VMWARE-NSX-MANAGER-MIB :: vmwNsxMInconsistentSvmAlarm

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › VMWARE-NSX-MANAGER-MIB › vmwNsxMInconsistentSvmAlarm

vmwNsxMInconsistentSvmAlarm

Module: VMWARE-NSX-MANAGER-MIB

OID (symbolic): VMWARE-NSX-MANAGER-MIB::vmwNsxMInconsistentSvmAlarm

OID (numeric): 1.3.6.1.4.1.6876.90.1.2.11.0.1

Node type: NOTIFICATION-TYPE

Description: Service VMs are deployed per ESX host, to provide functionality like guest introspection and McAfee/Trend virus checking in VMs on the host. An issue is detected with the state of the deployed Service VM. Follow instructions in http://kb.vmware.com/kb/2125482 to analyze the logs further. Warning: Resolving this alarm will delete the VM. After deletion you will see a different alarm saying VM is deleted. If you resolve same, it will reinstall the VM. If redeployment of the VM does not fix the original issue, the original alarm will be added back immediately. Action required: Use resolve API to resolve the Alarm. Frequency of traps: Once per host.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' VMWARE-NSX-MANAGER-MIB::vmwNsxMInconsistentSvmAlarm
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.6876.90.1.2.11.0.1

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:57186->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (88379746) 10 days, 5:29:57.46
  SNMPv2-MIB::snmpTrapOID.0 = OID: VMWARE-NSX-MANAGER-MIB::vmwNsxMInconsistentSvmAlarm

Start monitoring VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VMWARE-NSX-MANAGER-MIB::vmwNsxMInconsistentSvmAlarm OID value, configure state conditions and alerts, and monitor any VMware NSX Manager appliances, SDDC/vSphere environments (controller/transport-node fault-event notification status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6876vmwareVMWARE-ROOT-MIB
1.3.6.1.4.1.6876.90vmwNsxManagerVMWARE-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6876.90.1vmwNsxManagerMIBVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2vmwNsxMNotificationVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.11vmwNsxMSvmOperationsVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.11.0vmwNsxMSvmOperationsPrefixVMWARE-NSX-MANAGER-MIB
1.3.6.1.4.1.6876.90.1.2.11.0.1vmwNsxMInconsistentSvmAlarmVMWARE-NSX-MANAGER-MIB