vmwNsxMServiceComposerNetworkPolicyOutOfSync

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerNetworkPolicyOutOfSync

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.10.0.4

Node type: NOTIFICATION-TYPE

Description: Service Composer encountered an error while attempting to enforce Network Introspection rules on this Policy. Network Introspection related changes on this Policy will not take effect, until this alarm is resolved. Action required: Administrator needs to check the rules on the given Policy for any errors, as reported in the message. After fixing the rules in the Policy, user would need to resolve the alarm to bring this Policy back in sync. Policy's alarm can either be resolved from NSX Manager Service Composer UI or by using alarms API. Frequency of traps: This trap is generated only once, if an error is encountered while enforcing the Policy.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerNetworkPolicyOutOfSync
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.10.0.4

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:49757->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (219371613) 25 days, 9:21:56.13
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerNetworkPolicyOutOfSync

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMServiceComposerNetworkPolicyOutOfSync OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10vmwNsxMServiceComposerVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10.0vmwNsxMServiceComposerPrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.10.0.4vmwNsxMServiceComposerNetworkPolicyOutOfSyncVMWARE-NSX-MANAGER-MIB