vmwNsxMEdgeResourceReservationFailure

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeResourceReservationFailure

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.4.0.61

Node type: NOTIFICATION-TYPE

Description: Insufficient CPU and/or Memory Resources available on Host or Resource Pool, during resource reservation at the time of NSX Edge deployment. Resources are explicitly reserved to ensure sufficient resources are available for NSX Edge to service High Availability. User can view the available resources vs reserved resources by navigating to the page Home > Hosts and Clusters > [Cluster-name] > Monitor > Resource Reservation. Action required: After checking available resources, re-specify the resources as part of appliance configuration so that resource reservation succeeds.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeResourceReservationFailure
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.4.0.61

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:63501->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (57774093) 6 days, 16:29:00.93
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeResourceReservationFailure

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeResourceReservationFailure OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.4vmwNsxMEdgeVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.4.0vmwNsxMEdgePrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.4.0.61vmwNsxMEdgeResourceReservationFailureVMWARE-NSX-MANAGER-MIB