LIEBERT-GP-POWER-MIB :: lgpPwrThresholdType

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LIEBERT-GP-POWER-MIB › lgpPwrThresholdType

lgpPwrThresholdType

Module: LIEBERT-GP-POWER-MIB

OID (symbolic): LIEBERT-GP-POWER-MIB::lgpPwrThresholdType

OID (numeric): 1.3.6.1.4.1.476.1.42.3.5.4.7.1.4

Node type: OBJECT-TYPE

Type: OBJECT IDENTIFIER

Access: read-only

Description: An OID representing a well known measurement type. These object identifiers indicate the type of measurement referenced by the row of the table. These object identifiers can encompass units of measure, lines of reference, and device location. The OID's name usually implies a measurement type such as 'voltsAc', 'current', 'voltsDc', 'VoltsLL', etc.

What is lgpPwrThresholdType?

An OID identifying the well-known type of measurement (e.g. voltsAc, current, voltsDc) that the row's threshold values apply to. This tells software what kind of value the accompanying high/low warning and failure thresholds are meant to be compared against.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.4.7.1.4
snmpwalk -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrThresholdType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.4.7.1.4.1
snmpget -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrThresholdType.1

Start monitoring Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-POWER-MIB::lgpPwrThresholdType OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.476emersonLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1liebertCorpLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42liebertGlobalProductsLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3lgpFoundationLIEBERT-GP-REGISTRATION-MIB
1.3.6.1.4.1.476.1.42.3.5lgpPowerLIEBERT-GP-REGISTRATION-MIB
Numeric OIDNameModule
1.3.6.1.4.1.476.1.42.3.5.4lgpPwrSettingsLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.4.7lgpPwrThresholdTableLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.4.7.1lgpPwrThresholdEntryLIEBERT-GP-POWER-MIB
1.3.6.1.4.1.476.1.42.3.5.4.7.1.4lgpPwrThresholdTypeLIEBERT-GP-POWER-MIB