All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMVxlanLogicalSwitchImproperlyCnfg
vmwNsxMVxlanLogicalSwitchImproperlyCnfg
Module: VMWARE-NSX-MANAGER-MIB
OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanLogicalSwitchImproperlyCnfg
OID (numeric): 1.3.6.1.4.1.6876.90.1.2.20.0.1
Node type: NOTIFICATION-TYPE
Description: This event is triggered if one or more distributed virtual port groups backing a certain Logical Switch were modified and/or removed. Or if migration of Control plane mode for a Logical Switch/Transport Zone failed. Action required: (1) If the event was triggered due to deletion/modification of backing distributed virtual port groups, then the error will be visible on Logical Switch UI page. Resolve from there will try and create missing distributed virtual port groups for the Logical Switch. (2) If event was triggered due to failure of Control plan mode migration, redo the migration for that Logical Switch or Transport Zone. Frequency of traps: Event is triggered due to user actions as explained in description. Affects: Logical Switch network traffic.
Examples
Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):
snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanLogicalSwitchImproperlyCnfg snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.20.0.1
Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):
snmptrapd -f -Lo -c /dev/null authCommunity log public
Example snmptrapd log entry:
zoo11-linux.zoo [UDP: [192.168.30.111]:50300->[192.168.30.10]:162]: DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (132270716) 15 days, 7:25:07.16 SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanLogicalSwitchImproperlyCnfg
Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMVxlanLogicalSwitchImproperlyCnfg OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6876 | vmware | VMWARE-ROOT-MIB |
| 1.3.6.1.4.1.6876.90 | vmwNsxManager | VMWARE-ROOT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6876.90.1 | vmwNsxManagerMIB | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2 | vmwNsxMNotification | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2.20 | vmwNsxMVxlan | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2.20.0 | vmwNsxMVxlanPrefix | VMWARE-NSX-MANAGER-MIB |
| 1.3.6.1.4.1.6876.90.1.2.20.0.1 | vmwNsxMVxlanLogicalSwitchImproperlyCnfg | VMWARE-NSX-MANAGER-MIB |