lgpPwrBatteryPresentDischargeTime

Module: LIEBERT-GP-POWER-MIB

OID (symbolic): LIEBERT-GP-POWER-MIB::lgpPwrBatteryPresentDischargeTime

OID (numeric): 1.3.6.1.4.1.476.1.42.3.5.1.25

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The total time spent on battery during the current or last discharge.

NOTE: While not discharging, some systems may display zero instead of the last discharge.

What is lgpPwrBatteryPresentDischargeTime?

The total time, in seconds, spent running on battery during the current or most recent discharge. The MIB notes some systems report zero here once discharging has stopped rather than retaining the last discharge duration.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.1.25
snmpwalk -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrBatteryPresentDischargeTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.1.25.1
snmpget -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrBatteryPresentDischargeTime.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> lgpPwrBatteryPresentDischargeTime.1

Start monitoring Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-POWER-MIB::lgpPwrBatteryPresentDischargeTime OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.5lgpPowerLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.5.1lgpPwrBatteryLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.1.25lgpPwrBatteryPresentDischargeTimeLIEBERT-GP-POWER-MIB