All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMDepPluginIpPoolExhausted
vmwNsxMDepPluginIpPoolExhausted
Module: VMWARE-NSX-MANAGER-MIB
OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMDepPluginIpPoolExhausted
OID (numeric): 1.3.6.1.4.1.6876.90.1.2.8.0.1
Node type: NOTIFICATION-TYPE
Description: When deploying Guest Introspection or other VM based service with static IP, NSX Manager needs to have a IP pool, for IP assignment to the VM. This pool has been exhausted, and new service VMs cannot be provisioned. Action required: Traverse to the Networking & Security page on VMWare vSphere Web Client, then go to Installation, followed by Service Deployments. Note the IP pool name for the failed service. Now traverse to NSX Managers, then go to Manage tab, followed by Grouping Objects sub-tab. Click on IP Pools, and add more Ips to the static IP pool. Use resolve API to resolve the Alarm. Service will be deployed. Frequency of traps: N times per cluster, where N is number of hosts in the cluster.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMDepPluginIpPoolExhausted snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.8.0.1
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:60244->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (252368212) 29 days, 5:01:22.12 SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMDepPluginIpPoolExhausted
Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMDepPluginIpPoolExhausted OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6876 | vmware | VMWARE-ROOT-MIB |
| 1.3.6.1.4.1.6876.90 | vmwNsxManager | VMWARE-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6876.90.1 | vmwNsxManagerMIB | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2 | vmwNsxMNotification | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2.8 | vmwNsxMDepPlugin | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2.8.0 | vmwNsxMDepPluginPrefix | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2.8.0.1 | vmwNsxMDepPluginIpPoolExhausted | VMWARE-NSX-MANAGER-MIB |