All MIBs › VMWARE-NSX-MANAGER-MIB
Organization: VMware, Inc
Last Updated: 2016-06-02
Category: VMware Virtualization
Description: Monitors VMware NSX network virtualization manager, controller cluster, and transport node status.
Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is VMWARE-NSX-MANAGER-MIB?
VMWARE-NSX-MANAGER-MIB is a VMware vendor MIB that defines SNMP trap notifications sent by NSX Manager, the central management component of VMware's NSX network virtualization platform for software-defined data centers (SDDC). It exposes event-oriented objects — event code, timestamp, message text, severity, and originating component — used by NSX Manager to report state changes affecting virtual networks, controllers, and transport nodes. Its monitoring focus is fault/event status of the software-defined networking control plane, letting operators detect NSX Manager, controller-cluster, or transport-node faults, configuration failures, or severity-escalating events as they happen rather than by polling counters. It depends conceptually on the broader VMware NSX/vSphere SDDC architecture (vCenter integration) though it is a self-contained trap MIB. It is typically deployed on VMware NSX Manager appliances within vSphere-based software-defined data centers. Engineers can download the VMWARE-NSX-MANAGER-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in VMWARE-NSX-MANAGER-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- VMware NSX Manager appliances (SDDC/vSphere environments)
Monitoring Examples
An NMS receiving a trap would inspect vmwNsxMEventCode, vmwNsxMEventSeverity, and vmwNsxMEventMessage to identify what happened, cross-referencing vmwNsxMEventComponent to isolate whether the issue originated in NSX Manager, a controller, or a transport node, with vmwNsxMEventTimestamp used for event correlation. A trap with high vmwNsxMEventSeverity and vmwNsxMEventComponent pointing to a transport node would indicate a data-plane connectivity problem needing investigation.
What Can Be Monitored
- NSX event code and severity
- event message and timestamp
- originating NSX component (manager/controller/transport node)
- event count
This MIB depends on
Related MIBs
Imported Objects
From SNMPv2-CONF
| MODULE-COMPLIANCE | |
| NOTIFICATION-GROUP | |
| OBJECT-GROUP |
From SNMPv2-SMI
| Integer32 | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE |
From SNMPv2-TC
| DateAndTime | |
| TEXTUAL-CONVENTION |
From UUID-TC-MIB
| UUID |
From VMWARE-ROOT-MIB
| vmwNsxManager | OBJECT-IDENTITY |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| vmwNsxManagerMIB | 1.3.6.1.4.1.6876.90.1 | This MIB file contains the information that the receiving party needs in order to interpret SNMP traps sent by NSX Manager. VMware NSX for vSphere is a key product in the SDDC architecture. With NSX, virtualization delivers for networking what it has already delivered for compute and storage. In much the same way that server virtualization programmatically creates, snapshots, deletes and restores software-based virtual machines (VMs), NSX network virtualization programmatically creates, snapshots, deletes, and restores software-based virtual networks. The result is a completely transformative approach to networking that not only enables data center managers to achieve orders of magnitude better agility and economics, but also allows for a vastly simplified operational model for the underlying physical network. With the ability to be deployed on any IP network, including both existing traditional networking models and next-generation fabric architectures from any vendor, NSX is a completely non-disruptive solution. In fact, with NSX, the physical network infrastructure you already have is all you need to deploy a software-defined data center. The NSX Manager provides the graphical user interface (GUI) and the REST APIs for creating, configuring, and monitoring NSX components, such as controllers, logical switches, and edge services gateways. The NSX Manager provides an aggregated system view and is the centralized network management component of NSX. NSX Manager is installed as a virtual appliance on any ESX host in your vCenter environment. Support requests can be filed with VMware using KB article: http://kb.vmware.com/kb/2006985 To reach NSX Manager Service Composer UI, login to vSphere UI(https://)->Networking & Security->Service Composer | ||
| vmwNsxMAlertData | 1.3.6.1.4.1.6876.90.1.1 | This members of this group are the OIDs for VarBinds that contain data for ALL Alerts. | ||
| I32 vmwNsxMEventCode | 1.3.6.1.4.1.6876.90.1.1.1 | Integer32 | accessible-for-notify | The event code of the alert that was generated. To fetch a list of all the events with their code, severity and description please invoke the nsx-manager url https:///api/2.0/systemevent/eventcode . The event code specifically identifies each individual event type. This event code is uniquely assigned only once to a particular event type. |
| DAT vmwNsxMEventTimestamp | 1.3.6.1.4.1.6876.90.1.1.2 | DateAndTime | accessible-for-notify | The timestamp when the event was raised in the NSX Manager. |
| OCT vmwNsxMEventMessage | 1.3.6.1.4.1.6876.90.1.1.3 | OCTET STRING | accessible-for-notify | This object provides a human readable description of the event or group of events |
| VMW vmwNsxMEventSeverity | 1.3.6.1.4.1.6876.90.1.1.4 | VmwNsxManagerTypeSeverity | accessible-for-notify | The severity for the event that was generated. The severity is pre-defined and can only be changed from the NSX Manager section of vsphere web client if the administrator so wishes. |
| OCT vmwNsxMEventComponent | 1.3.6.1.4.1.6876.90.1.1.5 | OCTET STRING | accessible-for-notify | The NSX manager component where this event was generated. |
| UUI vmwNsxMUuid | 1.3.6.1.4.1.6876.90.1.1.6 | UUID | accessible-for-notify | The NSX manager UUID where this event was generated. |
| I32 vmwNsxMCount | 1.3.6.1.4.1.6876.90.1.1.7 | Integer32 | accessible-for-notify | The count of the number of events for a particular group raised in the last 5 minute interval. |
| vmwNsxMNotification | 1.3.6.1.4.1.6876.90.1.2 | All notifications for NSX Manager use this oid prefix. | ||
| vmwNsxMBranch | 1.3.6.1.4.1.6876.90.1.2.0 | Branch segregated out for various groups and other future requirements. | ||
| vmwNsxMGroupsBranch | 1.3.6.1.4.1.6876.90.1.2.0.1 | Grouped Notifications will have this OID prefix. | ||
| vmwNsxMGroupsPrefix | 1.3.6.1.4.1.6876.90.1.2.0.1.0 | Prefix added to place zero in penultimate sub-identifier of group oids. | ||
| NTF vmwNsxMConfigGroup | 1.3.6.1.4.1.6876.90.1.2.0.1.0.1 | Configuration notifications that are grouped will have this OID prefix. | ||
| vmwNsxMSnmp | 1.3.6.1.4.1.6876.90.1.2.1 | Notifications that are Snmp related will have this OID prefix. | ||
| vmwNsxMSnmpPrefix | 1.3.6.1.4.1.6876.90.1.2.1.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for Snmp module. | ||
| NTF vmwNsxMSnmpDisabled | 1.3.6.1.4.1.6876.90.1.2.1.0.1 | This notification is sent when the sending out of Snmp traps is disabled. This would most likely be the last Snmp trap the snmp manager receives. You may some times not receive it in case of high volume of traps. In those cases you can rely on the heartbeat traps not being sent out. Action required: None. If the sending of Snmp traps is enabled a warmStart trap is received. Frequency of traps: Once, whenever the sending snmp traps is disabled. | ||
| NTF vmwNsxMSnmpManagerConfigUpdated | 1.3.6.1.4.1.6876.90.1.2.1.0.2 | This notification is sent when the snmp manager configuration has been updated. The event message will carry the semicolon separated new snmp managers' details. Action required: None Frequency of traps: Once, whenever the Snmp manager configuration is updated. | ||
| vmwNsxMSecurity | 1.3.6.1.4.1.6876.90.1.2.2 | Notifications that are security related will have this OID prefix. | ||
| vmwNsxMSecurityPrefix | 1.3.6.1.4.1.6876.90.1.2.2.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for security module. | ||
| NTF vmwNsxMIpAddedBlackList | 1.3.6.1.4.1.6876.90.1.2.2.0.1 | Whenever user authentication fails for number of times that user is blacklisted and further login attempts are disabled for that user from given IP address for some time. Action required: None Frequency of traps: Whenever user authentication fails consecutively within some time. | ||
| NTF vmwNsxMIpRemovedBlackList | 1.3.6.1.4.1.6876.90.1.2.2.0.2 | After user is blacklisted, after blacklist duration expires, user is removed from blacklist. Action required: None Frequency of traps: Whenever blacklist duration expires for any user. | ||
| NTF vmwNsxMSsoConfigFailure | 1.3.6.1.4.1.6876.90.1.2.2.0.3 | Whenever configuration of lookup service / SSO fails due to various reasons like invalid credentials, invalid configuration, time sync problem etc. Action required: Check the event message and reconfigure lookup service with correct details. Frequency of traps: Once per failed configuration of lookup service. | ||
| NTF vmwNsxMSsoUnconfigured | 1.3.6.1.4.1.6876.90.1.2.2.0.4 | Whenever user unconfigures lookup service. Action required: None Frequency of traps: Once per unconfiguration event of lookup service. | ||
| NTF vmwNsxMUserRoleAssigned | 1.3.6.1.4.1.6876.90.1.2.2.0.5 | When role is assigned on NSX manager for vCenter user. Action required: None Frequency of traps: Once for each user who is assigned role. | ||
| NTF vmwNsxMUserRoleUnassigned | 1.3.6.1.4.1.6876.90.1.2.2.0.6 | When role is unassigned on NSX manager for vCenter user. Action: None Frequency of traps: Once for each user where role is removed. | ||
| NTF vmwNsxMGroupRoleAssigned | 1.3.6.1.4.1.6876.90.1.2.2.0.7 | When role is assigned on NSX manager for vCenter group. Action required: None Frequency of traps: Once for each group who is assigned role. | ||
| NTF vmwNsxMGroupRoleUnassigned | 1.3.6.1.4.1.6876.90.1.2.2.0.8 | When role is unassigned on NSX manager for vCenter group. Action required: None Frequency of traps: Once for each group where role is removed. | ||
| NTF vmwNsxMVcLoginFailed | 1.3.6.1.4.1.6876.90.1.2.2.0.9 | Whenever Connection with vCenter starts failing due to invalid credentials. Action required: Reconfigure NSX Manager vCenter configuration with correct credentials. | ||
| NTF vmwNsxMVcDisconnected | 1.3.6.1.4.1.6876.90.1.2.2.0.10 | Whenever there is disconnectivity for default VCenter Connection maintained by NSX. Action required: Administrator needs to check the connectivity with vCenter for network problems or any other reasons. | ||
| NTF vmwNsxMLostVcConnectivity | 1.3.6.1.4.1.6876.90.1.2.2.0.11 | Whenever there is disconnectivity for default VCenter Connection maintained by NSX. Action required: Administrator needs to check the connectivity with vCenter for network problems or any other reasons. | ||
| NTF vmwNsxMSsoDisconnected | 1.3.6.1.4.1.6876.90.1.2.2.0.12 | Whenever there is disconnection with SSO lookup service. Action required: Please check the configuration for possible disconnection reasons like Invalid Credentials, Time sync issues, Network connectivity problems etc. Navigate to Appliance management Web UI in browser (https:///) traverse to Manage vCenter Registration tab and verify the configuration for SSO Lookupservice. Frequency of traps: Once per disconnect event, default frequency to check SSO connection state is 1 hour. | ||
| vmwNsxMFirewall | 1.3.6.1.4.1.6876.90.1.2.3 | Notifications that are firewall related will have this OID prefix. | ||
| vmwNsxMFirewallPrefix | 1.3.6.1.4.1.6876.90.1.2.3.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for firewall module. | ||
| NTF vmwNsxMFltrCnfgUpdateFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.1 | NSX Manager failed to enforce DFW. VMs on this host may not be protected by the DFW. Contextual data provided with this event may indicate the cause of this failure. This could happen if the VIB version mismatches on the NSX Manager and ESX host. This may happen during an upgrade. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMFltrCnfgNotAppliedToVnic | 1.3.6.1.4.1.6876.90.1.2.3.0.2 | NSX Manager failed to enforce DFW configuration on a vnic. This particular VM may not be protected by the DFW. Contextual data provided with this event may indicate the cause of this failure.This could happen if the VIB version mismatches on the NSX Manager and ESX host. This may happen during an upgrade. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMFltrCnfgAppliedToVnic | 1.3.6.1.4.1.6876.90.1.2.3.0.3 | Successfully updated filter config. Action required: None | ||
| NTF vmwNsxMFltrCreatedForVnic | 1.3.6.1.4.1.6876.90.1.2.3.0.4 | Filter created. DFW is enforced in the datapath for the vnic. Action required: None | ||
| NTF vmwNsxMFltrDeletedForVnic | 1.3.6.1.4.1.6876.90.1.2.3.0.5 | Filter deleted. DFW is removed from the vnic. Action required: None | ||
| NTF vmwNsxMFirewallConfigUpdateFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.6 | Firewall rule Configuration between the NSX Manager and the host is not in sync. Contextual data provided with this event may indicate the cause of this failure. Verify that the host in question was properly prepared by NSX Manager. Collect error logs (vsfwd.log) when the host received firewall config. Force sync firewall config using ForceSync API/UI. See kb.vmware.com/kb/2125437 . If the issue persists, please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMFirewallRuleFailedVnic | 1.3.6.1.4.1.6876.90.1.2.3.0.7 | Failed to apply Distributed Firewall configuration. Contextual data provided with this event may indicate the cause of this failure. Collect error logs (vmkernel.log) when the firewall configuration was applied to the vnic. vsip kernel heaps may not have enough free memory. Check VSFWD logs . See kb.vmware.com/kb/2125437. If the issue persists, please collect the ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMFirewallRuleAppliedVnic | 1.3.6.1.4.1.6876.90.1.2.3.0.8 | Applied firewall config. Key value will have context info like generation number and also other debugging info. Action required: None | ||
| NTF vmwNsxMCntnrCnfgUpdateFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.9 | Failed receive, parse or update the container configuration. Contextual data provided with this event may indicate the cause of this failure. Collect error logs (vmkernel.log) when firewall configuration was applied to the vnic. Verify that vsip kernel heaps have enough free memory. Check VSFWD logs. See kb.vmware.com/kb/2125437 . If the issue persists, please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMFlowMissed | 1.3.6.1.4.1.6876.90.1.2.3.0.10 | Flow missed. Contextual data provided with this event may indicate the cause of this failure. Collect error logs (vmkernel.log) when firewall configuration was applied to the vnic. Verify that vsip kernel heaps have enough free memory and vsfwd memory consumption is within resource limits. Check VSFWD logs. See kb.vmware.com/kb/2125437. If the issue persists, please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMSpoofGuardCnfgUpdateFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.11 | Failed to receive, parse or Update the spoofguard configuration. Contextual data provided with this event may indicate the cause of this failure. Verify that the host in question was properly prepared by NSX Manager. Collect error logs (vmkernel.log) when the spoofguard configuration was applied to the host. For Sync the firewall configuration . See kb.vmware.com/kb/2125437. | ||
| NTF vmwNsxMSpoofGuardFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.12 | Failed to apply spoofguard to the vnic. Contextual data provided with this event may indicate the cause of this failure. Verify that vsip kernel heaps have enough free memory. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMSpoofGuardApplied | 1.3.6.1.4.1.6876.90.1.2.3.0.13 | Enabled spoofguard for vnic. Action required: None | ||
| NTF vmwNsxMSpoofGuardDisableFail | 1.3.6.1.4.1.6876.90.1.2.3.0.14 | Failed to disable spoofguard on the vnic. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMSpoofGuardDisabled | 1.3.6.1.4.1.6876.90.1.2.3.0.15 | Disabled spoofguard for vnic. Action required: None | ||
| NTF vmwNsxMLegacyAppServiceDeletionFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.16 | A notification generated when legacy application service VM deletion failed. | ||
| NTF vmwNsxMFirewallCpuThresholdCrossed | 1.3.6.1.4.1.6876.90.1.2.3.0.17 | vsfwd CPU usage threshold was exceeded. Reduce the amount of traffic of VMs on the host in question. | ||
| NTF vmwNsxMFirewallMemThresholdCrossed | 1.3.6.1.4.1.6876.90.1.2.3.0.18 | vsfwd memory threshold exceeded. Reduce the number of of VMs on the host in question, reduce the number of rules or containers in firewall config. Use appliedTo feature to limit the number of rules for the current cluster. | ||
| NTF vmwNsxMConnPerSecThrshldCrossed | 1.3.6.1.4.1.6876.90.1.2.3.0.19 | vsfwd Connectons Per Second (CPS) threshold exceeded. Reduce the amount of new connections of VMs on the host in question. | ||
| NTF vmwNsxMFirewallCnfgUpdateTimedOut | 1.3.6.1.4.1.6876.90.1.2.3.0.20 | NSX Manager waits for 2 minutes after publishing the Firewall configuration to each host in the cluster. If a host takes more than 2 minutes to process the data, it times out. Please check the Host in question. See if VSFWD is functioning or not. Also use CLI commands to verify if the rule realization is working properly or not. See kb.vmware.com/kb/2125437. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMSpoofGuardCnfgUpdateTmOut | 1.3.6.1.4.1.6876.90.1.2.3.0.21 | NSX Manager waits for 2 minutes after publishing the Spoofguard configuration to each host in the cluster. If a host takes more than 2 minutes to process the data, it times out. Please check the Host in question. See if VSFWD is functioning or not. Also use CLI commands to verify if the rule realization is working properly or not. See kb.vmware.com/kb/2125437. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMFirewallPublishFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.22 | Firewall Configuration Publishing has failed for a given cluster/host. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMCntnrUpdatePublishFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.23 | Publishing of container (IP/MAC/vNIC) update pdate failed for a given host/cluster object. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMSpoofGuardUpdatePublishFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.24 | The publishing of the spoofguard updates on this host has failed. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMExcludeListPublishFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.25 | The publishing of the exclude list or updates to the exclude list on this host has failed. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMFirewallCnfgUpdateOnDltCntnr | 1.3.6.1.4.1.6876.90.1.2.3.0.26 | Deletion of the object referenced in firewall rules. Action required: Go to the NSX manager DFW UI. All the invalid reference are marked invalid on the UI as well. Please remove the orphaned referenced and update the firewall rules. | ||
| NTF vmwNsxMHostSyncFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.27 | Host-level force synchronization has failed. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMHostSynced | 1.3.6.1.4.1.6876.90.1.2.3.0.28 | Force Sync operation for host succeeded. Action required: None | ||
| NTF vmwNsxMFirewallInstalled | 1.3.6.1.4.1.6876.90.1.2.3.0.29 | The Distributed Firewall was successfully Installed on the host. | ||
| NTF vmwNsxMFirewallInstallFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.30 | The Distributed Firewall Installation has failed. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMFirewallClusterInstalled | 1.3.6.1.4.1.6876.90.1.2.3.0.31 | The Distributed Firewall has been installed at the request of a user. | ||
| NTF vmwNsxMFirewallClusterUninstalled | 1.3.6.1.4.1.6876.90.1.2.3.0.32 | The Distributed Firewall has been uninstalled at the request of a user. | ||
| NTF vmwNsxMFirewallClusterDisabled | 1.3.6.1.4.1.6876.90.1.2.3.0.33 | The Distributed Firewall has been disabeld on the cluster at the request of a user. | ||
| NTF vmwNsxMFirewallForceSyncClusterFailed | 1.3.6.1.4.1.6876.90.1.2.3.0.34 | Force Sync operation for the cluster has failed. Use CLI commands to look at the logs and verify if any error messages appeared during the operation. See kb.vmware.com/kb/2125437. Please collect ESX and NSX Manager tech support bundle and open a SR with Vmware techsupport. See http://kb.vmware.com/kb/2074678 and http://kb.vmware.com/kb/1010705 | ||
| NTF vmwNsxMFirewallForceSyncClusterSuccess | 1.3.6.1.4.1.6876.90.1.2.3.0.35 | Force Sync operation for cluster succeeded. Action required: None | ||
| NTF vmwNsxMFirewallVsfwdProcessStarted | 1.3.6.1.4.1.6876.90.1.2.3.0.36 | vsfwd process started on host. Action required: None | ||
| vmwNsxMEdge | 1.3.6.1.4.1.6876.90.1.2.4 | Notifications that are edge related will have this OID prefix. | ||
| vmwNsxMEdgePrefix | 1.3.6.1.4.1.6876.90.1.2.4.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for edge module. | ||
| NTF vmwNsxMEdgeNoVmServing | 1.3.6.1.4.1.6876.90.1.2.4.0.1 | None of the Edge VMs found in serving state. There is a possibility of network disruption. Action required: System auto recovers from this state today. Event should be followed by traps with event code 30202 or 30203 | ||
| NTF vmwNsxMEdgeGatewayCreated | 1.3.6.1.4.1.6876.90.1.2.4.0.2 | Edge Gateway created. Action required: None | ||
| NTF vmwNsxMEdgeVmBadState | 1.3.6.1.4.1.6876.90.1.2.4.0.3 | Edge VM in bad state. Needs a force sync. Action required: System auto triggres force sync but if problem is sustained then manual force sync should be triggered. For ESG force sync is disruptive and will reboot edge VMs. | ||
| NTF vmwNsxMEdgeVmCommFailed | 1.3.6.1.4.1.6876.90.1.2.4.0.4 | Failed to communicate with the Edge VM. Action required: Need investigation depending upon comunication channel. Log needs to be checked for VIX error code for futher action. | ||
| NTF vmwNsxMEdgeVmCnfgChanged | 1.3.6.1.4.1.6876.90.1.2.4.0.5 | A notification generated when NSX Edge VM configuration is changed. Action required: None | ||
| NTF vmwNsxMEdgeGatewayDeleted | 1.3.6.1.4.1.6876.90.1.2.4.0.6 | A notification generated when Edge Gateway is deleted. Action required: None | ||
| NTF vmwNsxMEdgeGatewayReDeployed | 1.3.6.1.4.1.6876.90.1.2.4.0.7 | A notification generated when Edge Gateway is redeployed. Action required: None | ||
| NTF vmwNsxMEdgeVmPowerOff | 1.3.6.1.4.1.6876.90.1.2.4.0.8 | A notification generated when NSX Edge VM is powered off. Action required: None | ||
| NTF vmwNsxMEdgeApplianceSizeChanged | 1.3.6.1.4.1.6876.90.1.2.4.0.9 | A notification generated when Edge appliance size has changed. Action required: None | ||
| NTF vmwNsxMEdgeUpgrade51x | 1.3.6.1.4.1.6876.90.1.2.4.0.10 | A notification generated when Edge Gateway is upgraded to 5.1.x. Action required: None | ||
| NTF vmwNsxMEdgeLicenseChanged | 1.3.6.1.4.1.6876.90.1.2.4.0.11 | A notification generated when Edge licensing changed on vCenter Server. Action required: None | ||
| NTF vmwNsxMEdgeApplianceMoved | 1.3.6.1.4.1.6876.90.1.2.4.0.12 | A notification generated when Edge appliance is moved in the vCenter inventory. | ||
| NTF vmwNsxMEdgeApplianceNotFound | 1.3.6.1.4.1.6876.90.1.2.4.0.13 | A notification generated when Edge appliance not found in the vCenter inventory. Action required: If VM is accidentally deleted, redeploy edge. | ||
| NTF vmwNsxMEdgeVMHealthCheckMiss | 1.3.6.1.4.1.6876.90.1.2.4.0.14 | A notification generated when Edge VM is not responding to health check. Action required: Communicaiton issues between manager and edge. Log analysis required to root cause issue. | ||
| NTF vmwNsxMEdgeHealthCheckMiss | 1.3.6.1.4.1.6876.90.1.2.4.0.15 | A notification generated when none of the Edge VMs are found in serving state. There is a possibility of network disruption. Action required: Commnunicaiton issues between manager and edge. Log analysis required to root cause issue. | ||
| NTF vmwNsxMEdgeCommAgentNotConnected | 1.3.6.1.4.1.6876.90.1.2.4.0.16 | A notification generated when Edge Communication Agent is not connected to vCenter Server. Action required: Check VSM and VC connectivity. Try registering VSM to VC | ||
| NTF vmwNsxMApplianceWithDifferentId | 1.3.6.1.4.1.6876.90.1.2.4.0.17 | A notification generated when Edge VM is discovered with a different vmId. Action required: None | ||
| NTF vmwNsxMFirewallRuleModified | 1.3.6.1.4.1.6876.90.1.2.4.0.18 | A notification generated when Edge firewall rule is modified. Action required: Revisit firewall rule and perform required updates | ||
| NTF vmwNsxMEdgeAntiAffinityRuleViolated | 1.3.6.1.4.1.6876.90.1.2.4.0.19 | A notification generated when powering on NSX Edge appliance violates a virtual machine anti-affinity rule. Action required: Anti affinity rules removed from cluster. Both HA VM may run on same host. Go to VC and please revisit anti affinity rules on Cluster | ||
| NTF vmwNsxMEdgeHaEnabled | 1.3.6.1.4.1.6876.90.1.2.4.0.20 | A notification generated when NSX Edge HighAvailability is enabled. Action required: None | ||
| NTF vmwNsxMEdgeHaDisabled | 1.3.6.1.4.1.6876.90.1.2.4.0.21 | A notification generated when NSX Edge HighAvailability is disabled. Action required: None | ||
| NTF vmwNsxMEdgeGatewayRecovered | 1.3.6.1.4.1.6876.90.1.2.4.0.22 | A notification generated when NSX Edge Gateway has recovered and now responding to health check. Action required: None | ||
| NTF vmwNsxMEdgeVmRecovered | 1.3.6.1.4.1.6876.90.1.2.4.0.23 | A notification generated when NSX Edge VM has recovered and now responding to health check. Actione required: None | ||
| NTF vmwNsxMEdgeGatewayUpgraded | 1.3.6.1.4.1.6876.90.1.2.4.0.24 | A notification generated when Edge Gateway is upgraded. Action required: None | ||
| NTF vmwNsxMEdgeVmHlthChkDisabled | 1.3.6.1.4.1.6876.90.1.2.4.0.25 | A notification generated when Edge VM health check is disabled on consecutive critical vix errors. Please redeploy or force sync vm to resume health check. Action required: This points to environmental issues that lead to repeated failure over vix. Log analysis needs to be done to identify root cause. Post resoving issues force sync edge vm to resume health check. Force sync and redeploy are disruptive operation. | ||
| NTF vmwNsxMEdgePrePublishFailed | 1.3.6.1.4.1.6876.90.1.2.4.0.26 | A notification generated when Pre Publish has failed on Edge VM. Action required: Firewall rules might be out of sync. System auto recovers but if problem persists then trigger force sync. | ||
| NTF vmwNsxMEdgeForcedSync | 1.3.6.1.4.1.6876.90.1.2.4.0.27 | A notification generated when Edge VM was force synced. Action required: None | ||
| NTF vmwNsxMEdgeVmBooted | 1.3.6.1.4.1.6876.90.1.2.4.0.28 | A notification generated when Edge VM was booted. Action required: None | ||
| NTF vmwNsxMEdgeVmInBadState | 1.3.6.1.4.1.6876.90.1.2.4.0.29 | A notification generated when Edge VM is in Bad State. Needs a force sync. Action required: Force sync required. | ||
| NTF vmwNsxMEdgeVmCpuUsageIncreased | 1.3.6.1.4.1.6876.90.1.2.4.0.30 | A notification generated when Edge VM CPU usage has increased. Action required: Spikes are normal but collect tech support logs for further analysis if high CPU sustained for longer duration. | ||
| NTF vmwNsxMEdgeVmMemUsageIncreased | 1.3.6.1.4.1.6876.90.1.2.4.0.31 | A notification generated when Edge VM Memory usage has increased. Action required: System recovers but collect tech support logs for further analysis. | ||
| NTF vmwNsxMEdgeVmProcessFailure | 1.3.6.1.4.1.6876.90.1.2.4.0.32 | A notification generated when Edge VM process monitor detects a process failure. Action required: System recovers but collect tech support logs for further analysis. | ||
| NTF vmwNsxMEdgeVmSysTimeBad | 1.3.6.1.4.1.6876.90.1.2.4.0.33 | A notification generated when Edge VM system time is bad. Action required: System recovers. Check NTP setting on hosts. | ||
| NTF vmwNsxMEdgeVmSysTimeSync | 1.3.6.1.4.1.6876.90.1.2.4.0.34 | A notification generated when Edge VM system time sync up happens. Action required: None | ||
| NTF vmwNsxMEdgeAesniCryptoEngineUp | 1.3.6.1.4.1.6876.90.1.2.4.0.35 | A notification generated when AESNI crypto engine is up. Action required: None | ||
| NTF vmwNsxMEdgeAesniCryptoEngineDown | 1.3.6.1.4.1.6876.90.1.2.4.0.36 | A notification generated when AESNI crypto engine is down. Action required: None | ||
| NTF vmwNsxMEdgeVmOom | 1.3.6.1.4.1.6876.90.1.2.4.0.37 | A notification generated when Edge VM is out of memory. The Edge is rebooting in 3 seconds. Action required: Collect tech support for further analysis. | ||
| NTF vmwNsxMEdgeFileSysRo | 1.3.6.1.4.1.6876.90.1.2.4.0.38 | A notification generated when Edge file system is read only. Action required: Check datastore issues, once resolved force sync is required. | ||
| NTF vmwNsxMEdgeHaCommDisconnected | 1.3.6.1.4.1.6876.90.1.2.4.0.39 | A notification generated when Edge HighAvailability communication channel is disconnected from peer node. Action required: None | ||
| NTF vmwNsxMEdgeHaSwitchOverSelf | 1.3.6.1.4.1.6876.90.1.2.4.0.40 | A notification generated when High Availability is disabled for NSX Edge. The primary NSX Edge VM has its state transitioned from ACTIVE to SELF. High Availability (HA) ensures that NSX Edge services are always available, by deploying an additional Edge VM for failover. The primary NSX Edge VM is the ACTIVE node and the secondary VM is the STANDBY node. Whenever the ACTIVE VM is unreachable on account of VM powered off or network connectivity issues, the STANDBY VM takes over the ACTIVE vm's role. In the event NSX Edge High Availability is disabled, the STANDBY VM is deleted and the ACTIVE VM continues to function with its ACTIVE state transitioned to SELF. Action required: None | ||
| NTF vmwNsxMEdgeHaSwitchOverActive | 1.3.6.1.4.1.6876.90.1.2.4.0.41 | A notification generated when High Availability switch over has happened for NSX Edge. The secondary NSX Edge VM has its state transitioned from STANDBY to ACTIVE. High Availability (HA) ensures that NSX Edge services are always available, by deploying an additional Edge VM for failover. The primary NSX Edge VM is the ACTIVE node and the secondary VM is the STANDBY node. Whenever the ACTIVE VM is unreachable on account of VM powered off or network connectivity issues, the STANDBY VM takes over the ACTIVE vm's role. Action required: None | ||
| NTF vmwNsxMEdgeHaSwitchOverStandby | 1.3.6.1.4.1.6876.90.1.2.4.0.42 | A notification generated when High Availability switch over has happened for NSX Edge. The primary NSX Edge VM has its state transitioned from ACTIVE to STANDBY. High Availability (HA) ensures that NSX Edge services are always available, by deploying an additional Edge VM for failover. The primary NSX Edge VM is the ACTIVE node and the secondary VM is the STANDBY node. Whenever the ACTIVE VM is unreachable on account of VM powered off or network connectivity issues, the STANDBY VM takes over the ACTIVE vm's role. When connectivity is re-established between the NSX Edge VM's, one of the VM's state is transitioned from ACTIVE to STANDBY. Action required: None | ||
| NTF vmwNsxMEdgeMonitorProcessFailure | 1.3.6.1.4.1.6876.90.1.2.4.0.43 | A notification generated when Edge process monitor detected a process failure. Action required: Collect tech support logs for further analysis. | ||
| NTF vmwNsxMLbVirtualServerPoolUp | 1.3.6.1.4.1.6876.90.1.2.4.0.44 | A notification generated when LoadBalancer virtualServer/pool is up. Action required: None | ||
| NTF vmwNsxMLbVirtualServerPoolDown | 1.3.6.1.4.1.6876.90.1.2.4.0.45 | A notification generated when LoadBalancer virtualServer/pool is down. | ||
| NTF vmwNsxMLbVirtualServerPoolWrong | 1.3.6.1.4.1.6876.90.1.2.4.0.46 | A notification generated when LoadBalancer virtualServer/pool state is wrong. | ||
| NTF vmwNsxMLbPoolWarning | 1.3.6.1.4.1.6876.90.1.2.4.0.47 | A notification generated when LoadBalancer pool changed to a warning state. | ||
| NTF vmwNsxMIpsecChannelUp | 1.3.6.1.4.1.6876.90.1.2.4.0.48 | A notification generated when IPsec Channel is up. Action required: None | ||
| NTF vmwNsxMIpsecChannelDown | 1.3.6.1.4.1.6876.90.1.2.4.0.49 | A notification generated when IPsec Channel is down. Action required: Collect tech support logs for further analysis. | ||
| NTF vmwNsxMIpsecTunnelUp | 1.3.6.1.4.1.6876.90.1.2.4.0.50 | A notification generated when IPsec Tunnel is up. Action required: None | ||
| NTF vmwNsxMIpsecTunnelDown | 1.3.6.1.4.1.6876.90.1.2.4.0.51 | A notification generated when IPsec Tunnel is down. Action required: Collect tech support logs for further analysis. | ||
| NTF vmwNsxMIpsecChannelUnknown | 1.3.6.1.4.1.6876.90.1.2.4.0.52 | A notification generated when IPsec Channel status is unknown. Action required: Collect tech support logs for further analysis. | ||
| NTF vmwNsxMIpsecTunnelUnknown | 1.3.6.1.4.1.6876.90.1.2.4.0.53 | A notification generated when IPsec Tunnel status is unknown. Action required: Collect tech support logs for further analysis. | ||
| NTF vmwNsxMGlobalLbMemberUp | 1.3.6.1.4.1.6876.90.1.2.4.0.54 | A notification generated when Global Loadbalancer member status is up. Action required: None | ||
| NTF vmwNsxMGlobalLbMemberWarning | 1.3.6.1.4.1.6876.90.1.2.4.0.55 | A notification generated when Global Loadbalancer member status is warning. | ||
| NTF vmwNsxMGlobalLbMemberDown | 1.3.6.1.4.1.6876.90.1.2.4.0.56 | A notification generated when Global Loadbalancer member status is down. | ||
| NTF vmwNsxMGlobalLbMemberUnknown | 1.3.6.1.4.1.6876.90.1.2.4.0.57 | A notification generated when Global Loadbalancer member status is unknown. | ||
| NTF vmwNsxMGlobalLbPeerUp | 1.3.6.1.4.1.6876.90.1.2.4.0.58 | A notification generated when Global Loadbalancer peer status is up. Action required: None | ||
| NTF vmwNsxMGlobalLbPeerDown | 1.3.6.1.4.1.6876.90.1.2.4.0.59 | A notification generated when Global Loadbalancer peer status is down. | ||
| NTF vmwNsxMDhcpServiceDisabled | 1.3.6.1.4.1.6876.90.1.2.4.0.60 | A notification generated when DHCP Relay Service is disabled. | ||
| NTF vmwNsxMEdgeResourceReservationFailure | 1.3.6.1.4.1.6876.90.1.2.4.0.61 | Insufficient CPU and/or Memory Resources available on Host or Resource Pool, during resource reservation at the time of NSX Edge deployment. Resources are explicitly reserved to ensure sufficient resources are available for NSX Edge to service High Availability. User can view the available resources vs reserved resources by navigating to the page Home > Hosts and Clusters > [Cluster-name] > Monitor > Resource Reservation. Action required: After checking available resources, re-specify the resources as part of appliance configuration so that resource reservation succeeds. | ||
| NTF vmwNsxMEdgeSplitBrainDetected | 1.3.6.1.4.1.6876.90.1.2.4.0.62 | Split Brain detected for NSX Edge with HighAvailability. NSX Edge VM's configured for High Availability are unable to determine if the other VM is alive due to network failure. In such scenario, both the VM's think the other is not alive and take on the ACTIVE state. This may cause network disruption. Action required: User will need to check network infrastructure (virtual and physical) to look for any failures, specially on the interfaces and the path configured for HA. | ||
| NTF vmwNsxMEdgeSplitBrainRecovered | 1.3.6.1.4.1.6876.90.1.2.4.0.63 | Resolved Split Brain for NSX Edge with HighAvailability. The network path used by the NSX Edge VM's High Availability has been re-established. NSX Edge VM's are able to communicate with each other, and one of the VM has taken the STANDBY role, resolving the ACTIVE-ACTIVE split brain scenario. Action required: None | ||
| NTF vmwNsxMEdgeSplitBrainRecoveryAttempt | 1.3.6.1.4.1.6876.90.1.2.4.0.64 | Attempted Split Brain resolution for NSX Edge. Split Brain recovery will be attempted on NSX Edge versions prior to 6.2.3, which are not based on BFD. Action required: None | ||
| vmwNsxMEndpoint | 1.3.6.1.4.1.6876.90.1.2.5 | Notifications that are Endpoint related will have this OID prefix. | ||
| vmwNsxMEndpointPrefix | 1.3.6.1.4.1.6876.90.1.2.5.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for Endpoint module. | ||
| NTF vmwNsxMEndpointThinAgentEnabled | 1.3.6.1.4.1.6876.90.1.2.5.0.1 | A notification generated when Thin agent is enabled. | ||
| NTF vmwNsxMGuestIntrspctnEnabled | 1.3.6.1.4.1.6876.90.1.2.5.0.2 | A notification generated when Guest Introspection solution is enabled. | ||
| NTF vmwNsxMGuestIntrspctnIncompatibleEsx | 1.3.6.1.4.1.6876.90.1.2.5.0.3 | A notification generated when Guest Introspection solution was contacted by an incompatible version of the ESX module. | ||
| NTF vmwNsxMGuestIntrspctnEsxConnFailed | 1.3.6.1.4.1.6876.90.1.2.5.0.4 | A notification generated when connection between the ESX module and the Guest Introspection solution failed. | ||
| NTF vmwNsxMGuestIntrspctnStatusRcvFailed | 1.3.6.1.4.1.6876.90.1.2.5.0.5 | A notification generated when failed to receive status from Guest Introspection solution. | ||
| NTF vmwNsxMEsxModuleEnabled | 1.3.6.1.4.1.6876.90.1.2.5.0.6 | A notification generated when ESX module is enabled. | ||
| NTF vmwNsxMEsxModuleUninstalled | 1.3.6.1.4.1.6876.90.1.2.5.0.7 | A notification generated when ESX module is uninstalled. | ||
| NTF vmwNsxMGuestIntrspctnHstMxMssngRep | 1.3.6.1.4.1.6876.90.1.2.5.0.8 | A notification generated when Guest Introspection host MUX is missing report. | ||
| NTF vmwNsxMEndpointUndefined | 1.3.6.1.4.1.6876.90.1.2.5.0.9 | A notification generated when Endpoint is undefined. | ||
| vmwNsxMEam | 1.3.6.1.4.1.6876.90.1.2.6 | Notifications that are Eam related will have this OID prefix. | ||
| vmwNsxMEamPrefix | 1.3.6.1.4.1.6876.90.1.2.6.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for Eam module. | ||
| NTF vmwNsxMEamGenericAlarm | 1.3.6.1.4.1.6876.90.1.2.6.0.1 | EAM reports problems to NSX during vib/service VM install/upgrade as these traps. Action required: Use resolve API to resolve the Alarm. Frequency of traps: N times per cluster per user action, where N is number of hosts in a cluster. | ||
| vmwNsxMFabric | 1.3.6.1.4.1.6876.90.1.2.7 | Notifications that are Fabric related will have this OID prefix. | ||
| vmwNsxMFabricPrefix | 1.3.6.1.4.1.6876.90.1.2.7.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for Fabric module. | ||
| NTF vmwNsxMFabricDplymntStatusChanged | 1.3.6.1.4.1.6876.90.1.2.7.0.1 | The status of a service on a cluster has changed. It can change to RED(Failure), GREEN(Success), YELLOW(in-progress). Action required: RED state would be accompanied with an EAM Alarm/Event/Trap, that indicates root cause. Use resolver API to fix it. Frequency of traps: Once per state change. State could change 2-3 times per user operation [Deploy/Undeploy/Update] | ||
| NTF vmwNsxMFabricDplymntUnitCreated | 1.3.6.1.4.1.6876.90.1.2.7.0.2 | NSX Manager has created the required objects for deploying a service on a cluster. This would be followed by deployment of the service on all hosts in the cluster. Action required: None Frequency: Once per cluster | ||
| NTF vmwNsxMFabricDplymntUnitUpdated | 1.3.6.1.4.1.6876.90.1.2.7.0.3 | NSX Manager has made changes in the objects required for deploying a service on a cluster. This would be followed by updation of the service on all hosts in the cluster. Action required: None Frequency of traps: Once per cluster per user operation [Update] | ||
| NTF vmwNsxMFabricDplymntUnitDestroyed | 1.3.6.1.4.1.6876.90.1.2.7.0.4 | A service has been removed from all hosts in a cluster. NSX Manager has deleted the objects for the service on the cluster. Action required: None Frequency of traps: Once per cluster | ||
| NTF vmwNsxMDataStoreNotCnfgrdOnHost | 1.3.6.1.4.1.6876.90.1.2.7.0.5 | Datastore could not be configured on host, probably its not connected. Action required: Ensure that datastore is connected to the host. Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: Once per cluster per user operation [Deploy]. | ||
| NTF vmwNsxMFabricDplymntInstallationFailed | 1.3.6.1.4.1.6876.90.1.2.7.0.6 | Installation of service failed, please check if ovf/vib urls are accessible, in correct format and all the properties in ovf environment have been configured in service attributes. Please check logs for details. Action required: Ensure that ovf/vib urls accessible from VC and are in correct format. Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: Once per cluster per user operation [Deploy]. | ||
| NTF vmwNsxMFabricAgentCreated | 1.3.6.1.4.1.6876.90.1.2.7.0.7 | The service has been successfully installed on a host. Action required: None Frequency of traps: N times per cluster, where N is number of hosts in a cluster. | ||
| NTF vmwNsxMFabricAgentDestroyed | 1.3.6.1.4.1.6876.90.1.2.7.0.8 | The service has been successfully removed from a host. Action required: None Frequency of traps: N times per cluster, where N is number of hosts in a cluster. | ||
| NTF vmwNsxMFabricSrvceNeedsRedplymnt | 1.3.6.1.4.1.6876.90.1.2.7.0.9 | Service will need to be redeployed as the location of the OVF / VIB bundles to be deployed has changed. Action required: Use resolve API to resolve the Alarm. Service will be redeployed. Frequency of traps: N times per NSX Manager IP change, where N is number of cluster and service combinations deployed. | ||
| NTF vmwNsxMUpgradeOfDplymntFailed | 1.3.6.1.4.1.6876.90.1.2.7.0.10 | Upgrade of deployment unit failed, please check if ovf/vib urls are accessible, in correct format and all the properties in ovf environment have been configured in service attributes. Please check logs for details. Action required: Ensure that ovf/vib urls accessible from VC and are in correct format. Use resolve API to resolve the Alarm. Service will be redeployed. Frequency of traps: Once per cluster per user operation [Upgrade] | ||
| NTF vmwNsxMFabricDependenciesNotInstalled | 1.3.6.1.4.1.6876.90.1.2.7.0.11 | The service being installed is dependent on another service that has not yet been installed. Action required: Deploy the required service on the cluster. Frequency of traps: Once per cluster per user operation [Deploy] | ||
| NTF vmwNsxMFabricErrorNotifSecBfrUpgrade | 1.3.6.1.4.1.6876.90.1.2.7.0.12 | Error while notifying security solution before upgrade. The solution may not be reachable/responding. Action required: Ensure that solution urls are accessible from NSX. Use resolve API to resolve the Alarm. Service will be redeployed. Frequency of traps: Once per cluster per user operation [Upgrade] | ||
| NTF vmwNsxMFabricErrCallbackNtRcvdUpgrade | 1.3.6.1.4.1.6876.90.1.2.7.0.13 | Did not receive callback from security solution for upgrade notification even after timeout. Action required: Ensure that solution urls are accessible from NSX, and NSX is reachable from the solution. Use resolve API to resolve the Alarm. Service will be redeployed. Frequency : Once per cluster per user operation [Upgrade] | ||
| NTF vmwNsxMFabricErrCallbackNtRcvdUninstall | 1.3.6.1.4.1.6876.90.1.2.7.0.14 | Uninstallation of service failed. Action required: Ensure that solution urls are accessible from NSX, and NSX is reachable from the solution. Use resolve API to resolve the Alarm. Service will be removed. Frequency of traps: Once per cluster per user operation [Uninstall] | ||
| NTF vmwNsxMFabricUninstallServiceFailed | 1.3.6.1.4.1.6876.90.1.2.7.0.15 | Error while notifying security solution before uninstall. Resolve to notify once again, or delete to uninstall without notification. Action required: Ensure that solution urls are accessible from NSX, and NSX is reachable from the solution. Use resolve API to resolve the Alarm. Service will be removed. Frequency of traps: Once per cluster per user operation [Uninstall] | ||
| NTF vmwNsxMFabricErrorNotifSecBfrUninstall | 1.3.6.1.4.1.6876.90.1.2.7.0.16 | Error while notifying security solution before uninstall. Resolve to notify once again, or delete to uninstall without notification. Action required: Ensure that solution urls are accessible from NSX, and NSX is reachable from the solution. Use resolve API to resolve the Alarm. Service will be removed. Frequency of traps: Once per cluster per user operation [Uninstall] | ||
| NTF vmwNsxMFabricServerRebootUninstall | 1.3.6.1.4.1.6876.90.1.2.7.0.17 | Server rebooted while security solution notification for uninstall was going on. Action required: Ensure that solution urls are accessible from NSX. Use resolve API to resolve the Alarm. Service will be uninstalled. Frequency of traps: Once per cluster per user operation [Uninstall] | ||
| NTF vmwNsxMFabricServerRebootUpgrade | 1.3.6.1.4.1.6876.90.1.2.7.0.18 | Server rebooted while security solution notification for upgrade was going on. Action required: Ensure that solution urls are accessible from NSX. Use resolve API to resolve the Alarm. Service will be redeployed. Frequency of traps: Once per cluster per user operation [Upgrade] | ||
| NTF vmwNsxMFabricConnEamFailed | 1.3.6.1.4.1.6876.90.1.2.7.0.19 | NSX Manager relies on the ESX Agent Manager service in VC for deploying/monitoring NSX vibs on ESX. The connection to this EAM service has gone down. This could be due to EAM service or VC restart/stop or an issue in the EAM service. Action required: In the NSX UI, traverse to Manage, then NSX Management Service. Verify that the status of VC connection on this page is Green. Use the VC IP to verify that EAM is UP by visiting https:///eam/mob. Frequency of traps: Once per switch from success to failed EAM connection | ||
| NTF vmwNsxMFabricConnEamRestored | 1.3.6.1.4.1.6876.90.1.2.7.0.20 | NSX Manager relies on the EAM service in VC for deploying/monitoring NSX vibs on ESX. The connection of NSX to this EAM service was re-established successfully. Action required: None Frequency of traps: Once per switch from failed to success EAM connection | ||
| NTF vmwNsxMFabricPreUninstallCleanUpFailed | 1.3.6.1.4.1.6876.90.1.2.7.0.21 | Pre Uninstall cleanup failed. Action required: Use resolve API to resolve the Alarm. Service will be removed. Frequency of traps: Once per cluster per user operation [Uninstall] | ||
| NTF vmwNsxMFabricBackingEamNotFound | 1.3.6.1.4.1.6876.90.1.2.7.0.22 | The backing EAM agency for this deployment could not be found. It is possible that the VC services may still be initializing. Please try to resolve the alarm to check existence of the agency. In case you have deleted the agency manually, please delete the deployment entry from NSX. Action required: Use resolve API to check existence of the agency, if backing agency exists in EAM, else delete the deployment entry from NSX. Frequency of traps: Once per cluster. | ||
| vmwNsxMDepPlugin | 1.3.6.1.4.1.6876.90.1.2.8 | Notifications that are DeploymentPlugin related will have this OID prefix. | ||
| vmwNsxMDepPluginPrefix | 1.3.6.1.4.1.6876.90.1.2.8.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for DeploymentPlugin module. | ||
| NTF vmwNsxMDepPluginIpPoolExhausted | 1.3.6.1.4.1.6876.90.1.2.8.0.1 | When deploying Guest Introspection or other VM based service with static IP, NSX Manager needs to have a IP pool, for IP assignment to the VM. This pool has been exhausted, and new service VMs cannot be provisioned. Action required: Traverse to the Networking & Security page on VMWare vSphere Web Client, then go to Installation, followed by Service Deployments. Note the IP pool name for the failed service. Now traverse to NSX Managers, then go to Manage tab, followed by Grouping Objects sub-tab. Click on IP Pools, and add more Ips to the static IP pool. Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: N times per cluster, where N is number of hosts in the cluster. | ||
| NTF vmwNsxMDepPluginGenericAlarm | 1.3.6.1.4.1.6876.90.1.2.8.0.2 | Deployment plugin generic alarm. Action required: Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: N times per cluster, where N is number of hosts in the cluster. | ||
| NTF vmwNsxMDepPluginGenericException | 1.3.6.1.4.1.6876.90.1.2.8.0.3 | Deployment plugin generic exception alarm. Action required: Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: N times per cluster, where N is number of hosts in the cluster. | ||
| NTF vmwNsxMDepPluginVmReboot | 1.3.6.1.4.1.6876.90.1.2.8.0.4 | VM needs to be rebooted for some changes to be made/take effect. Action required: Use resolve API to resolve the Alarm. Frequency of traps: N times per cluster, where N is number of hosts in the cluster. | ||
| vmwNsxMMessaging | 1.3.6.1.4.1.6876.90.1.2.9 | Notifications that are Messaging related will have this OID prefix. | ||
| vmwNsxMMessagingPrefix | 1.3.6.1.4.1.6876.90.1.2.9.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for Messaging module. | ||
| NTF vmwNsxMMessagingConfigFailed | 1.3.6.1.4.1.6876.90.1.2.9.0.1 | A notification generated when host messaging configuration failed. | ||
| NTF vmwNsxMMessagingReconfigFailed | 1.3.6.1.4.1.6876.90.1.2.9.0.2 | A notification generated when host messaging connection reconfiguration failed. | ||
| NTF vmwNsxMMessagingConfigFailedNotifSkip | 1.3.6.1.4.1.6876.90.1.2.9.0.3 | A notification generated when host messaging configuration failed and notifications were skipped. | ||
| NTF vmwNsxMMessagingInfraUp | 1.3.6.1.4.1.6876.90.1.2.9.0.4 | Manager runs a heartbeat with all hosts it manages. Missing heartbeat responses from a host indicate a communication issue between manager and the host. Such instances are indicated by event code 391002. When the communication is restored after such an instance, it is indicated by this event/trap. Action required: Refer to KB article https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2133897 Frequency of traps: Will be seen within 3 minutes of communication being restored between manager and a host. URL: https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2133897 | ||
| NTF vmwNsxMMessagingInfraDown | 1.3.6.1.4.1.6876.90.1.2.9.0.5 | Manager runs a heartbeat with all hosts it manages. Missing heartbeat responses from a host indicate a communication issue between manager and the host. In the case of such a communication issue, this trap will be sent. Action required: Refer to KB article https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2133897 Frequency of traps: Will be seen within 6 minutes of a communication failure between manager and a host. URL: https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2133897 | ||
| NTF vmwNsxMMessagingDisabled | 1.3.6.1.4.1.6876.90.1.2.9.0.6 | A messaging client such as a Host, an Edge appliance or a USVM appliance is expected to change its password within 2 hours of being prepped or deployed. If the password isn't changed in this duration, the messaging account for the client is disabled. Action required: This event will indicate communication issue between the manager and the client. Verify if the client is running. If running, in case of a Host, re-sync messaging. In case of an Edge or a USVM, redeploy. Frequency of traps: Will be seen 2 hours after prep, host re-sync or deployment of appliance. URL: https://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2133897 | ||
| vmwNsxMServiceComposer | 1.3.6.1.4.1.6876.90.1.2.10 | Notifications that are ServiceComposer related will have this OID prefix. | ||
| vmwNsxMServiceComposerPrefix | 1.3.6.1.4.1.6876.90.1.2.10.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for ServiceComposer module. | ||
| NTF vmwNsxMServiceComposerPolicyOutOfSync | 1.3.6.1.4.1.6876.90.1.2.10.0.1 | Service Composer encountered an error while attempting to enforce rules on this Policy. Action required: Administrator needs to check the rules on the given Policy for any errors, as reported in the message. After fixing the rules in the Policy, user would need to resolve the alarm to bring this Policy back in sync. Policy's alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once, if an error is encountered while enforcing the Policy. | ||
| NTF vmwNsxMServiceComposerPolicyDeleted | 1.3.6.1.4.1.6876.90.1.2.10.0.2 | A Policy got deleted as a result of the internal SecurityGroup, over which the Policy was created, got deleted. Frequency of traps: This event is generated once every time any internal SecurityGroup, that is being consumed by a policy, gets deleted. | ||
| NTF vmwNsxMServiceComposerFirewallPolicyOutOfSync | 1.3.6.1.4.1.6876.90.1.2.10.0.3 | Service Composer encountered an error while attempting to enforce Firewall rules on this Policy. Firewall related changes on this Policy will not take effect, until this alarm is resolved. Action required: Administrator needs to check the rules on the given Policy for any errors, as reported in the message. After fixing the rules in the Policy, user would need to resolve the alarm to bring this Policy back in sync. Policy's alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once, if an error is encountered while enforcing the Policy. | ||
| NTF vmwNsxMServiceComposerNetworkPolicyOutOfSync | 1.3.6.1.4.1.6876.90.1.2.10.0.4 | Service Composer encountered an error while attempting to enforce Network Introspection rules on this Policy. Network Introspection related changes on this Policy will not take effect, until this alarm is resolved. Action required: Administrator needs to check the rules on the given Policy for any errors, as reported in the message. After fixing the rules in the Policy, user would need to resolve the alarm to bring this Policy back in sync. Policy's alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once, if an error is encountered while enforcing the Policy. | ||
| NTF vmwNsxMServiceComposerGuestPolicyOutOfSync | 1.3.6.1.4.1.6876.90.1.2.10.0.5 | Service Composer encountered an error while attempting to enforce Guest Introspection rules on this Policy. Guest Introspection related changes on this Policy will not take effect, until this alarm is resolved. Action required: Administrator needs to check the rules on the given Policy for any errors, as reported in the message. After fixing the rules in the Policy, user would need to resolve the alarm to bring this Policy back in sync. Policy's alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once, if an error is encountered while enforcing the Policy. | ||
| NTF vmwNsxMServiceComposerOutOfSync | 1.3.6.1.4.1.6876.90.1.2.10.0.6 | Service Composer encountered an error synchronizing Policies. Any changes on Service Composer will not be pushed to Firewall/Network Introspection Services, until this alarm is resolved. Action required: Administrator needs to check Policies and/or Firewall sections for any errors, as reported in the message. After fixing the errors, user would need to resolve the alarm to bring Service Composer back in sync. Alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once, whenever an error is encountered. | ||
| NTF vmwNsxMServiceComposerOutOfSyncRebootFailure | 1.3.6.1.4.1.6876.90.1.2.10.0.7 | Service Composer encountered an error while synchronizing Policies on reboot. Action required: Administrator needs to check Policies and/or Firewall config for any errors, as reported in the message. After fixing the errors, user would need to resolve the alarm to bring Service Composer back in sync. Alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once on NSX Manager reboot, if an error is encountered. | ||
| NTF vmwNsxMServiceComposerOutOfSyncDraftRollback | 1.3.6.1.4.1.6876.90.1.2.10.0.8 | Service Composer went out of sync due to rollback of drafts from Firewall. Any changes on Service Composer will not be pushed to Firewall/Network Introspection Services, until this alarm is resolved. Action required: Administrator needs to resolve the alarm to bring Service Composer back in sync. Alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once, whenever Firewall config is reverted to an older version of drafts. | ||
| NTF vmwNsxMServiceComposerOutOfSyncSectionDeletionFailure | 1.3.6.1.4.1.6876.90.1.2.10.0.9 | Service Composer encountered an error while deleting the section corresponding to the Policy. This generally happens if third party(NetX) service's Manager is not reachable. Action required: Administrator needs to check connectivity with third party(NetX) service's Manager. Once the connectivity is restored, user would need to resolve the alarm. Alarm can either be resolved from Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once if a failure is encountered while deleting a Policy's section on Policy deletion. | ||
| NTF vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailure | 1.3.6.1.4.1.6876.90.1.2.10.0.10 | Service Composer encountered an error reordering sections to reflect Policy's precedence change. This generally happens if there are Alarms on any other Policy. Action required: Administrator needs to check Policies and/or Firewall sections for any errors, as reported in the message. After fixing the errors, user would need to resolve the alarm. Alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once if a failure is encountered while reordering section to reflect precedence change. | ||
| NTF vmwNsxMServiceComposerOutOfSyncDraftSettingFailure | 1.3.6.1.4.1.6876.90.1.2.10.0.11 | Service Composer encountered an error while initializing auto save drafts setting. Action required: Administrator needs to check Policies and/or Firewall sections for any errors, as reported in the message. After fixing the errors, user would need to resolve the alarm. Alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once if a failure is encountered while initializing auto save drafts setting. | ||
| vmwNsxMSvmOperations | 1.3.6.1.4.1.6876.90.1.2.11 | Notifications that are SvmOperations related will have this OID prefix. | ||
| vmwNsxMSvmOperationsPrefix | 1.3.6.1.4.1.6876.90.1.2.11.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for SvmOperations module. | ||
| NTF vmwNsxMInconsistentSvmAlarm | 1.3.6.1.4.1.6876.90.1.2.11.0.1 | Service VMs are deployed per ESX host, to provide functionality like guest introspection and McAfee/Trend virus checking in VMs on the host. An issue is detected with the state of the deployed Service VM. Follow instructions in http://kb.vmware.com/kb/2125482 to analyze the logs further. Warning: Resolving this alarm will delete the VM. After deletion you will see a different alarm saying VM is deleted. If you resolve same, it will reinstall the VM. If redeployment of the VM does not fix the original issue, the original alarm will be added back immediately. Action required: Use resolve API to resolve the Alarm. Frequency of traps: Once per host. | ||
| NTF vmwNsxMSvmRestartAlarm | 1.3.6.1.4.1.6876.90.1.2.11.0.2 | Service VMs are deployed per ESX host, to provide functionality like guest introspection and McAfee/Trend virus checking in VMs on the host. An issue is detected with the state of the deployed Service VM. Follow instructions in http://kb.vmware.com/kb/2125482 to analyze the logs further. Warning: Resolving this alarm will restart the VM. If the root cause here is not solved, the same alarm will be added back immediately. Action required: Use resolve API to resolve the Alarm. Frequency of traps: Once per host. | ||
| NTF vmwNsxMSvmAgentUnavailable | 1.3.6.1.4.1.6876.90.1.2.11.0.3 | An issue is detected while marking agent as available. Kindly check the logs. Resolving this alarm will attempt to mark the agent as available. Action required: Use resolve API to resolve the Alarm. Frequency of traps: Once per host. | ||
| vmwNsxMTranslation | 1.3.6.1.4.1.6876.90.1.2.12 | Notifications that are Translation related will have this OID prefix. | ||
| vmwNsxMTranslationPrefix | 1.3.6.1.4.1.6876.90.1.2.12.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for Translation module. | ||
| NTF vmwNsxMVmAddedToSg | 1.3.6.1.4.1.6876.90.1.2.12.0.1 | A VM has got added to the SecurityGroup. Frequency of traps: Once for every VM getting added to any SecurityGroup. | ||
| NTF vmwNsxMVmRemovedFromSg | 1.3.6.1.4.1.6876.90.1.2.12.0.2 | A VM has got removed from the SecurityGroup. Frequency of traps: Once for every VM getting removed from any SecurityGroup. | ||
| vmwNsxMUniversalSync | 1.3.6.1.4.1.6876.90.1.2.13 | Notifications that are UniversalSync related will have this OID prefix. | ||
| vmwNsxMUniversalSyncPrefix | 1.3.6.1.4.1.6876.90.1.2.13.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for UniversalSync module. | ||
| NTF vmwNsxMFullUniversalSyncFailed | 1.3.6.1.4.1.6876.90.1.2.13.0.1 | A failure is encountered when doing full sync of universal objects on a secondary NSX manager. IP address of the secondary NSX manager is present in event's message variable. Action required: Kindly check NSX manager logs on the secondary NSX manager on which the full sync has failed. Frequency of traps: This trap is generated once per NSX manager on which full sync failure is seen. | ||
| NTF vmwNsxMSecondaryDown | 1.3.6.1.4.1.6876.90.1.2.13.0.2 | Secondary NSX manager is unreachable. Action required: Kindly check if NSX manager is running and is reachable from primary NSX manager. IP address of the secondary NSX manager is present in event's message variable. Frequency of traps: This trap is generated once per NSX manager for which connection issue is seen. | ||
| NTF vmwNsxMUniversalSyncFailedForEntity | 1.3.6.1.4.1.6876.90.1.2.13.0.3 | A failure is encountered when doing sync of universal object on a secondary NSX manager. IP address of the secondary NSX manager is present in event's message variable. Action required: Kindly check NSX manager logs on the secondary NSX manager on which the sync has failed. Frequency of traps: This trap is generated once per universal object on a NSX manager on which sync failure is seen. | ||
| vmwNsxMAsyncRest | 1.3.6.1.4.1.6876.90.1.2.14 | Notifications that are AsyncRest related will have this OID prefix. | ||
| vmwNsxMAsyncRestPrefix | 1.3.6.1.4.1.6876.90.1.2.14.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for AsyncRest module. | ||
| NTF vmwNsxMServerUp | 1.3.6.1.4.1.6876.90.1.2.14.0.1 | Denotes that NSX manager server is up and in running state, Informs clients of NSX Manager of the current state. Action required: None Frequency of traps: Once for every query | ||
| vmwNsxMExtensionRegistration | 1.3.6.1.4.1.6876.90.1.2.15 | Notifications that are ExtensionRegistration related will have this OID prefix. | ||
| vmwNsxMExtensionRegistrationPrefix | 1.3.6.1.4.1.6876.90.1.2.15.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for ExtensionRegistration module. | ||
| NTF vmwNsxMExtensionRegistered | 1.3.6.1.4.1.6876.90.1.2.15.0.1 | Registers NSX manager as a vCenter extenstion. This is applicable when no other NSX Manager is registered with vCenter and the current NSX manager is the one registering with vCenter. Action required: None Frequency of traps: Only once when the extension is registered for the very first time. | ||
| NTF vmwNsxMExtensionUpdated | 1.3.6.1.4.1.6876.90.1.2.15.0.2 | Updates the vCenter extension registration with the new NSX Manager. This is applicable when there already exists another NSX manager that is registered as a vCenter extension and the current one overwrites it. Action required: None Frequency of traps: Every time a NSX Manager registers as a vCenter extension when there already exists another NSX manager registered with vCenter | ||
| vmwNsxMDlp | 1.3.6.1.4.1.6876.90.1.2.16 | Notifications that are Dlp related will have this OID prefix. | ||
| vmwNsxMDlpPrefix | 1.3.6.1.4.1.6876.90.1.2.16.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for Dlp module. | ||
| NTF vmwNsxMDataSecScanStarted | 1.3.6.1.4.1.6876.90.1.2.16.0.1 | A notification generated when NSX Data Security scan started on VirtualMachine. | ||
| NTF vmwNsxMDataSecScanEnded | 1.3.6.1.4.1.6876.90.1.2.16.0.2 | A notification generated when NSX Data Security scan ended on VirtualMachine. | ||
| vmwNsxMSamSystem | 1.3.6.1.4.1.6876.90.1.2.17 | Notifications that are SamSystem related will have this OID prefix. | ||
| vmwNsxMSamSystemPrefix | 1.3.6.1.4.1.6876.90.1.2.17.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for SamSystem module. | ||
| NTF vmwNsxMSamDataCollectionEnabled | 1.3.6.1.4.1.6876.90.1.2.17.0.1 | Service Activity Monitoring will start collecting data. Action required: None Frequency of traps: Event is triggered when SAM data collection state is toggled. | ||
| NTF vmwNsxMSamDataCollectionDisabled | 1.3.6.1.4.1.6876.90.1.2.17.0.2 | Service Activity Monitoring will stop collecting data. Action required: SAM data collection can be enabled to start collectiing data. Frequency of traps: Event is triggered when SAM data collection state is toggled | ||
| NTF vmwNsxMSamDataStoppedFlowing | 1.3.6.1.4.1.6876.90.1.2.17.0.3 | Service Activity Monitoring data stopped flowing from USVM Action required: Check the following - USVM log to see if heartbeats are recieved and sent - is the USVM running - is the Mux - USVM connection healthy - is the USVM - RMQ connection healthy - does the VM have endpoint driver installed Frequency of traps: Event is triggered when NSX Manager does not receives SAM data from USVM | ||
| NTF vmwNsxMSamDataResumedFlowing | 1.3.6.1.4.1.6876.90.1.2.17.0.4 | Service Activity Monitoring data resumes flowing from USVM Action required: None Frequency of traps: Event is triggered when SAM data is received from USVM. | ||
| vmwNsxMUsvm | 1.3.6.1.4.1.6876.90.1.2.18 | Notifications that are Usvm related will have this OID prefix. | ||
| vmwNsxMUsvmPrefix | 1.3.6.1.4.1.6876.90.1.2.18.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for Usvm module. | ||
| NTF vmwNsxMUsvmHeartbeatStopped | 1.3.6.1.4.1.6876.90.1.2.18.0.1 | USVM stopped sending heartbeats to management plane. Action required: Connection to NSX Manager was lost. Check why the Manager didn't send a heartbeat. Frequency of traps: Event is triggered when NSX Manager does not receives heartbeats from USVM | ||
| NTF vmwNsxMUsvmHeartbeatResumed | 1.3.6.1.4.1.6876.90.1.2.18.0.2 | USVM will start sending heartbeats to management plane. Action required: None Frequency of traps: Event is triggered when NSX Manager receives heartbeats from USVM | ||
| NTF vmwNsxMUsvmReceivedHello | 1.3.6.1.4.1.6876.90.1.2.18.0.3 | USVM sent a HELLO message to Mux Action: None Frequency of traps: Event is triggered when Epsec Mux receives HELLO message from USVM during initial connection establishement. | ||
| vmwNsxMVsmCore | 1.3.6.1.4.1.6876.90.1.2.19 | Notifications that are VsmCore related will have this OID prefix. | ||
| vmwNsxMVsmCorePrefix | 1.3.6.1.4.1.6876.90.1.2.19.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for VsmCore module. | ||
| NTF vmwNsxMUpgradeSuccess | 1.3.6.1.4.1.6876.90.1.2.19.0.1 | A notification generated when NSX Manager upgraded successfully. | ||
| NTF vmwNsxMRestoreSuccess | 1.3.6.1.4.1.6876.90.1.2.19.0.2 | A notification generated when NSX Manager restored successfully. | ||
| NTF vmwNsxMDuplicateIp | 1.3.6.1.4.1.6876.90.1.2.19.0.3 | The NSX Manager IP has been assigned to another machine Action: None Frequency: This is triggered whenever NSX Manager detects that its IP address is being used by another machine in the same network | ||
| vmwNsxMVxlan | 1.3.6.1.4.1.6876.90.1.2.20 | Notifications that are Vxlan related will have this OID prefix. | ||
| vmwNsxMVxlanPrefix | 1.3.6.1.4.1.6876.90.1.2.20.0 | This group is actually the prefix one uses when creating vmware NSX manager specific trap OID's for Vxlan module. | ||
| NTF vmwNsxMVxlanLogicalSwitchImproperlyCnfg | 1.3.6.1.4.1.6876.90.1.2.20.0.1 | This event is triggered if one or more distributed virtual port groups backing a certain Logical Switch were modified and/or removed. Or if migration of Control plane mode for a Logical Switch/Transport Zone failed. Action required: (1) If the event was triggered due to deletion/modification of backing distributed virtual port groups, then the error will be visible on Logical Switch UI page. Resolve from there will try and create missing distributed virtual port groups for the Logical Switch. (2) If event was triggered due to failure of Control plan mode migration, redo the migration for that Logical Switch or Transport Zone. Frequency of traps: Event is triggered due to user actions as explained in description. Affects: Logical Switch network traffic. | ||
| NTF vmwNsxMVxlanLogicalSwitchProperlyCnfg | 1.3.6.1.4.1.6876.90.1.2.20.0.2 | Logical Switch status has been marked good, most probably as result of resolving any errors on it. Action required: None Frequency of traps: Event is triggered when user resolves the Logical Switch error and as a result missing backing distributed virtual port groups are recreated. | ||
| NTF vmwNsxMVxlanInitFailed | 1.3.6.1.4.1.6876.90.1.2.20.0.3 | Failed to configure vmknic as a VTEP, VXLAN traffic through this interface will be dropped until this is resolved. Action required: Check the host's vmkernel.log for more details. Frequency of traps: Every time a VTEP vmknic tries to connect to it's Distributed Virtual Port. Affects: VXLAN traffic on the affected Host. | ||
| NTF vmwNsxMVxlanPortInitFailed | 1.3.6.1.4.1.6876.90.1.2.20.0.4 | Failed to configure VXLAN on the Distributed Virtual Port, the port will be disconnected. Action required: Check the host's vmkernel.log for more details. Frequency of traps: Every time a VXLAN vNic tries to connect to it's Distributed Virtual Port on the host. Affects: VXLAN traffic on the affected Host. | ||
| NTF vmwNsxMVxlanInstanceDoesNotExist | 1.3.6.1.4.1.6876.90.1.2.20.0.5 | VXLAN configuration was received for a Distributed Virtual Port, but the host has not yet enabled VXLAN on the vSphere Distributed Switch. VXLAN ports on affected Host will fail to connect until resolved. Action required: See KB 2107951 (https://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&docType=kc&externalId=2107951&sliceId=1&docTypeID=DT_KB_1_1&dialogID=40732862&stateId=0%200%2040754197) Frequency of traps: Every time any VXLAN related port (vNic or vmknic) tries to connect to it's Distributed Virtual Port on the host. Affects: VXLAN Traffic on that Host. | ||
| NTF vmwNsxMVxlanLogicalSwitchWrkngImproperly | 1.3.6.1.4.1.6876.90.1.2.20.0.6 | VTEP interface was unable to join the specified multicast address, the VTEP will be unable to receive some traffic from other hosts until this is resolved. The host will periodically retry joining the group until it is successful. Action required: Check the host's vmkernel.log for more details. Frequency of traps: NSX retries joining failed mcast groups every 5 seconds. Affects: Logical Switch associated with problem VTEP interface won't work properly. | ||
| NTF vmwNsxMVxlanTransportZoneIncorrectlyWrkng | 1.3.6.1.4.1.6876.90.1.2.20.0.7 | The IP address of a VTEP vmknic has changed. Action required: None. Frequency of traps: Every time a VTEP IP changes | ||
| NTF vmwNsxMVxlanTransportZoneNotUsed | 1.3.6.1.4.1.6876.90.1.2.20.0.8 | VTEP vmknic does not have a valid IP address assigned, all VXLAN traffic through this vmknic will be dropped. Action required: Verify the IP configuration for the interface, and the DHCP server if DHCP is used. Frequency of traps: Once per VTEP loosing it's IP address. | ||
| NTF vmwNsxMVxlanOverlayClassMissingOnDvs | 1.3.6.1.4.1.6876.90.1.2.20.0.9 | NSX packages where not installed prior to DVS configuration for VXLAN. All VXLAN ports will fail to connect until resolved. Action required: See KB 2107951 https://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&docType=kc&externalId=2107951&sliceId=1&docTypeID=DT_KB_1_1&dialogID=40732862&stateId=0%200%2040754197 Frequency of traps: Once per setting of the com.vmware.netoverlay.layer0=vxlan opaque property or whenver the host is configured for vxlan or Host reconnects to VCEnter and host has some problem. Affects: VXLAN Traffic for that Host will be affected. | ||
| NTF vmwNsxMVxlanControllerRemoved | 1.3.6.1.4.1.6876.90.1.2.20.0.10 | A notification generated when VXLAN Controller has been removed due to the connection cant be built, please check controller IP configuration and deploy again. | ||
| NTF vmwNsxMVxlanControllerConnProblem | 1.3.6.1.4.1.6876.90.1.2.20.0.11 | NSX manager detected the connection between two controller nodes is broken. Action required: It is a warning event, users need to check the controller cluster for the further steps. Check following KB 2127655 https://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&docType=kc&externalId=2127655&sliceId=1&docTypeID=DT_KB_1_1&dialogID=40732913&stateId=0%200%2040754965 to see if issue matches. Frequency of traps: Whenever the controller reports the issue. Affects: Networking might get affected. | ||
| NTF vmwNsxMVxlanControllerInactive | 1.3.6.1.4.1.6876.90.1.2.20.0.12 | Host Certification information couldn't be sent to NSX Controllers. Action required: Ensure that NSX Controller cluster is in healthy state before preparing a new Host. Invoke Controller Sync API to try and rectify this error. Frequency of traps: When a new host is prepared for NSX networking. Affects: Newly prepared Host. Communication channel between Host and NSX Controllers might have issues. | ||
| NTF vmwNsxMVxlanControllerActive | 1.3.6.1.4.1.6876.90.1.2.20.0.13 | A notification generated when Controller cluster state is now active. Controller Synchronization job is in progress. Frequency of traps: Controller cluster becomes active again from a previous inactive state. Action required: User doesnt have to take any corrective action. NSX will auto-sync the controllers. | ||
| NTF vmwNsxMVxlanVmknicMissingOrDeleted | 1.3.6.1.4.1.6876.90.1.2.20.0.14 | VXLAN vmknic is missing or deleted from host. Action required: Issue can be resolved from Logical Network Preparation - VXLAN Transport UI section. Clicking on resolve will try to rectify the issue. Frequency of traps: First time NSX Manager finds that VXLAN vmknic is missing or deleted from Host. Affects: VXLAN Traffic to/from the mentioned Host will be affected. | ||
| NTF vmwNsxMVxlanInfo | 1.3.6.1.4.1.6876.90.1.2.20.0.15 | NSX Manager will raise this event when connection between either of the following component is established/re-established (i) connection between NSX Manager and Host Firewall agent. (ii) connection between NSX Manager and Control Plane Agent. (iii) connection between Control Plane Agent to Controllers. Action required: None Frequency of traps: NSX Manager will raise this event when connection between either of the following component is established/re-established (i) connection between NSX Manager and Host Firewall agent. (ii) connection between NSX Manager and Control Plane Agent (iii) connection between Control Plane Agent to Controllers. | ||
| NTF vmwNsxMVxlanVmknicPortGrpMissing | 1.3.6.1.4.1.6876.90.1.2.20.0.16 | NSX manager detected one vxlan vmknic is missing on VC. Action required: Check the host, if that vmknic is deleted, click on the resolve button on UI, or call the remediate API (POST /api/2.0/vdn/config/host/{hostId}/vxlan/vteps?action=remediate) to recreate the vxlan vmknic. Frequency of traps: First time when vxlan vmknic is detected missing (manually deleted by user or inventory report the incorrect information) Affects: The VXLAN traffic on that host may be interrupted. | ||
| NTF vmwNsxMVxlanVmknicPortGrpAppears | 1.3.6.1.4.1.6876.90.1.2.20.0.17 | NSX manager detected one vxlan vmknic that was marked as missing has now reappeared on VC. Action required: None Frequency of traps: When that missing vmknic re-appears again. Affects: The VXLAN traffic on that host may be resumed. | ||
| NTF vmwNsxMVxlanConnDown | 1.3.6.1.4.1.6876.90.1.2.20.0.18 | This event is triggered when either of the following connections are detected down by NSX Manager: (i) connection between NSX Manager and Host Firewall agent. (ii) connection between NSX Manager and Control Plane Agent. (iii) connection between Control Plane Agent to Controllers. Action required: (i) If NSX Manager to Host Firewall Agent connection is down, check NSX Manager and Firewall Agent logs to get error details. You can try Fabric Synchronize API to try and retificy this issue. (ii) If NSX Manager to Control Plane Agent connection is down, please check NSX Manager and Control Plane Agent logs to get the error detail, check whether the Control Plane Agent process is down. (iii) If Control Plane Agent to Controllers connection is down, please go to UI Installation page to check the connection status for crossponding Host. Frequency of traps: When (i) NSX Manager looses connection with Firewall agent on host or (ii) NSX Manager losses connection with Control plane agent on host or (iii) Control plane agent on Host looses connection with NSX Controllers. Affects: VMs on that Host might get affected. | ||
| NTF vmwNsxMBackingPortgroupMissing | 1.3.6.1.4.1.6876.90.1.2.20.0.19 | NSX manager detected one backing portgroup of a logical switch is missing on VCenter. Action required: Click on the resolve button on UI or call the API (POST https:///api/2.0/vdn/virtualwires//backing?action=remediate) to recreate that backing portgroup. Frequency of traps: Whenever logical switch backing portgroup is missing on VC. Affects: VMs cannot be connected to this Logical Switch. | ||
| NTF vmwNsxMBackingPortgroupReappears | 1.3.6.1.4.1.6876.90.1.2.20.0.20 | NSX manager detected one backing portgroup of a logical switch that was missing reappears on VC. Action required: None Frequency of traps: Whenever user triggered remediate API on Logical Switch which has missing backing portgroup. | ||
| NTF vmwNsxMManagedObjectIdChanged | 1.3.6.1.4.1.6876.90.1.2.20.0.21 | NSX manager detected the Managed Objectid of one backing portgroup of a logical switch changed. Action required: None Frequnecy of traps: This typically happens when user restores a backup of Logical Switch backing portgroup. | ||
| NTF vmwNsxMHighLatencyOnDisk | 1.3.6.1.4.1.6876.90.1.2.20.0.22 | NSX manager detected some disk on a NSX Controller has high latency. Action required: Rectify the issue on specified device and controller. Frequency of traps: First time NSX detected this issue as reported by Controller. When this issue gets resolved another Informational event will be raised by NSX Manager indicating the same. Affects: NSX Controller. | ||
| NTF vmwNsxMHighLatencyOnDiskResolved | 1.3.6.1.4.1.6876.90.1.2.20.0.23 | NSX manager detected the disk high latency alert on a some disk on a NSX Controller has been resolved. Frequency of traps: First time NSX detected, previously raised disk latency issue has been resolved. | ||
| NTF vmwNsxMControllerVmPoweredOff | 1.3.6.1.4.1.6876.90.1.2.20.0.24 | NSX manager detected a Controller Virtual Machine is powered off from vCenter. Action required: Click on the 'Resolve' button on Controller page on UI or call the API (POST https:///api/2.0/vdn/controller/{controllerId}?action=remediate) to power on the Controller Virtual Machine. Frequency of traps: This event wil be raised when controller Virtual Machine is powered off from vCenter. Affects: Controller cluster status might go to disconnected if a controller Virtual Machine is powered off. Any operation that requires an active Controller Cluster may be affected. | ||
| NTF vmwNsxMControllerVmDeleted | 1.3.6.1.4.1.6876.90.1.2.20.0.25 | NSX manager detected a Controller Virtual Machine is deleted from vCenter. Action required: Click on the Resolve button on Controller page on UI or call the API (POST https:///api/2.0/vdn/controller/{controllerId}?action=remediate) to clean up NSX manager's database state. Frequency of traps: This event will be raised when Controller Virtual Machine is deleted from vCenter. Affects: Controller cluster status might go to disconnected if a controller Virtual Machine is powered off. Any operation that requires an active Controller Cluster may be affected. | ||
| NTF vmwNsxMVxlanConfigNotSet | 1.3.6.1.4.1.6876.90.1.2.20.0.26 | NSX manager detected the VXLAN configuration is not set on the host (would-block issue). And this event indicates NSX Manager tried to rectify this issue by resending the VXLAN configuration on Host. Action required: See KB 2107951 https://kb.vmware.com/selfservice/microsites/search.do?cmd=displayKC&docType=kc&externalId=2107951&sliceId=1&docTypeID=DT_KB_1_1&dialogID=40732862&stateId=0%200%2040754197 for more information. Frequency of traps: This event will generate when host preparation task is triggered for a host and Host encounters would-block issue. Affects: It is a notification, no specific guide for the next step. | ||
| vmwNsxManagerMIBConformance | 1.3.6.1.4.1.6876.90.1.99 | |||
| vmwNsxManagerMIBCompliances | 1.3.6.1.4.1.6876.90.1.99.1 | |||
| vmwNsxManagerMIBBasicCompliance | 1.3.6.1.4.1.6876.90.1.99.1.3 | The compliance statement for entities which implement VMWARE-NSX-MANAGER-MIB. | ||
| vmwNsxManagerMIBGroups | 1.3.6.1.4.1.6876.90.1.99.2 | |||
| vmwNsxManagerNotificationInfoGroup1 | 1.3.6.1.4.1.6876.90.1.99.2.2 | These objects provide details in NSX Manager notifications. | ||
| vmwNsxManagerNotificationGroup1 | 1.3.6.1.4.1.6876.90.1.99.2.3 | Group of objects describing notifications (traps, informs). |
RFC description
Describes SNMP trap notifications for VMware NSX Manager appliance in software-defined data centers.
Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.