverter only engages from battery when utility fails. This tells an admin what behavior to expect during a power event -- notably a brief transfer time versus the zero-interruption behavior of an online/double-conversion unit.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.7.1
snmpwalk -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrUpsTopOffline

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.7.1.1
snmpget -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrUpsTopOffline.1

Start monitoring Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-POWER-MIB::lgpPwrUpsTopOffline OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.5lgpPowerLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.5.7lgpPwrTopologyLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.7.1lgpPwrUpsTopOfflineLIEBERT-GP-POWER-MIB