All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMEdgeHaSwitchOverSelf
vmwNsxMEdgeHaSwitchOverSelf
Module: VMWARE-NSX-MANAGER-MIB
OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeHaSwitchOverSelf
OID (numeric): 1.3.6.1.4.1.6876.90.1.2.4.0.40
Node type: NOTIFICATION-TYPE
Description: A notification generated when High Availability is disabled for NSX Edge. The primary NSX Edge VM has its state transitioned from ACTIVE to SELF. High Availability (HA) ensures that NSX Edge services are always available, by deploying an additional Edge VM for failover. The primary NSX Edge VM is the ACTIVE node and the secondary VM is the STANDBY node. Whenever the ACTIVE VM is unreachable on account of VM powered off or network connectivity issues, the STANDBY VM takes over the ACTIVE vm's role. In the event NSX Edge High Availability is disabled, the STANDBY VM is deleted and the ACTIVE VM continues to function with its ACTIVE state transitioned to SELF. Action required: None
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeHaSwitchOverSelf snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.4.0.40
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:59929->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (430389273) 49 days, 19:31:32.73 SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeHaSwitchOverSelf
Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMEdgeHaSwitchOverSelf OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6876 | vmware | VMWARE-ROOT-MIB |
| 1.3.6.1.4.1.6876.90 | vmwNsxManager | VMWARE-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6876.90.1 | vmwNsxManagerMIB | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2 | vmwNsxMNotification | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2.4 | vmwNsxMEdge | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2.4.0 | vmwNsxMEdgePrefix | VMWARE-NSX-MANAGER-MIB |