| OID symbolic | OID numeric | Type | Access | Description |
| accDn | 1.3.6.1.4.1.5.1.1.19 | | | |
| INT accDnAdjCircuit | 1.3.6.1.4.1.5.1.1.19.26.1.3 | INTEGER | read-only | The DECNET Circuit Number. |
| accDnAdjEntry | 1.3.6.1.4.1.5.1.1.19.26.1 | | not-accessible | One of the systems adjacent to this router. |
| INT accDnAdjNode | 1.3.6.1.4.1.5.1.1.19.26.1.1 | INTEGER | read-only | The Host Identifier of the adjacent node. |
| INT accDnAdjState | 1.3.6.1.4.1.5.1.1.19.26.1.4 | INTEGER | read-only | The state of the adjacency. |
| accDnAdjTable | 1.3.6.1.4.1.5.1.1.19.26 | | not-accessible | The set of systems adjacent to this router. |
| INT accDnAdjType | 1.3.6.1.4.1.5.1.1.19.26.1.2 | INTEGER | read-only | The type of DECNET adjacency being sustained. |
| INT accDnAreaArea | 1.3.6.1.4.1.5.1.1.19.23.1.1 | INTEGER | read-only | Remote area |
| INT accDnAreaCkt | 1.3.6.1.4.1.5.1.1.19.23.1.4 | INTEGER | read-only | Circuit over which remote area can be reached. |
| INT accDnAreaCost | 1.3.6.1.4.1.5.1.1.19.23.1.3 | INTEGER | read-only | Cost to Remote area |
| accDnAreaEntry | 1.3.6.1.4.1.5.1.1.19.23.1 | | not-accessible | Details on specific area |
| INT accDnAreaHops | 1.3.6.1.4.1.5.1.1.19.23.1.2 | INTEGER | read-only | Hops to Remote area |
| INT accDnAreaNextHop | 1.3.6.1.4.1.5.1.1.19.23.1.5 | INTEGER | read-only | Next hop to remote area. |
| accDnAreaTable | 1.3.6.1.4.1.5.1.1.19.23 | | not-accessible | DECnet area table. |
| CTR accDnBadNodes | 1.3.6.1.4.1.5.1.1.19.18 | Counter | read-only | Packets dropped due to illegal node number |
| TIK accDnBCT1 | 1.3.6.1.4.1.5.1.1.19.12 | TimeTicks | read-write | Interval between retranmissions of routing
database updates on Broadcast Address |
| INT accDnCktCost | 1.3.6.1.4.1.5.1.1.19.21.1.4 | INTEGER | read-write | Administrative circuit cost
Object will be set to a circuit-type
dependent value if not present
in entry-adding SET PDU. |
| CTR accDnCktDowns | 1.3.6.1.4.1.5.1.1.19.21.1.14 | Counter | read-only | Number of circuit down events noted on
this circuit. |
| accDnCktEntry | 1.3.6.1.4.1.5.1.1.19.21.1 | | not-accessible | The instance of an entry is the circuit number.
Existing entries can be modified. |
| INT accDnCktIndex | 1.3.6.1.4.1.5.1.1.19.21.1.1 | INTEGER | read-write | Circuit number |
| INT accDnCktPort | 1.3.6.1.4.1.5.1.1.19.21.1.16 | INTEGER | read-write | Physical port that this circuit is on
Object required in entry-adding SET PDU. |
| INT accDnCktState | 1.3.6.1.4.1.5.1.1.19.21.1.3 | INTEGER | read-only | Operational DECNET state of this circuit |
| INT accDnCktStatus | 1.3.6.1.4.1.5.1.1.19.21.1.2 | INTEGER | read-write | Administrative DECNET state of this circuit |
| accDnCktTable | 1.3.6.1.4.1.5.1.1.19.21 | | not-accessible | DECnet circuit table
Entries are added/deleted via management action. |
| INT accDnCktType | 1.3.6.1.4.1.5.1.1.19.21.1.15 | INTEGER | read-write | Circuit type
Object required in entry-adding SET PDU. |
| OCT accDnDesRtrId | 1.3.6.1.4.1.5.1.1.19.21.1.8 | OCTET STRING | read-only | ID of router which is designated router on
this circuit. Lower 10 bits is node number,
six bits above that are area number. |
| INT accDnDesRtrPrio | 1.3.6.1.4.1.5.1.1.19.21.1.9 | INTEGER | read-only | Priority of router which is designated router on
this circuit. |
| CTR accDnEndNodePktRecs | 1.3.6.1.4.1.5.1.1.19.21.1.12 | Counter | read-only | Number of end-node packets received on
this circuit. |
| CTR accDnEndNodePktSnds | 1.3.6.1.4.1.5.1.1.19.21.1.13 | Counter | read-only | Number of end-node packets sent on
this circuit. |
| INT accDnEntryStatus | 1.3.6.1.4.1.5.1.1.19.21.1.22 | INTEGER | read-write | Setting this object to invalid deletes entry |
| CTR accDnFmtErrs | 1.3.6.1.4.1.5.1.1.19.20 | Counter | read-only | Packets dropped due to packet format error |
| INT accDnForwardFilterDest | 1.3.6.1.4.1.5.1.1.19.25.1.1 | INTEGER | read-write | If 0, all DECNET Addresses.
If an Area with Host Part 0, all traffic to
that Area.
If a DECNET Host ID, all traffic to that Host. |
| INT accDnForwardFilterDisposition | 1.3.6.1.4.1.5.1.1.19.25.1.3 | INTEGER | read-write | This variable indicates what is to be done
with traffic from accDnForwardFilterSource to
accDnForwardFilterDest. When overlaps occur
('discard all traffic from Area 4.0 to Anywhere
except traffic from Host 4.123'), the most
specific match applies. |
| accDnForwardFilterEntry | 1.3.6.1.4.1.5.1.1.19.25.1 | | not-accessible | A single set of messages that the Network Manager
wants selectively treated. |
| INT accDnForwardFilterEntStat | 1.3.6.1.4.1.5.1.1.19.25.1.4 | INTEGER | read-write | setting accDnForwardFilterEntStat to invalid
has the effect of removing the filter on the
next system reset. |
| INT accDnForwardFilterSource | 1.3.6.1.4.1.5.1.1.19.25.1.2 | INTEGER | read-write | If 0, all DECNET Traffic.
If an Area with Host Part 0, all traffic from
that Area.
If a DECNET Host ID, all traffic from that
Host. |
| accDnForwardFilterTable | 1.3.6.1.4.1.5.1.1.19.25 | | not-accessible | The DECNET traffic that the Network Manager wants
selectively treated. |
| TIK accDnHelloInt | 1.3.6.1.4.1.5.1.1.19.21.1.6 | TimeTicks | read-write | Interval between transmission of Router Hello
messages to other DECNET routers on this circuit |
| INT accDnID | 1.3.6.1.4.1.5.1.1.19.2 | INTEGER | read-write | Node ID; Least 10 bits identify the node,
six bits above that identify the area. |
| INT accDnMaxAdjRtr | 1.3.6.1.4.1.5.1.1.19.5 | INTEGER | read-write | Maximum number of adjacent routers |
| INT accDnMaxArea | 1.3.6.1.4.1.5.1.1.19.4 | INTEGER | read-write | Maximum area number permitted |
| INT accDnMaxEndNode | 1.3.6.1.4.1.5.1.1.19.6 | INTEGER | read-write | Maximum number of broadcast endnode adjacencies |
| INT accDnMaxForCost | 1.3.6.1.4.1.5.1.1.19.11 | INTEGER | read-write | Maximum cost allowed on a path to another area |
| INT accDnMaxForHop | 1.3.6.1.4.1.5.1.1.19.10 | INTEGER | read-write | Maximum number of hops allowed to another area |
| INT accDnMaxLocCost | 1.3.6.1.4.1.5.1.1.19.8 | INTEGER | read-write | Maximum cost allowed on a path within this area |
| INT accDnMaxLocHop | 1.3.6.1.4.1.5.1.1.19.7 | INTEGER | read-write | Maximum number of hops allowed within this area |
| INT accDnMaxNode | 1.3.6.1.4.1.5.1.1.19.3 | INTEGER | read-write | Maximum node number permitted in the local area |
| INT accDnMaxRtr | 1.3.6.1.4.1.5.1.1.19.21.1.5 | INTEGER | read-write | Maximum number of routers that can be
communicated with over this circuit |
| INT accDnMaxVisit | 1.3.6.1.4.1.5.1.1.19.9 | INTEGER | read-write | Maximum number of node visits allowed for a packet |
| INT accDnMsgLev | 1.3.6.1.4.1.5.1.1.19.14 | INTEGER | read-write | Message level for generation of trap messages
describing DECNET operational phenonomena
See Trap level for description |
| INT accDnNodeState | 1.3.6.1.4.1.5.1.1.19.15 | INTEGER | read-write | Operational state of the node |
| INT accDnNumber | 1.3.6.1.4.1.5.1.1.19.1 | INTEGER | read-only | Number of DECNET circuits |
| CTR accDnPktOsizes | 1.3.6.1.4.1.5.1.1.19.19 | Counter | read-only | Packets dropped due to oversize packet |
| INT accDnRouteFilterAdj | 1.3.6.1.4.1.5.1.1.19.24.1.1 | INTEGER | read-write | If 0, all adjacent systems.
If a DECNET Area with host id 0, all adjacent
systems in that area.
If a DECNET Host ID, that adjacent system. |
| INT accDnRouteFilterDisposition | 1.3.6.1.4.1.5.1.1.19.24.1.3 | INTEGER | read-write | This variable indicates what to do with the
indicated routing information. Where overlaps
occur ('accept no routing information from area
3.0 except from router 3.27'), the most specif-
ic match applies. |
| accDnRouteFilterEntry | 1.3.6.1.4.1.5.1.1.19.24.1 | | not-accessible | A single controlled DECNET Route. |
| INT accDnRouteFilterEntStat | 1.3.6.1.4.1.5.1.1.19.24.1.4 | INTEGER | read-write | setting this variable to 'invalid' has the ef-
fect of invalidating it as of the next system
reset. |
| INT accDnRouteFilterNode | 1.3.6.1.4.1.5.1.1.19.24.1.2 | INTEGER | read-write | If 0, all routing information.
If a DECNET Area with Host ID 0, relevant level
2 routing information.
If a DECNET Host ID, level 1 routing informa-
tion for that host. |
| accDnRouteFilterTable | 1.3.6.1.4.1.5.1.1.19.24 | | not-accessible | The DECNET IV Routes that the Network Manager wants to
be careful about. |
| INT accDnRtCkt | 1.3.6.1.4.1.5.1.1.19.22.1.4 | INTEGER | read-only | Circuit number to use to get to destination |
| INT accDnRtCost | 1.3.6.1.4.1.5.1.1.19.22.1.3 | INTEGER | read-only | Cost to destination |
| accDnRtEntry | 1.3.6.1.4.1.5.1.1.19.22.1 | | not-accessible | Detail on specific route |
| INT accDnRtHops | 1.3.6.1.4.1.5.1.1.19.22.1.2 | INTEGER | read-only | Number of hops to destination |
| INT accDnRtNextHop | 1.3.6.1.4.1.5.1.1.19.22.1.5 | INTEGER | read-only | Next router along the way to destination |
| INT accDnRtNode | 1.3.6.1.4.1.5.1.1.19.22.1.1 | INTEGER | read-only | Destination node |
| INT accDnRtrPriority | 1.3.6.1.4.1.5.1.1.19.21.1.7 | INTEGER | read-write | Priority of this Decnet router to become
designated router on this circuit. |
| accDnRtTable | 1.3.6.1.4.1.5.1.1.19.22 | | not-accessible | DECnet routing table |
| TIK accDnT1 | 1.3.6.1.4.1.5.1.1.19.13 | TimeTicks | read-write | Interval between retranmissions of routing
database updates non-broadcast |
| CTR accDnTrnPktRecs | 1.3.6.1.4.1.5.1.1.19.21.1.10 | Counter | read-only | Number of transit packets received on
this circuit. |
| CTR accDnTrnPktSnds | 1.3.6.1.4.1.5.1.1.19.21.1.11 | Counter | read-only | Number of transit packets sent on
this circuit. |
| CTR accDnUnreachs | 1.3.6.1.4.1.5.1.1.19.16 | Counter | read-only | Packets dropped due to node unreachable |
| CTR accDnVisitXcds | 1.3.6.1.4.1.5.1.1.19.17 | Counter | read-only | Packets dropped due to visits exceeded |
| INT accDnX25FacIndex | 1.3.6.1.4.1.5.1.1.19.21.1.23 | INTEGER | read-write | Index of optional facility string or 0. |
| TIK accDnX25Idle | 1.3.6.1.4.1.5.1.1.19.21.1.19 | TimeTicks | read-write | Maximum idle time before this circuit is
considered unused.
Object will be set to default value if not present
in entry-adding SET PDU. |
| STR accDnX25InAddr | 1.3.6.1.4.1.5.1.1.19.21.1.18 | DisplayString | read-write | Packets from this address are accepted
on this circuit.
Object will be set to default value if not present
in entry-adding SET PDU. |
| STR accDnX25InOutAddr | 1.3.6.1.4.1.5.1.1.19.21.1.17 | DisplayString | read-write | X25 address for other end of circuit; we'll
send to this address and will accept packets from
this address for this circuit.
Object required in entry-adding SET PDU if
circuit type is X.25 |
| INT accDnX25PktVal | 1.3.6.1.4.1.5.1.1.19.21.1.20 | INTEGER | read-write | Maximum X25 packet size
Object will be set to default value if not present
in entry-adding SET PDU. |
| INT accDnX25PktWin | 1.3.6.1.4.1.5.1.1.19.21.1.21 | INTEGER | read-write | X25 packet window
Object will be set to default value if not present
in entry-adding SET PDU. |