NNCEXTSPVC-MIB :: nncCeSpvcTargEpAddr

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NNCEXTSPVC-MIB › nncCeSpvcTargEpAddr

nncCeSpvcTargEpAddr

Module: NNCEXTSPVC-MIB

OID (symbolic): NNCEXTSPVC-MIB::nncCeSpvcTargEpAddr

OID (numeric): 1.3.6.1.4.1.123.3.82.1.7.1.1

Node type: OBJECT-TYPE

Type: AtmFormatDisplay

Access: read-create

Description: This object is used to specify the AESA address of the 
         target endpoint. The mapping scheme is as follows:

Byte\Bit           8      7      6      5      4      3      2      1
------------------------------------------------------------------------
1-13 byte       |        13-byte Internal Subscriber Prefix             |
------------------------------------------------------------------------
14th byte       | I/G | U/L | OUI(most significant 6 bits)              |
------------------------------------------------------------------------
15th byte       |           OUI(2nd most significant 8 bits             |
------------------------------------------------------------------------
16th byte       |           OUI(3rd most significant 8 bits             |
------------------------------------------------------------------------
17th byte       |           Shelf/Slot(1st most significant 8 bits      |
------------------------------------------------------------------------
18th byte       |           Shelf/Slot(2nd most significant 8 bits      |
------------------------------------------------------------------------
19th byte       |Flag0|            Port                                 |
------------------------------------------------------------------------
20th byte       |           Not used, default 0                         |
------------------------------------------------------------------------

What is nncCeSpvcTargEpAddr?

Holds the 20-byte AESA address of the target endpoint for this Circuit Emulation SPVC, using the same internal-prefix + OUI + shelf/slot/port encoding as the other SPVC tables (with the 20th byte unused, defaulting to 0). An operator sets this when creating the source-endpoint row so the network can signal the connection to the correct remote CE port.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.123newbridgeNNCGNI0001-SMI
1.3.6.1.4.1.123.3nncExtensionsNNCGNI0001-SMI
Numeric OIDNameModule
1.3.6.1.4.1.123.3.82nncExtSpvcNNCEXTSPVC-MIB
1.3.6.1.4.1.123.3.82.1nncExtSpvcObjectsNNCEXTSPVC-MIB
1.3.6.1.4.1.123.3.82.1.7nncCeSpvcTableNNCEXTSPVC-MIB
1.3.6.1.4.1.123.3.82.1.7.1nncCeSpvcTableEntryNNCEXTSPVC-MIB
1.3.6.1.4.1.123.3.82.1.7.1.1nncCeSpvcTargEpAddrNNCEXTSPVC-MIB