All MIBs › LIEBERT-GP-POWER-MIB › lgpPwrMeasurementPointNomW
lgpPwrMeasurementPointNomW
Module: LIEBERT-GP-POWER-MIB
OID (symbolic): LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointNomW
OID (numeric): 1.3.6.1.4.1.476.1.42.3.5.2.2.1.17
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: The nominal or configured/expected true AC power for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwrMeasurementPointTable.
What is lgpPwrMeasurementPointNomW?
The nominal or configured true power rating (Watts) for this measurement point, writable to match the site's expected load. This works alongside lgpPwrMeasurementPointNomVA to define the reference power factor for capacity planning at that point.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.2.2.1.17 snmpwalk -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointNomW
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.476.1.42.3.5.2.2.1.17.1 snmpget -v2c -c public <target> LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointNomW.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.476.1.42.3.5.2.2.1.17.1 i <value>
Start monitoring Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LIEBERT-GP-POWER-MIB::lgpPwrMeasurementPointNomW OID value, configure state conditions and alerts, and monitor any Liebert/Vertiv UPS/PDU and power-conditioning equipment (battery health) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.476 | emerson | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1 | liebertCorp | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1.42 | liebertGlobalProducts | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1.42.3 | lgpFoundation | LIEBERT-GP-REGISTRATION-MIB |
| 1.3.6.1.4.1.476.1.42.3.5 | lgpPower | LIEBERT-GP-REGISTRATION-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.476.1.42.3.5.2 | lgpPwrMeasurements | LIEBERT-GP-POWER-MIB |
| 1.3.6.1.4.1.476.1.42.3.5.2.2 | lgpPwrMeasurementPointTable | LIEBERT-GP-POWER-MIB |
| 1.3.6.1.4.1.476.1.42.3.5.2.2.1 | lgpPwrMeasurementPointEntry | LIEBERT-GP-POWER-MIB |
| 1.3.6.1.4.1.476.1.42.3.5.2.2.1.17 | lgpPwrMeasurementPointNomW | LIEBERT-GP-POWER-MIB |