VMWARE-NSX-MANAGER-MIB :: vmwNsxMServiceComposerOutOfSyncSectionDeletionFailure

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMServiceComposerOutOfSyncSectionDeletionFailure

vmwNsxMServiceComposerOutOfSyncSectionDeletionFailure

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSyncSectionDeletionFailure

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.10.0.9

Node type: NOTIFICATION-TYPE

Description: Service Composer encountered an error while deleting the section corresponding to the Policy. This generally happens if third party(NetX) service's Manager is not reachable. Action required: Administrator needs to check connectivity with third party(NetX) service's Manager. Once the connectivity is restored, user would need to resolve the alarm. Alarm can either be resolved from Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once if a failure is encountered while deleting a Policy's section on Policy deletion.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSyncSectionDeletionFailure
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.10.0.9

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:65248->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (396091104) 45 days, 20:15:11.04
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSyncSectionDeletionFailure

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSyncSectionDeletionFailure OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10vmwNsxMServiceComposerVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10.0vmwNsxMServiceComposerPrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10.0.9vmwNsxMServiceComposerOutOfSyncSectionDeletionFailureVMWARE-NSX-MANAGER-MIB