Module: NNCEXTSPVC-MIB

OID (symbolic): NNCEXTSPVC-MIB::nncFrSpvcLocRerouteConfig

OID (numeric): 1.3.6.1.4.1.123.3.82.1.5.1.12

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-create

Description: This object is used to configure the 'reroute on loss of continuity' feature using OAM-CC cells. It can be configured for either the UNI side or the NNI side, or disabled.

What is nncFrSpvcLocRerouteConfig?

Configures OAM-CC-based automatic reroute on loss of continuity for this FR SPVC: disabled(1, the default), enabledUniSide(2), or enabledNniSide(3). An admin enables this so the switch reroutes automatically on a silent continuity failure rather than waiting for a hard link-down alarm.