VMWARE-NSX-MANAGER-MIB :: vmwNsxMServiceComposerOutOfSync

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMServiceComposerOutOfSync

vmwNsxMServiceComposerOutOfSync

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSync

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.10.0.6

Node type: NOTIFICATION-TYPE

Description: Service Composer encountered an error synchronizing Policies. Any changes on Service Composer will not be pushed to Firewall/Network Introspection Services, until this alarm is resolved. Action required: Administrator needs to check Policies and/or Firewall sections for any errors, as reported in the message. After fixing the errors, user would need to resolve the alarm to bring Service Composer back in sync. Alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once, whenever an error is encountered.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSync
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.10.0.6

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:58225->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (240483185) 27 days, 20:00:31.85
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSync

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerOutOfSync OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10vmwNsxMServiceComposerVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10.0vmwNsxMServiceComposerPrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10.0.6vmwNsxMServiceComposerOutOfSyncVMWARE-NSX-MANAGER-MIB