All MIBs › NNCEXTSPVC-MIB
Organization: Alcatel CID
Last Updated: 2001-02-15
Category: ATM
Description: Manages Alcatel soft permanent virtual circuit setup, teardown, and status for ATM connections.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is NNCEXTSPVC-MIB?
NNCEXTSPVC-MIB is Alcatel CID's proprietary MIB, associated with the Newbridge/Alcatel multiservice switch family, for managing Soft Permanent Virtual Connections (SPVCs) across ATM, Frame Relay, and Circuit Emulation network endpoints. It exposes objects for creating, modifying, querying, and deleting SPVCs, including Permanent Virtual Path/Channel Connections (PVPC/PVCC) for Cell Relay endpoints and SPVCCs for Frame Relay and Circuit Emulation. It is used in monitoring to track the operational and provisioning status of virtual circuits — verifying configured SPVCs are correctly set up, active, and torn down as expected — which is central to fault detection in ATM/Frame Relay transport networks. As an extension to core ATM/Frame Relay connection management, it likely depends on standard ATM-MIB or Frame Relay DTE MIB conventions for underlying interface and VPI/VCI addressing. It is typically deployed in carrier or enterprise WAN environments using Alcatel/Newbridge ATM switches to provision and monitor soft PVCs across a multi-service transport network. Engineers can download the NNCEXTSPVC-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in NNCEXTSPVC-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- Alcatel/Newbridge ATM/Frame Relay switch
Monitoring Examples
An operator managing SPVCs would query the connection status objects for a given PVPC or PVCC endpoint to confirm the soft permanent virtual connection has been successfully established end-to-end, and monitor for unexpected teardown or failure states. Because specific object/table names were not present in the sample data, this example is grounded directly in the module's documented scope of creating, modifying, querying, and deleting SPVCs on Cell Relay, Frame Relay, and Circuit Emulation endpoints.
What Can Be Monitored
- SPVC connection status (established/torn down)
- PVPC/PVCC endpoint state
- Frame Relay and Circuit Emulation SPVCC status
This MIB depends on
Related MIBs
Imported Objects
From ATM-MIB
| atmVclVci | OBJECT-TYPE |
| atmVclVpi | OBJECT-TYPE |
| atmVplVpi | OBJECT-TYPE |
From IF-MIB
| ifIndex | OBJECT-TYPE |
From NNCGNI0001-SMI
| nncExtensions | OBJECT-IDENTITY |
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-TYPE |
From SNMPv2-TC
| RowStatus | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| nncExtSpvc | 1.3.6.1.4.1.123.3.82 | This module contains Alcatel CID's proprietary MIB definition for managing Soft Permanent Virtual Connections (SPVCs). This MIB supports the creation, modification, query, and deletion of SPVCs (Soft Permanent Virtual Connections), on Cell Relay (ATM), Frame Relay, and Circuit Emulation endpoints. For Cell Relay-based endpoints, Permanent Virtual Path Connection (PVPC) and Permanent Virtual Channel Connection (PVCC) are supported, while SPVCCs are supported on Frame Relay and Circuit Emulation endpoints. Cell Relay SPVCs, Frame Relay SPVCs and Circuit Emulation SPVCs are supported in this MIB. SPVCs with any other service types are not supported at this point. For SPVCs interworking across different endpoint types, CR to FR, FR to CR, CR to CE, CE to CR connections are supported. CE to FR or FR to CE are not suppported. Operator directed routing for SPVC connections is not supported at this point. To create an SPVC, the required MIB objects from the destination table must be configured and sent to the destination endpoint. Next, the MIB objects from the source endpoint table (based on the endpoint type and SPVC type - either nncCrSpvpcTable, nncCrSpvccTable, nncFrSpvcTable, or nncCeSpvcTable) are configured and sent to the source endpoint. Assuming a PDU with a RowStatus of 'createAndGo' or 'Active' has been received, if the adminStatus of the SPVC is set to 'enabled', the SPVC will be connected; if the adminStatus of the SPVC is set to 'disabled', the SPVC will be configured but not connected. SPVC creation SET-REQuests can be sent two ways: using a RowStatus value of 'createAndGo', or using multiple SET-REQs using RowStatus values of 'createAndWait' and 'active'. Creating an SPVC using rowStatus=createAndWait(5) In the case of multiple SET-REQs, the RowStatus is set to createAndWait(5) for all but the last SET-REQ, and set to active(1) for the last SET-REQ. The SPVC is configured only after the last PDU (with RowStatus as 'active') is received. Creating an SPVC using rowStatus=createAndGo(4) In the other case, all required MIB objects can fit in one SET-REQ. If using only one SET-REQ, the RowStatus should be set to createAndGo(4). In both cases, default values for MIB objects will be used wherever possible. To delete an SPVC, the correct table objects must be sent to both the destination endpoint and the source endpoint for the given SPVC, using the correct index, and setting the rowStatus to 'destroy'. This will delete the specified SPVC. Some abreviations: abr/ABR/Abr: Available Bit Rate Bwd: Backward. For traffice descriptors from destination endpoint to source endpoint (receiving traffic) cbr/CBR/Cbr: Constant Bit Rate Dst: Destination endpoint Fwd: Forward. For traffic descriptors from source endpoint to destination endpoint (transmitting traffic) nt-vbr/nrtvbr/NRT-VBR: Non-Real-Time Variable Bit Rate Src: Source endpoint Targ: Target. For the destination endpoint info in source endpoint table ubr/UBR/Ubr: Unspecified Bit Rate | ||
| nncExtSpvcObjects | 1.3.6.1.4.1.123.3.82.1 | |||
| nncCrSpvpcTable | 1.3.6.1.4.1.123.3.82.1.1 | not-accessible | nncCrSpvpcTable contains all the objects sent to a source endpoint that are used to create, modify, query and delete SPVC connections. | |
| nncCrSpvpcTableEntry | 1.3.6.1.4.1.123.3.82.1.1.1 | not-accessible | An entry of nncCrSpvpcTable | |
| INT nncCrSpvpcServiceCategory | 1.3.6.1.4.1.123.3.82.1.1.1.1 | INTEGER | read-create | This object is used to set the traffic service category. This object is dependent on the value specified in nncCrSpvpcTrafficDescriptor |
| ATM nncCrSpvpcTargEpAddr | 1.3.6.1.4.1.123.3.82.1.1.1.2 | AtmFormatDisplay | read-create | This object is used to specify the 20 byte AESA address for the target endpoint. The address map is as the following: Byte\Bit 8 7 6 5 4 3 2 1 ------------------------------------------------------------------------ 1-13 byte | 13-byte Internal Subscriber Prefix | ------------------------------------------------------------------------ 14th byte | I/G | U/L | OUI(most significant 6 bits) | ------------------------------------------------------------------------ 15th byte | OUI(2nd most significant 8 bits | ------------------------------------------------------------------------ 16th byte | OUI(3rd most significant 8 bits | ------------------------------------------------------------------------ 17th byte | Shelf/Slot(1st most significant 8 bits | ------------------------------------------------------------------------ 18th byte | Shelf/Slot(2nd most significant 8 bits | ------------------------------------------------------------------------ 19th byte |Flag0| Port | ------------------------------------------------------------------------ 20th byte | 0 | ------------------------------------------------------------------------ |
| INT nncCrSpvpcTargVpi | 1.3.6.1.4.1.123.3.82.1.1.1.3 | INTEGER | read-create | This object contains the virtual path identifier (VPI) value for the target endpoint. Range: 0 - 4095 |
| INT nncCrSpvpcAdminStatus | 1.3.6.1.4.1.123.3.82.1.1.1.4 | INTEGER | read-create | This object accepts two values, enabled (1), and disabled (2). When the value is disabled, the SPVC is not connected. When enabled, the SPVC is connected when possible. Use nncCrSpvpcAdminStatus to determine if the connection is successful. |
| INT nncCrSpvpcPriority | 1.3.6.1.4.1.123.3.82.1.1.1.5 | INTEGER | read-create | This object is used to set the priority for a SPVC connection request. It ranges between 1-16, with the following values: Best Priority = 1 Default Priority = 3 Worst Priority = 16 |
| I32 nncCrSpvpcMaxAdminWeight | 1.3.6.1.4.1.123.3.82.1.1.1.6 | Integer32 | read-create | This object is used to set a cost threshold for an SPVC connection. If the total cost of all VPCs exceeds this weight value for a given path, this SPVC will choose an alternative path or give up. Infinite = -1 Min Admin Weight = 0 Max Admin Weight = 2147483647 |
| INT nncCrSpvpcOperation | 1.3.6.1.4.1.123.3.82.1.1.1.7 | INTEGER | read-create | This object is used to request a reroute operation. Querying this object will not provide any useful information. |
| INT nncCrSpvpcCallStatus | 1.3.6.1.4.1.123.3.82.1.1.1.8 | INTEGER | read-only | This read-only object is used to query the state of a particular SPVC. SPVCs that are connected and operational will return a value of 'connected', while those that are incomplete or otherwise unable to be connected will return 'waitingForResources'. SPVCs that are configured but not yet connected will contain a value of 'readyForConnect'. |
| INT nncCrSpvpcLocRerouteConfig | 1.3.6.1.4.1.123.3.82.1.1.1.9 | INTEGER | read-create | This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled. |
| INT nncCrSpvpcFwdAbrDynTrfcIcr | 1.3.6.1.4.1.123.3.82.1.1.1.10 | INTEGER | read-create | ABR dynamic traffic descriptor's Initial Cell (Information) Rate for the forward direction. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvpcFwdAbrDynTrfcRif | 1.3.6.1.4.1.123.3.82.1.1.1.11 | INTEGER | read-create | ABR traffic Rate Increase Factor for the forward direction. Value is expressed as the -power of 2. Range: 0 - 9 |
| INT nncCrSpvpcFwdAbrDynTrfcRdf | 1.3.6.1.4.1.123.3.82.1.1.1.12 | INTEGER | read-create | ABR traffic Rate Decrease Factor descriptor for the forward direction. Value is expressed as the -power of 2 Range: 0 - 9 |
| INT nncCrSpvpcBwdAbrDynTrfcIcr | 1.3.6.1.4.1.123.3.82.1.1.1.13 | INTEGER | read-create | ABR dynamic traffic descriptor's Initial Cell Rate for the destination endpoint. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvpcBwdAbrDynTrfcRif | 1.3.6.1.4.1.123.3.82.1.1.1.14 | INTEGER | read-create | ABR traffic Rate Increase Factor for the backward direction. Value is expressed as the -power of 2. Range: 0 - 9 |
| INT nncCrSpvpcBwdAbrDynTrfcRdf | 1.3.6.1.4.1.123.3.82.1.1.1.15 | INTEGER | read-create | ABR traffic Rate Decrease Factor descriptor for the backward direction. Value is expressed as the -power of 2 Range: 0 - 9 |
| INT nncCrSpvpcSrcBillingFlag | 1.3.6.1.4.1.123.3.82.1.1.1.16 | INTEGER | read-create | Billing Configuration for the source endpoint |
| INT nncCrSpvpcFwdTmTrafficDescriptor | 1.3.6.1.4.1.123.3.82.1.1.1.17 | INTEGER | read-create | This object contains the traffic descriptor for the SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1 (2) (CBR only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only) |
| INT nncCrSpvpcFwdTmPolicingOption | 1.3.6.1.4.1.123.3.82.1.1.1.18 | INTEGER | read-create | Policing Option for an SPVPC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor |
| INT nncCrSpvpcFwdTmBucketOneRate | 1.3.6.1.4.1.123.3.82.1.1.1.19 | INTEGER | read-create | This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvpcFwdTmBucketOneCdvt | 1.3.6.1.4.1.123.3.82.1.1.1.20 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncCrSpvpcFwdTmBucketTwoRate | 1.3.6.1.4.1.123.3.82.1.1.1.21 | INTEGER | read-create | SIR_0p, SIR_0+1p or MIR_0+1p. This parameter holds the sustained information rate for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvpcFwdTmBucketTwoMbs | 1.3.6.1.4.1.123.3.82.1.1.1.22 | INTEGER | read-create | This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrtVbr and rtVbr only). Range: 1 - 10000 cells |
| INT nncCrSpvpcFwdTmCdv | 1.3.6.1.4.1.123.3.82.1.1.1.23 | INTEGER | read-create | This value is to set the cell delay variation (CDV) between two endpoints to support the rt-VBR service category. Range: 250-10000 microseconds |
| INT nncCrSpvpcFwdTmClr | 1.3.6.1.4.1.123.3.82.1.1.1.24 | INTEGER | read-create | The object is to set the cell loss ratio (CLR) between two SPVC endpoints when using the nrt-VBR service category. Value set as 1.0e-# |
| INT nncCrSpvpcBwdTmTrafficDescriptor | 1.3.6.1.4.1.123.3.82.1.1.1.25 | INTEGER | read-create | This object contains the traffic descriptor for the SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1 (2) (CBR only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only) |
| INT nncCrSpvpcBwdTmPolicingOption | 1.3.6.1.4.1.123.3.82.1.1.1.26 | INTEGER | read-create | Policing Option for an SPVPC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor |
| INT nncCrSpvpcBwdTmBucketOneRate | 1.3.6.1.4.1.123.3.82.1.1.1.27 | INTEGER | read-create | This object is for peak information rate (PIR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvpcBwdTmBucketOneCdvt | 1.3.6.1.4.1.123.3.82.1.1.1.28 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncCrSpvpcBwdTmBucketTwoRate | 1.3.6.1.4.1.123.3.82.1.1.1.29 | INTEGER | read-create | SIR_0p, SIR_0+1p or MIR_0+1p. This parameter holds the sustained information rate for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvpcBwdTmBucketTwoMbs | 1.3.6.1.4.1.123.3.82.1.1.1.30 | INTEGER | read-create | This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrtVbr and rtVbr only). Range: 1 - 10000 cells |
| INT nncCrSpvpcBwdTmCdv | 1.3.6.1.4.1.123.3.82.1.1.1.31 | INTEGER | read-create | This value is to set the cell delay variation (CDV) between two endpoints to support the rt-VBR service category. Range: 250-10000 microseconds |
| INT nncCrSpvpcBwdTmClr | 1.3.6.1.4.1.123.3.82.1.1.1.32 | INTEGER | read-create | The object is to set the cell loss ratio (CLR) between two SPVC endpoints when using the nrt-VBR service category. Value set as 1.0e-# |
| INT nncCrSpvpcCreator | 1.3.6.1.4.1.123.3.82.1.1.1.33 | INTEGER | read-only | The object retrieves the creator of a SPVC connection. |
| ROW nncCrSpvpcRowStatus | 1.3.6.1.4.1.123.3.82.1.1.1.34 | RowStatus | read-create | This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy' |
| nncCrSpvpcDstCfgTable | 1.3.6.1.4.1.123.3.82.1.2 | not-accessible | the nncCrSpvpcDstCfg table contains common objects used to configure, delete, modify and query the destination end point of an SPVC across different Alcatel CID platforms. | |
| nncCrSpvpcDstCfgTableEntry | 1.3.6.1.4.1.123.3.82.1.2.1 | not-accessible | An entry of nncCrSpvpcDstCfgTable. | |
| INT nncCrSpvpcDstCfgCdvt | 1.3.6.1.4.1.123.3.82.1.2.1.1 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncCrSpvpcDstCfgPolicing | 1.3.6.1.4.1.123.3.82.1.2.1.2 | INTEGER | read-create | CR Policing |
| INT nncCrSpvpcDstCfgBillingFlag | 1.3.6.1.4.1.123.3.82.1.2.1.3 | INTEGER | read-create | Billing Configuration for the destination endpoint. |
| INT nncCrSpvpcDstCfgLocRerouteConfig | 1.3.6.1.4.1.123.3.82.1.2.1.4 | INTEGER | read-create | This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled. |
| ROW nncCrSpvpcDstCfgRowStatus | 1.3.6.1.4.1.123.3.82.1.2.1.5 | RowStatus | read-create | This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy' |
| nncCrSpvccTable | 1.3.6.1.4.1.123.3.82.1.3 | not-accessible | nncCrSpvccTable contains all the objects sent to a source endpoint that are used to create, modify, delete and query Cell Relay SPVC connections. | |
| nncCrSpvccTableEntry | 1.3.6.1.4.1.123.3.82.1.3.1 | not-accessible | An entry of nncCrSpvccTable. It contains the objects required to manage CR SPVCs. | |
| INT nncCrSpvccServiceCategory | 1.3.6.1.4.1.123.3.82.1.3.1.1 | INTEGER | read-create | This object is used to set the traffic service category. This object is dependent on the value specified in nncCrSpvccTrafficDescriptor |
| ATM nncCrSpvccTargEpAddr | 1.3.6.1.4.1.123.3.82.1.3.1.2 | AtmFormatDisplay | read-create | This object is used to specify the AESA address for the target endpoint. The mapping scheme is as follows: Byte\Bit 8 7 6 5 4 3 2 1 ------------------------------------------------------------------------ 1-13 byte | 13-byte Internal Subscriber Prefix | ------------------------------------------------------------------------ 14th byte | I/G | U/L | OUI(most significant 6 bits) | ------------------------------------------------------------------------ 15th byte | OUI(2nd most significant 8 bits | ------------------------------------------------------------------------ 16th byte | OUI(3rd most significant 8 bits | ------------------------------------------------------------------------ 17th byte | Shelf/Slot(1st most significant 8 bits | ------------------------------------------------------------------------ 18th byte | Shelf/Slot(2nd most significant 8 bits | ------------------------------------------------------------------------ 19th byte |Flag0| Port | ------------------------------------------------------------------------ 20th byte | 0 | ------------------------------------------------------------------------ |
| INT nncCrSpvccTargVpi | 1.3.6.1.4.1.123.3.82.1.3.1.3 | INTEGER | read-create | This object contains the virtual path identifier (VPI) value for the target endpoint. Range: 0 - 4095 |
| INT nncCrSpvccTargVci | 1.3.6.1.4.1.123.3.82.1.3.1.4 | INTEGER | read-create | This object contains the virtual channel identifier (VCI) value for the target endpoint. Range: 1 - 65535 |
| INT nncCrSpvccTargDlci | 1.3.6.1.4.1.123.3.82.1.3.1.5 | INTEGER | not-accessible | This object contains the data link connection identifier for a frame relay endpoint. This number is used to identify the target endpoint, and has only local significance to the specified link. Range: 16 - 1023 |
| INT nncCrSpvccTargCeNumber | 1.3.6.1.4.1.123.3.82.1.3.1.6 | INTEGER | not-accessible | This object contains circuit number, channel group number or both for the Circuit Emulation endpoint. Used in CR to CE connections when nncCrSpvccTargEpType is configured as circuitEmulation(3). For CE connections on unchannelized DS3_CCE card, it's the circuit number 1-28 for UDT circuit number For CE connections on unchannelized E3_CCE card, it's the circuit number 1-16 for UDT circuit number For CE connections on E1/T1 CES, it's channel group number. 0 for UDT mode, both T1 and E1 1-31 for E1 in SDT mode 1-24 for T1 in SDT mode For CE connections on channelized DS3_CCE-2 card, it's circuit number and channel group number combined in the upper and lower byte. circuitNum (bits 9-16, = 1 to 28 for channelized DS3, = 0 for unstructured DS3) channelGroupNum (bits 1-8, = 1 to 24 for SDT mode, = 0 for UDT Mode) For CE connections on channelized E3_CCE-2, it's circuit number and channel group number combined in the upper and lower byte. circuitNum (bits 9-16, = 1 to 16) channelGroupNum (bits 1-8, = 1 to 31 for SDT mode, = 0 for UDT Mode) Example: Circuit Number = 7, Channel Group = 3 : nncCrSpvccTargCeNumber = (Circuit Number * 256) + Channel Group = 1795 SPVCs across service types other than circuit emulation do not require this object. |
| INT nncCrSpvccTargEpType | 1.3.6.1.4.1.123.3.82.1.3.1.7 | INTEGER | read-create | This object specifies a target endpoint as one of the following types: cellRelay (1) frameRelay (2) circuitEmulation (3) |
| INT nncCrSpvccAdminStatus | 1.3.6.1.4.1.123.3.82.1.3.1.8 | INTEGER | read-create | This object accepts two values, enabled (1), and disabled (2). When the value is disabled, the SPVC is not connected. When enabled, the SPVC is connected when possible. Use nncCrSpvccAdminStatus to determine if the connection is successful. |
| INT nncCrSpvccPriority | 1.3.6.1.4.1.123.3.82.1.3.1.9 | INTEGER | read-create | This object is used to set the priority for a SPVC connection request. It ranges between 1-16, with the following values: Best Priority = 1 Default Priority = 3 Worst Priority = 16 |
| I32 nncCrSpvccMaxAdminWeight | 1.3.6.1.4.1.123.3.82.1.3.1.10 | Integer32 | read-create | This object is used to set a cost threshold for an SPVC connection. If the total cost of all VPCs exceeds this weight value for a given path, this SPVC will choose an alternative path or give up. Infinite = -1 Min Admin Weight = 0 Max Admin Weight = 2147483647 |
| INT nncCrSpvccOperation | 1.3.6.1.4.1.123.3.82.1.3.1.11 | INTEGER | read-create | This object is used to request a reroute operation. Querying this object will not provide any useful information. |
| INT nncCrSpvccCallStatus | 1.3.6.1.4.1.123.3.82.1.3.1.12 | INTEGER | read-only | This read-only object is used to query the state of a particular SPVC. SPVCs that are connected and operational will return a value of 'connected', while those that are incomplete or otherwise unable to be connected will return 'waitingForResources'. SPVCs that are configured but not yet connected will contain a value of 'readyForConnect'. |
| INT nncCrSpvccLocRerouteConfig | 1.3.6.1.4.1.123.3.82.1.3.1.13 | INTEGER | read-create | This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled. |
| INT nncCrSpvccFwdAbrDynTrfcIcr | 1.3.6.1.4.1.123.3.82.1.3.1.14 | INTEGER | read-create | ABR dynamic traffic descriptor's Initial Cell Rate for the forward direction. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvccFwdAbrDynTrfcRif | 1.3.6.1.4.1.123.3.82.1.3.1.15 | INTEGER | read-create | ABR traffic Rate Increase Factor for the forward direction. Value is expressed as the -power of 2. Range: 0 - 9 |
| INT nncCrSpvccFwdAbrDynTrfcRdf | 1.3.6.1.4.1.123.3.82.1.3.1.16 | INTEGER | read-create | ABR traffic Rate Decrease Factor descriptor for the forward direction. Value is expressed as the -power of 2 Range: 0 - 9 |
| INT nncCrSpvccBwdAbrDynTrfcIcr | 1.3.6.1.4.1.123.3.82.1.3.1.17 | INTEGER | read-create | ABR dynamic traffic descriptor's Initial Cell Rate for the destination endpoint. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvccBwdAbrDynTrfcRif | 1.3.6.1.4.1.123.3.82.1.3.1.18 | INTEGER | read-create | ABR traffic Rate Increase Factor for the backward direction. Value is expressed as the -power of 2. Range: 0 - 9 |
| INT nncCrSpvccBwdAbrDynTrfcRdf | 1.3.6.1.4.1.123.3.82.1.3.1.19 | INTEGER | read-create | ABR traffic Rate Decrease Factor descriptor for the backward direction. Value is expressed as the -power of 2 Range: 0 - 9 |
| INT nncCrSpvccSrcBillingFlag | 1.3.6.1.4.1.123.3.82.1.3.1.20 | INTEGER | read-create | Billing Configuration for the source endpoint |
| INT nncCrSpvccFwdTmTrafficDescriptor | 1.3.6.1.4.1.123.3.82.1.3.1.21 | INTEGER | read-create | This object contains the traffic descriptor for the SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1 (2) (CBR only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only) |
| INT nncCrSpvccFwdTmPolicingOption | 1.3.6.1.4.1.123.3.82.1.3.1.22 | INTEGER | read-create | Policing Option for an SPVCC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor |
| INT nncCrSpvccFwdTmBucketOneRate | 1.3.6.1.4.1.123.3.82.1.3.1.23 | INTEGER | read-create | This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvccFwdTmBucketOneCdvt | 1.3.6.1.4.1.123.3.82.1.3.1.24 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncCrSpvccFwdTmBucketTwoRate | 1.3.6.1.4.1.123.3.82.1.3.1.25 | INTEGER | read-create | SIR_0p, SIR_0+1p or MIR_0+1p. This parameter holds the sustained information rate for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvccFwdTmBucketTwoMbs | 1.3.6.1.4.1.123.3.82.1.3.1.26 | INTEGER | read-create | This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrtVbr and rtVbr only). Range: 1 - 10000 cells |
| INT nncCrSpvccFwdTmCdv | 1.3.6.1.4.1.123.3.82.1.3.1.27 | INTEGER | read-create | This value is to set the cell delay variation (CDV) between two endpoints to support the rt-VBR service category. Range: 250-10000 microseconds |
| INT nncCrSpvccFwdTmClr | 1.3.6.1.4.1.123.3.82.1.3.1.28 | INTEGER | read-create | The object is to set the cell loss ratio (CLR) between two SPVC endpoints when using the nrt-VBR service category. Value set as 1.0e-# |
| INT nncCrSpvccFwdTmFrameDiscard | 1.3.6.1.4.1.123.3.82.1.3.1.29 | INTEGER | read-create | The Frame (AAL protocol data unit) Discard option. When enabled, cells are discarded at the frame level by examining the SDU-type in the payload type field of the ATM cell header. |
| INT nncCrSpvccBwdTmTrafficDescriptor | 1.3.6.1.4.1.123.3.82.1.3.1.30 | INTEGER | read-create | This object contains the traffic descriptor for the SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1 (2) (CBR only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only) |
| INT nncCrSpvccBwdTmPolicingOption | 1.3.6.1.4.1.123.3.82.1.3.1.31 | INTEGER | read-create | Policing Option for an SPVCC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor |
| INT nncCrSpvccBwdTmBucketOneRate | 1.3.6.1.4.1.123.3.82.1.3.1.32 | INTEGER | read-create | This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvccBwdTmBucketOneCdvt | 1.3.6.1.4.1.123.3.82.1.3.1.33 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncCrSpvccBwdTmBucketTwoRate | 1.3.6.1.4.1.123.3.82.1.3.1.34 | INTEGER | read-create | SIR_0p, SIR_0+1p or MIR_0+1p. This parameter holds the sustained information rate for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s |
| INT nncCrSpvccBwdTmBucketTwoMbs | 1.3.6.1.4.1.123.3.82.1.3.1.35 | INTEGER | read-create | This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrt-VBR and rt-VBR only). Range: 1 - 10000 cells |
| INT nncCrSpvccBwdTmCdv | 1.3.6.1.4.1.123.3.82.1.3.1.36 | INTEGER | read-create | This value is to set the cell delay variation (CDV) between two endpoints to support the rt-VBR service category. Range: 250-10000 microseconds |
| INT nncCrSpvccBwdTmClr | 1.3.6.1.4.1.123.3.82.1.3.1.37 | INTEGER | read-create | The object is to set the cell loss ratio (CLR) between two SPVC endpoints when using the nrt-VBR service category. Value set as 1.0e-# |
| INT nncCrSpvccBwdTmFrameDiscard | 1.3.6.1.4.1.123.3.82.1.3.1.38 | INTEGER | read-create | The Frame (AAL protocol data unit) Discard option. When enabled, cells are discarded at the frame level by examining the SDU-type in the payload type field of the ATM cell header. |
| INT nncCrSpvccFrBwdTmAr | 1.3.6.1.4.1.123.3.82.1.3.1.39 | INTEGER | read-create | This object is used to specify the Access Rate, in Kb/s. |
| INT nncCrSpvccFrBwdTmCir | 1.3.6.1.4.1.123.3.82.1.3.1.40 | INTEGER | read-create | The committed Information Rate, in Kb/s. |
| INT nncCrSpvccFrBwdTmBc | 1.3.6.1.4.1.123.3.82.1.3.1.41 | INTEGER | read-create | The Committed Burst Size, in Kb. |
| INT nncCrSpvccFrBwdTmBe | 1.3.6.1.4.1.123.3.82.1.3.1.42 | INTEGER | read-create | The Excess Burst Size, in Kb. |
| INT nncCrSpvccFrBwdTmIwf | 1.3.6.1.4.1.123.3.82.1.3.1.43 | INTEGER | read-create | Interworking Function. Values: none (None (FR Switching) = 0) networkInterworking (Network Interworking = 2) serviceInterworking (Service Interworking = 3) FFwd Interworking (FFwd Interworking = 4) |
| INT nncCrSpvccFrBwdTmPo | 1.3.6.1.4.1.123.3.82.1.3.1.44 | INTEGER | read-create | Policing |
| INT nncCrSpvccFrBwdTmPacing | 1.3.6.1.4.1.123.3.82.1.3.1.45 | INTEGER | read-create | Pacing |
| INT nncCrSpvccFrBwdTmPtclMapping | 1.3.6.1.4.1.123.3.82.1.3.1.46 | INTEGER | read-create | Protocol Mapping for Service Interworking SPVCs. If Translated Service Interworking is selected, the a profile must be set using the attribute nncFrSpvcTmSIWProfile. Values: transparent (0), translated (1) (see also nncFrSpvcTmSIWProfile) |
| INT nncCrSpvccFrBwdTmClpMapping | 1.3.6.1.4.1.123.3.82.1.3.1.47 | INTEGER | read-create | Cell Loss Priority Mapping. Values: cLPEqualsDE (CLP = DE, 0) cLPEquals0 (CLP = 0, 1 ) cLPEquals1 (CLP = 1, 2 ) |
| INT nncCrSpvccFrBwdTmDeMapping | 1.3.6.1.4.1.123.3.82.1.3.1.48 | INTEGER | read-create | Discard Eligibility Mapping Values: dEEqualsCLP (DE = CLP, 0) dESSCSor0 (Network Interworking: DE=FR_SSCS Service Interworking: DE=0, 1) dEEquals1 (Service Interworking: DE = 1, 2) Only the first two values are valid when using Network Interworking. |
| INT nncCrSpvccFrBwdTmEfciMapping | 1.3.6.1.4.1.123.3.82.1.3.1.49 | INTEGER | read-create | Explicit Forward Congestion Indication Mapping (Applies only to Service Interworking (IWF3), FR to ATM) Values: eFCIEqualsFECN (EFCI = FECN, 0) eFCIEquals0 (EFCI = 0, 1) |
| INT nncCrSpvccFrBwdTmPvcMgntProfile | 1.3.6.1.4.1.123.3.82.1.3.1.50 | INTEGER | read-create | Enables or disables the PVC Management Profile. When enabled, LMI is enabled on the network-side of the connection. Used only with FR-CR network interworking selected. |
| INT nncCrSpvccFrBwdTmSIWProfile | 1.3.6.1.4.1.123.3.82.1.3.1.51 | INTEGER | read-create | The FR-CR profile index for service interworking connections. This attribute is used to define the translation profile to use when a FR to CR SPVC is configured for Translated Service Interworking (using the attributes nncFrSpvcTmIwf and nncFrSpvcTmPtclMapping). If the profile selected isn't defined on the remote node then the connection will be rejected. Range: 1 = 16. |
| INT nncCrSpvccCreator | 1.3.6.1.4.1.123.3.82.1.3.1.52 | INTEGER | read-only | The object retrieves the creator of a SPVC connection. |
| ROW nncCrSpvccRowStatus | 1.3.6.1.4.1.123.3.82.1.3.1.53 | RowStatus | read-create | This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy' |
| nncCrSpvccDstCfgTable | 1.3.6.1.4.1.123.3.82.1.4 | not-accessible | the nncCrSpvccDstCfg table contains common objects used to configure, delete, modify and query the destination end point of an SPVC across different Alcatel CID platforms. | |
| nncCrSpvccDstCfgTableEntry | 1.3.6.1.4.1.123.3.82.1.4.1 | not-accessible | An entry of nncCrSpvccDstCfgTable. | |
| INT nncCrSpvccDstCfgCdvt | 1.3.6.1.4.1.123.3.82.1.4.1.1 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncCrSpvccDstCfgPolicing | 1.3.6.1.4.1.123.3.82.1.4.1.2 | INTEGER | read-create | CR Policing |
| INT nncCrSpvccDstCfgBillingFlag | 1.3.6.1.4.1.123.3.82.1.4.1.3 | INTEGER | read-create | Billing Configuration for the destination endpoint |
| INT nncCrSpvccDstCfgFrVsvdCongestionControl | 1.3.6.1.4.1.123.3.82.1.4.1.4 | INTEGER | read-create | Congestion Control for VS/VD endpoints, also known as Closed Loop Congestion Control (CLCC). |
| INT nncCrSpvccDstCfgLocRerouteConfig | 1.3.6.1.4.1.123.3.82.1.4.1.5 | INTEGER | read-create | This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled. |
| ROW nncCrSpvccDstCfgRowStatus | 1.3.6.1.4.1.123.3.82.1.4.1.6 | RowStatus | read-create | This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy' |
| nncFrSpvcTable | 1.3.6.1.4.1.123.3.82.1.5 | not-accessible | nncFrSpvcTable contains all the objects sent to a source endpoint that are used to create, modify, delete and query FR SPVCCs. | |
| nncFrSpvcTableEntry | 1.3.6.1.4.1.123.3.82.1.5.1 | not-accessible | An entry of nncFrSpvcTable. | |
| INT nncFrSpvcSrcDlci | 1.3.6.1.4.1.123.3.82.1.5.1.1 | INTEGER | not-accessible | This object contains the data link connection identifier for a frame relay endpoint. This number is used to identify the source endpoint, and has only local significance to the specified link. Range: 16 - 1023 |
| ATM nncFrSpvcTargEpAddr | 1.3.6.1.4.1.123.3.82.1.5.1.2 | AtmFormatDisplay | read-create | This object contains the target endpoint's 20-byte ATM End System Address (AESA) proposed by ATM Forum. An endpoint address is created by appending the switch-wide 13-byte Internal Switch Subscriber Address Prefix with a 6-byte End Station Identifier (ESI) followed by a selector byte. The ESI is in IEEE MAC address format and the exact form depends upon the destination endpoint and the SPVC commissioning method. The mapping scheme is as follows: Byte\Bit 8 7 6 5 4 3 2 1 ------------------------------------------------------------------------ 1-13 byte | 13-byte Internal Subscriber Prefix | ------------------------------------------------------------------------ 14th byte | I/G | U/L | OUI(most significant 6 bits) | ------------------------------------------------------------------------ 15th byte | OUI(2nd most significant 8 bits | ------------------------------------------------------------------------ 16th byte | OUI(3rd most significant 8 bits | ------------------------------------------------------------------------ 17th byte | Shelf/Slot(1st most significant 8 bits | ------------------------------------------------------------------------ 18th byte | Shelf/Slot(2nd most significant 8 bits | ------------------------------------------------------------------------ 19th byte |Flag1| Port | Circuit | ------------------------------------------------------------------------ 20th byte |Circuit(continued) | Stream | ------------------------------------------------------------------------ |
| INT nncFrSpvcTargDlci | 1.3.6.1.4.1.123.3.82.1.5.1.3 | INTEGER | read-create | This object contains the data link connection identifier for a frame relay endpoint. This number is used to identify the target endpoint, and has only local significance to the specified link. Range: 16 - 1023 |
| INT nncFrSpvcTargVpi | 1.3.6.1.4.1.123.3.82.1.5.1.4 | INTEGER | read-create | This object contains the virtual path identifier (VPI) value for the Cell Relay based target endpoint. Range: 0 - 4095 |
| INT nncFrSpvcTargVci | 1.3.6.1.4.1.123.3.82.1.5.1.5 | INTEGER | read-create | This object contains the virtual channel identifier (VCI) value for the cell-relay based target endpoint. Range: 1 - 65535 |
| INT nncFrSpvcTargEpType | 1.3.6.1.4.1.123.3.82.1.5.1.6 | INTEGER | read-create | This object specifies a target endpoint as one of the following types: cellRelay (1) frameRelay (2) |
| INT nncFrSpvcAdminStatus | 1.3.6.1.4.1.123.3.82.1.5.1.7 | INTEGER | read-create | This object accepts two values, enabled (1), and disabled (2). When the value is disabled, the SPVC is not connected. When enabled, the SPVC is connected when possible. Use nncFrSpvcAdminStatus to determine if the connection is successful. |
| INT nncFrSpvcPriority | 1.3.6.1.4.1.123.3.82.1.5.1.8 | INTEGER | read-create | This object is used to set the priority for a SPVC connection request. It ranges between 1-16, with the following values: Best Priority = 1 Default Priority = 3 Worst Priority = 16 |
| I32 nncFrSpvcMaxAdminWeight | 1.3.6.1.4.1.123.3.82.1.5.1.9 | Integer32 | read-create | This object is used to set a cost threshold for an SPVC connection. If the total cost of all VPCs exceeds this weight value for a given path, this SPVC will choose an alternative path or give up. Infinite = -1 Min Admin Weight = 0 Max Admin Weight = 2147483647 |
| INT nncFrSpvcOperation | 1.3.6.1.4.1.123.3.82.1.5.1.10 | INTEGER | read-create | This object is used to request a reroute operation. Querying this object will not provide any useful information. |
| INT nncFrSpvcCallStatus | 1.3.6.1.4.1.123.3.82.1.5.1.11 | INTEGER | read-only | This read-only object is used to query the state of a particular SPVC. SPVCs that are connected and operational will return a value of 'connected', while those that are incomplete or otherwise unable to be connected will return 'waitingForResources'. SPVCs that are configured but not yet connected will contain a value of 'readyForConnect'. |
| INT nncFrSpvcLocRerouteConfig | 1.3.6.1.4.1.123.3.82.1.5.1.12 | INTEGER | read-create | This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled. |
| INT nncFrSpvcSrcBillingFlag | 1.3.6.1.4.1.123.3.82.1.5.1.13 | INTEGER | read-create | Billing Configuration for the source endpoint. |
| INT nncFrSpvcFrPriority | 1.3.6.1.4.1.123.3.82.1.5.1.14 | INTEGER | read-create | Frame Relay Priority. |
| INT nncFrSpvcFrVsvdCongestionControl | 1.3.6.1.4.1.123.3.82.1.5.1.15 | INTEGER | read-create | Congestion Control for VS/VD endpoints, also known as Closed Loop Congestion Control (CLCC). |
| INT nncFrSpvcFwdFrMir | 1.3.6.1.4.1.123.3.82.1.5.1.16 | INTEGER | read-create | The FR Src->Dst Minimum Information Rate, used to set the minimum rate on a CLCC FR-FR SPVC connection. If nncFrSpvcFrVsvdCongestionControl is not enabled, this attribute has no effect. Range: 0 - 44210 Kb/s |
| INT nncFrSpvcFwdTmAr | 1.3.6.1.4.1.123.3.82.1.5.1.17 | INTEGER | read-create | This object is used to specify the Access Rate, in Kb/s |
| INT nncFrSpvcFwdTmCir | 1.3.6.1.4.1.123.3.82.1.5.1.18 | INTEGER | read-create | The committed Information Rate, in Kb/s |
| INT nncFrSpvcFwdTmBc | 1.3.6.1.4.1.123.3.82.1.5.1.19 | INTEGER | read-create | The Committed Burst Size, in Kb. |
| INT nncFrSpvcFwdTmBe | 1.3.6.1.4.1.123.3.82.1.5.1.20 | INTEGER | read-create | Excess Burst Size, Kb. |
| INT nncFrSpvcTmIwf | 1.3.6.1.4.1.123.3.82.1.5.1.21 | INTEGER | read-create | Interworking Function. Values: none (None (FR Switching) = 0) networkInterworking (Network Interworking = 2) serviceInterworking (Service Interworking = 3) FFwd Interworking (FFwd Interworking = 4) |
| INT nncFrSpvcFwdTmPo | 1.3.6.1.4.1.123.3.82.1.5.1.22 | INTEGER | read-create | Policing. |
| INT nncFrSpvcFwdTmPacing | 1.3.6.1.4.1.123.3.82.1.5.1.23 | INTEGER | read-create | Pacing. |
| INT nncFrSpvcTmPtclMapping | 1.3.6.1.4.1.123.3.82.1.5.1.24 | INTEGER | read-create | Protocol Mapping for Service Interworking SPVCs. If Translated Service Interworking is selected, the a profile must be set using the attribute nncFrSpvcTmSIWProfile. Values: transparent (0), translated (1) (see also nncFrSpvcTmSIWProfile) |
| INT nncFrSpvcTmClpMapping | 1.3.6.1.4.1.123.3.82.1.5.1.25 | INTEGER | read-create | Cell Loss Priority Mapping, for use in FR-CR interworking SPVCs. Values: cLPEqualsDE (CLP = DE, 0) cLPEquals0 (CLP = 0, 1 ) cLPEquals1 (CLP = 1, 2 ) |
| INT nncFrSpvcTmDeMapping | 1.3.6.1.4.1.123.3.82.1.5.1.26 | INTEGER | read-create | Discard Eligibility Mapping, for use in FR-CR interworking SPVCs. Values: dEEqualsCLP (DE = CLP, 0) dESSCSor0 (Network Interworking: DE=FR_SSCS Service Interworking: DE=0, 1) dEEquals1 (Service Interworking: DE = 1, 2) Only the first two values are valid when using Network Interworking. |
| INT nncFrSpvcTmEfciMapping | 1.3.6.1.4.1.123.3.82.1.5.1.27 | INTEGER | read-create | Explicit Forward Congestion Indication Mapping (Applies only to Service Interworking (IWF3), FR to ATM) Values: eFCIEqualsFECN (EFCI = FECN, 0) eFCIEquals0 (EFCI = 0, 1) |
| INT nncFrSpvcTmPvcMgntProfile | 1.3.6.1.4.1.123.3.82.1.5.1.28 | INTEGER | read-create | Enables or disables the PVC Management Profile. When enabled, LMI is enabled on the network-side of the connection. Used only with FR-CR network interworking selected. |
| INT nncFrSpvcTmSIWProfile | 1.3.6.1.4.1.123.3.82.1.5.1.29 | INTEGER | read-create | The FR-CR profile index for service interworking connections. This attribute is used to define the translation profile to use when a FR to CR SPVC is configured for Translated Service Interworking (using the attributes nncFrSpvcTmIwf and nncFrSpvcTmPtclMapping). If the profile selected isn't defined on the remote node then the connection will be rejected. Range: 1 - 16. |
| INT nncFrSpvcTmRemapDlci | 1.3.6.1.4.1.123.3.82.1.5.1.30 | INTEGER | read-create | The source end-point Data Link Connection Identifier for many-to-one Network Interworking (IWF2) connections. |
| INT nncFrSpvcBwdFrMir | 1.3.6.1.4.1.123.3.82.1.5.1.31 | INTEGER | read-create | The FR Dst->Src Minimum Information Rate, used on CLCC-enabled connections. Range: 0 - 44210 Kb/s |
| INT nncFrSpvcBwdTmAr | 1.3.6.1.4.1.123.3.82.1.5.1.32 | INTEGER | read-create | This object is used to specify the Access Rate, in Kb/s |
| INT nncFrSpvcBwdTmCir | 1.3.6.1.4.1.123.3.82.1.5.1.33 | INTEGER | read-create | The committed Information Rate, in Kb/s |
| INT nncFrSpvcBwdTmBc | 1.3.6.1.4.1.123.3.82.1.5.1.34 | INTEGER | read-create | The Committed Burst Size, in Kb. |
| INT nncFrSpvcBwdTmBe | 1.3.6.1.4.1.123.3.82.1.5.1.35 | INTEGER | read-create | The Excess Burst Size, Kb. |
| INT nncFrSpvcBwdTmPo | 1.3.6.1.4.1.123.3.82.1.5.1.36 | INTEGER | read-create | Policing. |
| INT nncFrSpvcBwdTmPacing | 1.3.6.1.4.1.123.3.82.1.5.1.37 | INTEGER | read-create | Pacing. |
| INT nncFrSpvcCrTmServiceCategory | 1.3.6.1.4.1.123.3.82.1.5.1.38 | INTEGER | read-create | This object is used to set the traffic service category for SPVC Connections. This object is dependent on the value specified in nncFrSpvcCrBwdTmTrafficDescriptor. |
| INT nncFrSpvcCrBwdTmTrafficDescriptor | 1.3.6.1.4.1.123.3.82.1.5.1.39 | INTEGER | read-create | This object contains the CR traffic descriptor for a FR-CR SPVC. Tag All (1) (UBR using 2k/12k fabric only) P_0+1/S_0+1 (3) (NRT/RT-VBR only) P_0+1/S_0 (4) (NRT/RT-VBR only) P_0+1/M_0+1 (5) (ABR and UBR only) |
| INT nncFrSpvcCrBwdTmPolicingOption | 1.3.6.1.4.1.123.3.82.1.5.1.40 | INTEGER | read-create | Policing Option for a FR SPVC. tag is supported only on rt-VBR/nrt-VBR connections that use the P_0+1/S_0 traffic descriptor |
| INT nncFrSpvcCrBwdTmBucketOneRate | 1.3.6.1.4.1.123.3.82.1.5.1.41 | INTEGER | read-create | Used in FR - CR interworking. This object is for peak cell rate (PCR), the cell rate which the cell endpoint may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s |
| INT nncFrSpvcCrBwdTmBucketOneCdvt | 1.3.6.1.4.1.123.3.82.1.5.1.42 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for the CR endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncFrSpvcCrBwdTmBucketTwoRate | 1.3.6.1.4.1.123.3.82.1.5.1.43 | INTEGER | read-create | Used in FR - CR interworking. The attribute contains the SIR_0, SIR_0+1 or MIR_0+1. This parameter holds the sustained information rate (SIR_0 or SIR_0+1) for VBR traffic, and the minimum information rate for ABR/UBR traffic. Range: 0 - 2488320 Kb/s |
| INT nncFrSpvcCrBwdTmBucketTwoMbs | 1.3.6.1.4.1.123.3.82.1.5.1.44 | INTEGER | read-create | This object is for the maximum burst size, in cells, for SIR_0p or SIR_0+1p (nrtVbr and rtVbr only). Range: 1 - 10000 cells |
| INT nncFrSpvcCrBwdTmCdv | 1.3.6.1.4.1.123.3.82.1.5.1.45 | INTEGER | read-create | This value is to set the cell delay variation (CDV) at the CR endpoint. Applicable only when the rt-VBR service category is used. Range: 250-10000 microseconds |
| INT nncFrSpvcCrBwdTmClr | 1.3.6.1.4.1.123.3.82.1.5.1.46 | INTEGER | read-create | The object is to set the cell loss ratio (CLR) at the CR endpoint of a FR-CR SPVC. Valid only when using the nrt-VBR service category. Value set as 1.0e-# |
| INT nncFrSpvcCrBwdTmFrameDiscard | 1.3.6.1.4.1.123.3.82.1.5.1.47 | INTEGER | read-create | The Frame (AAL protocol data unit) Discard option. When enabled, cells are discarded at the frame level by examining the SDU-type in the payload type field of the ATM cell header. |
| INT nncFrSpvcCreator | 1.3.6.1.4.1.123.3.82.1.5.1.48 | INTEGER | read-only | The object retrieves the creator of a given SPVC connection. |
| ROW nncFrSpvcRowStatus | 1.3.6.1.4.1.123.3.82.1.5.1.49 | RowStatus | read-create | This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy' |
| nncFrSpvcDstCfgTable | 1.3.6.1.4.1.123.3.82.1.6 | not-accessible | the nncFrSpvcDstCfg table contains common objects used to configure, delete, modify and query the destination end point of an SPVC across different Alcatel CID platforms. | |
| nncFrSpvcDstCfgTableEntry | 1.3.6.1.4.1.123.3.82.1.6.1 | not-accessible | An entry of nncFrSpvcDstCfgTable. | |
| INT nncFrSpvcDstCfgTmAr | 1.3.6.1.4.1.123.3.82.1.6.1.1 | INTEGER | read-create | This object is used to specify the Access Rate, in Kb/s |
| INT nncFrSpvcDstCfgTmCir | 1.3.6.1.4.1.123.3.82.1.6.1.2 | INTEGER | read-create | The committed Information Rate, Kb/s |
| INT nncFrSpvcDstCfgTmBc | 1.3.6.1.4.1.123.3.82.1.6.1.3 | INTEGER | read-create | The Committed Burst Size, in Kb. |
| INT nncFrSpvcDstCfgTmBe | 1.3.6.1.4.1.123.3.82.1.6.1.4 | INTEGER | read-create | Excess Burst Size, in Kb. |
| INT nncFrSpvcDstCfgTmIwf | 1.3.6.1.4.1.123.3.82.1.6.1.5 | INTEGER | read-create | Interworking Function. Values: none (None (FR Switching) = 0) networkInterworking (Network Interworking = 2) serviceInterworking (Service Interworking = 3) FFwd Interworking (FFwd Interworking = 4) |
| INT nncFrSpvcDstCfgTmPo | 1.3.6.1.4.1.123.3.82.1.6.1.6 | INTEGER | read-create | Policing. |
| INT nncFrSpvcDstCfgTmPacing | 1.3.6.1.4.1.123.3.82.1.6.1.7 | INTEGER | read-create | Pacing. |
| INT nncFrSpvcDstCfgTmPtclMapping | 1.3.6.1.4.1.123.3.82.1.6.1.8 | INTEGER | read-create | Protocol Mapping for Service Interworking SPVCs. If Translated Service Interworking is selected, the a profile must be set using the attribute nncFrSpvcTmPvcMgntProfile. |
| INT nncFrSpvcDstCfgTmClpMapping | 1.3.6.1.4.1.123.3.82.1.6.1.9 | INTEGER | read-create | Cell Loss Priority Mapping. Values: cLPEqualsDE (CLP = DE) cLPEquals0 (CLP = 0 ) cLPEquals1 (CLP = 1 ) |
| INT nncFrSpvcDstCfgTmDeMapping | 1.3.6.1.4.1.123.3.82.1.6.1.10 | INTEGER | read-create | Discard Eligibility Mapping Values: dEEqualsCLP (DE = CLP, 0) dESSCSor0 (Network Interworking: DE=FR_SSCS Service Interworking: DE=0, 1) dEEquals1 (Service Interworking: DE = 1, 2) Only the first two values are valid when using Network Interworking. |
| INT nncFrSpvcDstCfgTmEfciMapping | 1.3.6.1.4.1.123.3.82.1.6.1.11 | INTEGER | read-create | Explicit Forward Congestion Indication Mapping (Applies only to Service Interworking (IWF3), FR to ATM) Values: eFCIEqualsFECN (0) eFCIEquals0 (1) |
| INT nncFrSpvcDstCfgTmPvcMgntProfile | 1.3.6.1.4.1.123.3.82.1.6.1.12 | INTEGER | read-create | Enables or disables the PVC Management Profile. When enabled, LMI is enabled on the network-side of the connection. Used only with FR-CR network interworking selected. |
| INT nncFrSpvcDstCfgTmSIWProfile | 1.3.6.1.4.1.123.3.82.1.6.1.13 | INTEGER | read-create | The FR-CR profile index for service interworking connections. This attribute is used to define the translation profile to use when a FR to CR SPVC is configured for Translated Service Interworking (using the attribute nncFrSpvcTmPtclMapping). If the profile selected isn't defined on the remote node then the connection will be rejected. Range: 1 = 16. |
| INT nncFrSpvcDstCfgTmRemapDlci | 1.3.6.1.4.1.123.3.82.1.6.1.14 | INTEGER | read-create | The source end-point Data Link Connection Identifier for many-to-one Network Interworking (IWF2) connections. |
| INT nncFrSpvcDstCfgBillingFlag | 1.3.6.1.4.1.123.3.82.1.6.1.15 | INTEGER | read-create | Billing Configuration for the destination endpoint. |
| INT nncFrSpvcDstCfgFrPriority | 1.3.6.1.4.1.123.3.82.1.6.1.16 | INTEGER | read-create | Frame Relay Priority. |
| INT nncFrSpvcDstCfgLocRerouteConfig | 1.3.6.1.4.1.123.3.82.1.6.1.17 | INTEGER | read-create | This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled. |
| ROW nncFrSpvcDstCfgRowStatus | 1.3.6.1.4.1.123.3.82.1.6.1.18 | RowStatus | read-create | This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy' |
| nncCeSpvcTable | 1.3.6.1.4.1.123.3.82.1.7 | not-accessible | nncCeSpvcTable contains all the objects sent to a source endpoint that are used to create, modify, delete and query CE SPVCCs. The table is indexed using ifIndex, which includes the circuit number field. | |
| nncCeSpvcTableEntry | 1.3.6.1.4.1.123.3.82.1.7.1 | not-accessible | An entry of nncCeSpvcTable. | |
| ATM nncCeSpvcTargEpAddr | 1.3.6.1.4.1.123.3.82.1.7.1.1 | AtmFormatDisplay | read-create | This object is used to specify the AESA address of the target endpoint. The mapping scheme is as follows: Byte\Bit 8 7 6 5 4 3 2 1 ------------------------------------------------------------------------ 1-13 byte | 13-byte Internal Subscriber Prefix | ------------------------------------------------------------------------ 14th byte | I/G | U/L | OUI(most significant 6 bits) | ------------------------------------------------------------------------ 15th byte | OUI(2nd most significant 8 bits | ------------------------------------------------------------------------ 16th byte | OUI(3rd most significant 8 bits | ------------------------------------------------------------------------ 17th byte | Shelf/Slot(1st most significant 8 bits | ------------------------------------------------------------------------ 18th byte | Shelf/Slot(2nd most significant 8 bits | ------------------------------------------------------------------------ 19th byte |Flag0| Port | ------------------------------------------------------------------------ 20th byte | Not used, default 0 | ------------------------------------------------------------------------ |
| INT nncCeSpvcTargVpi | 1.3.6.1.4.1.123.3.82.1.7.1.2 | INTEGER | read-create | This object contains the virtual path identifier (VPI) value for the target endpoint. Used in interworking CE to CR connections when nncCeSpvcTargEpType configured as cellRelay(1). Range: 0 - 4095 |
| INT nncCeSpvcTargVci | 1.3.6.1.4.1.123.3.82.1.7.1.3 | INTEGER | read-create | This object contains the virtual channel identifier (VCI) value for the target endpoint. Used in interworking CE to CR connections when nncCeSpvcTargEpType configured as cellRelay(1). Range: 1 - 65535 |
| INT nncCeSpvcTargCeNumber | 1.3.6.1.4.1.123.3.82.1.7.1.4 | INTEGER | read-create | This object contains circuit number, channel group number or both for the Circuit Emulation endpoint. Used in CE to CE connections when nncCrSpvccTargEpType is configured as circuitEmulation(3). For CE connections on unchannelized DS3_CCE card, it's the circuit number 1-28 for UDT circuit number For CE connections on unchannelized E3_CCE card, it's the circuit number 1-16 for UDT circuit number For CE connections on E1/T1 CES, it's channel group number. 0 for UDT mode, both T1 and E1 1-31 for E1 in SDT mode 1-24 for T1 in SDT mode For CE connections on channelized DS3_CCE-2 card, it's circuit number and channel group number combined in the upper and lower byte. circuitNum (bits 9-16, = 1 to 28 for channelized DS3, = 0 for unstructured DS3) channelGroupNum (bits 1-8, = 1 to 24 for SDT mode, = 0 for UDT Mode) For CE connections on channelized E3_CCE-2, it's circuit number and channel group number combined in the upper and lower byte. circuitNum (bits 9-16, = 1 to 16) channelGroupNum (bits 1-8, = 1 to 31 for SDT mode, = 0 for UDT Mode) Example: Circuit Number = 7, Channel Group = 3 : nncCrSpvccTargCeNumber = (Circuit Number * 256) + Channel Group = 1795 SPVCs across service types other than circuit emulation do not require this object. |
| INT nncCeSpvcTargEpType | 1.3.6.1.4.1.123.3.82.1.7.1.5 | INTEGER | read-create | This object specifies a target endpoint as one of the following types: cellRelay (1) circuitEmulation (3) |
| INT nncCeSpvcAdminStatus | 1.3.6.1.4.1.123.3.82.1.7.1.6 | INTEGER | read-create | This object accepts two values, enabled (1), and disabled (2). When the value is disabled, the SPVC is not connected. When enabled, the SPVC is connected when possible. Use nncCeSpvcAdminStatus to determine if the connection is successful. |
| INT nncCeSpvcPriority | 1.3.6.1.4.1.123.3.82.1.7.1.7 | INTEGER | read-create | This object is used to set the priority for a SPVC connection request. It ranges between 1-16, with the following values: Best Priority = 1 Default Priority = 3 Worst Priority = 16 |
| I32 nncCeSpvcMaxAdminWeight | 1.3.6.1.4.1.123.3.82.1.7.1.8 | Integer32 | read-create | This object is used to set a cost threshold for an SPVC connection. If the total cost of all VPCs exceeds this weight value for a given path, this SPVC will choose an alternative path or give up. Infinite = -1 Min Admin Weight = 0 Max Admin Weight = 2147483647 |
| INT nncCeSpvcOperation | 1.3.6.1.4.1.123.3.82.1.7.1.9 | INTEGER | read-create | This object is used to request a reroute operation. Querying this object will not provide any useful information. |
| INT nncCeSpvcCallStatus | 1.3.6.1.4.1.123.3.82.1.7.1.10 | INTEGER | read-only | This read-only object is used to query the state of a particular SPVC. SPVCs that are connected and operational will return a value of 'connected', while those that are incomplete or otherwise unable to be connected will return 'waitingForResources'. SPVCs that are configured but not yet connected will contain a value of 'readyForConnect'. |
| INT nncCeSpvcLocRerouteConfig | 1.3.6.1.4.1.123.3.82.1.7.1.11 | INTEGER | read-create | This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. For circuit emulation UNI side is not supported. It can be configured for either NNI side or disabled. |
| INT nncCeSpvcFwdTmBucketOneRate | 1.3.6.1.4.1.123.3.82.1.7.1.12 | INTEGER | read-create | This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s For N x DS0 SDT Basic connections = ((((1 + 1.0 / 128) * 8 * N / K) + (1.0/1000)) * 53.0 * 8.0) where N = 1..24 for T1 N = 1..31 for E1 K = 1..47 is the number of data octets per cell. For N x DS0 SDT CAS connections = ((((1 + 1.0 / 128) * 8 * (((Cn * N) + (N % 2)) / (Ck * K))) + (1.0/1000)) * 53.0 * 8.0) where N = 1..24 for T1 N = 1..31 for E1 K = 2..47 is the number of data octets per cell. Cn = 49 for T1 Cn = 33 for E1 Ck = 48 for T1 Ck = 32 for E1 = 1755 Kb/s for T1,DS1 UDT connections = 2328 Kb/s for E1 UDT connections = 50842 Kb/s for DS3 UDT connections |
| INT nncCeSpvcFwdTmBucketOneCdvt | 1.3.6.1.4.1.123.3.82.1.7.1.13 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncCeSpvcBwdTmBucketOneRate | 1.3.6.1.4.1.123.3.82.1.7.1.14 | INTEGER | read-create | This object is for peak cell rate (PCR), the cell rate which the source may never exceed. It is used to determine which cells are 'excess'. Measured in Kb/s. Range: 0 - 2488320 Kb/s For N x DS0 SDT Basic connections = ((((1 + 1.0 / 128) * 8 * N / K) + (1.0/1000)) * 53.0 * 8.0) where N = 1..24 for T1 N = 1..31 for E1 K = 1..47 is the number of data octets per cell. For N x DS0 SDT CAS connections = ((((1 + 1.0 / 128) * 8 * (((Cn * N) + (N % 2)) / (Ck * K))) + (1.0/1000)) * 53.0 * 8.0) where N = 1..24 for T1 N = 1..31 for E1 K = 2..47 is the number of data octets per cell. Cn = 49 for T1 Cn = 33 for E1 Ck = 48 for T1 Ck = 32 for E1 = 1755 Kb/s for T1,DS1 UDT connections = 2328 Kb/s for E1 UDT connections = 50842 Kb/s for DS3 UDT connections |
| INT nncCeSpvcBwdTmBucketOneCdvt | 1.3.6.1.4.1.123.3.82.1.7.1.15 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncCeSpvcCreator | 1.3.6.1.4.1.123.3.82.1.7.1.16 | INTEGER | read-only | The object retrieves the creator of a SPVC connection. |
| ROW nncCeSpvcRowStatus | 1.3.6.1.4.1.123.3.82.1.7.1.17 | RowStatus | read-create | This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy' |
| nncCeSpvcDstCfgTable | 1.3.6.1.4.1.123.3.82.1.8 | not-accessible | the nncCeSpvcDstCfg table contains common objects used to configure, delete, modify and query the destination end point of an SPVC across different Alcatel CID platforms. | |
| nncCeSpvcDstCfgTableEntry | 1.3.6.1.4.1.123.3.82.1.8.1 | not-accessible | An entry of nncCeSpvcDstCfgTable. | |
| INT nncCeSpvcDstCfgCdvt | 1.3.6.1.4.1.123.3.82.1.8.1.1 | INTEGER | read-create | This object is used to set cell delay variation tolerance (CDVT) for one endpoint, measured in microseconds. Range: 1 - 190,000 microseconds |
| INT nncCeSpvcDstCfgLocRerouteConfig | 1.3.6.1.4.1.123.3.82.1.8.1.2 | INTEGER | read-create | This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. For circuit emulation UNI side is not supported. It can be configured for either NNI side or disabled. |
| ROW nncCeSpvcDstCfgRowStatus | 1.3.6.1.4.1.123.3.82.1.8.1.3 | RowStatus | read-create | This object is used to control the status of a PDU and to query the status of an SPVC. When the RowStatus value is 'createAndWait', information for a row is cached in memory; when RowStatus is set to 'createAndGo' or 'active', it indicates that all information is to be written to permanent storage, and the SPVC to be enabled (AdminStatus must also be set to 'enabled'). When querying the object, 'active' indicates a configured SPVC with its AdminStatus enabled, while a status of 'notInService' indicates either a disabled AdminStatus or an inability to connect the SPVC. If a query returns 'notInService', use the CallStatus object to further determine the state of the SPVC. If the value 'notReady' is returned, it indicates that the SNMP agent is awaiting further information before activating the connection. When deleting a connection, use this object with the value 'destroy' |
| nncExtSpvcGroups | 1.3.6.1.4.1.123.3.82.3 | |||
| nncCrSpvpcGroup | 1.3.6.1.4.1.123.3.82.3.1 | Common MIB objects for configuring a CR SPVPC source end-point across all Alcatel CID ATM platforms. | ||
| nncCrSpvpcDstCfgGroup | 1.3.6.1.4.1.123.3.82.3.2 | Common MIB objects for configuring a Cell Relay SPVPC destination end-point across all Alcatel CID ATM platforms. | ||
| nncCrSpvccGroup | 1.3.6.1.4.1.123.3.82.3.3 | Common MIB objects for configuring a CR SPVC source end-point across all Alcatel CID ATM platforms. | ||
| nncCrSpvccDstCfgGroup | 1.3.6.1.4.1.123.3.82.3.4 | Common MIB objects for configuring a Cell Relay SPVC destination end-point across all Alcatel CID ATM platforms. | ||
| nncFrSpvcGroup | 1.3.6.1.4.1.123.3.82.3.5 | Common MIB objects for configuring an SPVC using a Frame Relay source end-point across all Alcatel CID ATM platforms. | ||
| nncFrSpvcDstCfgGroup | 1.3.6.1.4.1.123.3.82.3.6 | Common MIB objects for configuring a Frame-Relay SPVC destination end-point across all Alcatel CID ATM platforms. | ||
| nncCeSpvcGroup | 1.3.6.1.4.1.123.3.82.3.7 | Common MIB objects for configuring a Circuit Emulation-based SPVC source end-point across all Alcatel CID ATM platforms. | ||
| nncCeSpvcDstCfgGroup | 1.3.6.1.4.1.123.3.82.3.8 | Common MIB objects for configuring a Circuit Emulation SPVC destination end-point across all Alcatel CID ATM platforms. | ||
| nncExtSpvcCompliances | 1.3.6.1.4.1.123.3.82.4 | |||
| nncSpvcCompliance | 1.3.6.1.4.1.123.3.82.4.1 | The compliance statement for Alcatel CID SPVC MIB implementation. |
RFC description
SNMP MIB module for managing switched virtual circuit (SVC) configuration and status on network equipment. Provides management objects for monitoring SVC-related parameters and performance metrics.
Start monitoring Alcatel/Newbridge ATM/Frame Relay switch (Soft Permanent Virtual Connections) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.