VMWARE-NSX-MANAGER-MIB :: vmwNsxMControllerVmDeleted

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMControllerVmDeleted

vmwNsxMControllerVmDeleted

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMControllerVmDeleted

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.20.0.25

Node type: NOTIFICATION-TYPE

Description: NSX manager detected a Controller Virtual Machine is deleted from vCenter. Action required: Click on the Resolve button on Controller page on UI or call the API (POST https:///api/2.0/vdn/controller/{controllerId}?action=remediate) to clean up NSX manager's database state. Frequency of traps: This event will be raised when Controller Virtual Machine is deleted from vCenter. Affects: Controller cluster status might go to disconnected if a controller Virtual Machine is powered off. Any operation that requires an active Controller Cluster may be affected.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMControllerVmDeleted
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.20.0.25

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:62590->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (71727742) 8 days, 7:14:37.42
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMControllerVmDeleted

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMControllerVmDeleted OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.20vmwNsxMVxlanVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.20.0vmwNsxMVxlanPrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.20.0.25vmwNsxMControllerVmDeletedVMWARE-NSX-MANAGER-MIB