CABLETRON-TRAPS

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CABLETRON-TRAPS

Category: Alarm and Event Management, Vendor: Cabletron/Enterasys

Description: Defines SNMP trap notifications for Cabletron Systems (Enterasys) network devices including fault and status change events.

Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

What Is CABLETRON-TRAPS?

CABLETRON-TRAPS is a legacy vendor-specific MIB (originally Cabletron Systems, later maintained by Enterasys Networks) that defines enterprise SNMP TRAP-TYPE notifications for Cabletron/Enterasys MMAC chassis-based network devices, spanning repeater/port link and segmentation state, board insertion/removal, redundancy switchover, environmental (temperature, voltage, fan) faults, and Token Ring (802.5) station/beacon/security events. It defines no OBJECT-TYPE tables of its own; instead each TRAP-TYPE (e.g., portLinkUp/portLinkDown, boardInsertion/boardRemoval, envTempHot/envTempNormal, beaconState, rptrErrorThresholdExceeded) carries VARIABLES imported from many companion Cabletron MIBs (REPEATER-REV4-MIB, CTRON-POWER-SUPPLY-MIB, CTRON-ENVIRONMENT-MIB, DOT5-LOG-MIB, and others). Monitoring these traps is useful for real-time fault detection on Cabletron/Enterasys MMAC repeaters and Token Ring modules, such as segmented ports, chassis power/thermal faults, or Token Ring beaconing conditions, without polling every underlying counter. It depends on and complements the many Cabletron enterprise MIBs it imports variables from, and administrators can download the CABLETRON-TRAPS file to load it into their MIB browser.

IPNetwork Monitor allows you to monitor SNMP objects defined in CABLETRON-TRAPS. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.

Supported Devices

  • Cabletron/Enterasys MMAC chassis hubs and Token Ring concentrators

Monitoring Examples

A management station subscribes to portLinkDown and boardRemoval traps carrying rptrPortMgmtPortId and chSlotID to detect when a MIM module or port is pulled from an MMAC chassis; repeated envTempHot traps for the same chSlotID without a following envTempNormal would indicate a persistent chassis cooling problem.

What Can Be Monitored

  • port link up/down and segmentation traps
  • board/module insertion and removal traps
  • environmental (temperature/voltage/fan) fault traps
  • traffic/error/collision/broadcast threshold traps
  • Token Ring beacon and security violation traps
Imported Objects

From ATM-MIB

atmInterfaceMyNeighborIfNameOBJECT-TYPE
atmInterfaceMyNeighborIpAddressOBJECT-TYPE
atmVcCrossConnectRowStatusOBJECT-TYPE
atmVpCrossConnectRowStatusOBJECT-TYPE

From CHASSIS-MIB

chSlotID
chSlotModuleType

From CT-BROADCAST-MIB

ctBroadcastCtlInterfaceOBJECT-TYPE
ctBroadcastCtlSlotIDOBJECT-TYPE
ctBroadcastDesiredBroadcastThresholdOBJECT-TYPE

From CT-CONTAINER-MIB

contPhysicalEntryIDOBJECT-TYPE
contTypeLogicalChangesOBJECT-TYPE
contTypePhysicalChangesOBJECT-TYPE

From CTATM-CONFIG-MIB

ctATMPhyRedundIfIndexOBJECT-TYPE

From CTIF-EXT-MIB

ctIfNumberOBJECT-TYPE
ctIfPortPortNumberOBJECT-TYPE
ctIfPortTypeOBJECT-TYPE

From CTRON-AppleTalk-ROUTER-MIB

nwAtEventTextStringOBJECT-TYPE

From CTRON-APPN-MIB

nwAppnEventTextStringOBJECT-TYPE
nwAppnFwdLsAdjCpNameOBJECT-TYPE
nwAppnFwdLsAdjCpTypeOBJECT-TYPE
nwAppnFwdLsNameOBJECT-TYPE

From CTRON-BDG-MIB

bdgdeviceStatusOBJECT-TYPE

From CTRON-CHASSIS-MIB

ctChasPowerSupplyNumOBJECT-TYPE
ctChasPowerSupplyTypeOBJECT-TYPE

From CTRON-COMMON-MIB

deviceTypeOBJECT-TYPE
powerSupplyNumOBJECT-TYPE

From CTRON-DECIV-ROUTER-MIB

nwDecIVEventTextStringOBJECT-TYPE

From CTRON-ENVIRONMENT-MIB

boardEnvSlotIDOBJECT-TYPE
boardEnvTempOBJECT-TYPE
boardEnvTempRelStatusOBJECT-TYPE
boardEnvTempStatusOBJECT-TYPE
chEnvAmbientStatusOBJECT-TYPE
chEnvAmbientTempOBJECT-TYPE
chEnvFanIDOBJECT-TYPE
chEnvFanSpeedOBJECT-TYPE
chEnvFanStatusOBJECT-TYPE
chEnvHumidityOBJECT-TYPE
chEnvHumidityStatusOBJECT-TYPE
psEnvFanSpeedOBJECT-TYPE
psEnvFanStatusOBJECT-TYPE
psEnvSlotIDOBJECT-TYPE
psEnvTempOBJECT-TYPE
psEnvTempStatusOBJECT-TYPE

From CTRON-FRONTPANEL-MIB

ctFpRedundActivePortOBJECT-TYPE

From CTRON-IP-ROUTER-MIB

nwIpEventTextStringOBJECT-TYPE

From CTRON-IPX-ROUTER-MIB

nwIpxEventTextStringOBJECT-TYPE

From CTRON-OIDS

cabletronOBJECT-IDENTITY

From CTRON-POWER-SUPPLY-MIB

boardPowerCurrentOBJECT-TYPE
boardPowerIDOBJECT-TYPE
boardPowerLocalAdminStatusOBJECT-TYPE
boardPowerLocalStatusOBJECT-TYPE
boardPowerOperationalStatusOBJECT-TYPE
boardPowerSlotIDOBJECT-TYPE
boardPowerSlotStatusIDOBJECT-TYPE
boardPowerStatusOBJECT-TYPE
boardPowerVoltageOBJECT-TYPE
chPowerDiagVoltageOBJECT-TYPE
chPowerDiagVoltageStatusOBJECT-TYPE
chPowerLineMaxSupplyOBJECT-TYPE
chPowerLineTotalSupplyOBJECT-TYPE
chPowerMainVoltageOBJECT-TYPE
chPowerMainVoltageStatusOBJECT-TYPE
psPowerAdminOBJECT-TYPE
psPowerCurrentOBJECT-TYPE
psPowerIDOBJECT-TYPE
psPowerOperationalStatusOBJECT-TYPE
psPowerSlotIDOBJECT-TYPE
psPowerSlotStatusIDOBJECT-TYPE
psPowerStatusOBJECT-TYPE
psPowerVoltageOBJECT-TYPE
termPowerModule1StatusOBJECT-TYPE
termPowerModule2StatusOBJECT-TYPE
termPowerStatusOBJECT-TYPE
termPowerVoltageOBJECT-TYPE

From CTRON-SFPS-BASE-MIB

sfpsBlockSourceMACOBJECT-TYPE

From CTRON-SFPS-DIRECTORY-MIB

sfpsNodeTableBaseAddressOBJECT-TYPE
sfpsNodeTablePortOBJECT-TYPE

From CTRON-SFPS-PORT-MIB

sfpsInPortConfigPortOBJECT-TYPE
sfpsInPortConfigTypeOBJECT-TYPE

From CTRON-SFPS-RESOLVE-MIB

sfpsBlockResolveTableAOValueOBJECT-TYPE

From CTRON-SFPS-TOPOLOGY-MIB

sfpsDirViolationAOValueOBJECT-TYPE
sfpsDirViolationTypeOBJECT-TYPE

From CTSMTMIB-MIB

ctsmtmibRingMacAddrOBJECT-TYPE
ctsmtmibRingMacIndexOBJECT-TYPE
ctsmtmibRingNodeIndexOBJECT-TYPE
ctsmtmibRingSmtIndexOBJECT-TYPE
ctsmtmibRingTopologyOBJECT-TYPE

From DLM-MIB

snmpOIDDestinationOBJECT-TYPE
snmpOIDObjectOBJECT-TYPE
snmpOIDOwnerOBJECT-TYPE
snmpOIDSequenceOBJECT-TYPE
snmpPollDestinationOBJECT-TYPE
snmpPollOwnerOBJECT-TYPE

From DOT5-LOG-MIB

tRingAlarmsRingAMPErrsThresholdOBJECT-TYPE
tRingAlarmsRingBeaconStateThresholdOBJECT-TYPE
tRingAlarmsRingClaimTknThresholdOBJECT-TYPE
tRingAlarmsRingFrameCountThresholdOBJECT-TYPE
tRingAlarmsRingLostFramesThresholdOBJECT-TYPE
tRingAlarmsRingRingPurgesThresholdOBJECT-TYPE
tRingAlarmsRingTimebaseOBJECT-TYPE
tRingAlarmsRingTokenErrsThresholdOBJECT-TYPE
tRingAlarmsStnThrshACErrsThresholdOBJECT-TYPE
tRingAlarmsStnThrshAddressOBJECT-TYPE
tRingAlarmsStnThrshBurstErrsThresholdOBJECT-TYPE
tRingAlarmsStnThrshInternalErrsThresholdOBJECT-TYPE
tRingAlarmsStnThrshLineErrsThresholdOBJECT-TYPE
tRingAlarmsStnThrshRcvrCongestThresholdOBJECT-TYPE
tRingMgmtSecurityAddressAddOBJECT-TYPE
tRingMgmtSecurityAddressRemoveOBJECT-TYPE
tRingMgmtStnAddressOBJECT-TYPE
tRingMgmtStnBoardOBJECT-TYPE
tRingMgmtStnDNAOBJECT-TYPE
tRingMgmtStnNameOBJECT-TYPE
tRingMgmtStnPortOBJECT-TYPE
tRingMgmtStnUNAOBJECT-TYPE
tRingPortGrpIdOBJECT-TYPE
tRingPortMgmtPortIdOBJECT-TYPE
tRingStatsRingLastBeaconOBJECT-TYPE
tRingStatsRingLastBeaconTypeOBJECT-TYPE

From FDDI-SMT73-MIB

fddimibMACCurrentPathOBJECT-TYPE
fddimibMACFrameErrorRatioOBJECT-TYPE
fddimibMACIndexOBJECT-TYPE
fddimibMACRMTStateOBJECT-TYPE
fddimibPORTActionOBJECT-TYPE
fddimibPORTConnectStateOBJECT-TYPE
fddimibPORTIndexOBJECT-TYPE
fddimibPORTLerEstimateOBJECT-TYPE
fddimibSMTCFStateOBJECT-TYPE
fddimibSMTIndexOBJECT-TYPE
fddimibSMTMasterCtsOBJECT-TYPE

From LAN-EMULATION-CLIENT-MIB

lecRowStatusOBJECT-TYPE

From REPEATER-REV4-MIB

rptrAlarmsAlarmTimebaseOBJECT-TYPE
rptrAlarmsBroadThresholdOBJECT-TYPE
rptrAlarmsCollThresholdOBJECT-TYPE
rptrAlarmsErrSourceOBJECT-TYPE
rptrAlarmsErrThresholdOBJECT-TYPE
rptrAlarmsTrafThresholdOBJECT-TYPE
rptrMgmtInterfaceNumOBJECT-TYPE
rptrPortAlarmBroadThresholdOBJECT-TYPE
rptrPortAlarmCollThresholdOBJECT-TYPE
rptrPortAlarmErrSourceOBJECT-TYPE
rptrPortAlarmErrThresholdOBJECT-TYPE
rptrPortAlarmTrafThresholdOBJECT-TYPE
rptrPortGrpAlarmBroadThresholdOBJECT-TYPE
rptrPortGrpAlarmCollThresholdOBJECT-TYPE
rptrPortGrpAlarmErrSourceOBJECT-TYPE
rptrPortGrpAlarmErrThresholdOBJECT-TYPE
rptrPortGrpAlarmTrafThresholdOBJECT-TYPE
rptrPortGrpMgmtGrpIdOBJECT-TYPE
rptrPortGrpSASecurityLearnModeOBJECT-TYPE
rptrPortGrpSASecurityLearnStateOBJECT-TYPE
rptrPortGrpSrcAddrLockGrpIdOBJECT-TYPE
rptrPortMgmtPortIdOBJECT-TYPE
rptrPortMgmtPortTypeOBJECT-TYPE
rptrPortRedundCrctNumOBJECT-TYPE
rptrPortSecurityLearnModeOBJECT-TYPE
rptrPortSecurityLearnStateOBJECT-TYPE
rptrPortSecurityLockStatusOBJECT-TYPE
rptrPortSecurityPortGrpIdOBJECT-TYPE
rptrPortSecurityPortIdOBJECT-TYPE
rptrPortSecuritySecureStateOBJECT-TYPE
rptrPortSrcAddrAddressListOBJECT-TYPE
rptrPortSrcAddrTopoStateOBJECT-TYPE
rptrSecurityLearnModeOBJECT-TYPE
rptrSecurityLearnStateOBJECT-TYPE
rptrSrcAddrMgmtPortLockOBJECT-TYPE

From RFC-1215

TRAP-TYPE

From RFC1213-MIB

ifIndex

From RFC1271-MIB

logDescriptionOBJECT-TYPE
logEventIndexOBJECT-TYPE
logIndexOBJECT-TYPE
logTimeOBJECT-TYPE

From UPS2-MIB

upsAddlFuncsStatusFaultOBJECT-TYPE
upsExtMeasAlarmStatusOBJECT-TYPE
upsIndexOBJECT-TYPE
upsStatusFaultOBJECT-TYPE
OIDs

RFC description

SNMP trap definitions for Cabletron/Enterasys Networks managing IETF and enterprise-specific events.

Start monitoring Cabletron/Enterasys MMAC chassis hubs and Token Ring concentrators (legacy) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.

Download CABLETRON-TRAPS