VMWARE-NSX-MANAGER-MIB :: vmwNsxMVxlanInfo

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMVxlanInfo

vmwNsxMVxlanInfo

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanInfo

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.20.0.15

Node type: NOTIFICATION-TYPE

Description: NSX Manager will raise this event when connection between either of the following component is established/re-established (i) connection between NSX Manager and Host Firewall agent. (ii) connection between NSX Manager and Control Plane Agent. (iii) connection between Control Plane Agent to Controllers. Action required: None Frequency of traps: NSX Manager will raise this event when connection between either of the following component is established/re-established (i) connection between NSX Manager and Host Firewall agent. (ii) connection between NSX Manager and Control Plane Agent (iii) connection between Control Plane Agent to Controllers.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanInfo
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.20.0.15

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:59325->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (164364221) 19 days, 0:34:02.21
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanInfo

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanInfo OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.20vmwNsxMVxlanVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.20.0vmwNsxMVxlanPrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.20.0.15vmwNsxMVxlanInfoVMWARE-NSX-MANAGER-MIB