All MIBs › LIEBERT-GP-POWER-MIB › lgpPwrMeasurementPointNomVA
lgpPwrMeasurementPointNomVA
Module: LIEBERT-GP-POWER-MIB
OID (symbolic): LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointNomVA
OID (numeric): 1.3.6.1.4.1.476.1.42.3.5.2.2.1.16
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: The nominal or configured/expected apparent AC power for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwrMeasurementPointTable.
What is lgpPwrMeasurementPointNomVA?
The nominal or configured apparent power rating (Volt-Amps) for this measurement point, and it is writable so an installer can set the expected capacity for a given point. Capacity alarms and percent-load calculations for that point are derived from this configured value.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.2.2.1.16 snmpwalk -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointNomVA
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.2.2.1.16.1 snmpget -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointNomVA.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.476.1.42.3.5.2.2.1.16.1 i <value>
Start monitoring Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointNomVA OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.476 | emerson | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1 | liebertCorp | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1.42 | liebertGlobalProducts | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1.42.3 | lgpFoundation | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1.42.3.5 | lgpPower | LIEBERT-GP-REGISTRATION-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.476.1.42.3.5.2 | lgpPwrMeasurements | LIEBERT-GP-POWER-MIB |
| 1.3.6.1.4.1.476.1.42.3.5.2.2 | lgpPwrMeasurementPointTable | LIEBERT-GP-POWER-MIB |
| 1.3.6.1.4.1.476.1.42.3.5.2.2.1 | lgpPwrMeasurementPointEntry | LIEBERT-GP-POWER-MIB |
| 1.3.6.1.4.1.476.1.42.3.5.2.2.1.16 | lgpPwrMeasurementPointNomVA | LIEBERT-GP-POWER-MIB |