VMWARE-NSX-MANAGER-MIB :: vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailure

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailure

vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailure

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailure

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.10.0.10

Node type: NOTIFICATION-TYPE

Description: Service Composer encountered an error reordering sections to reflect Policy's precedence change. This generally happens if there are Alarms on any other Policy. Action required: Administrator needs to check Policies and/or Firewall sections for any errors, as reported in the message. After fixing the errors, user would need to resolve the alarm. Alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once if a failure is encountered while reordering section to reflect precedence change.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailure
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.10.0.10

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:51631->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (85116335) 9 days, 20:26:03.35
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailure

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailure OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10vmwNsxMServiceComposerVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10.0vmwNsxMServiceComposerPrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10.0.10vmwNsxMServiceComposerOutOfSyncPrecedenceChangeFailureVMWARE-NSX-MANAGER-MIB