NNCEXTSPVC-MIB :: nncCrSpvccTargEpAddr

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › NNCEXTSPVC-MIB › nncCrSpvccTargEpAddr

nncCrSpvccTargEpAddr

Module: NNCEXTSPVC-MIB

OID (symbolic): NNCEXTSPVC-MIB::nncCrSpvccTargEpAddr

OID (numeric): 1.3.6.1.4.1.123.3.82.1.3.1.2

Node type: OBJECT-TYPE

Type: AtmFormatDisplay

Access: read-create

Description: This object is used to specify the AESA address for
         the target endpoint. The mapping scheme is as follows:

Byte\Bit           8      7      6      5      4      3      2      1
------------------------------------------------------------------------
1-13 byte       |        13-byte Internal Subscriber Prefix             |
------------------------------------------------------------------------
14th byte       | I/G | U/L | OUI(most significant 6 bits)              |
------------------------------------------------------------------------
15th byte       |           OUI(2nd most significant 8 bits             |
------------------------------------------------------------------------
16th byte       |           OUI(3rd most significant 8 bits             |
------------------------------------------------------------------------
17th byte       |           Shelf/Slot(1st most significant 8 bits      |
------------------------------------------------------------------------
18th byte       |           Shelf/Slot(2nd most significant 8 bits      |
------------------------------------------------------------------------
19th byte       |Flag0|            Port                                 |
------------------------------------------------------------------------
20th byte       |                    0                                  |
------------------------------------------------------------------------

What is nncCrSpvccTargEpAddr?

Holds the 20-byte AESA address of the target endpoint for this Cell Relay SPVCC, using the same internal-prefix + OUI + shelf/slot/port encoding as the SPVPC table. An operator sets it when creating the source-endpoint row so the network can signal the connection to the correct remote switch port.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.123newbridgeNNCGNI0001-SMI
1.3.6.1.4.1.123.3nncExtensionsNNCGNI0001-SMI
Numeric OIDNameModule
1.3.6.1.4.1.123.3.82nncExtSpvcNNCEXTSPVC-MIB
1.3.6.1.4.1.123.3.82.1nncExtSpvcObjectsNNCEXTSPVC-MIB
1.3.6.1.4.1.123.3.82.1.3nncCrSpvccTableNNCEXTSPVC-MIB
1.3.6.1.4.1.123.3.82.1.3.1nncCrSpvccTableEntryNNCEXTSPVC-MIB
1.3.6.1.4.1.123.3.82.1.3.1.2nncCrSpvccTargEpAddrNNCEXTSPVC-MIB